1 Products availableWe are leaders in the market for providing best range of Anion Resin, Boiler Chemicals and Dosamatic
Activated carbon filters are used for removing free chlorine, phenol, taste and odour as well asreduction COD/ BOD. The specially designed filtersare made from FRP closed vessel fittedwith multi port valves and are operated under pressure. The water is passed through the underbed media &granular activated carbon layer. These filters have a back flushing arrangement, which easily flushes away the deposited impurity at carbon granules. Activated carbonfilter, forremoval offree chlorine, phenol, taste and odour as well as reduction COD / BOD.Granular Activated Carbon is a well establishing & proven technology for the removal of taste, odours and gases from water.It is extremely effective in the removal of many Volatile Organic Compounds (VOC) and other Petroleum-based contaminants. The Ultra Safe Filters use Granular Activated Carbon, manufactured from hard coconut shell having Iodine content of 900-1000 ppm, whose extraordinary molecular structure adsorbs much more molecules of contaminant molecules that adhere to its surface, through absorption and adsorption. Special Features
MODEL |
VALVE |
TOP / SIDE |
15 |
¾” ( 20 NB ) |
TOP |
30 |
¾” ( 20 NB ) |
TOP |
60 |
¾” ( 20 NB ) |
TOP |
80 |
¾” ( 20 NB ) |
TOP |
100 |
1 ½” (40 NB) |
TOP |
150 |
1 ½” ( 40NB ) |
TOP |
200 |
1 ½” ( 40NB ) |
TOP |
250 |
1 ½” ( 40NB ) |
SIDE |
330 |
1 ½” ( 40NB ) |
SIDE |
450 |
1 ½” ( 40NB ) |
SIDE |
750 |
1 ½” ( 40NB ) |
SIDE |
1000 |
1 ½” ( 40NB ) |
SIDE |
UV systems will protect you from living organisms in your water such as bacteria and cysts. Ultraviolet (UV) water purification systems are trusted by thousands of people worldwide for use in homes, cottages, and in many industrial and commercial applications. UV systems come in a variety of sizes and can be used to purify the water for a single faucet or for an entire home or larger building. UV systems are superior to chemical water disinfection because they don't add any harmful chemicals to the water, or to the environment.
MICRO BIOLOGICAL PROBLEM IN VARIOUS INDUSTRIES:
Pharmaceuticals Industry : # Bacterial count in process water. # Bacterial growth in sand filter, Carbon filter, D.M. Plant.# Decreased shelf life of the R.O. Membrane, Resin & Filter beds etc.Bottling Industry : # Decreased shelf life of the end mineral water, Soft Drink, product.Dairy Canneries : # Contamination of bottles. # Bacterial growth in Sand filter, Carbon filter, D.M.Plant.Food & Beverage Industry : # Decreased shelf life of the end product.Fish Hatcheries : # Whirling disease.# Increased fish mortality. Paint Industry : # Decreased shelf life of the water based paints.Poultry Industry : # Increased bird mortality.
Specification:
Main Feature:
OPTIONAL ACCESSORIES :
QUALITY CONTROL:
Every U.V lamp & Quartz jacket Silica individually checked and each completed System tested and run before dispatch
Check Stainless steel & silicon material i.e. Gasket, o Ring with Validation certificates. Our comprehensive after sales service includes a full range of spares and professional technical backup, with an optional Annual Maintenance Contract in all over India.
