Our Products
Security, Metal & Leak Detectors
2 Products availableLaboratory Equipments
2 Products availableTrolleys
1 Products availableGas Regulators
1 Products availableGas Analyzers
1 Products availableAir Compressor
1 Products availableDryers
1 Products availableLaboratory Ovens
1 Products availableWe offer the best product range of casing capping.
Salient Features & Benefits:
Deliver Ultra High Pure (UHP) Grade GasesCompact Design, Wall Mounted, Powder CoatedFilters are easily detachableSuitable for 10kg/cm inlet pressure & 7 kg/cm outlet pressurePanel for LC-MS-MS & other applications are also availableReduce baseline noise, drift problems, etc.Increase column life, GC detectors & reduces flame problemsImprove reproducibilitySave costly gases through toggle valves & gas distribution panel.
APPLICATION | FILTER TYPE | MAX. INLET IMPURITY LEVEL |
MAX. OUTLET IMPURITY LEVEL |
LENGTH End to End |
CAPACITY |
---|---|---|---|---|---|
Moisture Removal | Silicagel / Molecular Sieve | 20 ppm | < 3 ppm | 10" | 210 CC |
Hydro Carbon Removal |
Activated Charcoal / Carbon |
10 ppm | < 2 ppm | 10" | 210 CC |
Oxygen Removal | De-Oxo Chemical catalyst |
10 ppm | < 2 ppm | 8" | 125 CC |
Particle Removal | Micron Filter | 25 μ | < 0.5 μ | 2" | — |
Inline Micron Filters are used to remove dust particles from respective gases. Micron filter (SSbody) consist of SS disc (Mesh) of 5 - 10.
Gas purification panel removes impurities which are in vapours (gases) form. Cylinders being M.S.body has the tendency to illute dust particles, these particles may come in the line and may go togas chromatograph. To avoid this particles micron filters are very essential.
Tubing are available in different sizes like 1/2", 1/4", 1/8", 1/16"
Tubing available in different MOC like copper, S.S., teflon, nylon.
Casing capping are used to cover the above tubing & to maintain theesthetic look.
Three types casing capping available, M.S. powder coated, alluminiumpowder coated & PVC casing capping.
Cylinder trolley in MS powder coated 4 wheel for smooth & safe operation.
Cylinder trolley available for single & two cylinder.
Cylinder mounting brackets are used to mount the cylinder on wall to avoid down fall of cylinder.
Mounting bracket available with wall and floor mounting.
Gas sampling bottle is used for storing / transporting gas sample at high & low pressure. Available in250ml, 500ml, 1000ml & above
Air header is used for the distribution of compress air or any gas with one inlet various outlet withneedle / ball valve.
PCI Manufacturers Various kinds of Regulators. PCI Regulators have been designedto meet the demand of High Purity Corrosion Resistance ProductSpecially Suitedfor low level PPM Moisture
Two types of Cylinder Regulators available Brass Chrome Plated body with SSdiaphragm and SS body with SS diaphragm.Regulator consist of inlet & outlet pressure gauges. Inlet pressure gauge showsthe total pressure of cylinder and outlet pressure gauge shows regulated pressure.High pressure piston type Regulator & Regulators for corrosive gases likeAmmonia, Clorine, etc. are also available.Inlet pressure range: 0 - 240 kg/cmOutlet pressure range: 0 - 14 kg/cm in diaphragm typeOutlet pressure range: 0 - 40, 0 - 70, 0 - 100 kg/cm in piston type
Double Stage Cylinder Regulator specifications :Two types of Cylinder Regulators available Brass Chrome Plated body with SS diaphragm and SSbody with SS diaphragm.Regulator consist of inlet & outlet pressure gauges. Inlet pressure gauge shows the totalpressure of cylinder and outlet pressure gauge shows regulated pressure.Inlet pressure range: 0 - 240 kg/cmOutlet pressure range: 0 - 14 kg/cm diaphragm type
Cylinder Regulator- Acetylene/N2O/Argon Specifications :Cylinder Regulator for the controlling of outlet pressure of cylinder for Acetylene & Nitrous oxide &Argon gasM. O. C. : Brass Chromplated Body or SS Body with SS DiaphragmPre heater for Nitrous oxide gas
Features:Dual display of gas concentration & set point/ unit of the gasPlug in smart field proven sensorProgrammable linear 4-20mA/ 20-4mA O/P with respect to gasconcentrationEasy one man calibration at siteOptional RS-485 with modbus RTU protocolSuitable in hazardous area ATEX, CCOE, CMRI & IP-65 approved.
