Post Buy Requirement

Our Products

  1. Laboratory Apparatus 28 Products available
  2. Industrial Machinery 17 Products available
  3. Testing Equipment 11 Products available
  4. Measuring Instruments & Equipment 11 Products available
  5. Viscosity Instruments 5 Products available
  6. Laboratory Shakers 4 Products available
  7. Tables 4 Products available
  8. Measurement Gauges & Fittings 4 Products available
  9. Lab Instrument 3 Products available
  10. Others Products 75 Products available

Laboratory Apparatus

Our product range contains a wide range of Cleveland Flash Fire Point Apparatus, Blain Air Permeability Apparatus, Vicat Needle Apparatus, Concrete Permeability Apparatus and Consolidation Test Apparatus

Cleveland Flash Fire Point Apparatus

This apparatus is used for determination of Flash Point & Fire Point of Petroleum products except fuel oil with open flash 800C as per specification IP 36/57, IS 1448 (P:69) 1969 and ASTM-D-92-67.

The apparatus consists of a cup, heating plate, and thermometer clip and test flame attachment with swivel joint for passing over liquid surface in the prescribed manner; heater is controlled by means of Energy Regulator for operation on 230 volts, 50Hz, AC single phase.

  • Cleveland Flash Point Apparatus electric heated with voltage carriac copper coil type.
  • Thermometer IP 28C Range -6 to +400C
  • Polished carrying wood case.
  • Spare cup with handle only.
View Complete Details

Blain Air Permeability Apparatus

The fineness of cement has a significant effect in its physical properties when used in concrete. Generally the finer the cement powder, the more rapid the concrete will set, as there is an increase in its surface area. The measure of fineness is usually undertaken by sieving, and the result assessed against the cement standard for compliance.

The Blaine air permeability apparatus is used to determine the fineness of Portland cement in terms of the specific surface expressed as total surface area in square centimeters per gram of cement. The Blaine apparatus draws a defined volume of air through a prepared bed of cement of defined porosity.

The apparatus comprises one each of Brass or stainless steel permeability cell 12.5mm, 'U' tube manometer with stop cock mounted on a laminated wooden stand, perforated metal disc, plunger, Rubber stopper, Rubber tube - 30cm long with rubber bulb.

  • Balance with 0.001 gm resolution
  • Stop Watch with 0.5 second resolution
  • Manometer Liquid
  • Whatman Filter Paper
  • Filter Punch
View Complete Details

Vicat Needle Apparatus

Used to determine the amount of water required to produce a cement paste of standard consistency and the setting time. The time it takes for a cement to stiffen to a standard value after addition of water is commonly known as the set time. The test involves mixing cement with water and then measuring its resistance to penetration of a standard probe at varying intervals of time, until a certain value is reached.

View Complete Details

Concrete Permeability Apparatus

A concrete structure is considered to be of adequate durability if it performs in accordance with its intended level of functionality and serviceability over an expected or predicted life cycle. Concrete durability depends largely on the ease (or difficulty) with which fluids (water, carbon dioxide, oxygen) in the form of liquid or gas can migrate through the hardened concrete mass. Concrete is a porous material. Therefore, moisture movement can occur by flow, diffusion, or sorption. We are concerned with all three, but generally the overall potential for moisture in concrete by these three modes is referred to as its permeability.

The set up consist of permeability cell, water reservoir and pressure lines, with glass bottles.

Consists of a metal cylinder with a ledge at the bottom for retaining the specimen, a flange at the top, removable cover plate and a funnel. A rubber gasket is seated in matching grooves, between the cell and the cover plate, to render the joint water tight. Internal working size of the cell will be 100mm dia X 100mm height.

Consists of a length of metal pipe, 50 to 100 mm in diameter and about 500 mm long. The reservoir fitted with a graduated side arm gauge-glass for admitting water and compressed air and a cock for drainage, bleeding and connection to the permeability cell.

Heavy duty armored rubber hose with end fittings. Complete with glass bottles but without compressor. For specimen size 100 X 100 mm

Concrete permeability tester for three specimen of (100mm dia x 100mm height) or (150mm dia x 150mm height) or (150mm cube) is also available.