CONVENTIONAL METHODS OF WATER TREATING |
|||
|
CHLORINE |
OZONE |
ULTRA VIOLET |
Capital cost |
Lowest |
High |
Low |
Ease of installation |
Good |
Poor |
Excellent |
Ease of Maintenance |
Good |
Poor |
Excellent |
Cost of Maintenance |
Medium |
High |
Lowest |
Operating Cost |
Low |
High |
Low |
Frequency Of Maintenance |
Frequent |
Continuous |
V. Infrequent |
Control System |
Poor |
Good |
Excellent |
Virucidal Effect |
Good |
Poor |
Good |
Toxic Chemical |
Yes |
Yes |
No |
Residual Effect Problem with |
Yes |
Yes |
No |
Hazards |
High |
Yes |
Low to none |
Contact Time |
30 - 60 minutes |
High |
1 – 5seconds |
Disinfection Performance |
Leaves some pathogens |
Kills all microbes |
Kills all microbes |
Effect on Water |
Organochlorine compounds, Taste & pH changes |
Unknown |
None |
The Ultra violet dose required for destruction is about the same for each virus, while higher dose of chlorine & ozone needed. |
MIROBIAL STANDARDS FOR DRINKING WATER |
|||
Test |
W.H.O. |
U.S.P.H.A. |
SWE Standard |
Total Bacterial Count |
Test not specified |
500 organisms/ml. |
Les than 500 organisms/ml. |
Coli form |
95% of sample should not coli forms & maximum 10 coliforms/100ml. |
95% of sample should not contain coli form |
NIL ( Coli forms ) |
E-Coli |
No E.Coli in 100ml. |
No E.Coli in 100ml. |
NIL ( E. Coli ) |
SR.NO | FLOW RATE /HRS | MODEL NO | INLET & OUTLET |
NO.UV LAMP & Q .JACKET |
POWER( WATTS) |
1. | 150 LPH | SWE - 1 | ½” THRD | 1 | 8 |
2. | 250 LPH | SWE - 2 | ½” BSP | 1 | 16 |
3. | 500 LPH | SWE – 2X2 | ¾” BSP | 2 | 16 |
4. | 750 LPH | SWE 4X2 | ¾” BSP | 2 | 32 |
5. | 1500 LPH | SWE 8 | ¾” BSP | 1 | 39 |
6. | 3000 LPH | SWE 16 | 1” BSP/25 NB | 2 | 80 |
7. | 5000 LPH | SWE 50 | 1.5” BSP /40 NB | 3 | 120 |
8. | 7500 LPH | SWE -32 | 1.5” BSP / 40 NB | 4 | 160 |
9. | 8 m3 – 10 m3 | SWE – 100 | 2”BSP/50 NB | 6 | 240 |
10. | 12 m3 – 15 m3 | SWE – 150 | 2”BSP/50 NB | 8 | 320 |
11. | 20 m3 – 25 m3 | SWE – 250 | ( 2 Chamber ) 50NB | 12 | 480 |
12. | 30 m3 – 35 m3 | SWE - 350 | ( 2 Chamber ) 50NB | 16 | 640 |
13 | 40 m3 – 45 m3 | SWE – 450 | ( 3 Chamber ) 80NB | 18 | 720 |
14 | 55 m3 – 65 m3 | SWE – 650 | ( 4 Chamber ) 80NB | 24 | 960 |
COOLING TOWER CHEMICAL: Whether your cooling tower is large or small, it has chemical treatment requirements that must be met accurately and reliably to control corrosion, scale and deposits. Chemicals injected include:
Until now, your choices in treatment systems were limited: You could obtain an unreliable, minimum-capability system from your chemical supplier Or you could spend your design resources on a custom-built system. Either way, it was hard to get the right combination of capability and cost. We have Solution for above problems they are:
Aquablend04 ScaleAQUABLEND- 04 is a liquid formulation designed protects ferrous as well as copper equipment from recirculating cooling water system. It contains no heavy metal formulation and powerful scale inhibitor to control precipitation of calcium phosphates, carbonate & sulphate. Along with a catalyst it also contains dispersant to keep suspended matter such as silt, metal oxides, etc in dispersed form avoiding deposition on heat exchangers Aquablend QAT BiocideAQUABLEND-QAT is biodegradable , wide spectrum organic liquid micro biocide based on quaternary ammonium compounds used in industrial recirculating cooling water systems. AQUABLEND-QAT controls build up of biological slimes & sulphate reducing bacteria Aquablend PNT BiocideAQUABLEND-PNT is a powerful anti foulant for treatment of recirculating cooling water. It is a wide spectrum liquid microbiocide for checking microbiological growth. AQUABLEND-PNT controls build up of trouble-some bactria in industrial cooling water.a powerful dispersant keeps slit & similar foulants in suspension
We offer a wide range of Polyelectrolytes, which is vastly used as emulsifiers, thickeners in various areas such as food, cosmetics, shampoo and soaps. These Polyelectrolytes have water solubility features and thus these are highly demanded in medical and bio-chemical sectors for further processing into various components. Our range of polyelectrolyte is available in different types such as anionic & cationic as well as in non-ionic polyekectrikttes type.
Polyelectrolyte is widely used to purify drinking water, treat waste water, produce paper, extract precious minerals and cover a whole host of other applications. Synthetic polyelectrolyte is essential for health as well as for environmental benefits.
Ideal for all basic water testing applications. The best value meter in the world!
