APT2000 : SMART Temperature Transmitter

  • Type : Temperature Transmitter
  • Accuracy : ±0.075% of F.S
  • Output : 4 - 20mA; HART Superimposed
  • Model : APT2000
  • Temperature Range : -200 to 1800°C
  • Power Supply : 12 - 36V DC

Food & beverage, pharmaceutical, chemical & petrochemical industries, conventional & nuclear plants, pumps, presses, turbines, hydro-cleaning machines, diesel engines & refrigerating plants.

Special Features :
Programmable Input (Pt-100 / Thermocouple / Variable Resistance)
Linear Signal Output
Current Loop Powered
LCD Display with Bargraph
High Performance; High Reliability

Input : Thermocouple / RTD / mV
Output : 4 - 20 mA, Super Imposed HART
Accuracy : ±0.075% of the calibrated span
Operating Temp. : -40°C to 85°C
Calibration   Settable via HART Protocol / Onboard Buttons
Display Range : -19999 to 99999
Housing : Diecast Aluminium
Power Supply : 24V DC nominal (10.5 to 45)V DC
Load Resistance : Max. (V Power Supply - 10.5V) / 0.022A
Protection : Intrinsically Safe: Exia II CT4
View Complete Details

Temperature Transmitters

We deals in manufacturing and supplying of wide range of Temperature Transmitters.
View Complete Details

Differential Pressure Transmitters

  • Power Supply 24Vdc
  • Pressure Unit M11 / Pa, mmH2O, mbar, inWG,
This transmitter is apply to low differential pressure display and signal collection in HVAC, industrial equipment, intelligent building, test bench and other fields.Housing with simplified mounting systems.
View Complete Details

SGT45 : VOC GAS TRANSMITTER

  • Range 0 to 100% LEL
  • Accuracy  ± 1.5% of F.S
  • Parameter : COMBUSTIBLE
  • Mounting Wall
  • Display  Optional
  • Output  4 - 20mA

High accuracy and better lifetime achieved using photo Ionization Detection(PID) sensor Technology

Optimized for detection of smallest leak of VOCs (IP View Complete Details

SGT35: SMART GAS TRANSMITTER FOR TOXIC / COMBUSTIBLE GASES

  • Range 3 Bar ~ 2000 Bar
  • Accuracy  ±0.25%
  • Parameter TOXIC GASES
  • Display Optional
  • Output  4-20 mA , 0-10V , 0-5V, 0.5-4.5V Ratiometric, 1-5V

Refineries, Sewage Plants, Fertilizers Plants, Stack Monitoring, Gas Cylinder Bank, Ambient Monitoring, Pulp and Paper plants. Oil and Gas Industries, Gas Pipeline projects, as Metering Station, Heat Treatment Plants, Automotive Industries, Chemical Storage Area, Burner / Furnace Area, Power and Industrial Plant, Bullet Yard / Storage Yard, Chemical Processing Plants, Coal Mine and Confined Area, Offshore Drilling & Processing, Chemical & Petrochemical Plants, Acid Alkalizes & Dyes Mfg. Plants

Special Features :
Highly resistant to poisoning and etching
Capable of detecting down to PPM, %LEL & %V/V.
Digital display of gas concentration on Seven Segmet Display
Standard 4-20mA signal output with configurable range
Easy handling and programming with 3 keys
Can be programmed using Remote Control from 10 meters in line of site distance
Non-intrusive programming for Flameproof model using Magnetic pen
Password protected programming with password changing facility
One man auto software Gas Calibration
Optional STEL and TWA set points can be configured for Toxic Gases
Optional RS-485 communication port with MOBDUS RTU Protocol
Provides a fast reliable output by using Electro Chemical / Pellister Sensor Technology
Optimized for detection of smallest leak of Toxic and Combustible Gases

View Complete Details

L110 : Light Transmitter

Range from 0 to 10000 lux
0-10 V active output, power supply 24 Vac/Vdc (3-4 wires) or 4-20 mA output, passive loop, power supply from 16 o 30 Vdc (2 wires)
ABS V0 IP65 housing, with or without display
turn system mounting with wall-mount plate

Housing with simplified mounting system

Features :
Material : ABS V0 as per UL94
Protection : IP65
Display : LCD 10 digits. Size : 50 x 17 mm
Height of digits : Values : 10 mm ; Units : 5 mm
Cable gland : For cables 8 mm maximum
Weight : 140 g
Environment : Air and neutral gases

  Output / Power supply : active 0-10 V (power supply 24 Vac/Vdc ± 10%), 3-4 wires
passive loop 4-20 mA (power supply 16/30 Vdc), 2 wires
maximal load : 500 Ohms (4-20 mA)
maximal load : 500 Ohms (4-20 mA)
Consumption : 2 VA (0-10 V) or max. 22 mA (4-20 mA)
Electromagnetical compatibility : EN61326
Electrical connection : Screw terminal block for cables Ø0.05 to 2.5 mm²
PC communication : USB-mini Din cable
Environment : Air and neutral gases



View Complete Details

TH03: Temperature Transmitter

An optional LCD display can be integral to the transmitter or a remote display can be ordered for building balancing or LEED validation.
The humidity and temperature sensors are field replaceable to reduce service cost and inventory.

The humidity and the dew point are measured using a capacitive polymer sensor that completely recovers from 100% saturation

Feature :
LCD display
Non-dispersive Infrared(NDIR)
Analog output RELAY/RS485
Integrated CMOS temperature and humidity sensor.
Compact 3-in-1 sensor : Carbon dioxide & Temperature & Humidity

View Complete Details

H5: Wall Mount RH T Transmitter

The Series H5 Wall Mount Humidity/Temperature/Dew Point Transmitteris the most versatile room transmitter on the market. The stylish housing is well vented to provide air flow across the sensor to improve measurement accuracy. The LCD display indicates the ambient temperature along with the humidity or dew point. The transmitter has internal dip switches to select the temperature engineering units and whether the transmitter outputs humidity or dew point. The humidity and dew point can have either a current or voltage output, while the optional temperature output can be a current, voltage, RTD or thermistor. For models with current or voltage for the temperature output, the temperature range is field selectable.

Features :
An optional LCD display can be integral to the transmitter or a remote display can be ordered for building balancing or LEED validation.
The humidity and temperature sensors are field replaceable to reduce service cost and inventory.
The humidity and the dew point are measured using a capacitive polymer sensor that completely recovers from 100% saturation.
View Complete Details

HUM : Humidity Transmitter

Humidity & Temperature transmitters are designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used for indoor air temperature and humidity monitoring in various indus- trial plant, clean room, lab, machine room, office and commercial building, airport, station, library and stadium.

