Our Products
Pc cab offers an array of products that are safe and are flame retardant. Our products are absolutely immune to fires, short circuits or electric shocks. We always use premium quality of raw materials to ensure that our products ensure durability and a safe wiring for buildings. Features: superior tensile strength high efficiency good insulation property ability of withstanding high temperatures abrasion resistance properties reliability ductility applications: commercial buildings residential buildings qty box : 90 meters.
Single Core PVC Unsheathed Electrolytic Copper Industrial | |||||
---|---|---|---|---|---|
Flexible Cables UP to 1100 V. Generally Conforming To IS 694:1990 | |||||
Nominal c/s Area of Conductor In Sq. mm. | Conductor Construction No. / mm. | Nominal Insulation Thickness In mm. | Approx. Overall Diameter In mm. | Current Rating At 40°C in Amps. (#) | Max. D/C Resistance Per. Km. @ 20°C Ohm. / Km. (*) |
6.00 | 84/0.30 | 0.9 | 5.3 | 31 | 3.08 |
10.00 | 140/0.30 | 1.0 | 6.7 | 42 | 1.83 |
i 6.00 | 225/0.30 | 1.0 | 8.1 | 57 | 1.15 |
25.00 | 354/0.30 | 1.2 | 10.0 | 72 | 0.727 |
35.00 | 490/0.30 | 1.2 | 11.5 | 90 | 0.524 |
50.00 | 700/0.30 | 1.4 | 13.0 | 115 | 0.387 |
Our flexible cables are used in diverse industrial applications where high voltage maintenance is required.
Features
Applications
Number of Cores | Nominal Thickness Of Insulation mm. | Min. Thickness of Inner Sheath mm. | Armour | Nominal Sheath Thickness unarmoured mm. | Nominal Sheath Thickness Armoured mm. | Approx. Overall Diameter | Approx. Weight of Cable | Max. DC Conductor Resistance at 20 C Ohm. Km. | Current Ratings | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Galv. Round Steel Wire Nom. Dia. mm. | Galv. Flat Steel Strip Nom. Thick mm. | Unarm oured mm. | Armoured Armoured mm. | Unarm oured mm. | Armoured mm. | Direct Ground Amps | In Ducts Amps | In Air Amps | ||||||
2 | 0.8 | 0.3 | 1.4 | - | 1.80 | 1.24 | 11.5 | 14.0 | 130 | 350 | 12.1 | 23 | 20 | 20 |
3 | 0.8 | 0.3 | 1.4 | - | 1.80 | 1.24 | 12.0 | 14.5 | 160 | 400 | 12.1 | 21 | 17 | 17 |
4 | 0.8 | 0.3 | 1.4 | - | 1.80 | 1.24 | 13.0 | 15.0 | 190 | 450 | 12.1 | 21 | 17 | 17 |
5 | 0.8 | 0.3 | 1.4 | - | 1.80 | 1.24 | 14.0 | 16.0 | 225 | 500 | 12.1 | 16 | 14 | 14 |
6 | 0.8 | 0.3 | 1.4 | - | 1.80 | 1.24 | 15.0 | 17.0 | 250 | 550 | 12.1 | 15 | 13 | 13 |
7 | 0.8 | 0.3 | 1.4 | - | 1.80 | 1.24 | 15.0 | 17.0 | 265 | 565 | 12.1 | 14 | 13 | 13 |
10 | 0.8 | 0.3 | 1.4 | - | 1.80 | 1.40 | 18.0 | 20.5 | 350 | 750 | 12.1 | 13 | 11 | 11 |