Relevant Standard: IS: 3085

View Complete Details

Consolidation Test Apparatus

Loading Unit, maximum capacity 20 kg/cm2 consisting of a loading yoke connected to a lever arm with a counter- balancing adjustment and having a lever ratio of 1:10, the whole assembly being mounted on a steel frame stand.

Consolidation cell assembly, fixed ring type for testing 60 mm dia x 20 mm thick specimens comprising:

Fixed ring for specimens 60 mm dia x 20 mm thick with a guide ring.

Top porous stone for 60 mm dia specimen.

Bottom porous stone for 60 mm dia specimen.

Pressure pad, perforated

Channeled base with water inlet.

Gasket.

Flanged water jacket,

Set of weights to give a pressure of 10 kg/cm2 on 60 mm specimen. Comprising: 7 off 0.05 kg/cm2, 5 off 0.1 kg/cm2, 6 off 0.2 kg/cm2, 6 off 0.5 kg/cm2, and 5 off 1.0 kg/cm2.

Water reservoir with plastic tube, T-connection and pinch cock.

Dial gauge, 0.01 mm x 25 mm travel

View Complete Details

Cleveland Flash Fire Point

This apparatus is used for determination of Flash Point & Fire Point of Petroleum products except fuel oil with open flash 800C as per specification IP 36/57, IS 1448 (P:69) 1969 and ASTM-D-92-67.

The apparatus consists of a cup, heating plate, and thermometer clip and test flame attachment with swivel joint for passing over liquid surface in the prescribed manner; heater is controlled by means of Energy Regulator for operation on 230 volts, 50Hz, AC single phase.

  • Cleveland Flash Point Apparatus electric heated with voltage carriac copper coil type.
  • Thermometer IP 28C Range -6 to +400C
  • Polished carrying wood case.
  • Spare cup with handle only.
View Complete Details

Aggregate Crushing Value Apparatus

The aggregate crushing value provides a relative measure of the resistance of an aggregate to crushing under a gradually applied compressive load. The oven dried and accurately weighed aggregates are subjected to crushing test on compression testing machine and weight of the resultant fines passing the specified IS sieve to the total weight of the sample expressed a s a percentage is defined as Aggregate Crushing Value. The apparatus is available in three size 75mm dia for 1/8 to size aggregate, 150mm dia for 3/8 to aggregate (standard) and 300mm dia for 1 to 2 aggregate.

Consists of Case hardened Mild steel cylindrical container of 150mm dia+0.5mm x 130mm to 140mm high with base plate 200 to 230mm square x 6mm thick. A plunger of 148mm+0.5mm dia x 100 to 115mm high. All parts directly coming in to contact with the specimen during the test are made of mild steel duly case hardened. Supplied complete with tamping rod, 16mm dia x 600mm long, one end rounded.

The following accessories are not part of the standard supply and are supplied at an extra cost.

Cylindrical Metal measure 11.5cm dia x 18cm height with handle.

Electronic Balance 3 kg. X 1 gm

Compression Testing Machine Capacity : 500 kN

Test Sieve 2.36mm, 10mm, 12.5mm and 14m

View Complete Details

Benkelman Beam Apparatus

The device was developed by U.S. Bureau of Public Roads and is used to determine of the rebound deflection of flexible pavement under static load.

Benkelman Beam: Beam Ratio: 2: 1

a) Length of the probe arm from pivot to probe point 244cm.b) Length of measurement arm from pivot to dial 122 cm.c) Distance form pivot to front legs 25cm.d) Distance from pivot to rear legs 166cm ande) Lateral spacing of front support legs 33cm.

The complete instrument is light weight and is supplied in two parts for easy assembling and disassembling on site with help of hand tools and also it becomes easy to carry with the help of handle.

In use one end of the beam rests at a point under investigation while the beam is pivoted at the centre. The free end carries a dial gauge to record the deflections and the other end is kept on the stable platform. Because of beam ratio small deflection is magnified and recorded on the dial gauge.