FeaturesSpecifications Range:0 - 9990 ppm (mg/L) Resolution:1 ppm (0-999 ppm); 10 ppm (1000-9990 ppm) Accuracy:+/- 3% Conversion Factor:NaCl (avg. 0.5) Power source:2 x 1.5V button cell batteries (included) Battery life:Approx. 1000 hours of usage Dimensions:15.5 x 3.1 x 2.3cm (6.1 x 1.25 x 1 inches) Meter weight:56.7g (2 oz) Weight with package:76.5g (2.7 oz)
This product is shaped by winding on thermoplastic liners with composite material, which contains epoxy resin and fiber glass.Compared to steel vessels with the same specifications, our FRP vessels featured high strength, light weight, excellent corrosion resistance and long service life. Feature and Applications:
Specifications: Materials :Polyester shell, FRP shell and Glass Fiber wounded. Operation Temperature :49(120 F) Max Operating Pressure:150 psi Optional Color :Natural White, Blue Opens of all tanks can be customized, within the range of NPSM 2.5", UN 4" and Flange 6" for option.
Sr. No. |
Model No. |
Description |
Inner Liner |
Tank Capacity |
1 |
844 |
2.5” Top Opening |
PE |
33 |
1 |
10 X 54 |
2.5” Top Opening |
PE |
62 |
2 |
12 X 52 |
2.5” Top Opening |
PE |
83 |
3 |
13 X 54 |
2.5” Top Opening |
PE |
104 |
4 |
14 X 65 |
2.5” Top Opening |
PE |
148 |
5 |
16 X 65 |
4” Top Opening |
PE |
212 |
6 |
16 X 75 |
4” Top Bottom Opening |
PE |
240 |
7 |
20 X 69 |
4” Top Bottom Opening |
FRP |
339 |
8 |
24 X 72 |
4” Top Bottom Opening |
FRP |
487 |
9 |
30 X 72 |
4” Top Bottom Opening |
FRP |
742 |
10 |
36 X 72 |
4” Top Bottom Opening |
FRP |
1017 |
AQUASOLare complete systems available in one package, for reliable testing.Any time. Anywhere. AQUASOLsystems are extremely simple and easy to use. You neither have to be a trained chemist nor require any experience to get reliable results from these systems. AQUASOL makes monitoring convenient and quick. Thus preventive action can be taken immediately.Based On Proven Laboratory Methods Backed By Sound Chemical Research
AQUASOLare systems based on standard and established analytical methods, backed by chemical research. These are simple adaptations of classic chemical analytical methods. The analytical methods are based on Standard Methods For Examination Of Water And Waste Water prepared by American Public Health Association (APHA), American Water Works Association (AWWA), different pharmacopoeias and other standard methods.You can have complete confidence in the results you obtain from AQUASOL, as they are extremely reliable.AQUASOLsystems replace conventional analytical methods such as Titrimetric, Colorimetric and Spectrophotometric by simple drop test & standard colour comparison methods.
AQUASOLreagents are completely ready to use, conveniently packed, and therefore user friendly.Now you do not have to bother about reagent preparations and standardization.Our drop count procedures and suitable colour comparisons are also economical.
AQUASOLGives You Freedom From The Need Of A Laboratory, Trained Manpower And Laborious Processes Involved.
Ion exchange technology is used to remove salts (cations and anions) from the water Soluble chemical compounds, when dissolved in water, become ionized; that is their molecules dissociate into positively and negatively charged components called ions. Consider common table salt, sodium chloride. In its solid form, this compound consists of one sodium atom (Na) and one chlorine atom (Cl) tightly coupled together (NaCl). When dissolved in water, however, the compound splits into two ions, Na and Cl. Ion ExchangeA process in which Contaminant ions are exchanged from water is called ion exchange. This process occurs in ion exchange resin Initially, resin is loaded with hydrogen (H ) ion for cations and hydroxide (OH-) ion for anions. As water passes through the resin, the contaminant ions in the water displace the loaded ions from the sites on the resin. This is because the resin has a greater affinity for the contaminant ions. Affinity for most resins is based loosely on ionic size and charge RegenerationOver a period of time most of the cation resin gets converted into Ca, Mg, Na form and it has no Hydrogen Ions (H ) to replace Ca, Mg, Na ions and the anion resin gets converted into Cl, SO4, SiO2 form and it has no Hydroxyl Ions (OH-) to replace Cl, SO4, SiO2 ions. This is called the resin exhaustion or end of service cycle. The exhausted resin has to be brought back into Hydrogen (H )Hydroxyl (OH-) form to continue the process and use it again and again. The procedure of converting exhausted resin into Hydrogen (H )Hydroxyl (OH-) form is called regeneration Separate Bed DM SystemsIon exchange occurs across at least two different columns. The first is a cation column, which is filled with resin loaded with positive hydrogen ions (H ). As water passes through this column, the positively charged impurities in the water are exchanged for the hydrogen ionsA similar exchange takes place in the second column, the anion column. This column is filled with resin loaded with negative hydroxide ions (OH-). As the now cation-free water from the cation column passes through, any negatively charged contaminants are removed from the water and replaced by hydroxide ions from the resin. The water now has a neutral pH. hydroxide [OH-] and hydrogen [H ] ions exchanged in the columns combine, forming water [H2O) Mixed Bed Systems In a Mixed Bed System water is purified by removing all ions in one pass through an ion exchange bed. The bed consists of cation and anion resins in mixed condition, so that ions are actually removed in the same two step ion exchange process. All the traces of Cations and Anions of the dissolved solids and silica in the water are replaced by Hydrogen ion (H) and Hydroxyl Ion (OH-) respectively. We get very high purity demineralized water at the outlet of the MB.
