Post Buy Requirement
NP
Add Review

Our Products

  1. Testing Equipment 11 Products available
  2. Tachometers 8 Products available
  3. Measuring Instruments & Equipment 5 Products available
  4. Gas Analyzers 4 Products available
  5. Automotive Body Coach Building 3 Products available
  6. Signs

    2 Products available
  7. Machine And Precision Tools

    2 Products available
  8. Audio Recorders, Mixers & Transmitters

    1 Products available
  9. Puzzles & Educational Games

    1 Products available
  10. Others Products 18 Products available

Gas Analyzers

Our Complete range of products are Gas Analysers 8060, Gas Analysers 8050, Exhaust Gas Analyser 8020, Exhaust Gas Analyser 8040 and Gas Analysers.

Gas Analysers 8060

EXHAUST GAS ANALYSERS 8060 TECHNICAL FEATURES:-
  • Accuracy: Class 0 ISO 3930 OIML R99 ed. 2000, where applicable
  • Zero Setting: automatic (frequency: automatic)
  • Calibration: automatic (frequency: according to the regulation)
  • Gas flow: min. 6 litresminute
  • Condense separator: two stages group with coalescent filters (+ 1 additional filter to protect the pump)
  • Condense discharge: automatic and continuous
  • Flow check: automatic and continuous
  • Net voltage check: automatic and continuous of min voltage.
  • Leak test: automatic (frequency: according to the homologation)
  • Residual HC test: automatic (frequency: according to the homologation)
  • Response time: according to OIML with probe 6 meters length
  • Warming-up: automatic (max. warming-up time: 5 minutes) ENVIRONMENTAL
  • Operating Temp: 5-;.-40C
  • Relative Humidity:
  • View Complete Details

    Gas Analysers 8050

    EXHAUST GAS ANALYSERS 8050Total Gas 8050 and Total Gas module 8060 represent the very last generation of Motorscan' gas analysers, they embody the already well known features of accuracy and reliability of previous products lines improving the technology performances as well as the technical efficiencies.
  • Mains Voltage: 11 0+230 Vac Auto Rancing 1 2 Vdc (on request]
  • Mains Frequency: 50-60 Hz (:t 2%]
  • Power Consuption: 40 W max
  • Dimensions: 500 x 260 x 480 mm
  • Weight: 12 Kg approx
  • Comunication: 4 RS232 communication ports (1 dedicated to terminal 8024) 2CPC connectors for temperature probe and RPM clamp entry -1 0 integrated Keys (only for 805m
  • User interface: Standard: Eight 4-digit 7-segments (height 20mmJ, on two rows (CO, CO2, HC, 02 e RPM, TEMP, NO, M,
  • Optional: hand held teminal (connected to COM2J. with 4x20 alphanumeric display and alphanumeric keyboard with 45 keys.The use of the hand held terminal is compulsory for of. ficial test provided for some of the national standards,
  • Print-out:24 columns standard thermicprinter [only for 8050]
  • View Complete Details

    Exhaust Gas Analyser 8020

    GAS ANAL YSERS8020 . 8040 Eurogas 8020: Infrared exhaust gas analyser(Siemens benchJ-CO- corr. CO -C02-HC-02-NO(Electrochemical or infrared as optional], Complete with Temperature probe, rpminductive clamp and 24 col. printerOptional accessories: hand held terminal 8024, Lambda tester 8046, No sensor 8045, Trolley, Connectable to PC (through software 7101 USBor LPTJ and directly to item 9010, Eurogas Module 8040: Infrared Exhaustgas analyser module to be connected to PCthrough 7101. CO- corr. CO -C02-HC-02-NO(Electrochemical or infrared as optional]Infrared Siemens bencnomplete with temperature probe, rpm inductive clamp, Optional accessories: Connectable to PC (througnsoftware 7101 USB or LPTJ, NO sensor 8045 , trolley, TECHNICAL FEATURES'
  • Precision: Class 1 - OIML R99 ISO 3930 + ed. 2000
  • Zero Setting: Automatic (frequency: automatic!
  • Calibration: Automatic (frequencydepending on the homologation!
  • Gas Sample Intaemin. 6 litresminut!nominal 8 litresminut!
  • Condensate SeparationTwo stage unit wit'coalescence filter, (+ 1 additional filter forpump protectionl
  • Condensate ScavenginAutomatic and continuous
  • Flow ControlAutomatic and continuous
  • Mains Voltage ChedAutomatic and continuoudetection of undervoltafcondition'
  • Leak Test: Automatll(frequency: depending on t1homologatior
  • HC Hangup Test: Automatl(frequency: depending on thomologationss
  • Response Time: complyiwith OIML requirements witn.
  • View Complete Details

    Exhaust Gas Analyser 8040

    EXHAUST GAS ANAL YSERS 8020 . 8040sampling probe length: 6 m
  • Warm Up: Automatic [maximum warm up time: 5 minutes)
  • Mains Voltage: 187 + 264 Vac
  • Mains Frequency: 50 Hz [::t2%)
  • Power Consumption: 150 W max
  • Mains Fuses: 2xT4 A ENVIRONMENTAL OPERATING CONDITIONS:
  • Operating Temperature: 5 + 40C
  • Relative Humidity:
  • View Complete Details
    Tell Us What are you looking for? Will call you back

    Contact Us