Our Product / Services
Battery Chargers
2 Products availableTransportation, Logistics & Air Freight Services
2 Products / Services availableMobile Charger
1 Products availableThyristor
1 Products availableElectrical Panels & Distribution Box
1 Products availableElectrical & Electronic Gadgets
1 Products availableVoltage Stabilizer
1 Products availableProduct Inspection & Quality Checking Services
1 Services availableAuditing Services
1 Services availableWe are leaders in the market for providing best range of Textiles Weaving Industries Solution, FMCG Industries Solution, Pharma / Chemical Industries Solution, IT / ITES Industries Solution and ARC Flash Study Service
Model: Lite/ Basic/Ultra
Input Power- 3.3kW, 7.2kW/11kW, 22kW
Input Voltage- 230V AC single phase/415V AC 3 Phase
Communication: Wifi, BT, RS485, LAN/4G/OCPP 1.6V
Additional Information:
Payment Terms :
Delivery Time : 2-3 weeks
Features
Benefits
Technical Specifications
Description | Three phase, dry, impregnated, magnetic circuit | |||
---|---|---|---|---|
Type | Iron core | |||
Material Type | Aluminium | Copper | ||
Relative Impedance | 5.67% | 7.00% | 14.00% | |
Ratings (in kVAR) | 10, 12.5, 15, 20, 25, 50, 75, 100, higher on request | |||
Degree of Protection | IP00 | |||
Insulation class | Class H | |||
Linearity | 175% (standard) and 200% on request | |||
Rated voltage | 400 to 690V - 50Hz | |||
Inductance tolerance per phase | (+/-) 2.5% | |||
Insulation level | upto 1.1kV | |||
Thermal Protection | Dry contact normally closed, 250VAC 2A | |||
Cooling requirement | Forced Air | |||
Standards | IS 5553 - 1990 | |||
OPERATING CONDITIONS | ||||
Use | Indoor | |||
Storage Temp | (-)40 degC to 60 degC | |||
Relative Humidityt | upto 80% | |||
Operating Temperature | upto 55 degC ambient | |||
Altitude | upto 1000m |
Download Product Brochure
We often custom engineer products for applications with unique requirements. Our range of custom solutions include the following
Typical Challenges
Root Cause Analysis
Solution
Benefits
P2 Power Active Filter effectively reduced high harmonic distortion and neutral current at PCC realizing following overall benefits:
Typical Challenges
Root Cause Analysis
Solution
Benefits
Typical Challenges
Root Cause Analysis
Solution
Benefits
Typical Challenges
Root Cause Analysis
Solution
Benefits
Typical Challenges
Root Cause Analysis
Solution
Benefits
Typical Challenges
Root Cause Analysis
Solution
Benefits
Typical Challenges
Root Cause Analysis
Solution
Benefits
Typical Challenges
Root Cause Analysis
Solution
Benefits
Typical Challenges
Root Cause Analysis
Solution
Benefits
Features
Benefits
Technical Specifications
Capacity | upto 3500kVA | ||
---|---|---|---|
Input Voltage range | As per customer requirement | ||
Output Voltage | Settable 380-415V +/- 1% | ||
Input frequency | 47-53 Hz | ||
Correction speed | 75V/sec | ||
Control type | Digital control | ||
Alarm | Audio in case of trip | ||
Waveform distortion | Nil | ||
Efficiency | >98% | ||
Nature of cooling | ONAN | ||
Protections | |||
ENVIRONMENT | |||
Protection Class | |||
Operating Temperature | 0-45degC | ||
Operating Environment | |||
Relative Humidity | Maximum 95% (non condensing) | ||
Altitude | Upto 1000m |
Download Product Brochure
Features
Benefits
Technical Specifications
Models | p2p-415-apf3 | p2p-415-apf4 | ||
---|---|---|---|---|
Network Voltage | 415Urms +10%/-15% | |||
Connection | 3P/4W | 4P/4W | ||
Grid Frequency | 50Hz +/-5% (60Hz available on request) | |||
Modularity | Upto 32 units | |||
Harmonic Filtering | 2nd to 51st order | |||
Individual Harmonic Selection | Yes | |||
Harmonic Attenuation | >96% | |||
Reactive Compensation | Yes | |||
Negative Sequence Compensation | Yes | Yes | ||
Zero Sequence Compensation | NA | Yes | ||
Compensation | Open/Closed Loop | |||
Reaction Time | <100 micro seconds | |||
Filter Consumption | <3.0% of rated capacity (typical) | |||
CT Specifications | ratio based on peak load | 0.5 class or better | 15VA or more | |
Standards | IEEE 519-1992 harmonic standards | |||
USER INTERFACE | ||||
Interface | 7" touch screen | |||
Remote Interface | Ethernet, MODBUS RTU | |||