Special Features :
High performance digital sensors and circuits, ensure accurate measurement and temperature compensation
Good long term stability and reliability
100% field changeable sensors, no re-calibration needed
Fast response
Multiple output signals selectable: 4-20mA, 0-5V or 0-10V
Display in degrees Fahrenheit or Celsius (connection to Modbus)

  Relative Humidity:  
Sensor : capacitance polymer
Range : 0~100% non condensing
Output : 4-20mA, 0-5V or 0-10V, RS 485
Accuracy : 3% RH (25°C, 20~80% RH)
Hysteresis : < ±1% RH
Response time : < 10s (25°C, in slow air)
Drift : < ±0.5% RH / year
     
  Temperature:  
Sensor : 10K internal
Range : -30~70°C(-22~158°F)/transmitter
Output : 4-20mA, 0-5V or 0-10V, RS 485
Accuracy : < ±0.5°C @ 25°C
     
  General:  
Power : 12 to 24V AC or DC, ±10%
Current Output Load : < 500
Display : LCD screen for wall / outdoor mount and duct mount
Display Resolution : 0.1°C, 0.1% RH
  Temperature Limit : -30~70°C, 0~95% RH(Non condensing)
  Plastic Housing : Flammability rating UL 94V0 file E194560
  Protection : IP65, outdoor rated for duct and wall mount models; IP30 for   room mount
View Complete Details

RH4 : Remote Mount Humidity Temperature Transmitter

  •   Model
  • Range : 0 to 100%RH / -40 to 100ºC
  • Display : NIL
  • Versions : Remote Mount

H2, 3 and 4 humidity and temperature transmitters are designed for environment monitoring and controlling in industrial and commercial buildings. These transmitters can be used for:

Humidity and temperature monitoring of supply, exhaust and return air (H2, duct mount)
Humidity and temperature monitoring in critical environment such as outside air (H3, outside mount)
Other applications of immersion humidity and temperature monitoring (H4, separate probe)

Features :
High performance digital sensors and circuits, ensure accurate measurement and temperature compensation
Good long term stability and reliability
100% field changeable sensors, no re-calibration needed
Fast response
Digital technology applied, multiple output optional, over voltage and reverse polarity protection, high reliability and interference capability
Industrial design, SS probe and selectable filter
High protection rate up to IP65

 

                                  Relative Humidity
Sensor : Digital polymer
Range : 0~100%RH
Output : 4~20mA(2 wires), 0~10VDC(3 wires), RS485
Accuracy : 2,3,4.5%RH(25°C,20~80%RH)
Hysteresis : <±1%RH
Response time   <10s(25°C,in slow air)
Drift : <±0.5%RH/year
                                Temperature
Sensor : Solid state band gap, RTD or thermistor
Range : 0~50°C,0~100°C, -40~60, or others (transmitter)
Output : 4~20mA(2 wires) , 0~10VDC(3 wires) , RS485, or
  RTD, thermistor
Accuracy : see model table
Power : Current 7.5~36VDC, Voltage & Other 15~35VAC/DC
Output Load : <600 ohm (current), >2Kohm (voltage)
Temperature Limit : -40~85°C, 0~95%RH (Non condensing)
Storage Temperature : -40~80°C
Housing : Fireproof ABS Enclosure, SS probe, SS mesh filter or
  sintered filter
Protection : IP65


View Complete Details

RH3 : Wall Mount Humidity Temperature Transmitter

  • Output : 4 - 20mA, 0 - 10V, RS485 Modbus
  • Accuracy : ± 2%RH / ±0.3 K
  • Model : RH3
  • Range : 0 to 100%RH / -40 to 100ºC
  • Display : NIL
  • Versions : Wall Mount

H2, 3 and 4 humidity and temperature transmitters are designed for environment monitoring and controlling in industrial and commercial buildings. These transmitters can be used for:

Humidity and temperature monitoring of supply, exhaust and return air (H2, duct mount)
Humidity and temperature monitoring in critical environment such as outside air (H3, outside mount)
Other applications of immersion humidity and temperature monitoring (H4, separate probe)
Features :
High performance digital sensors and circuits, ensure accurate measurement and temperature compensation
Good long term stability and reliability
100% field changeable sensors, no re-calibration needed
Fast response
Digital technology applied, multiple output optional, over voltage and reverse polarity protection, high reliability and interference capability
Industrial design, SS probe and selectable filter
High protection rate up to IP65

                       Relative Humidity
Sensor : Digital polymer
Range : 0~100%RH
Output : 4~20mA(2 wires), 0~10VDC(3 wires), RS485
Accuracy : 2,3,4.5%RH(25°C,20~80%RH)
Hysteresis : <±1%RH
Response time   <10s(25°C,in slow air)
Drift : <±0.5%RH/year
Temperature
Sensor : Solid state band gap, RTD or thermistor
Range : 0~50°C,0~100°C, -40~60, or others (transmitter)
Output : 4~20mA(2 wires) , 0~10VDC(3 wires) , RS485, or
  RTD, thermistor
Accuracy : see model table
Power : Current 7.5~36VDC, Voltage & Other 15~35VAC/DC
Output Load : <600 ohm (current), >2Kohm (voltage)
Temperature Limit : -40~85°C, 0~95%RH (Non condensing)
Storage Temperature : -40~80°C
Housing : Fireproof ABS Enclosure, SS probe, SS mesh filter or
  sintered filter
Protection : IP65


View Complete Details

RH2 : Duct Mount Humidity Temperature Transmitter

  •   Model
  • Range : 0 to 100%RH / -40 to 100ºC
  • Display : NIL
  • Versions : Duct Mount

H2, 3 and 4 humidity and temperature transmitters are designed for environment monitoring and controlling in industrial and commercial buildings. These transmitters can be used for:

Humidity and temperature monitoring of supply, exhaust and return air (H2, duct mount)
Humidity and temperature monitoring in critical environment such as outside air (H3, outside mount)
Other applications of immersion humidity and temperature monitoring (H4, separate probe)

Features :
High performance digital sensors and circuits, ensure accurate measurement and temperature compensation
Good long term stability and reliability
100% field changeable sensors, no re-calibration needed
Fast response
Digital technology applied, multiple output optional, over voltage and reverse polarity protection, high reliability and interference capability
Industrial design, SS probe and selectable filter
High protection rate up to IP65