Applications:Gas cylinder bankGas pipeline projectChemical processing plantRefineriesChemical & petrochemical plantsOil & gas industriesFertilizers plantsGas metering stationChemical storage area
Oxygen Analyser is used to detect the Oxygen level in any given gas, Oxygen Analyser available in PPM and Percentage type. Oxygen Analyser are of different ranges 0-30%, 0-100% & 0-5000 PPM, Oxygen Analyser has electrochemical type sensor. Oxygen Analyser has Digital display with 2 PPM or 0.01% resolution. Maximum operating pressure and temperature is 0.5bar and Ambient plus or minus 10 degree Celsius.
Portable Oxygen Indicator( INTERNAL SENSOR ) MODEL OIP 02I
Applications : Common applications including checking of
Air Compressors is used for Analytical instruments like AAs, NMR, TOC etc. Air Compressors are oil free, oil based. Air Compressors are reciprocating, screw & Scroll type. Air Compressors for AAs is used to produce flame by reacting with Acetylene.
CPM / CPA Features:
Electric screw compressors
Starting from 5.5kw/7.5hp to15kw/20hp
FAD 22 cfm to 71 cfm
Available in three pressure variant 7, 10 & 13 bar (g)
Also available with inverter drive (IVR)
Model | Motor Rating HP |
Piston Displacement | Operating Pressure |
Tank Capacity |
||
---|---|---|---|---|---|---|
LPM | CFM | |||||
Anest Iwata | ||||||
TFS 10B-9 | 1 | 151 | 5.34 | 125 | 8.5 | 40 |
TFS 20B-9 | 2 | 267 | 9.44 | 125 | 8.5 | 80 |
TFS 30B-9 | 3 | 408 | 14.41 | 125 | 8.5 | 80 |
TFS 50B-9 | 5 | 649 | 22.93 | 125 | 8.5 | 160 |
TFS 75B-9 | 7.5 | 692 | 24.43 | 125 | 8.5 | 250 |
TFS 100B-9 | 10 | 1038 | 36.66 | 125 | 8.5 | 250 |
Indian | ||||||
HS-WP-1T | 0.75 | 60 | 2 | 100 | 7 | 20 |
HS-WP-2T | 1 | 100 | 3.5 | 100 | 7 | 20 |
PCI-KI-20T(Imp) | 0.75 | 60 | 2 | 100 | 7 | 20 |
Chicago Pneumatic | ||||||
CPM 5 | 5 | 460 | 16.6 | 62 | 10 | 200 |
CPM 7 | 7.5 | 590 | 21.2 | 65 | 10 | 200 |
CPA 10/7 | 10 | 1170 | 42 | 68 | 7 | 500 |
CPA 10/10 | 10 | 980 | 35 | 68 | 10 | 500 |
CPA 15/7 | 15 | 1625 | 58 | 68 | 7 | 500 |
CPA 15/10 | 15 | 1400 | 50 | 68 | 10 | 500 |
CPA 20/7 | 20 | 1980 | 71 | 68 | 7 | 500 |
CPA 20/10 | 20 | 1765 | 63 | 68 | 10 | 500 |
PSA/Desicant Air Dryer:Standard compressed air enters to PSA unit where all the impurities like: moisture, CO, CO2 etc areremoved to produced clean dry air upto -60 dew point.
