Our Products
Pumps, Pumping Machines & Parts
2 Products availableFlowmeters And Thermometers
2 Products availableFuel Injection System
1 Products availableAudio Recorders, Mixers & Transmitters
1 Products availableRotameters
1 Products availableFlow Meters
1 Products availableWe are leaders in the market for providing best range of Battery Operated Turbine Flow Meter, Domestic Water Meter, Diesel Generator Fuel Consumption Meter, Paddle Wheel Flow Meter and Ultrasonic Thickness Meter
Features
Mostly used in applications such as petroleum, petrochemical and process control, Oval Gear Flow Meter works on the principle of allowing fluid to enter the inlet port and then passing through the metering chamber. Inside the metering chamber, fluid forces the internal gear to rotate before exiting the outlet. The wide range of Oval Gear Flow Meter comes in different specifications, as per the need of the client. Furthermore, Oval Gear Flow Meter is known for its smooth functioning, compact design, accuracy, and enhanced functionality.
Features
Additional Information:
Payment Terms : T/T,
Specifications
Model /Size | Flow Range | Std.Fitting | Accuracy in % |
---|---|---|---|
2805/ 6 NB | 1-50 LPH | ¼ “ BSP | 1.0 |
2811/ 6 NB | 5-100 LPH | ¼ “ BSP | 1.0 |
2812/ 6NB | 25-500 LPH | ¼” BSP | 1.0 |
815/15 NB | 1-35 LPM | ½” BSP | 0.5 |
2820/20 NB | 1-35 LPM | ¾” BSP | 0.5 |
2825/25 NB | 6-120 LPM | 1” BSP | 0.5 |
2840/40 NB | 10-250 LPM | 11/2” BSP | 0.5 |
2850/50 NB | 15-350 LPM | 2” BSP | 0.5 |
2875/80 NB | 66-616 LPM | 3” FLANGE | 0.5 |
Details
Catalogue
Features :
Applications :
The Electromagnetic Flow Meter works on the principle of electromagnetic induction and requires conducting fluid for measuring pressure. Our range of Electromagnetic Flow Meter is widely acknowledged for its accuracy, reliability and long service. The Electromagnetic Flow Meter provided by us comes with various accessories such as converters, indicating Totalisers, grounding rings etc. Furthermore, the Electromagnetic Flow Meter is extremely compact in design.
Additional Information:
Payment Terms : T/T,
Principle Of Operation
The Principle employs faradays law of electro magnetic induction Which States an electro motive Force (emf) is induced across the Conductor which Moves through the magnetic field at Right angles.The Induced Voltage Directly Propotional to the conductor (Fluid) Velocity.
A Magnetic Field is genarated by Compact high density coils mounted to a short section of straight pipe.As a conductive Liquid Passes Thru The Pipe Section and It’s a Magnetic Field,a Voltage is genarated that is propotional to the Velocity of the conductive liquid.
The Voltage Induced Is Sensed by electrodes mounted by right angles to the magnetic field and in contact with the conductive liquid (or) Slurry. From the electrodes the voltage is transmitted to a Signal Converter Where it is conditioned to the desired output signals.
NXL Magnetic flowmeter genarates an open collector frequency ( Propotional to the Liquid Velocity ) of 10 KHz at Maximum Flow Rate. The Standard analog Output is 4-20 mA (or) 0-20 mA DC into a 600 ohms Max Load.