Relative Humidity
Sensor : Digital polymer
Range : 0~100%RH
Output : 4~20mA(2 wires), 0~10VDC(3 wires), RS485
Accuracy : 2,3,4.5%RH(25°C,20~80%RH)
Hysteresis : <±1%RH
Response time   <10s(25°C,in slow air)
Drift : <±0.5%RH/year
Temperature
Sensor : Solid state band gap, RTD or thermistor
Range : 0~50°C,0~100°C, -40~60, or others (transmitter)
Output : 4~20mA(2 wires) , 0~10VDC(3 wires) , RS485, or
  RTD, thermistor
Accuracy : see model table
Power : Current 7.5~36VDC, Voltage & Other 15~35VAC/DC
Output Load : <600 ohm (current), >2Kohm (voltage)
Temperature Limit : -40~85°C, 0~95%RH (Non condensing)
Storage Temperature : -40~80°C
Housing : Fireproof ABS Enclosure, SS probe, SS mesh filter or
  sintered filter
Protection : IP65


View Complete Details

RH1 : Space Mount Humidity Temperature Transmitter

  • Output 4 - 20mA, 0 - 10V, RS485 Modbus
  • Accuracy  ± 2%RH / ±0.3 K
  • Model  RH1
  • Range  0 to 100%RH / -40 to 100ºC
  • Display  Optional
  • Versions  Space Mount

H1 wall mount temperature and humidity transmitters are designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used for indoor air temperature and humidity monitoring in various industrial plant, clean room, lab, machine room, office and commercial building, airport, station, library and stadium, etc.

Special Features :
High performance digital sensors and circuits, ensure accurate measurement
temperature compensation
Good long term stability and reliability
100% interchangeable sensors, no re-calibration needed
Fast response
Light and state of art house, easy installation and wiring
Digital technology applied, multiple output optional, over voltage and reverse polarityprotection, high reliability and interference capability


 
                    Relative Humidity
Sensor : Digital polymer
Range : 0~100%RH
Output : 4~20mA(2 wires), 0~10VDC(3 wires), RS485
Accuracy : 2,3,4.5%RH(25°C,20~80%RH)
Hysteresis : <±1%RH
Response time   <10s(25°C,in slow air)
Drift : <±0.5%RH/year
Temperature
Sensor : Solid state band gap, RTD or thermistor
Range : 0~50°C
Output : 4~20mA(2 wires), 0~10VDC(3 wires), RS485, or
  RTD, thermistor
Accuracy : see model table
Power : Current 7.5~36VDC Voltage & Other 15~35VAC/DC
Output Load : <600 ohm (current), >2Kohm (voltage)
Display : Large LCD display
Display Resolution : 0.1°C, 0.1%RH
Temperature Limit : 0~70°C, 0~95%RH (Non condensing)
Storage Temperature : -20~80°C
Housing : Fireproof ABS
Protection : IP30


View Complete Details

OM375 : Compact Dew Point Temperature Transmitter For OEM Applications

The exact monitoring of dew point temperature in compressed air systems, dryers for plastic and other industrial processes is becoming increasingly more important.The 0M375 is designed for measurement of low dew points in OEM applications down to -60C.The core of the transmitter is the monolithic measurement cell type HMC01 developed by Omicron Sensing in thin-film technology.An autocalibration procedure which is integrated in the device and years of experience in low humidity adjust-ment make an accuracy of

Dew Point (Td)    
Dew Point Sensor : HMC01
Measuring Range : 25°C to + 65°C
Accuracy : Traceable to intern. standards, administrated
by NIST, PTB, BEV...
     
Response Time t90 : 80 sec. -20°C Td —> -40°C Td (-4°F Td —> -40°F Td)
10 sec -40°C Td —> -20°C Td (-40°F Td —> -4°F Td)
     
Volume concentration    
Measuring range : 20...200 000ppm
Accuracy at 20°C (68°F)
and 1013mbar
: 5ppm + 20% of reading
     
Outputs    
Selectable and scalable : 0 - 10V -1mA< I,< 1mA
analogue output for Td,
Tf, Wv
: 4 - 20mA R < 500 Ohm
     
General    
Supply Voltage : 21...28V DC
Current Consumption at
24V DC
: voltage output: typ. 40mA / during autocalibration: 100mA
  : voltage output: typ. 80mA / during autocalibration: 100mA
Pressure Range : 0...20bar (0...290psi)
Housing / protection class : Al Si Cu 3 / IP65
Electrical connection : M12 connector
Sensor protection : stainless steel sintered filter
Working temperature range : probe: -40...70°C (-40...158°F)
    electronic. -40...60°C (-40 140°F)
Storage temperature range : -40...60°C (-40...140°F)
Electromagnetic
compatibility according to
: EN 61326-1 EN61326-2-3 ICES-003 ClassB
Industrial Environment FCC Part15 ClassB







View Complete Details

OM371 : Compact Dew Point Temperature Transmitter / Switch

The exact monitoring of dew point temperature in compressed air systems, dryers for plastic and other industrial processes is becoming increasingly more important. 0M371 series with a measuring range -60.60C Td (-112.140F Td) is the ideal solution for such applications. The core of the transmitter is the monolithic measurement cell type HMC01, developed by Omicron Sensing in thin film technology.An autocalibration procedure which is integrated in the device and years of experience in low humidity adjustment make an accuracy of

Measuring Quantities
Dew Point (Td)    
Dew Point Sensor : HMC01
Measuring Range : 25°C to + 65°C
Accuracy : Traceable to intern. standards, administrated
by NIST, PTB, BEV...
     