Refrigerated Air Dryer:Standard compressed air enters to the Air to Air heat exchange, where it is pre cooled by out going cold dryair. Highly effective pre cooler reduces the temperature considerably, and enable to use smaller &economical refrigeration system. Then the pre cooled, relatively low temperature compressed air enters toAir to Refrigerant heat exchanger, where it is cooled down to +3C (Pressure Dew Point). At thistemperature, moisture in vapour form condensed to liquid form, and separated from the compressed air bymoisture separator and discharged to drain port through automatic drain valve. Thecold dry compressesair passes back to Air to Air Heat Exchanger, and gain temperature by exchanging heat with incoming warmair. The dry air coming out from the dryer is ready to use for instrumentation and process air applications.
Model | Capacity CFM |
Working Pressure kg/cm² |
Connections BSP |
Refrigerant | Power supply v/ph |
Condensor type | Nominal power Consumption kw |
Overall Dimensions in mm | Approx Weight (kgs.) | ||
---|---|---|---|---|---|---|---|---|---|---|---|
L | B | H | |||||||||
PPS-15 | 15 | 16 | 1/2" | R134a | 220/1 | Air | 0.19 | 350 | 350 | 550 | 25 |
PPS-24 | 24 | 16 | 1/2" | R134a | 220/1 | Air | 0.19 | 400 | 500 | 550 | 32 |
PPS-45 | 45 | 16 | 1/2" | R134a | 220/1 | Air | 0.37 | 400 | 500 | 550 | 35 |
PPS-60 | 60 | 16 | 3/4" | R134a | 220/1 | Air | 0.37 | 550 | 550 | 730 | 60 |
PPS-80 | 80 | 16 | 3/4" | R134a | 220/1 | Air | 0.60 | 550 | 550 | 730 | 65 |
PPS-100 | 100 | 16 | 1 1/2" | R134a | 220/1 | Air | 0.60 | 550 | 750 | 900 | 78 |
PPS-150 | 150 | 16 | 1 1/2" | R134a | 220/1 | Air | 1.11 | 700 | 750 | 900 | 90 |
PPS-200 | 200 | 16 | 1 1/2" | R134a | 220/1 | Air | 1.11 | 700 | 750 | 900 | 92 |
Zero Air Generator produces a continuous flow of high purity Zero Air at selected pressure.
The modular pressure swing adsorption (PSA) unit operates with alternating pressure increase and decrease.
Untreated air flows under pressure through the reaction towers containing molecular sieve adsorber.
Moisture, CO, CO2, THC and other unwanted components in the air are adsorbed, leaving Zero Air Gas of required purity.
The Zero Air Generators are suitable for use in laboratories and industrial environments.
Microcontroller digital display
Salient Features:Deliver constant pressure & flowFully Automatic Programmable SystemEasy Maintenance and space savingEffortless and easy operationImproves instrument performanceFully regenerative, durability with PSA technology
Applications:GC-FID, FPD, NPD, TCD, AEDGC-MS, LC-MS-MS, ICP / NMRFTIR / IR, ELSD detectorPurging, Ampule FillingThermal instruments, Turbo Evaporator (N2 Concentrator)All Analytical Instruments
Note:Zero Air Generator (Model ZAG-02) requires oil free compressed air line of 60 LPM at 6 kg/cmOil free compressor can be provided by PCI.For model ZAG-03, PCI oil free compressor is recommended
Nitrogen Generator produces a continuous flow of high purity Nitrogen at selected pressure.
The modular pressure swing adsorption (PSA) unit operates with alternating pressure increase and decrease.
Untreated air flows under pressure through the reaction towers containing carbon molecular sieves adsorber. Moisture, CO, CO2, THC, O2 and other unwanted components in the air are adsorbed, leaving Nitrogen Gas of required purity.
During the desorption cycle, the trapped substances adsorbed are released again at low pressure and the adsorber is ready for next cycle.
Flow range available from 100 ml to 2000 ml and above.