Configuration Settings | Through User Interface and USB key | |||
ENVIRONMENT | ||||
Protection Class | IP41 (Higher on request) | |||
Operating Temperature | upto 45 degrees with adequate ventilation (upto 55 degrees with derating) | |||
Operating Environment | Indoor, Dust Free | |||
Relative Humidity | Maximum 95% (non condensing) | |||
Altitude | Upto 1000m |
Download Product Brochure
Features
Benefits
Technical Specifications
Model | p2p-415-apf3T | |||
---|---|---|---|---|
Network Voltage | 415Urms +10%/-15% | |||
Switching Architecture | NPC-2 Architecture | Advanced RCT snubber with Active Damping | ||
Connection | 3P/4W | |||
Grid Frequency | 50Hz +/-5% (60Hz available on request) | |||
Modularity | Upto 32 units | |||
Harmonic Filtering | 2nd to 51st order | |||
Individual Harmonic Selection | Yes | |||
Harmonic Attenuation | >98% | |||
Reactive Compensation | Yes | |||
Negative Sequence Compensation | Yes | |||
Compensation | Open/Closed Loop | |||
Reaction Time | <50 micro seconds | |||
Filter Consumption | <2.0% of rated capacity (typical) | |||
CT Specifications | ratio based on peak load | 0.5 class or better | 15VA or more | |
Standards | IEEE 519-1992 harmonic standards | |||
USER INTERFACE | ||||
Interface | 7" touch screen | |||
Remote Interface | Ethernet, MODBUS RTU | |||
Configuration Settings | Through User Interface and USB key | |||
ENVIRONMENT | ||||
Protection Class | IP41 (Higher on request) | |||
Operating Temperature | upto 45 degrees with adequate ventilation (upto 55 degrees with derating) | |||
Operating Environment | Indoor, Dust Free | |||
Relative Humidity | Maximum 95% (non condensing) | |||
Altitude | Upto 1000m |
Download Product Brochure
Features
Benefits
Technical Specifications
Models | p2p-575-apf3M | p2p-690-apf3M | ||
---|---|---|---|---|
Network Voltage | 575Urms +10%/-15% | 690Urms +10%/-15% | ||
Connection | 3P/3W | |||
Grid Frequency | 50Hz +/-5% (60Hz available on request) | |||
Modularity | Upto 32 units | |||
Harmonic Filtering | 2nd to 51st order | |||
Individual Harmonic Selection | Yes | |||
Harmonic Attenuation | >98% | |||
Reactive Compensation | Yes | |||
Negative Sequence Compensation | NA | Yes | ||
Compensation | Open/Closed Loop | |||
Reaction Time | <50 micro seconds | |||
Filter Consumption | <2.0% of rated capacity (typical) | |||
CT Specifications | ratio based on peak load | 0.5 class or better | 15VA or more | |
Standards | IEEE 519-1992 harmonic standards | |||
USER INTERFACE | ||||
Interface | 7" touch screen | |||
Remote Interface | Ethernet, MODBUS RTU | |||
Configuration Settings | Through User Interface and USB key | |||
ENVIRONMENT | ||||
Protection Class | IP41 (Higher on request) | |||
Operating Temperature | upto 45 degrees with adequate ventilation (upto 55 degrees with derating) | |||
Operating Environment | Indoor, Dust Free | |||
Relative Humidity | Maximum 95% (non condensing) | |||
Altitude | Upto 1000m |
Download Product Brochure
Features
Benefits
Technical Specifications
Models | p2p-415-hypfc3 | p2p-415-hypfc4 | |
---|---|---|---|
Network Voltage | 415Urms +10%/-15% | ||
Connection | 3P/4W | 4P/4W | |
Grid Frequency | 50Hz +/-5% (60Hz available on request) | ||
Reactive Lag Compensation | Full | ||
Reactive Lead Compensation | Limited | ||
Harmonic Compensation | Limited | ||
Harmonic Filtering | 2nd - 25th order | ||
Individual Harmonic Selection | Yes | ||
Negative Sequence Compensation | Limited | ||
Zero Sequence Compensation | NA | Yes (Limited) | |
Compensation | Closed Loop | ||
Reaction Time | <150 micro seconds | ||
Filter Consumption | <2.0% of rated capacity (typical) | ||
CT Specifications | ratio based on peak load | 0.5 class or better | 15VA or more | ||
Standards | IEEE 519-1992 harmonic standards | ||
USER INTERFACE | |||
Interface | 7" touch screen | ||
Remote Interface | Ethernet, MODBUS RTU | ||
Configuration Settings | Through user interface & USB key | ||
ENVIRONMENT | |||
Protection Class | IP41 (Higher on request) | ||
Operating Temperature | upto 45 degrees with adequate ventilation (upto 55 degrees with derating) | ||
Operating Environment | Indoor, Dust Free | ||