12 | 0.8 | 0.3 | - | 0.8 | 1.80 | 1.40 | 18.5 | 19.5 | 400 | 650 | 12.1 | 12 | 10 | 10 |
14 | 0.8 | 0.3 | - | 0.8 | 1.80 | 1.40 | 18.5 | 20.5 | 450 | 760 | 12.1 | 12 | 10 | 10 |
16 | 0.8 | 0.3 | - | 0.8 | 1.80 | 1.40 | 20.5 | 21.5 | 500 | 800 | 12.1 | 11 | 9 | 9 |
19 | 0.8 | 0.3 | - | 0.8 | 2.00 | 1.40 | 22.0 | 22.5 | 600 | 850 | 12.1 | 10 | 9 | 9 |
24 | 0.8 | 0.3 | - | 0.8 | 2.00 | 1.40 | 25.0 | 25.5 | 725 | 1050 | 12.1 | 9 | 8 | 8 |
30 | 0.8 | 0.3 | - | 0.8 | 2.00 | 1.40 | 26.0 | 27.5 | 860 | 1200 | 12.1 | 9 | 7 | 7 |
37 | 0.8 | 0.3 | - | 0.8 | 2.00 | 1.40 | 28.0 | 28.5 | 1050 | 1400 | 12.1 | 8 | 7 | 7 |
61 | 0.8 | 0.4 | - | 0.8 | 2.00 | 1.56 | 35.0 | 36.5 | 1650 | 2100 | 12.1 | 7 | 6 | 6 |
This cable is manufactured by maintaining highest level of quality parameters from its raw material till final testing. Ec grade copper & 100 % virgin pvc material are key input factor for our submersible pump cable, strong quality check at every stage of manufacturing makes our submersible flat cable a safest in this segment. Applications aquariums sewage treatment plants water supply plants irrigation industry deep boring wells
3 Core PVC Submersible Flat Copper Conductor Cable Up To 1100 V. As PER Is 694: 1990 | ||||||||
---|---|---|---|---|---|---|---|---|
Conductor | PVC Insulation | PVC Sheath | Current Rating At 40°C In Amps. | Max. D/C Resistance @ 20°C Ohm. / Km. | ||||
Nominal c/s Area Of Conductor In Sq. mm. | Conductor Construction No. / mm. | Nominal Insulation Thickness in mm. | Approx. Core Dia. In mm. | Nominal Thickness In mm. | Overall Dimensions | |||
Height mm. | Width mm. | |||||||
1.00 | 14/0.3 | 0.7 | 2.7 | 0.9 | 5.00 | 10.40 | 11 | 18.10 |
1.50 | 22/0.3 | 0.7 | 3.2 | 0.9 | 5.40 | 12.00 | 14 | 12.10 |
2.50 | 36/0.3 | 0.8 | 3.6 | 1.0 | 6.10 | 13.85 | 18 | 7.41 |
4.00 | 56/0.3 | 0.8 | 4.2 | 1.1 | 7.15 | 15.80 | 26 | 4.61 |
6.00 | 84/0.3 | 0.9 | 5.3 | 1.2 | 8.20 | 18.90 | 31 | 3.08 |
10.00 | 140/0.3 | 1.0 | 6.7 | 1.4 | 10.30 | 23.60 | 42 | 1.83 |
16.00 | 225/0.3 | 1.0 | 8.0 | 1.4 | 12.40 | 27.50 | 57 | 1.15 |
25.00 | 354/0.3 | 1.2 | 10.2 | 2.0 | 15.70 | 36.50 | 72 | 0.727 |
35.00 | 490/0.3 | 1.2 | 11.7 | 2.0 | 17.20 | 40.50 | 90 | 0.524 |
50.00 | 700/0.3 | 1.4 | 13.9 | 2.2 | 19.30 | 46.50 | 115 | 0.387 |
Conductors : highly tensile solid aluminium conductor as per class 1 class 2 of is: 81301984 insulation : pvc type a as per is:58311984, cores are laid side by side. Outer sheath: pvc type st1 as per is:81301984 range: 2.5 sq mm to 10.0 sq mm in aluminum.