MODELS |
Numa DM |
Numa DM |
Numa DM |
Numa DM |
Resin Qty. |
30 Ltr |
60 ltr. |
80 ltr. |
100 ltr. |
OBR @ 100 ppm ionic Load |
12,000 ltrs |
24,000 ltrs. |
32,000 ltrs. |
40,000 ltrs |
Min. Working Pr. |
2.0Kg/cm² |
2.0 Kg /cm² |
2.0 Kg /cm² |
2.0 Kg/cm² |
Max. Working Pr. |
4.0Kg/cm² |
4.0 Kg /cm² |
4.0 Kg /cm² |
4.0 Kg/cm² |
Vessel |
FRP |
FRP |
FRP |
FRP |
Resin Make |
Thermax |
Thermax |
Thermax |
Thermax |
Reagenerant Qty Acid & Alkali |
HCL / 9 Kg |
HCL / 18 Kg |
HCL / 24 Kg |
HCL / 30 Kg |
Type of Valve |
20NB |
20 NB |
20 or 25 NB |
25 or 40NB TM |
Max. Flow Rate. m3/Hr |
1.5 m3 / Hr. |
1.5 m3 / Hr. |
1.5 m3 / Hr. |
2.5 m3 / Hr |
MODELS |
Numa DM |
Numa DM |
Numa DM |
Numa DM |
Resin Qty. |
150 Ltr |
200 ltr. |
250 ltr. |
330 ltr. |
OBR @ 100 ppm ionic Load |
60,000 ltrs |
80,000 ltrs. |
1 Lacs ltrs. |
1.32 Lacs ltrs |
Min. Working Pr. |
2.0Kg/cm² |
2.0 Kg /cm² |
2.0 Kg /cm² |
2.0 Kg/cm² |
Max. Working Pr. |
4.0Kg/cm² |
4.0 Kg /cm² |
4.0 Kg /cm² |
4.0 Kg/cm² |
Vessel |
FRP |
FRP |
FRP |
FRP |
Resin Make |
Thermax |
Thermax |
Thermax |
Thermax |
Reagenerant Qty Acid & Alkali |
HCL / 45 Kg |
HCL / 60 Kg |
HCL / 75 Kg |
HCL / 100 Kg |
Type of Valve |
25 or 40 NB TM |
40 NB TM |
40 NB SM |
40 NB SM |
Max. Flow Rate. m3/Hr |
3 m3 / Hr. |
3 m3 / Hr. |
3 m3 / Hr |
4 m3 / Hr |
MODELS |
Numa DM |
Numa DM |
Numa DM |
Resin Qty. |
500 ltr. |
750 Ltr |
1000 ltr. |
OBR @ 100 ppm ionic Load |
2 Lacs ltrs. |
3 Lacs ltrs |
4 Lacs ltrs. |
Min. Working Pr. |
2.0 Kg /cm² |
2.0Kg/cm² |
2.0 Kg /cm² |
Max. Working Pr. |
4.0 Kg /cm² |
4.0Kg/cm² |
4.0 Kg /cm² |
Vessel |
FRP |
FRP |
FRP |
Resin Make |
Thermax |
Thermax |
Thermax |
Reagenerant Qty Acid & Alkali |
HCL / 150 Kg |
HCL /225 Kg |
HCL / 300 Kg NaOH /100 Kg |
Type of Valve |
40 NB SM |
40 NB SM |
40 NB SM |
Max. Flow Rate. m3/Hr |
4 m3 / Hr. |
2.0Kg/cm² |
2.0 Kg /cm² |
Weoffer durable pressure sand filters that are used for the removal of suspended solids & turbidity. The pressure sand filter is extremely robust methodofremovingsuspended solids fromwater. The filtration medium comprised of multiple layer of sand havingdifferent size &specific gravity. As per the needs of customers, we can offer sand filters in various sizes and material apart from hand operated or fully automatically, Filter is used for separating water suspended solid for better operation of filter, suspended solid should be coagulated. The advantages of pressure filter are high speed of filtration, less space, low charge and prevent heat loss after the warm or hot lime process. pressure filters, which may be vertical or horizontal, have cylindrical steel shells and dished heads. The flow in pressure filters is downward. Usually sand or anthracite is the filter medium in a bed consisting of either one or two grades of sand or anthracite. A gravel bed supports the filter medium, prevents fine sand or anthracite from passing into the under drain system and distributes backwash water. The water, which should be filtered, enters over the top of filter and pass from its bed then they collected at the bottom of filter. The suspended matter is strained out of the water and held in the voids between the filtering granules. The accumulation load of suspended matter in the bed causes an increasing loss of pressure during the filter run. When this loss reaches a predetermined limit, the filter is backwashed upward, discharging the suspended load out to the sewer.