Relative Humidity | Maximum 95% (non condensing) | ||
Altitude | Upto 1000m |
Download Product Brochure
Since incorporation in 2006, P2 Power Solutions Pvt. Ltd. has been rendering a variety of power quality services. We operate from Noida (Uttar Pradesh, India) and render end-to-end solutions by examining the system, locating the source of problem and making appropriate corrections to make your system run at its peak efficiency. We charge reasonably for our services. So, turn to our services and enhance the efficiency & reliability of your facility.
P2 Power Solutions Pvt. Ltd. is a bankable name when it comes to energy audit. The company is based in Noida (Uttar Pradesh, India) and we have been serving energy requirements of the clients since 2006. With our services, we establish pattern of energy use; identity how & where loses are occurring. Based on this data, we suggest engineering solutions to enhance energy efficiency in the system studied. So, to schedule an appointment with us, ring us on the given numbers.
Thermography is a technique that is used for analyzing the characteristics of an object from its infrared image. Thermography allows us to see heat energy radiated by objects. SO, if you are seeking professional support for conducting thermography study of any object, look no further than P2 Power Solutions Pvt. Ltd. We are based in Noida (Uttar Pradesh, India) and we render precise solutions complying with the codes of the industry. So, share your needs and requirements, we assure to attain optimum quotients.
Arch flash is the very high temperature discharge that is produced by an electrical fault like short circuit fault, or abrupt failure of an insulator. This high temperature can be dangerous for the worker’s health. If you are seeking professional support for arc flash study, contact only. At P2 Power Solutions Pvt. Ltd., we are a group of engineers and trained professionals with arc flash analysis software at their fingertips. With our services, we conduct arc flash hazard assessment and determine the arc flash boundary & risk category. To schedule an appointment, reach us through our contact us page. We are based in Noida (Uttar Pradesh, India).
Micro inverter is a plug-and-play device. It is meant to convert direct current into alternating current. If you are seeking professional support for micro inverter solutions, look no further than P2 Power Solutions Pvt. Ltd. The company is based in Noida (Uttar Pradesh, India) and we provide solutions keeping the client’s functional needs in mind. Whether you seek solutions for micro inverter designing, operations, maintenance or repairing works, we provide solutions for everything. So, contact us anytime.
P2 Power Solutions Pvt. Ltd. is a bankable name, involved in providing custom solar solutions to clients across the nation. We are based in Noida (Uttar Pradesh, India) and we render personalized solutions for solar panel, plants, and products among others. Our work diligence and dedication towards complete client satisfaction are the reasons behind our worldwide recognition.
With our services, we work on the provided details and make use of modern work methods to render precise solutions.
We are a renowned name, offering fully-integrated solutions for a variety of solar EPC works. At P2 Power Solutions Pvt. Ltd., we are a group of individuals, who work together to provide end-to-end solutions. With our services, we take care of engineering & design, manufacturing, material procurement, project management and commissioning. Besides, we provide solutions for operation & maintenance on demand. The company is based in Noida (Uttar Pradesh, India) and we customize our services as per the individual’s functional needs. So, contact us anytime.
It allows compensation of very high fluctuating reactive power demand. This system uses switching algorithm to toggle On/Off capacitor groups for required compensation with connection and disconnection of capacitor to and from the network at active zero potential crossing even in presence of harmonics.
Additional Information:
Payment Terms :
Delivery Time : 4-5 weeks