PVC INSULATED AND SHEATHED TWIN FLAT ALUMINIUM CABLES UP TO 1100 V. CONFORMING TO IS 694: 1990 | ||||||||
---|---|---|---|---|---|---|---|---|
CONDUCTOR | PVC INSULATION | PVC SHEATH | Current Rating At 40°C In Amps. | Max. D/C Resistance @ 20°C Ohm. / Km. | ||||
Nominal c/s Area Of Conductor In Sq. mm. | Conductor Construction No. / mm. | Nominal Insulation Thickness in mm. | Approx. Core Dia. In mm. | Nominal Thickness In mm. | Max. Overall Dimensions | |||
Height mm. | Width mm. | |||||||
2.50 | 1/1.78 | 0.7 | 3.3 | 1.0 | 6.40 | 10.00 | 18 | 12.10 |
4.00 | 1/2.25 | 0.8 | 3.8 | 1.0 | 7.20 | 11.50 | 23 | 7.41 |
6.00 | 1/2.76 | 0.8 | 4.5 | 1.1 | 8.00 | 13.00 | 30 | 4.61 |
10.00 | 1/3.57 | 1.0 | 5.5 | 1.2 | 16.00 | 16.00 | 40 | 3.08 |
Multicore cables offer flexibility through the use of fine copper wire stranding and pliable pvc compounds. This cables are ideal for use on portable or movable equipment or where flexibility will make installation considerably easier.
Variants
Applications
MULTI CORE PVC. INSULATED & SHEATHED ROUND FLEXIBLE COPPER CABLES UP TO 1100 V. AS PER IS 694: 1990 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Nominal c/s Area Of Conductor In Sq. mm. | Conductor Construction No. / mm. | Nominal Insulation | Approx. Core Dia. In Thickness mm. in mm. | Outer Sheath Nominal Thickness In mm. | Max. Overall Dia. In mm. | Current Rating At 40°C in Amps. | Max. D/C Resistance @ 20°C Ohm. / Km. | ||||
2 CORE | 3 CORE | 4 CORE | 2 CORE | 3 CORE | 4 CORE | ||||||
0.50 | 16/.2 | 0.6 | 2.3 | 0.9 | 0.9 | 0.9 | 7.2 | 7.6 | 8.2 | 4 | 39.00 |
0.75 | 24/.2 | 0.6 | 2.5 | 0.9 | 0.9 | 0.9 | 7.8 | 8.2 | 8.8 | 7 | 26.00 |
1.00 | 32/.2 | 0.6 | 2.7 | 0.9 | 0.9 | 0.9 | 8.0 | 8.6 | 9.4 | 11 | 19.50 |
1.50 | 22/.3 | 0.6 | 3.1 | 0.9 | 0.9 | 0.9 | 8.8 | 9.2 | 10.0 | 14 | 12.10 |
2.50 | 36/.3 | 0.7 | 3.6 | 1.0 | 1.0 | 1.0 | 10.5 | 11.0 | 12.0 | 18 | 7.41 |
4.00 | 56/.3 | 0.8 | 4.2 | 1.0 | 1.1 | 1.1 | 12.0 | 12.5 | 14.0 | 26 | 4.95 |
6.00 | 84/.3 | 0.9 | 5.3 | 1.1 | 1.1 | 1.2 | 13.5 | 14.5 | 15.5 | 31 | 3.08 |
10.00 | 140/.3 | 1.0 | 6.7 | 1.2 | 1.2 | 1.3 | 16.5 | 117.5 | 19.5 | 42 | 1.83 |
16.00 | 225/.3 | 1.0 | 8.0 | 1.3 | 1.3 | 1.4 | 19.0 | 20.0 | 22.5 | 57 | 1.15 |
25.00 | 354/.3 | 1.2 | 9.8 | 1.4 | 1.5 | 1.6 | 23.0 | 24.5 | 27.5 | 72 | 0.727 |
PC-CAB has gained the expertise needed to offer a range of control cables, LT cables and XLPE cables to the domestic as well as overseas market.
Our product is made up of premium material to ensure a greater durability and quality.