Microcontroller digital display
Salient Features:Deliver constant pressure & flowFully Automatic Programmable SystemEasy Maintenance and space savingEffortless and easy operationImproves instrument performanceFully regenerative, durability with PSA technology
Applications:GC-FID, FPD, NPD, TCD, AEDGC-MS, LC-MS-MS, ICP / NMRFTIR / IR, ELSD detectorPurging, Ampule FillingThermal instruments, Turbo Evaporator (N2 Concentrator)All Analytical Instruments
PGH-300 | PGH-500 | PGH-1000 | |
Max Hydrogen Flowrate | 300 ml/min | 500 ml/min | 1000 ml/min |
Delivery Pressure | 0-60 psig (0-0.4 Mpa) | ||
% purity | >99.999% | ||
Power Consumption | 150W | 180W | 220W |
Power | 198-242V (AC); 50Hz,1 Phase | ||
Min/max Temperature | 5-40°C | ||
Max. Ambient Humidity | <85% RH | ||
Suitable Environment | non-corrosive and dust-free | ||
Dimensions | 420 x 210 x 350mm (LxWxH) | ||
Weight | 12 kg (approx) | ||
Fluid Tank Capacity | 1.5 L | ||
Fluid Consumption | Weekly or when level falls below 0.6 |
1) GAS TRANSMITTER ( PCI-GT-1000 FLP)3" wire gas transmitter with LED display, 4-20mA output in Flameproof Enclosure with Catalyst Sensor for Combustible gas.
2) MULTICHANNEL GAS MONITOR UNIT 1 44, 000.00 EACH Model: (PCI -TC 100 WP) mounted in Main compartment of Mild Steel Powder Coated Paint Finish Body.Micro-controller based Scanner type monitor. Digital Display for easy to read Gas Concentration online on monitor with two window display for Channel assessment and actual value of gas analyses per channel. Acknowledge function with user friendly operation & programmable by easy soft Key
3) HOOTER CUM FLASHER Standard Hooter 1 6, 000.00 EACH for Safe Area.
4) CABLE (3 core X 1.5 mm2) Armored Shielded Cable 1 190.00 METER for Gas Transmitter to Monitor (Quantity on Actually Running Meter)7/0.3mm (0.5sq mm) in continuous contact with Aluminum side of the tape, PVC inner sheathed of types STI as per IS 5831/84 with 0.5 mm thickness in Black color, galvanized steel wire armored as per IS 583/84 in Black color suitable for 1100 V." (Qty. on actual running meter basis).
Flow Range :
DFM-01 : 1 ml/min. to 50 ml/min. with least count of 0.1 ml/min
DFM-02 : 5 ml/min. to 500 ml/min. with least count of 1 ml/min
DFM-03 : 200 ml/min. to 2000 ml/min. with least count of 1 ml/min
DFM-04 : 1 ml/min. to 500 ml/min. with least count of 0.1 ml/min (auto range)
DFM-05 : 1 ml/min. to 1000 ml/min. with least count of 0.1 ml/min (auto range)
DFM-06 : 10 ml/min. to 400 ml/min. with least count of 1 ml/min. (auto range)
DFM-07 : 0.5 mL/min to 750 mL/min, auto-ranging
DFM-08 : Flow for gases across a range of 5-500 mL/min
High frequency electrical energy is converted into ultrasound waves by means of ultrasonic Tranducers, which are bonded on the base of S. S. Water Tank. These high frequency sound waves create in the liquid countless, Microscopic Vacuum Bubbles, which repidly expand and collapse. This phenomenon is CAVITAION. These bubbles act like miniature high speed brushes, driving the liquid in to all openings and minutes recesses of the Object immersed in the liquid. Intense scrubbing of Cavitation cleans away all the dirt and soil from the object immersed and the object is perfectly cleaned. Intricate objects can be cleaned with either complete or little Dismantling.