MODEL |
VALVE |
TOP / SIDE |
15 |
¾” ( 20 NB ) |
TOP |
30 |
¾” ( 20 NB ) |
TOP |
60 |
¾” ( 20 NB ) |
TOP |
80 |
¾” ( 20 NB ) |
TOP |
100 |
1 ½” (40 NB) |
TOP |
150 |
1 ½” ( 40NB ) |
TOP |
200 |
1 ½” ( 40NB ) |
TOP |
250 |
1 ½” ( 40NB ) |
SIDE |
330 |
1 ½” ( 40NB ) |
SIDE |
450 |
1 ½” ( 40NB ) |
SIDE |
750 / 750 |
1 ½” ( 40NB ) |
SIDE |
1000 |
1 ½” ( 40NB ) |
SIDE |
Activated Carbon is porous from of Carbon manufactured from internal surface area.
The porosity Creates a remarkable power of Adsorption, an indispensable Process in industrial separation.
Purification, decolonization & recovery technique. The Carbon atoms at the internal surface of Activated Carbon.
Exert an attraction ( Vendor waars force ) on the molecules of surrounding liquid & gas & fixes on to its pore walls.
This is the basis of mechanism whereby Activated Carbons may be used to remove one or more components from a mixture.
GRANULES In GASPHASE adsorption, Granular Carbon is almost always used because the Pressure drop in the Carbon bed is of prime importance & Granular Carbon will allow sufficient flow with an acceptable pressure drop.
In LIQUID PHASE application both Granular & powered Carbon can be used .
DUE to SUPERIOR ADSORPTION HIGH DENSITY, LOW ATTRITION LOSS, use of Granules has resuited in increased service life, greater filter efficiency, fewer regeneration cycles & economy on Hardware costs.
Activated Carbon Granuces made from coconut shell charcoal is used when a single product or grade is being continuously treated in large quantities. Normally Granular Carbon can be regenerated which involves washing or burining off the impurities & restoring the pore structure.
SIEVE SIZE ANY STANDARED SIEVE SIZE TO SUIT CUSTOMERS REQUIREMENT .
