Our Products
We offer a complete product range of Water Level Sensors, CD4: Chlorine Dioxide Sensors, CL5: Free Chlorine Sensors, DOT-6400 : Submersible Galvanic Dissolved Oxygen Sensors and CS : Current Sensors
The CD4 series (chlorine dioxide sensors) feature amperometric measurement technology.Designed for disinfection applications in water treatment, for use with chlorine dioxide, chlorine generators, pools, etc., these sensors are available in several ranges for detecting ppm level of chlorine dioxide or free chlorine to better help our customers. Choose the CD402 for 0-2ppm and CD410 for 0-10ppm of chlorine dioxide.
Sensors output a 4-20mA signal. Membrane cap and fill solution are easily replaceable to maximize sensor life | |||||||||
Sensors can be used in new installations with Omicron's flow cell or installed as replacement for other4-20mA output ClO2 (Consult Omicron for compatibility). | |||||||||
An optional flow meter is available to help provide consistent flow for added system stability Special Features :
|
Measuring Range | 0-2 or 0-10 ppm ClO2 |
pH Range | 4-11 |
Body Material | PVC |
Temperature Range | 0 - 45 Degrees C |
Maximum Pressure | 14.7 psig (1 Bar) |
Temp Comp | Integrated |
Cable Length | 10 feet 2 conductors, tinned leads |
Process Connection | flow cell 1/4 inch FNPT threads |
Output | 4-20mA |
Flow Range | Min 0.2gpm (45 l/hr), Max 0.6gpm (135 l/hr) |
Supply Voltage | 12-24V DC, 250mA minimum |
Cross Sensitivity | Ozone, Free chlorine, monochloramine |
Chemical Compatibility | up to 50% ethanol/ water, up to 50% glycerol/water |
The CL series (free chlorine sensors) feature amperometric measurement technology. Designed for disinfection applications in water treatment, for, pools, etc., these sensors are available in three ranges for detecting ppm level of free chlorine. Choose the CL502 for 0-2ppm, CL505 for 0-5ppm and CL510 for 0-10ppm of free chlorine Typical applications include:Industrial wastewaterCooling waterBottle rinsing Irrigation water in agriculture Sensors output a 4-20mA signal scaled to 0-2 or 0-10ppm. Membrane cap and fill solution are easily replaceable to maximize sensor life. Sensors can be used in new installations with Omicron's flow cell or installed as replacement for other 4-20mA output free chlorine sensors.(Consult Omicron for compatibility). An optional flow meter (FM001) is available to help provide consistent flow for added system stability.
Special Features :Amperometric Sensor Technology | |
Real Time Continuous Measurement | |
Ranges: 0-2, 0-5 or 0-10ppm | |
Built-In Temperature Compensation | |
Large Electrolyte Reservoir | |
Replaceable Membrane and Electrolyte |
Measuring Range | 0-2, 0-5 or 0-10 ppm free chlorine |
pH Range | 5.5 - 8.5 |
Body Material | PVC |
Membrane Cap Material | PVC housing, Proprietary Membrane |
Temperature Range | 0 - 45 Degrees C |
Maximum Pressure | 14.7 psig (1 Bar) |
Temp Comp | Integrated |
Cable Length | 10 feet 2 conductors, tinned leads |
Process Connection | flow cell 1/4 inch FNPT threads |
Output | 4-20mA |
Flow Range | Min 0.2 gpm (45 l/hr), Max 0.6 gpm (135 l/hr) |
Supply Voltage | 12-24V DC , 250mA minimum |
Cross Sensitivity | Chlorine dioxide, Ozone, bromine, iodine |
The DO6400 & 7400 series dissolved oxygen sensors feature a large capacity electrolyte holder, positive fit, easy to replace membrane and dependable galvanic cell technology for long term deployment. The body design ensures a good grip when wet. Ideal for Aquaculture and wastewater monitoring applications, these sensors require minimal maintenance. PTFE or High-Density Polyethylene (HDPE) membranes are available.2 Replacement membranes, installation tool and electrolyte are included. Additonal maintennace parts are in convenient kits (see ordering information). Sensors with mV output as well as built-in 4-20mA output in 0-100% and 0-200% saturation range are available
Special Features :Large solution capacity for long term deployment | |
Models with and without temperature sensor | |
Easy installation and maintenance | |
mV or 4-20mA output models available |
O2 Measuring Range | DO6400, DO6400TC (0.520ppm), DO6441(0100%), DO6442(0-200%) |
DO7400, DO7400TC (0.03-20ppm), DO7441 (0100%), DO7442(0-200%) |
|
Body Material | Noryl |
Cathode | Silver |
Anode | Zinc (DO6400 Series), Lead (DO7400 Series) |
Maximum Temperature | 50 Degrees C |
Power Requirement | 12-36V DC (for models DO6441,DO6442,DO7441 and DO7442 only ) |
Temperature Sensor | (User specified temperature elements) Connect to your controller or PLC for temperature output |
Cable length | 10 feet, tinned leads |
Minimum Flow rate | 2 inches per second |
Output @ Air Saturation | HDPE DO6400 & DO7400 (45mV +/- 9mV) |
PTFE DO6400 & DO7400 (33mV +/- 9mV) | |
HDPE & PTFE DO6441, DO7441(0-100%) - fixed 4 - 4.5mA = <1 ppm DO | |
HDPE & PTFE DO6441, DO7441 (0-100%)- fixed 18-22 mA = saturated air | |
HDPE & PTFE DO6442- fixed 4 - 4.5mA = <1 ppm DO HDPE & PTFE DO6442- fixed 11-13 mA = saturated air |
The CS Current Sensor is a solid state transducer for measuring the current in fans, pumps and other HVAC equipment.Select one of three ranges by moving a jumper onthe device to operate over 10A, 20A and 50A. This sensor outputs 0-5V directly and requires no power supply. Clamping / Split Core Current Transformer is designed to provide a low cost method to monitoring electrical current.A unique hinge and locking snap allows attachment without interrupting the current-carrying wire. High secondary turn will develop signals up to 10Vac across a burden resistor.