Capacity |
Tank Size (LxBxH) mm |
Overall Dimension (LxBxH) mm |
Wattage |
1.5 Lit | 240x135x65 | 265x160x180 | 60W |
3.5 Lit. | 300x150x100 | 330x175x250 | 120W |
6.5 Lit. | 300x150x150 | 450x200x350 | 200W |
9 Lit. | 300x200x150 | 450x300x375 | 250W |
The ideal instrument for IQ/OQ/PQ and troubleshooting
Accurate to 1% of reading with guaranteed linearity from 0.05 to 25.00 ml/min
Durable and easy to use with any HPLC pump
Easy diagnosis of leaking piston seals or malfunctioning check valves
Automatic Data Transfer
- Dramatically simplify liquid flow rate data collection for HPLC IQ/OQ/PQ
- Collect flow rate data via RS232 or with a new optional battery powered mini printer or with software
Specially design software converts data received in to pdf file. Average set of data & gives average reading, mean value
standard deviation & many more
PCI is pleased to introduce the FlowCal 5000
Models Availible-
Name - LFM-01
Name - LFM-02
Name - LFM-03
**Five Point Calibration Also Avalible
The new instrument measures liquid flow over a wide range, from 50l/min to 25ml/min. You can see the working flow ranges and accuracy in the table below. Flow rate is measured by volume and is independent of the liquid type up to a viscosity of 10 centipoise.The unit uses a single chip micro-controller, the flow rate (rounded to four digits) is displayed on a large four digit back-lit Liquid Crystal Display (LCD) and data can be conveniently output via the built-in RS232 interface to the full 6-digit reading. No user calibration is required; the unit is generally supplied gravimetrically calibrated at 1.0 (+10%) ml/min. Calibration at multiple points is available. All wetted parts are made of PTFE , PEEK, DAI-EL PERFLOUR or Pyrex glass. There are no wetted metallic parts.
Three modes of operation are available:Printer Mode: liquid flow readings are displayed on the LCD and output to a printer if one is connected. A running average option is available in this modeTerminal Mode: in this mode the liquid flowmeter is controlled by the terminal or PC. Extra commands for averaging any number of readings are included.Test Mode: this mode allows the user to test the display, valve and RS232 interface and also display the calibration date.
The RS232 output allows the flowmeter to output data to any device fitted with an RS232 serial interface e.g. printer, terminal or personal computer. The unit is supplied with an RS232 cable fitted with a nine way female plug to connect directly to the COM port of a PC. By using the Terminal or Hyper-Terminal program supplied with MS Windows results can be collected and displayed or pasted into Excel or other programs to produce graphs or statistical analysis. The baud rate is internally switch selectable for 19200, 9600, 4800, 2400, 1200, 600, 300 baud with the option of sending a CR/LF after each reading. X-on / X-off handshaking is used.
All instruments are supplied with the following:Mains wall block power supply with a choice of 240v 3 pin UK, 230v 2 pin European or 100v 2 pin USA/Japan.RS232 input/output cable: 8way mini-din plug to PC COM port 9 pin female.UKAS traceable single point flow calibration certificate is supplied as standard (UKAS is the UK equivalent of NIST)Universal mounting kit: allows free standing mount, wall mounting, stack system mounting and bottle top mount.Black plastic carrying case with foam inserts. All parts of the mounting kit are packed within the carrying case.Cleaning kit now supplied with the flow meter.