Response Time t90 : 80 sec. -20°C Td —> -40°C Td (-4°F Td —> -40°F Td)
10 sec -40°C Td —> -20°C Td (-40°F Td —> -4°F Td)
     
Volume concentration    
Measuring range : 20...200 000ppm
Accuracy at 20°C (68°F)
and 1013mbar
: 5ppm + 20% of reading
     
Outputs    
Selectable and scalable : 0 - 10V -1mA< I,< 1mA
analogue output for Td,
Tf, Wv
: 4 - 20mA R < 500 Ohm
     
General    
Supply Voltage : 21...28V DC
Current Consumption at
24V DC
: voltage output: typ. 40mA / during autocalibration: 100mA
  : voltage output: typ. 80mA / during autocalibration: 100mA
Pressure Range : 0...20bar (0...290psi)
Housing / protection class : Al Si Cu 3 / IP65
Electrical connection : M12 connector
Sensor protection : stainless steel sintered filter
Working temperature range : probe: -40...70°C (-40...158°F)
    electronic. -40...60°C (-40 140°F)
Storage temperature range : -40...60°C (-40...140°F)
Electromagnetic
compatibility according to
: EN 61326-1 EN61326-2-3 ICES-003 ClassB
Industrial Environment FCC Part15 ClassB







View Complete Details

OS137 : Infrared Temperature Transmitter

OS137 using non-contact temperature measurement device.Provide 4-20mA current output it can be easily installed in a variety of applications, especially suitable for long distances, install more noise industrial environments.The probe uses a stainless steel shell, in the industrial

Spectral Range : 1.6um/1um
Accuracy @ 25ºC : ±0.5% or 1°C
Repeatability @ 25ºC : ±0.5% or 5°C
ResponseTime : 10ms(95%)
Emissivity : 0.10-1.00
Analog Output : 4-20mA with 750 ohm Max. load
Power : 24VDC -5%
Sight : Laser Sighting(Level 2 laser, the maximum
  output power1mW,650nm
Operating Ambient
Temperature
: OperatingAmbientTemperature
StorageTemperature : 20 to 70ºC
Protection class : IP65
Weight (sensor only) : 0.9kg


View Complete Details

RT5100 : Insertion Type Temperature Transmitter

  • Type : Temperature Transmitter
  • Accuracy : ±0.5% of Reading
  • Output : 4 - 20mA
  • Model : RT5100
  • Temperature Range : -200 to 1800°C
  • Power Supply : 24V DC

RT5100 Insertion Temperature Transmitters with Compact Design are used for various applications in Aviation Industry, Pharmceuticals, Refrigeration and HVAC Controls, Process Control, Motor Fuel Control, Water Pressure Monitoring and High end industrial machinery.

Special Features :
Low Cost OEM
Mineral Insulated
Crevice Free Stainless Steel Construction
Available in Exotic Metals
Compact Version
Surge Protection, Over Voltage Protection to 16V DC

No. of Element : Simplex
Element Type : PT-100
Temperature Range : -100 C to 600 C
Ambient Temperature : -20 C to 85 C
Accuracy : ±0.5% of F.S
Max Pressure : 16 Bar
Input Voltage : 12 - 36 VDC
Output : 4-20 mA
Sheath Diameter : 3mm - 12 mm
Display : 4 Digit 7 Segment LED
View Complete Details

T648D: DIN Rail Universal Temperature Transmitter (HART)

  • Accuracy : ±0.1% of F.S
  • Output : 4 - 20mA
  • Model : T648D
  • Temperature Range : -200 to 850°C
  • Power Supply : 12 - 36V DC

Food & beverage, pharmaceutical, chemical & petrochemical industries, conventional & nuclear plants, pumps, presses, turbines, hydro-cleaning machines, diesel engines & refrigerating plants.

Special Features :
Programmable Universal Input (RTD / Thermocouples / mV / V)
Linear Signal Output
Current Loop Powered
PC Based Configuration via USB Cable
High Accuracy and Repeatability

Input : RTD: Pt-50, Pt100 (2W / 3W / 4W), Pt-500, Pt-1000
  : Thermocouples: Type B, E, J, K, N, R, S, T
  : mV: -120 ~ 120 mV, -1000 ~ 1000 mV
Output : 4 - 20 mA, two wire
Accuracy : ±0.1% of the calibrated span
Operating Temp. : -40°C to 85°C
Storage Temp. : -40°C to 120°C
Calibration   Configuration with PC via USB Cable
Isolation : Input / Output Isolation Tested to 500 VAC rms (707 VDC) at    50 / 60 Hz
Loop Supply : 24V DC nominal (12 to 36)V DC
Loop Resistance : 600 Ohm @ 24V DC
Burn Out : Upscale for RTD PT-100 / Thermocouples
Protection : IP55
Update Rate : 0.5 sec
Turn On Time : 5 sec after power is applied
Minimum Span : 10°C / 18°F
View Complete Details

T248D: DIN Rail Mounted Universal Temperature Transmitter

  • Accuracy : ±0.1% of F.S
  • Output : 4 - 20mA
  • Model : T248D
  • Temperature Range : -200 to 850°C
  • Power Supply : 12 - 36V DC

Food & beverage, pharmaceutical, chemical & petrochemical industries, conventional & nuclear plants, pumps, presses, turbines, hydro-cleaning machines, diesel engines & refrigerating plants.

Special Features :
Programmable Universal Input (RTD / Thermocouples / mV / V)
Linear Signal Output
Current Loop Powered
PC Based Configuration via USB Cable
High Accuracy and Repeatability

Input : RTD: Pt-50, Pt100 (2W / 3W / 4W), Pt-500, Pt-1000
  : Thermocouples: Type B, E, J, K, N, R, S, T
  : mV: -120 ~ 120 mV, -1000 ~ 1000 mV
Output : 4 - 20 mA, two wire
Accuracy : ±0.1% of the calibrated span
Operating Temp. : -40°C to 85°C
Storage Temp. : -40°C to 120°C
Calibration   Configuration with PC via USB Cable
Isolation : Input / Output Isolation Tested to 500 VAC rms (707 VDC) at    50 / 60 Hz
Loop Supply : 24V DC nominal (12 to 36)V DC
Loop Resistance : 600 Ohm @ 24V DC
Burn Out : Upscale for RTD PT-100 / Thermocouples
Protection : IP55
Update Rate : 0.5 sec
Turn On Time : 5 sec after power is applied
Minimum Span : 10°C / 18°F
View Complete Details

T148D: DIN Rail Mounted Temperature Transmitter (RTD)

  • Accuracy : ±0.1% of F.S
  • Output : 4 - 20mA
  • Model : T148D
  • Temperature Range : -200 to 850°C
  • Power Supply : 12 - 36V DC

Food & beverage, pharmaceutical, chemical & petrochemical industries, conventional & nuclear plants, pumps, presses, turbines, hydro-cleaning machines, diesel engines & refrigerating plants.