APPLICATION OF GRANULAR ACTIVATED CARBON
odine No. mg / gm. Min |
500 |
700 |
800 |
900 |
1000 |
Ash Max % |
3.5 |
3.5 |
3.5 |
3.5 |
3.5 |
Moisture Max % |
4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
Apparent Density gm / C. C. Min |
0.65 |
60 |
50 |
46 |
40 |
pH |
7.5 |
7.5 |
7.5 |
7.5 |
7.5 |
pH |
6.75 |
6.75 |
6.75 |
6.75 |
6.75 |
Properties |
|
P – 100 |
P – 150 |
P – 200 |
P – 250 |
P – 280 |
P – 320 |
MB Value |
Mg / g |
100 |
150 |
200 |
250 |
280 |
320 |
KMno4 |
% min |
25 |
25 |
45 |
55 |
60 |
70 |
Ash |
% max |
25 |
15 |
10 |
10 |
10 |
10 |
Iron (ppm) |
Max |
1000 |
1000 |
800 |
800 |
600 |
500 |
Acid Soluble (HCL) |
% max |
10 |
10 |
10 |
10 |
10 |
10 |
Water Soluble |
%max |
5 |
5 |
3 |
2 |
2 |
1 |
L.O.D. |
%max |
10 |
10 |
10 |
10 |
10 |
10 |
CL & SO4 |
Max |
USP |
USP |
USP |
USP |
USP |
USP |
Ph |
|
Alkaline |
Alkaline |
Alkaline |
Alkaline |
Alkaline |
Alkaline |
Particle Size |
|
98% Passes through 100 Mesh |
98% Passes through 100 Mesh |
98% Passes through 100 Mesh |
98% Passes through 100 Mesh |
98% Passes through 100 Mesh |
98% Passes through 100 Mesh |
SPECIFICATION OF ACID WASHED POWDER GRADES
Properties |
|
W – 150 |
W – 200 |
W – 250 |
W – 280 |
W – 320 |
MB Value |
Mg / g |
150 |
200 |
250 |
280 |
320 |
KMno4 |
% min |
25 |
35 |
45 |
55 |
65 |
Ash |
% max |
8 |
5 |
4 |
4 |
3 |
Iron (ppm) |
Max |
300 |
200 |
200 |
150 |
200 |
Acid Soluble (HCL) |
% max |
5 |
3 |
2 |
2 |
1 |
Water Soluble |
%max |
5 |
1 |
1 |
1 |
1 |
L.O.D. |
max |
20 |
10 |
10 |
10 |
8 |
CL & SO4 |
Max |
USP |
USP |
USP |
USP |
USP |
Ph |
|
6.0 to 7.5 |
6.0 to 7.5 |
6.0 to 7.5 |
6.0 to 7.5 |
6.0 to 7.5 |
Particle Size |
|
98% Passes through 100 Mesh |
98% Passes through 100 Mesh |
98% Passes through 100 Mesh |
98% Passes through 100 Mesh |
98% Passes through 100 Mesh |
SPECIFICATION OF GRANULAR GRADES
Properties |
|
G – 500 |
G – 600 |
G – 800 |
G – 900 |
G – 1000 |
Appearance |
|
Black Granular |
Black Granular |
Black Granular |
Black Granular |
Black Granular |
Moisture |
%max |
5 |
5 |
5 |
5 |
5 |
Hardness |
Min |
85 |
85 |
95 |
95 |
95 |
Ph |
|
8 – 11 |
8 – 11 |
8 – 11 |
8 – 11 |
8 – 11 |
Iodine Adsorption |
Min |
500 |
600 |
800 |
900 |
1000 |
Bulk Density |
|
0.55 + 0.1 |
0.55 + 0.1 |
0.55 + 0.1 |
0.55 + 0.1 |
0.55 + 0.1 |
Ash |
%max |
5 |
5 |
5 |
5 |
5 |
Surface Areas |
Min |
600 |
700 |
800 |
1000 |
1100 |
CTC Adsorption |
Min |
25 |
45 |
45 |
60 |
65 |
SIMPLE WATER - DRIVEN OPERATION Water passing through Dosamatic drives a piston & down in a reciprocating motion . THis piston in turn drives a small plunger which sucks up chemicals in each upstroke & delivers it at a uniformly adjustable rate . PROPORTIONATE The chemical uptake is directly volumetrically proportion to the water flow . SAVE ON CHEMICAL USAGE Chemical dosing strats only with the water flow, increases & decreasing when flow decreases. This mean only the required quantity ( p. p.m. ) of chemical is dosed, nothing more & nothing less. EASY TO ADJUST / SET A micrometer type internal cylinder can be rotated through 10 turns to set the precise dosing rate even while the pump is in use . EASY TO USE Dosamatic is compact, portable & self priming. Since dosing arrangement is separate from chemical storage, solution tank size can be chosen at will. Also preparation / dilution of chemical solution can be done in the same tank . EASY TO SERVICE Any component of Dosamatic can be opened, inspected & replaced / changed in minutes without tools. A free spares kit comes attached to the pump itself. A user friendly O & M Manual with an exploded view of all parts is provided with each pump for easy dissembly / assembly . CORROSION FREE Use of the latest engineering plastics & rubber seals ensures long corrosion - free life of the pump . USES :- DOMESTIC / COMMERICAL Chlorination of untreated water eg. Borewell, for housing colonies or recirculation water in swimming pools. POULTRY / PIGGERY / FISHERIES Disinfection, vaccination, medication, of water to livestock . AGRICULTURE / HORTICULTURE / FLORICULTURE Fertigation, biocides, acid cleaning, chlorination through drip irrigation systems . INDUSTRIAL Antiscalants, pH correction, oxygen scavengers for boiler feedwater . Biocides, Antiscalants, for cooling water treatments. Alum / Polyelectrolyte & Chlorination / dechlorination prior to filtration equipment . Disinfection, pH correction in effluents treatment plants .