FlowCal 5000 SpecificationsReading Update Time- 15 sec @ 2 ml/min- 25 sec @ 1 ml/min- 45 sec @ 0.5 ml/minMeasuring Volume - 140 lPriming Volume - 250 lLCD Display - (12.7mm)- 4 digits and 3 status symbolsRS232 output - (6 digits) XX.XXXX ml/minSize - 138mm x 76mm x 45mmWeight - 320g, 12 oz
Salient Features :Precise Temperature ControlDigital display of set & actual temp.Insures Reproducible AnalysisAccepts Varieties of Column SizesAssures Safe, Accurate Control action
Model Selection :HCO-01 : Separate Oven & Temp. ControllerHCO-02 : Inbuilt temperature controller & ovenHCO-03 : Inbuilt heating of Rheodyne InjectorHCO-04 : Force air circulation heating type oven
Consist of :
Micro Controller based / PID Temperature ControllerOven Module
Sterility Test Unit47mm Stainless Steel (3 Branch Sterility)
Sterility Test Unit47mm Stainless Steel (6 Branch Sterility
Oil Free Vacuum Pump suitable for above Sterility
Model - PCI-75-S
Max. Flow - 45 LPM, Vacuum - 27" Hg (680 mm)
Max. Pressure - 55 PSig, 1/4 HP
MACHEREY-NAGEL, the manufacturer of NUCLEOSIL HPLC phases and one of the leading companies forchromatography products, presents its Reversed Phase Application Guide.
The 160-page publication includes an introduction to the theoretical aspects of HPLC, a lot of information about
modern stationary phases, retention, selectivity and mobile phases.
Aside 150 up-to-date and relevant applications the special chapters Dos and Donts and trouble-shooting provide a lotof helpful hints and tips for a successful chromatography. A special sectionexplains basic aspects and demands of preparative HPLC.
The applications are divided in the fields of:
Drugs
Biological and natural compounds
Food analysis
Environmental analysis
Organic compounds
Polystyrene Calibration FilmsRadially Symmetric Polystyrene Calibration Films & Calibration Films Cast On KBr Windows( U.S. Patent No. 6, 254, 931-- Other Patents Pending)
Boron Doped KBr Calibration Windows(U.S. Patent No. 6, 594, 008)
PhEur 2.2.24 Calibration Standards
In addition to standard polystyrene calibration films, ICL offers several other calibration options. Superior calibrations are performed with radially symmetric films which eliminate the orientation effects of extruded films used for NIST Standard 1921 calibrations. This makes the films consistent from film to film. Sold in pairs of two (2) different film thickness, the differential between the absorbance intensities created by the two (2) film thickness becomes the baseline, thereby making the pair of films suitable both as an ordinate calibration standard useful for detection of degradation in instrument performance and for calibrating the abscissa scale in accordance with NIST Standard 1921. Films are available in free standing pairs mounted on 2 x 4 cards that fit in the standard universal slide mount in all spectrophotometers or the films can be cast on KBrwindows. Films cast on KBr windows will not exhibit any interference fringes. KBrwindows with films are sold with a mount with a 2 x 3 back plate that fits the standard universal slide mount in all spectrophotometers.The polystyrene coating prevents degradation of the KBrwindow from moisture effects. Boron doped crystal windows are also available as calibration standards. These windows can be matched in pairs with comparable absorbances.
Part No.
Description
0009-2500Polystyrene Test Film - 38 microns thick
0009-8181Polystyrene Test Film - 76 microns thick
0009-8182Pair of polystyrene calibration films of different thickness. One film is 38 microns and is provided with certification of traceability to five (5) NIST 1921b frequencies. The second film is 76 microns and is provided without certification. Both films are mounted on 2" x 3" cardstock holder with a 19mm aperture for mounting in the universal slide holder in all instruments. Includes instructions for two (2) film ordinate calibration and storage case. Also available with PhEur 2.2.24 certified polystyrene calibration film (inquire for quote).
0009-8487Same as 0009-8182, but with PhEur 2.2.24 certified films.
0009-7676NIST traceable Polystyrene Test film, certificate of traceability to five (5) NIST 1921b frequencies, set of 2 films each mounted to 2 x 4 cardstock holder
0009-7393Pair of polystyrene films of different thickness, both with NIST traceability certification. Kit also includes a pair of standard polystyrene films, but without NIST traceability certification. One NIST traceable film is mounted on 2" x 4" cardstock, which enables mounting in the standard universal slide mount found in all spectrophotometers, and is the same thickness as an NIST 1921 standard film (38 microns). The second thinner NIST traceable film is cast on KBr and includes holder and mounting device. Kit includes certification of traceability to five (5) NIST 1921b frequencies, radial symmetry certification for film cast on KBr and storage cases for all films.
