Post Buy Requirement
NS
Ghaziabad, Uttar Pradesh, India
Add Review

Router, Cables & Networking Devices #2440361

Motor Control Centers (MCC)

MCC are offered up to 3200 A operational current at 40 degree Celsius ambient Temperature in single and double front design for 50 kA short Circuit Withstand Capacity and IP: 52 degree of Protection. Form IV of separation as per IS: 8623 is maintained. The switchboards offered are in Fixed and draw-out type configuration with single and double front design. Types of starters include Automatic Star Delta; Direct On-line, Soft Starters, Variable Frequency Drives, Stator Rotor Starters and Autotransformer Starters.

View Complete Details

Power Control Centers (PCC)

Power Control Centers (PCC) are being designed and manufactured up to 6000A rating, suitable for operational Voltage of 415V in a 3 phase 4 wire distribution systems with an insulation voltage upto 660V at an ambient Temperature of 40 degree Celsius. The form of separation as IS 8623 is FORM IV. Short circuit withstand capacity is 50 kA and degree of protection IP: 52, both of these parameters are type tested. The switchboards offered are in Fixed and semi draw-out type configuration with single front design.

View Complete Details

Power Control Centers, Motor Control Centers

Power and motor Control Centers (PMCC) are being designed and manufactured up to 4000A rating, suitable for operational Voltage of 415V in a 3 phase 4 wire distribution systems with an insulation voltage upto 660V at an ambient Temperature of 40 degree Celsius. The form of separation as IS 8623 is FORM IV. Short circuit withstand capacity is 50 kA and degree of protection IP: 52, both of these parameters are type tested. The switchboards offered are in Fixed and semi draw-out type configuration with single front design. Types of starters include Automatic Star Delta; Direct On-line, Soft Starters, Variable Frequency Drives, Stator Rotor Starters and Autotransformer Starters etc.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Router, Cables & Networking Devices from Ghaziabad, Uttar Pradesh by NPR Solutions Pvt Ltd
Post Buy Requirement
NS
Add Review

Our Product / Services

  1. Generators 5 Products available
  2. Wires 5 Products available
  3. Busbar System 4 Products available
  4. Electrodes

    2 Products available
  5. Solar And Renewable Energy Products

    2 Products available
  6. Electric Control Panels

    2 Products available
  7. Storage Drums, Tanks & Containers

    2 Products available
  8. Transformers

    2 Products available
  9. CCTV Camera

    2 Products available
  10. Others Products / Services 20 Products / Services available

Router, Cables & Networking Devices

We offer a complete product range of Motor Control Centers (MCC), Power Control Centers (PCC) and Power Control Centers, Motor Control Centers

Motor Control Centers (MCC)

MCC are offered up to 3200 A operational current at 40 degree Celsius ambient Temperature in single and double front design for 50 kA short Circuit Withstand Capacity and IP: 52 degree of Protection. Form IV of separation as per IS: 8623 is maintained. The switchboards offered are in Fixed and draw-out type configuration with single and double front design. Types of starters include Automatic Star Delta; Direct On-line, Soft Starters, Variable Frequency Drives, Stator Rotor Starters and Autotransformer Starters.

View Complete Details

Power Control Centers (PCC)

Power Control Centers (PCC) are being designed and manufactured up to 6000A rating, suitable for operational Voltage of 415V in a 3 phase 4 wire distribution systems with an insulation voltage upto 660V at an ambient Temperature of 40 degree Celsius. The form of separation as IS 8623 is FORM IV. Short circuit withstand capacity is 50 kA and degree of protection IP: 52, both of these parameters are type tested. The switchboards offered are in Fixed and semi draw-out type configuration with single front design.

View Complete Details

Power Control Centers, Motor Control Centers

Power and motor Control Centers (PMCC) are being designed and manufactured up to 4000A rating, suitable for operational Voltage of 415V in a 3 phase 4 wire distribution systems with an insulation voltage upto 660V at an ambient Temperature of 40 degree Celsius. The form of separation as IS 8623 is FORM IV. Short circuit withstand capacity is 50 kA and degree of protection IP: 52, both of these parameters are type tested. The switchboards offered are in Fixed and semi draw-out type configuration with single front design. Types of starters include Automatic Star Delta; Direct On-line, Soft Starters, Variable Frequency Drives, Stator Rotor Starters and Autotransformer Starters etc.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us