In use one end of the beam rests at a point under investigation while the beam is pivoted at the centre. The free end carries a dial gauge to record the deflections and the other end is kept on the stable platform. Because of beam ratio small deflection is magnified and recorded on the dial gauge

Dial Gauge:0.01 x 25mm. Spirit Level.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Laboratory Apparatus from Delhi, Delhi by Perfect Technologies
Post Buy Requirement

Our Products

  1. Laboratory Apparatus 28 Products available
  2. Industrial Machinery 17 Products available
  3. Measuring Instruments & Equipment 11 Products available
  4. Testing Equipment 11 Products available
  5. Viscosity Instruments 5 Products available
  6. Tables 4 Products available
  7. Measurement Gauges & Fittings 4 Products available
  8. Laboratory Shakers 4 Products available
  9. Lab Instrument 3 Products available
  10. Others Products 75 Products available

Laboratory Apparatus

Our Complete range of products are Cleveland Flash Fire Point Apparatus, Blain Air Permeability Apparatus, Vicat Needle Apparatus, Concrete Permeability Apparatus and Consolidation Test Apparatus.

Cleveland Flash Fire Point Apparatus

This apparatus is used for determination of Flash Point & Fire Point of Petroleum products except fuel oil with open flash 800C as per specification IP 36/57, IS 1448 (P:69) 1969 and ASTM-D-92-67.

The apparatus consists of a cup, heating plate, and thermometer clip and test flame attachment with swivel joint for passing over liquid surface in the prescribed manner; heater is controlled by means of Energy Regulator for operation on 230 volts, 50Hz, AC single phase.

  • Cleveland Flash Point Apparatus electric heated with voltage carriac copper coil type.
  • Thermometer IP 28C Range -6 to +400C
  • Polished carrying wood case.
  • Spare cup with handle only.
View Complete Details

Blain Air Permeability Apparatus

The fineness of cement has a significant effect in its physical properties when used in concrete. Generally the finer the cement powder, the more rapid the concrete will set, as there is an increase in its surface area. The measure of fineness is usually undertaken by sieving, and the result assessed against the cement standard for compliance.

The Blaine air permeability apparatus is used to determine the fineness of Portland cement in terms of the specific surface expressed as total surface area in square centimeters per gram of cement. The Blaine apparatus draws a defined volume of air through a prepared bed of cement of defined porosity.

The apparatus comprises one each of Brass or stainless steel permeability cell 12.5mm, 'U' tube manometer with stop cock mounted on a laminated wooden stand, perforated metal disc, plunger, Rubber stopper, Rubber tube - 30cm long with rubber bulb.

  • Balance with 0.001 gm resolution
  • Stop Watch with 0.5 second resolution
  • Manometer Liquid
  • Whatman Filter Paper
  • Filter Punch
View Complete Details

Vicat Needle Apparatus

Used to determine the amount of water required to produce a cement paste of standard consistency and the setting time. The time it takes for a cement to stiffen to a standard value after addition of water is commonly known as the set time. The test involves mixing cement with water and then measuring its resistance to penetration of a standard probe at varying intervals of time, until a certain value is reached.

View Complete Details

Concrete Permeability Apparatus

A concrete structure is considered to be of adequate durability if it performs in accordance with its intended level of functionality and serviceability over an expected or predicted life cycle. Concrete durability depends largely on the ease (or difficulty) with which fluids (water, carbon dioxide, oxygen) in the form of liquid or gas can migrate through the hardened concrete mass. Concrete is a porous material. Therefore, moisture movement can occur by flow, diffusion, or sorption. We are concerned with all three, but generally the overall potential for moisture in concrete by these three modes is referred to as its permeability.

The set up consist of permeability cell, water reservoir and pressure lines, with glass bottles.

Consists of a metal cylinder with a ledge at the bottom for retaining the specimen, a flange at the top, removable cover plate and a funnel. A rubber gasket is seated in matching grooves, between the cell and the cover plate, to render the joint water tight. Internal working size of the cell will be 100mm dia X 100mm height.

Consists of a length of metal pipe, 50 to 100 mm in diameter and about 500 mm long. The reservoir fitted with a graduated side arm gauge-glass for admitting water and compressed air and a cock for drainage, bleeding and connection to the permeability cell.

Heavy duty armored rubber hose with end fittings. Complete with glass bottles but without compressor. For specimen size 100 X 100 mm

Concrete permeability tester for three specimen of (100mm dia x 100mm height) or (150mm dia x 150mm height) or (150mm cube) is also available.