Special Features :
Programmable Input (Pt-100 3W)
Linear Signal Output
Current Loop Powered
PC Based Configuration via USB Cable
High Accuracy and Repeatability

  Input : RTD: Pt100 2W / 3W / 4W
Output : 4 - 20 mA, two wire
Accuracy : ±0.1% of the calibrated span
Operating Temp. : -40°C to 85°C
Storage Temp. : -40°C to 120°C
Calibration   Configuration with PC via USB Cable
Isolation : Input / Output Isolation Tested to 500 VAC rms (707 VDC) at    50 / 60 Hz
Loop Supply : 24V DC nominal (12 to 36)V DC
Loop Resistance : 600 Ohm @ 24V DC
Burn Out : Upscale for RTD PT-100
Protection : IP55
Update Rate : 0.5 sec
Turn On Time : 5 sec after power is applied
Minimum Span : 10°C / 18°F
View Complete Details

T648R: Universal Head Mounted SMART Temperature Transmitter

  • Accuracy : ±0.1% of F.S
  • Type : Universal Head Mounted SMART Temperature Transmitter
  • Model : T648R
  • Input Sensors : RTD, Thermocouples, mV, Ω
  • Temperature Range : -270 to 1820°C
  • Output : 4 - 20mA, 2 wire, superimposed HART
  • Power Supply : 12 - 36V DC

Food & beverage, pharmaceutical, chemical & petrochemical industries, conventional & nuclear plants, pumps, presses, turbines, hydro-cleaning machines, diesel engines & refrigerating plants.

Special Features :
Programmable Input (RTD / Thermocouples / mV, )
Linear Signal Output
Current Loop Powered
Configuration with a PC via USB cable
High Accuracy and Repeatability

Input : RTD: Pt-50, Pt-100, Pt-500, Pt-1000
  : Thermocouples: Type B, E, J, K, N, R, S, T
  : Resistance: 0 - 500 Ω / 0 - 4500 Ω
  : mV: -120 ~ 120mV, -1000 ~ 1000 mV
Output : 4 - 20 mA, two wire with HART superimposed
Accuracy : ±0.1% of the calibrated span
Operating Temp. : -40°C to 85°C
Storage Temp. : -40°C to 120°C
Calibration   Configuration with PC via USB Cable
Ingress Protection : IP68
Loop Supply : 24V DC nominal (12 to 30)V DC
Loop Resistance : 600 Ohm @ 24V DC
Burn Out : Upscale for RTD / Thermocouples
View Complete Details

T148R: RTD Head Mounted Temperature Transmitter

  • Accuracy : ±0.1% of F.S
  • Type : Head Mounted Temperature Transmitter for RTD
  • Model : T148R
  • Temperature Range : -200 to 850°C
  • Output : 4 - 20mA
  • Power Supply : 12 - 36V DC

Food & beverage, pharmaceutical, chemical & petrochemical industries, conventional & nuclear plants, pumps, presses, turbines, hydro-cleaning machines, diesel engines & refrigerating plants.

Special Features :
Programmable Input (Pt-100)
Linear Signal Output
Current Loop Powered
Configuration with a PC via USB cable
High Accuracy and Repeatability

  Input : RTD: Pt-100
Output : 4 - 20 mA, two wire
Accuracy : ±0.1% of the calibrated span
Operating Temp. : -40°C to 85°C
Storage Temp. : -40°C to 120°C
Calibration   Configuration with PC via USB Cable
Ingress Protection : IP68
Loop Supply : 24V DC nominal (12 to 30)V DC
Loop Resistance : 600 Ohm @ 24V DC
Burn Out : Upscale for RTD

View Complete Details

MA1300 : Melt Pressure Transmitter With Temperature Output And Auto Zero Adjustment

  • Type : Melt Pressure
  • Model : MA1300
  • Range : 0 to 1500 bar
  • output : 4 - 20mA, 0 - 10V
  • Accuracy : ± 0.5% of F.S
  • Temperature Limits : -40 to 350ºC
  • Over Pressure : 2X

MA1300 Series Economic melt Pressure Transducer designed for economic applications. The model MA1200 and MA1300 are introduced with automatic zero adjustment. This series can be used together with the PVI Series Intelligent Digital Pressure Instrument of Omicron or other brand instrumentation. Zero & full span can be adjustable externally if required, with amplify signal can be connected with PLC. With the advantage of high precision and reliable pressure measuring and good quality, internal 80% calibration and etc.

Applications :

It can be widely used in various plastic extrusion line for pressure measuring and control, such as chemical fibre manufacturing equipment, plastic rubber machine, polyester equipment and petrochemical industries.

Pressure Range : 0-3.5MPa--0-150MPa
  (0-500psi---0-30000psi)
Over Pressure : 1.5 X FSO
Combined Error : ± 1.0% FSO, ± 1.5% FSO
  (Including Linearity, Repeatability & Hysteresis)
Output : 3.33 mV/V, 2mV/V; 4-20mA, 0-10V, 0-5V
Input Voltage : 10VDC; 24VDC
Repeatability   +/- 0.2% FSO
Bridge Resistance : Input: 345 Ohms minimum
  Output: 350 Ohms +/- 10%
Internal Shunt Calibration (R-Cal) : 80% FSO +/- 1%
Insulation Resistance : 200 megohms @ 100 Vdc
Max Diaphragm Temperature : 400oC
Mounting Torque : 500 inch/lbs, maximum
Standard Wetted Parts : Diaphragm coated 15-5 PH SST
Thermocouple type : J, K, E, PT100
Electrical connector : 5PIN connector
Process connector : 1/2" - 20 UNF, M18 x 1.5



View Complete Details

MT1300 : Melt Pressure Transmitter With Temperature Output

  • Type : Melt Pressure
  •   Model
  • output : 4 - 20mA, 0 - 10V
  • Temperature Limits : -40 to 350ºC

MT1300 Series Economic melt Pressure Transducer designed for economic applications. The model M1300 and MT1300 is with thermocouple, which can measure the pressure and temperature at one point. This series can be used together with the PVI Series Intelligent Digital Pressure Instrument of Omicron or other brand instrumentation. Zero & full span can be adjustable, with amplify signal can be connected with PLC. With the advantage of high precision and reliable pressure measuring and good quality, internal 80% calibration and etc.

Applications :
It can be widely used in various plastic extrusion line for pressure measuring and control, such as chemical fibre manufacturing equipment, plastic rubber machine, polyester equipment and petrochemical industries.