Features : | ||||||||||
|
Power Supply | : | Not required | |
Operating Temperature | : | -20 ~ 60 OC | |
Operating Humidity | : | 0 ~ 95% RH | |
CT Material | : | ABS (UL94) | |
CT Ranges | : | 10, 20, 50Amp, jumper selected | |
Output Signal | : | 1~5VDC; porportional to average current | |
Accuracy | : | 2% | |
Plastic housing | : | Flammability rating UL94V0 file E194560 |
Omicrons Passive Infrared Occupancy Sensor is a low cost comercial and residential surface mount occupancy sensor. Advanced filtering reduces false triggering due to air movement and lighting changes. The sensor switches a dry contact which is wired to a separate controller. There is a tamper switch terminal as well, when the enclosure is opened up the central controller will be able to signal an alert. Main Features:- Intelligent logic control, anti false alarm efficiently- Auto temperature compensation- Pulse count adjustment- Anti white light interference- Anti RF interference (20V/m-1GHz)- Fresnel lens- Wall installation- SMT design adopted- Alarm output N.C./N.O. Optional
Operating voltage | : | 12VDC / 24 VAC | |
Current consumption | : | <18mA (24VAC) | |
Detecting distance | : | 12m | |
Detecting angle | : | 110° | |
Self-testing time | : | about 60S | |
Operating temperature | : | 10~+50°C | |
Alarm indicator | : | red LED | |
Alarm output | : | N.C.or N.O., DC28V, 100mA | |
Anti dismantle output | : | N.C., DC28V, 100mA | |
Range of coverage | : | 11 distance, 8 middle, 5 vicinities | |
Sensor | : | dual element infrared sensor | |
Operating temperature | : | -10 ~ +50°C | |
Environment humidity | : | 95%RH (non condensing) | |
Anti RF interference | : | 10MHz ~ 1GHz 20V/m | |
Installation mode | : | wall mounted or hanged in corner | |
Installation height | : | 1.7 ~ 2.5m (2.2m is Proposed) | |
Outline Size | : | 59(L) * 39.5(W) * 107(H) mm |
The SV100 range of Seismic sensors is designed to detect specific vibrations arising from attempts to penetrate high value storage units, protecting them against intrusion. The SV100 model is a universal seismic sensor which can be used to protect Vaults, Doors, fixed ATMs, Safes and other solid structures. The SV100 series offers several unique features that reduce installation time including integrated EOL resistors, a built-in diagnostic tool and the smallest footprint available on market
Power Requirement | |||
Supply Voltage | : | 8 – 16 VDC, nominal 12 VDC | |
Current Consumption | : | Typical 3 mA @ 12 VDC | |
Sensitivity | |||
Adjustable Sensitivity | : | 4 levels by DIP Switches | |
ATMs / Vault Selection | : | by DIP switch | |
Delayed Triggering | : | N/A | |
Reduced Sensitivity Input | : | For maintenance & Service: Active low (<1.5 VDC) | |
Detection Radius | : | 5m | |
Alarm algorithm | : | Highly sensitive to all known attacks while rejecting known false alarm sources by innovative filters and firmware |
|
Alarm Outputs | |||
Solid State Relay (Change Over) |
: | 30 VDC / 100 mA; Type C | |
Open Collector | : | Approx. 2.5 secs | |
Alarm Hold Time | : | Approx. 2.5 secs | |
Sabotage Protection | |||
Pry-off and Cover Switch | : | 30 VDC / 100 mA | |
Low Supply Voltage Alarm * | : | < 7 VDC | |
Temperature Alarm * | : | +85°C ± 5°C | |
Internal Functional Alarm* | : | Stainless steel drill shield |
The FS1000 is an insertion type airflow sensing element designed for quick, easy installation through a small cutout in the existing ductwork. Where multiple elements are required for proper duct traversing, the output ports are manifolded together, external to the ductwork. Each element is furnished complete with mounting hardware and sealing gaskets. Standard aluminum elements also include all brass compression fittings required to manifold the elements together. The FS1000 airflow sensing element is a head type device, which generates a differential (velocity) pressure signal similar to the orifice, venturi, and other head producing primary elements. The FS1000 is constructed so that strategically located sensing ports (based on duct size) continually sample the total and static pressures, when inserted normal to flow. The total pressures sensed by the upstream ports are continually averaged within the element in an isolated chamber. The static sensing ports (located where the influence of the velocity head is zero) are averaged in a second isolation chamber. Each chamber is then connected to one side of a differential measurement device (gauge, transmitter, etc.) for flow measurement and indication purposes.
Special Features :Low signal-to-noise ratio | |
Multiple total and static pressure sensing ports along the length of the element | |
Averaging internal manifold | |
Insensitive to flow angle variations of as much as 20 when faced in the normal direction of flow | |
2% accuracy throughout the velocity rages of 100 fpm and over | |
Standard construction is 6063-T5 aluminum with anodized finish | |
Available in optional corrosive resistance materials including Type 316L stainless steel, Hastaloy, and Type 1 PVC | |
Standard elements can be operated (in air) continuously in temperatures up to 350F or inter mittently in temperatures up to 400F | |
All elements can be operated in humidity ranges of 0 to 100% | |
Standard elements have good salt air and mild acid resistance; excellent solvent and aromatic hydrocarbon resistance |