0009-7394Pair of polystyrene calibration films of different thickness cast on KBr, radial symmetry certification, summary of NIST standard 1921 with frequency locations, certification of traceability to five (5) NIST 1921b frequencies, instructions for two (2) film ordinate calibration, slide mount holder. Kit also includes a pair of standard polystyrene films, without NIST traceability certification, mounted on 2" x 4" cardstock which enables mounting in the standard universal slide mount found in all spectrophotometers. Storage case provided.
0009-9247Pair of 13mm x 2mm KBr windows intended to fit FTIR microscope stage, coated with polystyrene and certified to five (5) NIST 1921b frequencies
0009-7395Single Boron doped KBr Crystal calibration standard with slide mount holder and storage case. (U.S. Patent No. 6, 594, 008)
0009-7396Pair of matched Boron doped KBr windows.(U.S. Patent No. 6, 594, 008)
0009-8157Polystyrene calibration film for PhEur 2.2.24 calibration of IR and FTIR instruments, certified to 7 wave-numbers and certified as to absorption minima and maxima differentials at 2870 cm-1and 2849.5cm-1and at 1589 cm-1and 1583 cm-1.
0009-8158Pair of PhEur 2.2.24 certified polystyrene calibration films, same as 0009-8157 but with 2 certified films.
0009-8559Polystyrene Calibration film for PhJap 2.25 calibration of IR and FTIR instruments, certified to 7 wave numbers, mounted on 2" x 4" card stock.
0009-8558Pair of PhJap 2.25 certified polystyrene calibration films, same as 0009-8559 but with 2 certified Films.
0009-8560Polystyrene calibration film, certificate of traceability to seven (7) NIST frequencies (wave numbers) and certified as to absorption minima and maxima differentials at 2870cm-1 and 2849.5cm-1 and 1589cm-1 and 1583cm-1 as required by PhEur 2.2.24.
0009-8448Polystyrene calibration film, certificate of traceability to seven (7) NIST frequencies (wave numbers) and certified as to absorption minima and maxima differentials at 2870cm-1 and 2849.5cm-1 and 1589cm-1 and 1583cm-1 as required by PhEur 2.2.24 and also certified to PhJap 2.25.
0009-8437Pair of films same as 0009-8448
0009-9248Custom Cut Polystyrene film cut to the size of any Horizontal ATR accessory (please specify, up to 4" square), certified to five (5) NIST 1921b frequencies
The recirculating chillers are designed to handle high coolingcapacities. These chillers operate in the temperature range from+5C to atmosphere and have built in high pressure pump. Thesechillers are useful to cool other instruments which generate heat.Viz. Lasers, Furnaces, XRD, etc., Graphite Furnace, Fermenters, Thermal Instruments, Rotary Evaporator.
Water Chiller Unit:It consists of chilled water storage tank of about8-15 liters capacity along with Compressor, Condensing Coils, Cooling Fan, Temperature Controller Programable type, Water Inlet& Outlet connection and chilled water circulation pump to circulatechilled water through S.S. cooling coils and bring back to chiller tank.Control Panel consists of temperature & ready status of ChillerON/OFF Switch, with Red Coloured Indicator Green colouredindicator which indicates Initial Power ONThis has an Inbuilt delay of about 1-2 minutes for the Compressorto be ON.Switch for Chilled Water circulation pump. This has no time delay.This is fitted in a Floor Mounting type with Castor Wheels(optional).
Gas Distribution PanelGas distribution panel is used when there is more than one Gas Chromatograph.It helps to controlled the flow & pressure of different gases for different GC's.Available in three different types. One is with pressure gauge, pressure regulator, ON/OFF valve. Second with pressure gauge and ON/OFFvalve.Third is with onlyON/OFF valve.
Gas Selector BoxUsed for the selection between two gases of different types.Available in two different types one with selector valve, pressure gauge & togglevalve, another with only two toggle valve.