Applications
ominal area of Conductor Sq. mm. | Form of Conductor Main Neutral | Resistance of Conductor M. Neutral ohm/km | Nominal thickness of insulation mm | Nominal thickness of inner Sheath mm | UNARMOURED | ROUND WIRE ARMOURED | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
Nominal thickness of Outer Sheath mm | Approx overall diameter of cable mm | Approx weight of cable mm | Nominal Diameter of Round Wire STEEL STRIP mm | Minimum thickness of Outer Sheath mm | Approx. overall diameter of cable mm | Approx. weight of cable kg/km | |||||
For Cores | |||||||||||
1.5 | Solid Circular | 18.10 | 0.8 | 0.3 | 1.24 | 9.50 | - | 1.4 | 1.24 | 12.2 | 320 |
2.5 | Solid | 12.10 | 0.9 | 0.3 | 1.24 | 10.60 | - | 1.4 | 1.24 | 13.4 | 380 |
4 | “ | 7.41 | 1.00 | 0.30 | 1.80 | 14.25 | 250 | 1.40 | 1.24 | 16.00 | 525 |
6 | “ | 4.61 | 1.00 | 0.30 | 1.80 | 15.75 | 300 | 1.40 | 1.24 | 17.25 | 600 |
10 | “ | 3.08 | 1.00 | 0.30 | 1.80 | 17.50 | 400 | 4 x 0.8 | 1.40 | 18.25 | 600 |
16 | Stranded | 1.91 | 1.00 | 0.30 | 2.00 | 20.25 | 450 | “ | 1.40 | 21.00 | 700 |
Three Half cores | |||||||||||
25 16 | Sector Shaped | 1.2 1.91 | 1.2 1.00 | 0.3 | 2,00 | 22,65 | 600 | 4 x 0.8 | 1.4 | 22.00 | 850 |
35 16 | “ | 0.868 1.91 | 1.2 1.00 | 0.3 | 2.00 | 24.75 | 825 | “ | 1.4 | 24.00 | 1000 |
50 25 | “ | 0.641 1.20 | 1.4 1.20 | 0.3 | 2.00 | 28.50 | 925 | “ | 1.56 | 28.25 | 1450 |
70 35 | “ | 0.443 0.868 | 1.4 1.20 | 0.4 | 2.20 | 31.50 | 1175 | “ | 1.56 | 31.25 | 1675 |
95 50 | “ | 0.320 0.641 | 1.6 1.40 | 0.4 | 2.20 | 34,75 | 1650 | “ | 1.56 | 35.50 | 2100 |
120 70 | “ | 0.253 0.443 | 1.6 1.40 | 0.4 | 2.20 | 36.00 | 2000 | “ | 1.72 | 38.50 | 2525 |
150 70 | “ | 0.206 0.443 | 1.8 1.40 | 0.5 | 2.40 | 43.00 | 2400 | “ | 1.72 | 42.75 | 3000 |
185 95 | “ | 0.164 0.320 | 2.0 1.60 | 0.5 | 2.60 | 47.50 | 3000 | “ | 1.88 | 47.20 | 3450 |
240 120 | “ | 0.125 0.253 | 2.2 1.60 | 0.6 | 2.80 | 53.25 | 3700 | “ | 2.04 | 53.00 | 4450 |
300 150 | “ | 0.100 0.206 | 2.4 1.80 | 0.6 | 3.00 | 59.75 | 4700 | “ | 2.20 | 58.50 | 5450 |
400 185 | “ | 0.0778 0.164 | 2.6 2.00 | 0.7 | 3.20 | 66.50 | 5900 | “ | 2.52 | 65.75 | 6750 |
PC-CAB has gained the expertise needed to offer a range of control cables, LT cables and XLPE cables to the domestic as well as overseas market.
Our product is made up of premium material to ensure a greater durability and quality.