Specifications
Flow Range | 0.03 to 10 m/s |
---|---|
Accuracy | +/- 1% of Flow Rate (Optional +/- 0.5 % ) of Flow Rate. |
Max Working Temp |
Up to 65oCAmbient. Up to 150oC InProcess for PTFE Lining Upto 80oC in Process for Rubber Lining |
Repetabilty | 0.3 % |
Power Required | 115 VAC /230VAC +/- 10 % (Jumper Selectable) 24 VDC (Optional) |
Connections | Flanged ( F Type) /Triclamp Between Flanges ( W Type) |
Liner materials | PTFE/Rubber Lined /Polyruthene |
Housing Material | Cast Aluminium |
Electrode Material | 316 SS (Optional : Monel,HastC,Tantalum,Titanium, Platinum with 10% Iridium ) |
Capacities
Pipe Size | Max Flow Rate At 10 m/s |
Min Flow Rate at 0.5 m/s |
---|---|---|
1/4" ( 6 mm) | 17 LPM | 0.85 LPM |
1/2" ( 12 mm) | 106 LPM | 5.30 LPM |
1" ( 25 mm) | 300 LPM | 15.00 LPM |
11/2"( 40 mm) | 750 LPM | 37.70 LPM |
2" ( 50 mm) | 1200LPM | 60.00 LPM |
3"( 75 mm) | 180 M3/Hr | 9.0 M3 /Hr |
4" ( 100 mm) | 280 M3/Hr | 14.0 M3/Hr |
6"(150 mm ) | 630 M3/Hr | 31.5 M3/Hr |
8" (200 mm) | 1130 M3/Hr | 56.5 M3/Hr |
10" (200 mm) | 1760 M3/Hr | 88.0 M3/Hr |
The company is a highly acclaimed Manufacture, Exporter and Supplier of Thermal Mass Flow Meter. The Thermal Mass Flow Meter belongs to the NXL-27 Series of mass flow instruments known for their accurate measurement and effective control of gas controls. The flow sensor of the Thermal Mass Flow Meter produces an electrical output signal for the indication and recording or the control processes. The signal is linear with the flow rate and the flow sensor is the heart of the Thermal Mass Flow Meter. Providing a stable gas flow, the Thermal Mass Flow Meter eliminates any requirement of constant monitoring and gas pressure readjustment.
Design Features
Accessories : Power Supply With Digital Indicating Totaliser
Ordering Information
Additional Information:
Payment Terms : T/T,
Specifications
Flow Ranges | 0 - 160 SLPM Air,Nitrogen,Hydrogen,Oxygen,Heliu m And Argon(other Gases and Ranges available.Please Contact Factory) |
Output | 0-5 VDC into 2000 ohm Load |
Power | + 15 VDC (+/- 5%) at 35 mA and –15 VDC (+/- 5%) at 10 mA |
Power Consumption | 0.6 Watts Max. |
End Connections | Compression Ftg |
Electrical connections | D Type Conn. Max Operating Pressure: 4500 PSIG |
Temp | 4 to 65oC |
Performance | |
Accuracy | +/- 1% F.S |
Repeatability | 0.25% of Rate. |
Catalogue
We are among the distinguished Manufacturers, Exporters and Suppliers of Turbine Flow Meter. Turbine Flow Meter operates on the principle of motion, where the flow meter senses the spinning of the rotor inside and converts it into pulsating electrical signal. Turbine Flow Meter provides an accurate performance and is highly acknowledged for its smooth operation, robust construction and longer service life.
Additional Information:
Payment Terms : T/T,
Specifications
Op Pressure | Defined By Endconnections upto 400 bar |
---|---|
Pick Off Type | Magnetic Output 15 to 20 mV min |
Temparature | -20 Deg C to 80 Deg C |
Linearity | +/- 0.5% of Reading |
Repeatability | +/- 0.05% of Reading |
Display | 6 digit LCD ( Total Mode ) 4 digit LCD ( Flowrate Mode ) |
Power Supply | Self Powered-replaceble Lithium Batteries ( Optional ) External 8-24 V dc via 4-20mA loop |
Enclosure | IP 66 ( Mounted on the Meter ) |
Units ( Total) | Litres,Gallons,Cubic Meters |
Time ( Rate ) | Per Second,Minutes,Hour |
K Factor Range/Decimals | Programmable |
Data input | Via Keys |
Analogue Output | optional 2 Wire 0/4-20mA, 12-24V dc into 750 ohms @ 24 V. |
Linearisation | Up to 10 Points.( optional ) |
Indications | Low Battery Indication |