Pressure Range : 0-3.5MPa--0-150MPa
  (0-500psi---0-30000psi)
Over Pressure : 1.5 X FSO
Combined Error : ± 1.0% FSO, ± 1.5% FSO
  (Including Linearity, Repeatability & Hysteresis)
Output : 3.33 mV/V, 2mV/V; 4-20mA, 0-10V, 0-5V
Input Voltage : 10VDC; 24VDC
Repeatability   +/- 0.2% FSO
Bridge Resistance : Input: 345 Ohms minimum
  Output: 350 Ohms +/- 10%
Internal Shunt Calibration (R-Cal) : 80% FSO +/- 1%
Insulation Resistance : 200 megohms @ 100 Vdc
Max Diaphragm Temperature : 400oC
Mounting Torque : 500 inch/lbs, maximum
Standard Wetted Parts : Diaphragm coated 15-5 PH SST
Thermocouple type : J, K, E, PT100
Electrical connector : 5PIN connector
Process connector : 1/2" - 20 UNF, M18 x 1.5



View Complete Details

M1300 : Melt Pressure Transmitter

  • Type : Melt Pressure
  • Model : M1300
  • Range : 0 to 2000 bar
  • output : 4 - 20mA, 0 - 10V
  • Accuracy : ± 0.5% of F.S
  • Temperature Limits : -40 to 350ºC
  • Over Pressure : 2X

M1300 Series Economic melt Pressure Transducer designed for economic applications. The model M1300 and MT1300 is with thermocouple, which can measure the pressure and temperature at one point. This series can be used together with the PVI Series Intelligent Digital Pressure Instrument of Omicron or other brand instrumentation. Zero & full span can be adjustable, with amplify signal can be connected with PLC. With the advantage of high precision and reliable pressure measuring and good quality, internal 80% calibration and etc.

Applications :

It can be widely used in various plastic extrusion line for pressure measuring and control, such as chemical fibre manufacturing equipment, plastic rubber machine, polyester equipment and petrochemical industries.

  Pressure Range : 0-3.5MPa--0-150MPa
  (0-500psi---0-30000psi)
Over Pressure : 1.5 X FSO
Combined Error : ± 1.0% FSO, ± 1.5% FSO
  (Including Linearity, Repeatability & Hysteresis)
Output : 3.33 mV/V, 2mV/V; 4-20mA, 0-10V, 0-5V
Input Voltage : 10VDC; 24VDC
Repeatability   +/- 0.2% FSO
Bridge Resistance : Input: 345 Ohms minimum
  Output: 350 Ohms +/- 10%
Internal Shunt Calibration (R-Cal) : 80% FSO +/- 1%
Insulation Resistance : 200 megohms @ 100 Vdc
Max Diaphragm Temperature : 400oC
Mounting Torque : 500 inch/lbs, maximum
Standard Wetted Parts : Diaphragm coated 15-5 PH SST
Electrical connector : 5PIN connector
Process connector : 1/2" - 20 UNF, M18 x 1.5



View Complete Details

MA1200 : Melt Pressure Transmitter With Temperature Output And Auto Zero Adjustment

  • Type : Melt Pressure
  •   Model
  • output : 4 - 20mA, 0 - 10V
  • Temperature Limits : -40 to 350ºC

MA1200 Series Economic melt Pressure Transducer designed for economic applications. The model MA1200 and MA1300 are introduced with automatic zero adjustment. This series can be used together with the PVI Series Intelligent Digital Pressure Instrument of Omicron or other brand instrumentation. Zero & full span can be adjustable externally if required, with amplify signal can be connected with PLC. With the advantage of high precision and reliable pressure measuring and good quality, internal 80% calibration and etc.

Applications :
It can be widely used in various plastic extrusion line for pressure measuring and control, such as chemical fibre manufacturing equipment, plastic rubber machine, polyester equipment and petrochemical industries.

  Pressure Range : 0-3.5MPa--0-150MPa
  (0-500psi---0-30000psi)
Over Pressure : 1.5 X FSO
Combined Error : ± 1.0% FSO, ± 1.5% FSO
  (Including Linearity, Repeatability & Hysteresis)
Output : 3.33 mV/V, 2mV/V; 4-20mA, 0-10V, 0-5V
Input Voltage : 10VDC; 24VDC
Repeatability   +/- 0.2% FSO
Bridge Resistance : Input: 345 Ohms minimum
  Output: 350 Ohms +/- 10%
Internal Shunt Calibration (R-Cal) : 80% FSO +/- 1%
Insulation Resistance : 200 megohms @ 100 Vdc
Max Diaphragm Temperature : 400oC
Mounting Torque : 500 inch/lbs, maximum
Standard Wetted Parts : Diaphragm coated 15-5 PH SST
Thermocouple type : J, K, E, PT100
Electrical connector : 5PIN connector
Process connector : 1/2" - 20 UNF, M18 x 1.5



View Complete Details

MT1200 : Melt Pressure Transmitter With Temperature Output

  • Type : Melt Pressure
  • Model : MT1200
  • Range : 0 to 2000 bar
  • output : 4 - 20mA, 0 - 10V
  • Accuracy : ± 0.5% of F.S
  • Temperature Limits : -40 to 350ºC
  • Over Pressure : 2X

MT1200 Series Economic melt Pressure Transducer designed for economic applications. The model M1200 and MT1200 is with thermocouple, which can measure the pressure and temperature at one point. This series can be used together with the PVI Series Intelligent Digital Pressure Instrument of Omicron or other brand instrumentation. Zero & full span can be adjustable, with amplify signal can be connected with PLC. With the advantage of high precision and reliable pressure measuring and good quality, internal 80% calibration and etc.

Applications :
It can be widely used in various plastic extrusion line for pressure measuring and control, such as chemical fibre manufacturing equipment, plastic rubber machine, polyester equipment and petrochemical industries.