If you are still usingOversized 6 lph pumps and operating them at low frequencies If you are you filing your Chemical Tanks Too Frequently If you are Diluting your Solutions too much Achieve Better Accuracy, Finar Control and Longer Life with New e Dose of 1 lph / 1.5 lph and 3 lph capacity These pumps are ideally suited for RO plants having capacities upto 10 m3 / Hr.and lower. Or places where chemical consumptions is very low.
Technical Specification |
|
Electrical |
230v A.C. 50 Hz |
Suction tubing |
4/6 mm |
Discharge tubing |
4/6 mm |
Dosing rate |
1.5 / 3 / 6 / 10 lph at 4 kg/cm2 |
Strokes / Minute |
max 400 |
Material Of Construction |
|
Pump Head |
Glass filled Noryl |
Diaphragm |
Teflon |
Connectors |
ABS / PP |
Suction tubing |
PVC / PP |
Discharge tubing |
PVC / PP |
The meter is used on sites exposed to rain, dust, and robust handling. Basically, it comes in two parts i.e. Meter & Sensor.
Sensor: It is the sensing element of meter, which senses the conductivity and sends the signal to the meter.
Meter:This is the unit that processes the information received from the sensor and displays the actual conductivity in the line.
TROUBLE |
PROBABLE CAUSE |
ACTION |
DURING COMMISSIONING |
||
Fluctuating |
Sensor not dipped in the line properly |
Loop the outlet tubing such that the tee always remains |
Wrong wiring |
Connect the wires as per drawing |
|
DURING NORMAL SERVICE |
||
Display |
Sensor not dipped in the line .properly |
Loop the outlet tubing such that the tee always remains flooded with water |
Deposition on the sensor |
Remove the sensor and clean it with Polish paper |
|
No Display |
High Voltage |
Check MOV/ FUSE, if it is burnt then replace it with new one |
Frequent |
MOV short |
Replace MOV* |
Mixed bed demineralizer plant embodiesa singlecolumn unitin which strong cation & strong anion resins are intimately mixed together. Water passingthrough the column comes repeatedly in contact with these resins and is thus in effectsubjected almostinfinite numberof demineralizing stages. Demineral water of extreme purity is produced -Purity that can not be produced by any other commercial method. Mixed bed resins are regenerated with acidand alkalibut the ion exchange resin must be separatedbeforethis can be done.
1.1 Quality of water Atypical qualityof mixed bed treated water is as followsConductivityat 25OC
MODEL |
VALVE |
TOP / SIDE |
15 |
¾” ( 20 NB ) |
TOP |
30 |
¾” ( 20 NB ) |
TOP |
60 |
¾” ( 20 NB ) |
TOP |
80 |
¾” ( 20 NB ) |
TOP |
100 |
1 ½” (40 NB) |
TOP |
150 |
1 ½” ( 40NB ) |
TOP |
200 |
1 ½” ( 40NB ) |
TOP |
250 |
1 ½” ( 40NB ) |
SIDE |
Applications of MPV :- Filters
Downflow Pressure Sand Filters.Downflow Multigrade Filters. Downflow Activated Carbon Filter.Downflow Iron Removal Filter.Used as 3 Way / Diverter valve.Suitable for service flow rates upto 80 M3 /hr. and backwash flow rates upto 120 to 130 M3 /hr.Option of fully automatic filters.Special programme available for Fully Automatic Swimming Pool filter application.
MPV :-Softeners
Upflow Softeners.Downflow Softeners.Suitable for service flow rates upto 70 M3 /hr. and resin upto 5, 000 ltr.s Option of Fully Automatic Softener.Option of Fully Automatic one operating one standby scheme.Brine tank automation.Special programme for Domestic Bungalow Softeners.
MPV :-DM Plants
Suitable for 2 bed DM plantSuitable for Mixbed operation.Suitable for Fully Automatic DM plants with advance regeneration features reducing rinse water quantity.We can supply Fully Automatic valve.