We create supreme quality of auto cables that are perfectly suitable for use in automotive industries. We are supplying auto cables and battery cables with lugs soldered or crimped, immediately ready for use. Features precision-engineered using latest machineries use of bright annealed 99.97% pure bare copper conductors resistant to low conductors special grade pvc compound formulation resistant to moisture, oils, grease and acids. applications automobiles power computer back-ups wind energy farms tele communications
Features
Applications
AREA | No & Size of wire (nom) | Conductor max resistance @ 20 c | Current rating DC of AC | Insulation thickness (nom) | Unsheathe overall diameter |
---|---|---|---|---|---|
Sq. mm | mm | Ohm/km | Amp | mm | mm |
0.50 | 16/.20 | 39 | 4 | 0.6 | 2.3 |
0.75 | 24/.20 | 26 | 7 | 0.6 | 2.5 |
1.00 | 14/0.30 | 18.1 | 12 | 0.6 | 2.75 |
1.50 | 22/0.30 | 12.1 | 15 | 0.6 | 2.95 |
2.50 | 36/0.30 | 7.41 | 20 | 0.7 | 3.36 |
4.00 | 56/.30 | 4.95 | 27 | 0.8 | 4.3 |
6.00 | 84/.30 | 3.3 | 35 | 0.8 | 5.5 |
10.00 | 80/.40 | 1.91 | 46 | 1 | 6.8 |
16.00 | 126/.40 | 1.21 | 62 | 1 | 8.2 |
25.00 | 196/.40 | 0.78 | 80 | 1.2 | 10 |
35.00 | 276/.40 | 0.55 | 102 | 1.2 | 11.2 |
50.00 | 396/.40 | 0.39 | 138 | 1.4 | 13.5 |
PC-CAB offers an array of products that are safe and are flame retardant. our products are absolutely immune to fires, short circuits or electric shocks. We always use premium quality of raw materials to ensure that our products ensure durability and a safe wiring for buildings.
FeaturesQty / Box :90 Meters
Test | Specification | Specified Value |
---|---|---|
Critical oxygen index | ASTM-D-2863 | Oxygen index min-29% |
Temperature Index | ASTM-D 2863 & BICC Hand Book Chapter No. 6 | Minimum Temperature Index 250 •C |
Single Core PVC Unsheathed Electrolytic Copper Industrial | |||||
---|---|---|---|---|---|
Flexible Cables UP to 1100 V. Generally Conforming To IS 694:1990 | |||||
Nominal c/s Area of Conductor In Sq. mm. | Conductor Construction No. / mm. | Nominal Insulation Thickness In mm. | Approx. Overall Diameter In mm. | Current Rating At 40°C in Amps. (#) | Max. D/C Resistance Per. Km. @ 20°C Ohm. / Km. (*) |
6.00 | 84/0.30 | 0.9 | 5.3 | 31 | 3.08 |
10.00 | 140/0.30 | 1.0 | 6.7 | 42 | 1.83 |
i 6.00 | 225/0.30 | 1.0 | 8.1 | 57 | 1.15 |
25.00 | 354/0.30 | 1.2 | 10.0 | 72 | 0.727 |
35.00 | 490/0.30 | 1.2 | 11.5 | 90 | 0.524 |
50.00 | 700/0.30 | 1.4 | 13.0 | 115 | 0.387 |
We provide an exclusive range of unarmored 3 core and 4 core double sheathed single solid aluminum cables. We also manufacture aluminium twin flat cables from 2.5 sq mm to 10.0 sq mm in aluminum.
Nominal c/s Area Of Conductor In Sq. mm. | Conductor Construction No. / mm. | Nominal Insulation Thickness in mm. | Approx. Core Dia. In mm | Outer Sheath Nominal Thickness In mm. | Max. Overall Dia. In mm. | Current Rating At 40°C in Amps. | Max. D/C Resistance @ 20°C Ohm. / Km. | ||
---|---|---|---|---|---|---|---|---|---|
3 CORE | 4 CORE | 3 CORE | 4 CORE | ||||||
4.00 | 1/2/1925 | 0.8 | 3.8 | 1.1 | 1.1 | 11.4 | 13.0 | 23 | 7.41 |
6.00 | 1/2/1976 | 0.8 | 4.5 | 1.1 | 1.2 | 12.8 | 14.0 | 30 | 4.61 |
10.00 | 1/3/1957 | 1.0 | 5.5 | 1.2 | 1.3 | 14.4 | 17.0 | 40 | 3.08 |
16.00 | 1/4/1950 | 1.1 | 6.7 | 1.3 | 1.4 | 17.6 | 21.0 | 51 | 1.91 |
25.00 | 7/2/2013 | 1.2 | 8.1 | 1.5 | 1.6 | 24.5 | 27.5 | 70 | 1.20 |