Our Products
We are leaders in the market for providing best range of 6310 : Combustible Gas Detector, WJL6000 : Refrigerant Gas Detector, AZ - 7753 : CO2 Detector, CDM : Duct Mounted Carbon Dioxide Transmitter and CDW-LCD : Wall Mounted Carbon Dioxide Transmitter with Display
Easy-to identify and pinpoint gas leaks | |
Portable and high sensitivity | |
Alarm at 10%-40% Level | |
Resume original measurement state in 7-10 minutes in pure air | |
solvents, lacquer thinner, naphtha | |
Warming up time: 2 minutes | |
Response time: 2 seconds | |
Gas detected: natural gas, methane, ethane, propane, butane, acetone, alcohol, ammonia, steam, carbon monoxide, gasoline, jet fuel, hydrogen |
Detect leaks of all halogenated refrigerants in any refrigeration, air-conditioning systems etc. The typical examples of halogenated refrigerants are: | |
CFCs e.g. R12, R11, R500, R503 etc | |
HCFCs e.g. R22, R123, R124, R502 etc | |
HFCs e.g. R134a, R404a, R125 etc | |
Blends e.g. AZ-50, HP62, MP39 etc | |
Detect Ethylene Oxide gas leaks in hospital sterilizing equipment (it will detect the halogenated carrier gas) | |
Detect SF-6 in high voltage circuit breakers | |
Detect most gases that contain chlorine, fluorine and Bromine (halogen gases) | |
Detect cleaning agents used in dry cleaning applications such as perchloroethylene | |
Detect halogen gases in fire extinguishing system | |
Detects all kinds of halogenated refrigerants | |
Sensitivity adjusted at any time and it can be adjusted automatically to the best state of detecting | |
Audible alarm and flashing light indicator upon gas leakage detected | |
Inner precise IC with ultra-low consume circuit design, more stable, longer battery time | |
Two color visual display of battery voltage | |
Excellent sensor, high sensitivity, longer use time |
Low cost portable meter checking indoor air quality | |
Big dual display lcd with 2 parametersSimultaneously: CO2 , Temperature | |
Design with ndir (non-dispersive infrared)Wave guide technology sensor | |
Manual calibration is recommended | |
Warning carbon dioxide level | |
Backlight function for working in dark | |
Longtime drift compensation | |
Audible alarm (-80db) threshold setting | |
Max , min, average functions included | |
RS232 output every 2 seconds to pc for analysis | |
Hold function freezes current readings | |
Display 8 hrs twa value (time-weighted average) Or 15 minutes stel value (short-term exposure limit) | |
Housing designed surrounds with rails to help Air ventilation for quick and accurate response | |
Easy to calibrate at fresh air around 380-420ppm |
Omicron carbon dioxide transmitters are designed for environment monitoring and controlling in industrial and commercial buildings. These transmitters can be used for:
These transmitters can be used for | |
Air monitoring of supply, exhaust and return air | |
Air monitoring in critical environment such as outside air | |
Other applications of combustion measurement |
Omicron carbon dioxide transmitters are designed for environment monitoring and controlling in industrial and commercial buildings. These transmitters can be used for:
These transmitters can be used for | |
Air monitoring of supply, exhaust and return air | |
Air monitoring in critical environment such as outside air | |
Other applications of combustion measurement |
Sensor | Digital NDIR |
Range | 0~2000 ppm |
Output | 4~20mA(2 wires)�0~10VDC(3 wires) |
Accuracy | ±3% |
Hysteresis | <±1%RH |
Response time | <10s(25°C,in slow air) |
Drift | <±0.5%RH/year |
LCD | Optional |
Power | 24VDC |
Output Load | 500Ω (current), >2KΩ (voltage) |
Temperature Limit | -20~80°C |
Storage Temperature | -40~100°C |
Protection | Fireproof ABS Enclosure |
Housing | IP30 |
Omicron carbon dioxide transmitters are designed for environment monitoring and controlling in industrial and commercial buildings. These transmitters can be used for:
| ||||||||||||||
Special Features :
|
Sensor | Digital NDIR |
Range | 0~2000 ppm |
Output | 4~20mA, 2~10VDC |
0 - 20mA, 0 - 10VDC | |
Display | LCD Display |
Accuracy | ±3% |
Hysteresis | <±1%RH |
Relay | Preset SPST NO Relay |
1000ppm activation, 900 ppm deactivation | |