We can offer Specialised Automation to your plant requirement
Raw Water is termed Hard Water when it contains dissolved salts of Calcium & Magnesium. Temporary alkaline or carbonates of calcium & magnesium, Permanent non alkaline or noncarbonated hardness is caused by dissolved chlorides, sulphates or nitrates of calcium & magnesium, Softener removes hardness in water. Process The softening process consists of passing raw water containing hardness through a bed of cation resin in sodium form. The hardness ions Ca & Mg are taken up by resin and in exchangesodium ions are relinquishedfrom the resin. Raw water will continue to get softened till the resin gets exhausted. Bringingback the resin to it original form is called regeneration. Softener resin is regenerated by sodium chloride (NaCl) of 10 -15% Concentration. Requirement for Designing Softener: Hardness of Water, Flow Rate/Hour, Single Charge Softening. WE OFFER ALL RANGES OF WATER SOFTNER
Parameters |
Numasoft-15 |
Numasoft-30 |
Numasoft-55 |
Numasoft-80 |
Numasoft-105 |
Numasoft-140 |
Resin Qty. |
15 ltr. |
30 ltr. |
55 ltr. |
80 ltr. |
105 ltr. |
140 ltr. |
OBR @ 100 ppm Hardness |
7.5 M 3 |
15 M 3 |
28 M 3 |
40 M 3 |
55M3 |
80M3 |
Min. Working Pr. |
2.0 Kg / cm² |
2.0 Kg / cm² |
2.0 Kg / cm² |
2.0 Kg / cm² |
2.0 Kg / cm2 |
2.0 Kg / cm2 |
Max. Working Pr. |
4.0 Kg / cm² |
4.0 Kg / cm² |
4.0 Kg / cm² |
4.0 Kg / cm² |
4.0 Kg / cm² |
4.0 Kg / cm² |
Size & Type of Valve |
Top Mounted MPV 3/4” |
Top Mounted MPV 3/4” |
Top Mounted MPV 3/4” |
Top Mounted MPV 3/4” |
Top Mounted MPV 1½” |
Top Mounted MPV 1½” |
Regenrants Qty. |
Na Cl / 2.5 Kg. |
Na Cl / 5 Kg. |
Na Cl / 8.5 Kg. |
Na Cl / 12 Kg. |
Na Cl / 15 Kg. |
Na Cl / 20 Kg. |
Resin |
Thermax Make |
Thermax Make |
Thermax Make |
Thermax Make |
Thermax Make |
Thermax Make |
Vessel |
FRP |
FRP |
FRP |
FRP |
FRP |
FRP |
Max. Flow Rate |
2 M 3 / Hr. |
2 M 3 / Hr. |
2 M 3 / Hr. |
2 M 3 / Hr. |
3 M3 / Hr. |
4 M3 / Hr. |
Vessel Dia. & Height |
205 x 645 mm |
205 x 1120 mm |
265 x 1245 mm |
340 x 1175 mm. |
400 x 1130 |
400 x 1470 mm |
Parameters |
Numasoft-200 |
Numasoft-250 |
Numasoft-330 |
Numasoft-480 |
Numasoft-750 |
Numasoft-1000 |
Resin Qty. |
200 ltr. |
250 ltr. |
330ltr. |
480 ltr. |
750 ltr. |
1000 ltr. |
OBR @ 100 ppm Hardness |
100 M 3 |
125 M 3 |
165 M 3 |
240 M 3 |
375M3 |
500M3 |
Min. Working Pr. |
2.0 Kg / cm² |
2.0 Kg / cm² |
2.0 Kg / cm² |
2.0 Kg / cm² |
2.0 Kg / cm2 |
2.0 Kg / cm2 |
Max. Working Pr. |
4.0 Kg / cm² |
4.0 Kg / cm² |
4.0 Kg / cm² |
4.0 Kg / cm² |
4.0 Kg / cm² |
4.0 Kg / cm² |
Size & Type of Valve |
Top Mounted MPV 1½” |
Side Mounted MPV 1½” |
Side Mounted MPV 1½” |
Side Mounted MPV 1½” |
Side Mounted MPV 1½” |
Side Mounted MPV 1½” |
Regenrants Qty. |
Na Cl / 25 Kg. |
Na Cl / 30 Kg. |
Na Cl / 40 Kg. |
Na Cl / 60 Kg. |
Na Cl / 90 Kg. |
Na Cl / 120 Kg. |
Resin |
Thermax Make |
Thermax Make |
Thermax Make |
Thermax Make |
Thermax Make |
Thermax Make |
Vessel |
FRP |
FRP |
FRP |
FRP |
FRP |
FRP |
Max. Flow Rate |
3 M 3 / Hr. |
3 M 3 / Hr. |
4 M 3 / Hr. |
4 M 3 / Hr. |
5 M3 / Hr. |
5 M3 / Hr. |
Vessel Dia. & Height |
16” x 65” |
16” x 75” |
20” x 69” |
24” x 72” |
30” x 72” |
36” x 72” |