  Pressure Range : 0-3.5MPa--0-150MPa
  (0-500psi---0-30000psi)
Over Pressure : 1.5 X FSO
Combined Error : ± 1.0% FSO, ± 1.5% FSO
  (Including Linearity, Repeatability & Hysteresis)
Output : 3.33 mV/V, 2mV/V; 4-20mA, 0-10V, 0-5V
Input Voltage : 10VDC; 24VDC
Repeatability   +/- 0.2% FSO
Bridge Resistance : Input: 345 Ohms minimum
  Output: 350 Ohms +/- 10%
Internal Shunt Calibration (R-Cal) : 80% FSO +/- 1%
Insulation Resistance : 200 megohms @ 100 Vdc
Max Diaphragm Temperature : 400oC
Mounting Torque : 500 inch/lbs, maximum
Standard Wetted Parts : Diaphragm coated 15-5 PH SST
Thermocouple type : J, K, E, PT100
Electrical connector : 5PIN connector
Process connector : 1/2" - 20 UNF, M18 x 1.5



View Complete Details

M1200 : Melt Pressure Transmitter

  • Type : Melt Pressure
  • Model : M1200
  • Range : 0 to 2000 bar
  • output : 4 - 20mA, 0 - 10V
  • Accuracy : ± 0.5% of F.S
  • Temperature Limits : -40 to 350ºC
  • Over Pressure : 2X

M1200 Series Economic melt Pressure Transducer designed for economic applications. The model M1200 and MT1200 is with thermocouple, which can measure the pressure and temperature at one point. This series can be used together with the PVI Series Intelligent Digital Pressure Instrument of Omicron or other brand instrumentation. Zero & full span can be adjustable, with amplify signal can be connected with PLC. With the advantage of high precision and reliable pressure measuring and good quality, internal 80% calibration and etc.

Applications :
It can be widely used in various plastic extrusion line for pressure measuring and control, such as chemical fibre manufacturing equipment, plastic rubber machine, polyester equipment and petrochemical industries.

Pressure Range : 0-3.5MPa--0-150MPa
  (0-500psi---0-30000psi)
Over Pressure : 1.5 X FSO
Combined Error : ± 1.0% FSO, ± 1.5% FSO
  (Including Linearity, Repeatability & Hysteresis)
Output : 3.33 mV/V, 2mV/V; 4-20mA, 0-10V, 0-5V
Input Voltage : 10VDC; 24VDC
Repeatability   +/- 0.2% FSO
Bridge Resistance : Input: 345 Ohms minimum
  Output: 350 Ohms +/- 10%
Internal Shunt Calibration (R-Cal) : 80% FSO +/- 1%
Insulation Resistance : 200 megohms @ 100 Vdc
Max Diaphragm Temperature : 400oC
Mounting Torque : 500 inch/lbs, maximum
Standard Wetted Parts : Diaphragm coated 15-5 PH SST
Electrical connector : 5PIN connector
Process connector : 1/2" - 20 UNF, M18 x 1.5



View Complete Details

DP662: Differential Pressure Transmitter

  • Output : 0-10 V / 4 - 20 mA
  • Accuracy : ±1% of F.S
  • Model : DP662
  • Range : -500 to 500 mmwc
  • Media : Air / Gases
  • Display : Optional

For acquiring the differential pressure of air or nonaggressive gases in ventilation, air conditioning and heating plant.The differential pressure sensors are used to:

Acquire over- or underpressure in air ducts in relation to ambient pressure
Monitor filters and to control fans
Acquire pressure differentials between different rooms
Delivery with tubing connection set

Features :
Pressure-linear characteristic with selectable pressure measuring range
Operating voltage AC 24 V or DC 13.5.33 V
Output signal DC 0.10 V
Delivery with tubing connection set

View Complete Details

S323: IP65 Differential Pressure Transmitter

  • Output : 0-10 V / 4-20 mA
  • Accuracy : ±0.25% of F.S
  • Model : S323
  • Range : -500 to 500 mmwc
  • Media : Air / Gases
  • Display : None

Maximum Pressure : Ranges ≤ 5 PSI (35 kPa) = 15 PSI (100 kPa) Max
Storage : Ranges > 5 PSI (35 kPa) = 30 PSI (200 kPa) Max
Media compatibility : Air and compatible non combustible,
  non corrosive gasses
Accuracy : Ranges ≤ 4” w.c. (1 kPa) 1.0% Ranges ≥
  5” w.c. (1.25 kPa) 0.25%
Temperature Ranges
Compensated : 15° to 120°F (-10° to 50°C)
Operating : -10° to 155°F (-25° to 70°C)
Thermal Effect : +/- 0.028% FS/°F (+/- 0.050%/° C)
Stability : +/- 0.25% FS/year
Output Signal : 4-20 mA, 2 wire or 0-10V
Loop Resistance : 250 Ω @ 24 VDC
Power Supply : 12-30 VDC
Enclosure Rating : IP 65
Electrical Connections : screw terminals
Electrical Entry : PG7 cable gland
Process Connection : Barbed fittings for 3/16” flexible tubing
Agency Approvals : CE


View Complete Details

S322: Differential Pressure Transmitter

  • Output : 4 - 20 mA
  • Accuracy : ±0.25% of F.S
  • Model : S322
  • Range : -500 to 500 mmwc
  • Media : Air / Gases
  • Display : None

Filter Status, Duct Static Pressure, Fan and Blower Pressure, Paint Booths, Dust Collectors, Glove Box Pressure, Bubbler Systems, Cabinet Purging.

Special Features :
Compact Design
0.25% Accuracy
Compact Design
LED Power Indication
2-Wire Design
4-20 mA output

Maximum Pressure : Ranges ≤ 5 PSI –Max 15 PSI
  Ranges > 5 PSI –Max 30 PSI
Media compatibility : Air and compatible non combustible,
  non corrosive gasses
Accuracy : Ranges . 4 <= " w.c. 1.0%
  Ranges . 5 =>" w.c. 0.25%
Temperature Ranges : Compensated: 15° to 120°F (-10° to 50°C)
  Operating: -10° to 155°F (-25° to 70°C)
Thermal Effect : +/- 0.028% FS/°F
Stability : +/- 0.25% FS/year
Output Signal : 4-20 mA, 2-wire
Loop Resistance : 250 OHM @ 24 VDC
Power Supply : 12-30 VDC
Housing Material : ABS Plastic
Electrical Connections : screw terminals
Process Connection : Push on connection for 1/8” I.D. tubing




View Complete Details

APR2000: Differential Pressure Transmitter

  • Output : 4 - 20mA, HART
  • Accuracy : ±0.075% of F.S
  • Model : APR2000
  • Range : 0 to 400 bar
  • Media : Wet / Wet
  • Display : LCD

Omicrons APR2000 SMART DP differential pressure transmitter provides a kind of reliable measuring way. It is used for measuring differential pressure (or pressure), level, density of liquid, gas or steam and convert the value of above into current signal output or digital protocol output. The pressures are directly applied to the isolating diaphragm that provide isolation and resistance against process fluid corrosion. Being microprocessor based, the electronic circuit is extremely versatile and accurate. Combined with the sensor precision, it provides the high accuracy and range ability. Transmitter performance is improved by continuous monitoring of the sensor temperature and corresponding corrections. A local display permits easy reading and writing of data.