Response time | <10s(25°C,in slow air) |
Drift | : <±0.5%RH/year |
LCD | Optional |
Power | 24VDC |
Output Load | 500Ω (current), >2KΩ (voltage) |
Temperature Limit | -20~80°C |
Storage Temperature | -40~100°C |
Housing | Fireproof ABS Enclosure |
Omicron carbon dioxide transmitters are designed for environment monitoring and controlling in industrial and commercial buildings
These transmitters can be used for | |
Air monitoring of supply, exhaust and return air | |
Air monitoring in critical environment such as outside air | |
Other applications of combustion measurement |
| ||||||||||||||
Sensor | Digital NDIR | |
Range | 0~2000 ppm | |
Output | 4~20mA(2 wires)�0~10VDC(3 wires) | |
Accuracy | ±3% | |
Hysteresis | <±1%RH | |
Response time | <10s(25°C,in slow air) | |
Drift | <±0.5%RH/year | |
LCD | Optional | |
Power | 24VDC | |
Output Load | 500Ω (current), >2KΩ (voltage) | |
Temperature Limit | -20~80°C | |
Storage Temperature | -40~100°C | |
Housing | Fireproof ABS Enclosure |
Omicron carbon Monoxide transmitters are designed for environment monitoring and controlling in industrial and commercial buildings. These transmitters can be used for:
Air monitoring of supply, exhaust and return air | ||||||||||||||||||
Air monitoring in critical environment such as outside air | ||||||||||||||||||
Other applications of combustion measurement Special Features :
|
Sensor | : Digital Semiconductor | |
Range | : 0~250 ppm | |
Output | : 4~20mA(4 wires)�2~10VDC(4 wires); Jumper Settable | |
Accuracy | : ±10% of F.S | |
Hysteresis | : <±1%RH | |
Response time | <120s (25°C,in slow air) | |
Sampling Time | 1s | |
Drift | : <±1%RH/year | |
LCD | : Optional | |
Power | : 24V AC / DC | |
Output Load | : 500Ω (current), >2KΩ (voltage) | |
Temperature Limit | : -10~50°C | |
Storage Temperature | : -30~60°C | |
Housing | : Fireproof ABS Enclosure |
Omicron carbon Monoxide transmitters are designed for environment monitoring and controlling in industrial and commercial buildings. These transmitters can be used for:
Air monitoring of supply, exhaust and return air | |
Air monitoring in critical environment such as outside air | |
Other applications of combustion measurement |
High performance semiconductor sensors and circuits, ensure accurate measurement and temperature compensation | |
Good long term stability and reliability | |
15 Years Sensor Life | |
Fast response | |
Digital technology applied, multiple output optional, over voltage and reverse polarity protection, high reliability and interference capability | |
Fast Response | |
High protection rate up to IP65 |
Sensor | : Digital Semiconductor | |
Range | : 0~250 ppm | |
Output | : 4~20mA(4 wires)�2~10VDC(4 wires); Jumper Settable | |
Accuracy | : ±10% of F.S | |
Hysteresis | : <±1%RH | |
Response time | <120s (25°C,in slow air) | |
Sampling Time | 1s | |
Drift | : <±1%RH/year | |
LCD | : Optional | |
Power | : 24V AC / DC | |
Output Load | : 500Ω (current), >2KΩ (voltage) | |
Temperature Limit | : -10~50°C | |
Storage Temperature | : -30~60°C | |
Housing | : Fireproof ABS Enclosure |
Available in all sheath diameters Lead wires of your choice. Bearing Temperature measurement, Used by equipment/ instrument manufacturer.
This design is specifically used to measure skin temperature of heater tube or flat surface. Typical applications are measurement of surface temperature of refactory lined vessels, columns, reactors in Petrochemical plants & oil Refineries & pipelines.
This design is specifically used to measure skin temperature of heater tube or flat surface. Typical applications are measurement of surface temperature of refactory lined vessels, columns, reactors in Petrochemical plants & oil Refineries & pipelines.
Tri clamps are available in size of 1.5", 2", 2.5" . Mounting is very easy & quick . Reference standard :- IEC - 751.
Such Design is generally used in all industries, machinery manufacturers, bearing temperature measurement, etc. where space is limited.
Special Features :Mineral Insulated | |
Available in all sheath diameters | |
Mineral Insulation enables flexibility and durability | |
Class A Tolerance as per IEC-751 | |
Enclosures in all Categories |