Relevant Standard: IS: 3085

View Complete Details

Consolidation Test Apparatus

Loading Unit, maximum capacity 20 kg/cm2 consisting of a loading yoke connected to a lever arm with a counter- balancing adjustment and having a lever ratio of 1:10, the whole assembly being mounted on a steel frame stand.

Consolidation cell assembly, fixed ring type for testing 60 mm dia x 20 mm thick specimens comprising:

Fixed ring for specimens 60 mm dia x 20 mm thick with a guide ring.

Top porous stone for 60 mm dia specimen.

Bottom porous stone for 60 mm dia specimen.

Pressure pad, perforated

Channeled base with water inlet.

Gasket.

Flanged water jacket,

Set of weights to give a pressure of 10 kg/cm2 on 60 mm specimen. Comprising: 7 off 0.05 kg/cm2, 5 off 0.1 kg/cm2, 6 off 0.2 kg/cm2, 6 off 0.5 kg/cm2, and 5 off 1.0 kg/cm2.

Water reservoir with plastic tube, T-connection and pinch cock.

Dial gauge, 0.01 mm x 25 mm travel

View Complete Details

Cleveland Flash Fire Point

This apparatus is used for determination of Flash Point & Fire Point of Petroleum products except fuel oil with open flash 800C as per specification IP 36/57, IS 1448 (P:69) 1969 and ASTM-D-92-67.

The apparatus consists of a cup, heating plate, and thermometer clip and test flame attachment with swivel joint for passing over liquid surface in the prescribed manner; heater is controlled by means of Energy Regulator for operation on 230 volts, 50Hz, AC single phase.

  • Cleveland Flash Point Apparatus electric heated with voltage carriac copper coil type.
  • Thermometer IP 28C Range -6 to +400C
  • Polished carrying wood case.
  • Spare cup with handle only.
View Complete Details

Aggregate Crushing Value Apparatus

The aggregate crushing value provides a relative measure of the resistance of an aggregate to crushing under a gradually applied compressive load. The oven dried and accurately weighed aggregates are subjected to crushing test on compression testing machine and weight of the resultant fines passing the specified IS sieve to the total weight of the sample expressed a s a percentage is defined as Aggregate Crushing Value. The apparatus is available in three size 75mm dia for 1/8 to size aggregate, 150mm dia for 3/8 to aggregate (standard) and 300mm dia for 1 to 2 aggregate.

Consists of Case hardened Mild steel cylindrical container of 150mm dia+0.5mm x 130mm to 140mm high with base plate 200 to 230mm square x 6mm thick. A plunger of 148mm+0.5mm dia x 100 to 115mm high. All parts directly coming in to contact with the specimen during the test are made of mild steel duly case hardened. Supplied complete with tamping rod, 16mm dia x 600mm long, one end rounded.

The following accessories are not part of the standard supply and are supplied at an extra cost.

Cylindrical Metal measure 11.5cm dia x 18cm height with handle.

Electronic Balance 3 kg. X 1 gm

Compression Testing Machine Capacity : 500 kN

Test Sieve 2.36mm, 10mm, 12.5mm and 14m

View Complete Details

Benkelman Beam Apparatus

The device was developed by U.S. Bureau of Public Roads and is used to determine of the rebound deflection of flexible pavement under static load.

Benkelman Beam: Beam Ratio: 2: 1

a) Length of the probe arm from pivot to probe point 244cm.b) Length of measurement arm from pivot to dial 122 cm.c) Distance form pivot to front legs 25cm.d) Distance from pivot to rear legs 166cm ande) Lateral spacing of front support legs 33cm.

The complete instrument is light weight and is supplied in two parts for easy assembling and disassembling on site with help of hand tools and also it becomes easy to carry with the help of handle.

In use one end of the beam rests at a point under investigation while the beam is pivoted at the centre. The free end carries a dial gauge to record the deflections and the other end is kept on the stable platform. Because of beam ratio small deflection is magnified and recorded on the dial gauge.

In use one end of the beam rests at a point under investigation while the beam is pivoted at the centre. The free end carries a dial gauge to record the deflections and the other end is kept on the stable platform. Because of beam ratio small deflection is magnified and recorded on the dial gauge

Dial Gauge:0.01 x 25mm. Spirit Level.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us