Post Buy Requirement
PS

Perfect Sales Corporation

Verified Add Review

Our Products

  1. Transformers 5 Products available
  2. Electrical Cables & Wires

    1 Products available
  3. Electrical & Electronic Testing Devices

    1 Products available
  4. Bushings

    1 Products available
  5. Others Products 3 Products available

Transformers

We offer the best product range of Resin Cast C. T., Oil Cooled C. T, LT Tape Wound Current Transformer, Current Transformers and Potential Transformer.

Resin Cast C. T.

A Current Transformer is the measuring device for metering and protection system. The primary current of the CT is transformed into the required secondary current of 5 A or 1 A.

Measuring CT's have different class of accuracy I.e. 0.1, 0.2S, 0.2, 0.5S, 0.5 and 1.0 and protection CT's have 5P10, 5P20 and 10P10. In the case of special protection CT's(PS class), the Knee Point Voltage(KV) of the CT is specified along with secondary resistance and magnetizing current.

The construction of the CT not only depends upon the ratio but also on the Short Time Current Rating, Burden and Class of Accuracy.

View Complete Details

Oil Cooled C. T

A Current Transformer is the measuring device for metering and protection system. The primary current of the CT is transformed into the required secondary current of 5 A or 1 A.

Measuring CT's have different class of accuracy I.e. 0.1, 0.2S, 0.2, 0.5S, 0.5 and 1.0 and protection CT's have 5P10, 5P20 and 10P10. In the case of special protection CT's(PS class), the Knee Point Voltage(KV) of the CT is specified along with secondary resistance and magnetizing current.

The construction of the CT not only depends upon the ratio but also on the Short Time Current Rating. Burden and Class of Accuracy.

View Complete Details

LT Tape Wound Current Transformer

A Current Transformer is the measuring device for metering and protection system. The primary current of the CT is transformed into the required secondary current of 5 A or 1 A.

Measuring CT's have different class of accuracy I.e. 0.1, 0.2S, 0.2, 0.5S, 0.5 and 1.0 and protection CT's have 5P10, 5P20 and 10P10. In the case of special protection CT's(PS class), the Knee Point Voltage(KV) of the CT is specified along with secondary resistance and magnetizing current.

The construction of the CT not only depends upon the ratio but also on the Short Time Current Rating. Burden and Class of Accuracy.

View Complete Details

Current Transformers

A Current Transformer is the measuring device for metering and protection system. The primary current of the CT is transformed into the required secondary current of 5 A or 1 A.

Measuring CT's have different class of accuracy I.e. 0.1, 0.2S, 0.2, 0.5S, 0.5 and 1.0 and protection CT's have 5P10, 5P20 and 10P10. In the case of special protection CT's(PS class), the Knee Point Voltage(KV) of the CT is specified along with secondary resistance and magnetizing current.

The construction of the CT not only depends upon the ratio but also on the Short Time Current Rating. Burden and Class of Accuracy.

View Complete Details

Potential Transformer

The primary and secondary winding of Potential Transformer is magnetically coupled by a core. PT is used to further step down the system voltage to measurable value up to 63.5 V, 100 V or 110 V as per standard of the equipment.

The typical class of accuracy of metering PT are 0.1, 0.2, 0.5, 1.0 and protection PT is 3P. The PT's are offered in single phase or three phase version.