Overview :
The APR 2000s design is offered for Differential Pressure (DP), Gage Pressure (GP) and Absolute Pressure (AP) measurements. The APR 2000 utilizes capacitance sensor technology for DP measurements. The major components of the APR 2000 is the sensor module and the electronics housing. The sensor module contains the oil filled sensor system (isolating diaphragms, oil fill system, and sensor) and the sensor electronics. The sensor electronics are installed within the sensor module and include a temperature sensor (RTD), a memory module, and the capacitance to digital signal converter (C/D converter). The electrical signals from the sensor module are transmitted to the output electronics in the electronics housing. The electronics housing contains the output electronics board (microprocessor, memory module, digital to analog signal converter or D/A converter), the local zero and span buttons, and the terminal block. With APR 2000 design the pressure is applied to the isolating diaphragms, the oil deflects the center diaphragm, which then changes the capacitance. This capacitance signal is then changed to a digital signal in the C/D converter. The microprocessor then takes the signals from the RTD and C/D converter calculates the correct output of the transmitter. This signal is then sent to the D/A converter, which converts the signal back to an analog signal and superimposes the HART signal on the 4-20 mA output.
View Complete Details

D9800: Wet Differential Pressure Transmitter

  • Output : 4 - 20 mA
  • Accuracy : ±0.25% of F.S
  • Model : D9800
  • Range : 0 to 250 bar
  • Media : Wet / Wet
  • Display : Optional

Compact, Rugged Design
High Strength Stainless Steel Construction
No Fluid Fill Cavities or Internal O-rings
Differential Ranges up to 1, 000 PSI [70 Bar]
CE EN61326
Wide Operating Temperature Range
Excellent Price to Performance Ratio

Applications :

Industrial OEM Equipment
Gas Compressors
HVAC
Test Stands
Train Braking Circuits
Water Management
Filtration
Off Road / Marine
Refrigeration
Hydrogen*
Data Loggers

Temperature
Operating : -40 to 125°C (-40 to 185°F)
Storage : -40 to 125°C (-40 to 212°F)
Thermal Limits
Compensated Range : -20 to 65°C
TC Zero : <±1.5% of FS
TC Span : <± 1.5% of FS
Other
Shock : 100G, 11 msec, 1/2 sine
Vibration : 10G peak, 20 to 2000 Hz.
EMI/RFI Protection : 100V/m, 150kHz to 1GHz
Rating : IP-66
Installation direction : Vertical

View Complete Details

DP: Differential Pressure Transmitter

  • Output : 0-10 V / 4 - 20 mA
  • Accuracy : ±1% of F.S
  • Model : DP
  • Range : -1000 to 2000 mmwc
  • Media : Air / Gases
  • Display : Optional

DP differential pressure transmitter applies new CDM technology, can precisely monitor very low range differential pressure with multiple functions. It can compensate temperature effect, is not sensitive to medium and does not have any pressure drift. So is very reliable. The pressure vibration can be filtered by the damping function. The output is steady under very low range pressure and the sensor is not sensitive to dust and moisture. It could even be installed in the outside air environment between -2070C. It is applicable to: clean room, isolated room, ventilation system, energy management system, leak testing, air velocity measurement, medical care and test instrument, furnace pressure test, etc.

Special Features :
Minimum DP range to 25Pa and accuracy is 1%
Range select could be easily set by button in field, do not need extra pump equipment
Multiple applications, positive, negative or differential pressure
Selectable double line four bit LCD Display
High protection housing IP65

Medium : Air and non-combustible gas
Accuracy : 1%
Range : min. 0~25Pa, max. 0~3KPa
Temperature range : -10~50°C
Temperature drift : 0.05% (zero and full range total)
Pressure limit : 1 psi (continuous), 10 psi (exploded)
Power supply : 10~35VDC(2 wires);
  10~36VDC or isolated 15~26VAC (3 wires)
Output signal : 4~20mA(2 wires); 0~10(3 wires)
Response time : field adjustable 0.5~15s
Zero and Span adjust : digital button
Output load : <1250 ohm (current); >1000 ohm (voltage)
Electrical consumption : <40mA
Display (optional) : LCD
Electrical connection : 1/2" NPS terminal
Pressure connection : 3/16" (5 mm) ID pipe, Max. OD 9mm
Protection rate : IP65
Installation direction : vertical

View Complete Details

M11: Differential Pressure Transmitter

  • Output : 4 - 20 mA
  • Accuracy : ±0.25% of F.S
  • Model : M11
  • Range : -500 to 500 mmwc
  • Media : Air / Gases
  • Display : None

LCD backlit digital display

Auto zero calibration when power on
The imported pressure core
M11 Range:-1, 000Pa1, 000Pa (Minimum range from 0100Pa)
M11 Range : -10, 000Pa10, 000Pa (Minimum range from 01, 000Pa)
Adjustable differential pressure range
Housing with simplified mounting systems
This transmitter is apply to low differential pressure display and signal collection in HVAC, industrial equipment, intelligent building, test bench and other fields.

Range M11 -1,000 ~ +1,000 Pa ( Minimum range from
0 ~ +100 Pa )
  M11 -10,000 ~ +10,000Pa ( Minimum range from
0 ~ +1,000Pa )
Precision ±1.0% FS
Pressure Unit M11 / Pa, mmH2O, mbar, inWG,
  M11 mmHG, daPa, KPa, hPa
Tolerated M11 15,000Pa
Overpressure M11 150,000Pa
Output signal 4 ~ 20 mA and 0 ~ 10 Vdc ( 2 signals available )
  16 ~ 30 Vdc/Vac ( 2 wires )
Power Supply 24Vdc adaptor power supply
  220Vac
Power Consumption 1.5W


View Complete Details

Head Mounted Transmitter

  • Accuracy ±0.1% of F.S
  • Input Sensors RTD, Thermocouples, mV, Ω
  • Temperature Range -270 to 1820°C
Programmable Input (RTD Thermocouples mV, )Linear Signal OutputCurrent Loop PoweredConfiguration with a PC via USB cableHigh Accuracy and Repeatability
View Complete Details

Pressure Transmitters

A prominent manufacturer, supplier of huge range of Pressure Transmitters.
View Complete Details

Differential Pressure Transmitter

A prominent manufacturer, supplier of huge range of Differential Pressure Transmitter.
View Complete Details

Melt Pressure Transmitters

We are leading manufacturer and supplier of huge range of melt pressure transmitters.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us