Post Buy Requirement
NI
Bangalore, Karnataka, India
Add Review

Our Products

  1. Pumps, Pumping Machines & Parts 16 Products available
  2. Industrial Pump 11 Products available
  3. Industrial Motors 5 Products available
  4. Submersible Pumps 4 Products available
  5. Industrial Valves 3 Products available
  6. DC Motor 3 Products available
  7. Electrical Panels & Distribution Box

    2 Products available
  8. Gearboxes

    2 Products available
  9. Electric Motors & Components

    2 Products available
  10. Electric Motors

    2 Products available
  11. Others Products 21 Products available

Industrial Motors #45543

We offer a complete product range of Crane Duty Cage, Flame Proof Motors, Flameproof Motor With Brake, Crane Duty Brake Motor and Gear Motor With Brake

Crane Duty Cage

  • Output Range(KW) 0.37 to 350
  • Pole 4/6/8/10
  • Frame Size 71 to 400
  • Rotor Type Cage/Wound
  • Duty 220/380/415/550/690
  • CDF 50/60
  • Enclosure IP55
  • S/hr IC411
  • Voltage(V) B3(Foot)/B5(Flange) B35(Foot Cum Flange)
  • Frequency(Hz) F/H
  • Cooling C410/IC411/IC416
  • M/G B3(Foot)/B5(Flange) B35(Foot Cum Flange) B14(Face) B314/(Foot Cum Face)
  • Standards IS:325

New India offers an extensive range of motors suitable for Material Handling & Crane Applications. Motors are offered with Cage & Wound Rotors ranging from 0.37 to 350KW with various speeds depending on polarity 4 / 6 / 8 / 10; Frames: 71 to 400. Motors are offered with voltages of 220 / 380 / 415 / 550 / 690. Considering the critical nature of the application, motors have been built to last and are Robust and Rugged in construction. Motors have high starting and pullout torques and are suited to take on variable and shock loads with high inertia.

SALIENT FEATURES
Robust and rugged design and construction.
High starting and pullout torques.
Energy efficient.
Designed to take variable and shock loads with high intertia.
Special dual coated copper winding wire for inverter driven motors.
Large slipring unit design for wound rotor motors.
Larger terminal box size.
Motors can be offered with double side shaft extension / tapered shaft extension.
View Complete Details

Flame Proof Motors

  • Output Range(KW) 0.09 to 200
  • Pole 4/6/8/10
  • Frame Size 63 to 355
  • Rotor Type Cage/Wound
  • Voltage(V) 220/380/415/550/690
  • Frequency(Hz) 50/60
  • Enclosure IP55
  • Cooling IC411
  • Mounting B3(Foot)/B5(Flange) B35(Foot Cum Flange)
  • Standards IS:325/2148
  • Gas Group 1, 11A, 11B, 11C
  • Hazardous Areas Zone I, Zone II
  • Certifications/Approvals CMRI-Dhanbad, DGMS- Dhanbad CCE-Nagapur, DGFAS & LI-Mumbai BIS, BASEFA, ATEX

New India offers a wide range of low voltage Flameproof Squirrel cage & Slip Ring Electric Motors, ranging from 0.37 kW to 355 kW, for operation in hazardous and hostile environments. Our Flameproof Motors also referred to as Explosion proof are manufactured under the strictest guidelines and are approved by Indian notified body (BIS/DGMS/PESO). We make motors for Gas Groups IIA & IIB routinely in our regular production line. Care is taken to ensure that the operational efficiency and safety aspects are all ensured for best performance. We also offer a complete range of Squirrel Cage Motors for Gas Group IIC atmosphere and are duly tested for the same.
Motors are used in Hazardous areas & industries such as Coal Mines, Petrochemicals & Chemical, Oil Mines & Rigs, Fertilizers, Solvent Extraction Plants, Paints & Varnish Industries, LPG Bottling Plants, Drugs & Pharmaceuticals.

Robust and rugged built with cast Iron/Fabricated body.
Enclosures are hydraulically tested for a pressure of 10kg/cm2.
Special terminal box with cast Iron construction forming a separate flameproof enclosure capable of containing internal explosions.
Terminal box can be provided on sides or top.
View Complete Details

Flameproof Motor With Brake

  • Type Electro Magnetic Fil Safe
  • Supply Voltage 230V AC/190V DC/24V DC
  • Duty S1/S3/S5
  • Torque 4Nm to 500Nm
  • Service Factor 1/213
  • Suitable For AC Motors from 0.18KW to 45KW

New Series of Integral Brake Motors offer better performance, light in weight, aesthetically good and reliable. The Motors are highly engineered to cope up with sudden load increase, longer thermal life, higher altitudes and voltage variations.

Integral Brake Motors are suitable for various industrial application like Textile, MachineTools, Hoists, Cranes, Lifts etc., where instantaneous stopping of the driven equipment isdemanded.
Motors are fitted with Electro Mgnetic Normally on brakes.
The electro-magnetic DC brake is mounted on the non-driving end of the motor. The coolingfan is mounted after the brake for better thermal dissipation and cooling of the brake also.

Motor connection leads and brake coil leads are terminated in a single terminal box foreasy connection, Rectifiers are supplied in loose condition and Manual release is provided

WORKING PRINCIPLE
When power supply is given to the brake coil, the magnetic field produced by it, pulls thearmature plate against spring force making rotor free to rotate.
When power supply to the brake is removed, the armature plate will return to its originalposition instantly and due to axial force developed on the armature plate by the compressionspring will not allow rotor to rotate. This will ensure instant fail safe in case of power failure.
View Complete Details

Crane Duty Brake Motor

  • Type Electro Magnetic Fil Safe
  • Supply Voltage 230V AC/190V DC/24V DC
  • Duty S1/S3/S5
  • Torque 4Nm to 500Nm
  • Service Factor 1/213
  • Suitable For AC Motors from 0.18KW to 45KW

New Series of Integral Brake Motors offer better performance, light in weight, aesthetically good and reliable. The Motors are highly engineered to cope up with sudden load increase, longer thermal life, higher altitudes and voltage variations.

APPLICATIONS
Integral Brake Motors are suitable for various industrial application like Textile, MachineTools, Hoists, Cranes, Lifts etc., where instantaneous stopping of the driven equipment isdemanded.
Motors are fitted with Electro Mgnetic Normally on brakes.
The electro-magnetic DC brake is mounted on the non-driving end of the motor. The coolingfan is mounted after the brake for better thermal dissipation and cooling of the brake also.

Motor connection leads and brake coil leads are terminated in a single terminal box foreasy connection, Rectifiers are supplied in loose condition and Manual release is provided

WORKING PRINCIPLE
When power supply is given to the brake coil, the magnetic field produced by it, pulls thearmature plate against spring force making rotor free to rotate.
When power supply to the brake is removed, the armature plate will return to its originalposition instantly and due to axial force developed on the armature plate by the compressionspring will not allow rotor to rotate. This will ensure instant fail safe in case of power failure.
View Complete Details

Gear Motor With Brake

  • Type Electro Magnetic Fil Safe
  • Supply Voltage 230V AC/190V DC/24V DC
  • Duty S1/S3/S5
  • Torque 4Nm to 500Nm
  • Service Factor 1/213
  • Suitable For AC Motors from 0.18KW to 45KW

New Series of Integral Brake Motors offer better performance, light in weight, aesthetically good and reliable. The Motors are highly engineered to cope up with sudden load increase, longer thermal life, higher altitudes and voltage variations.

APPLICATIONS
Integral Brake Motors are suitable for various industrial application like Textile, MachineTools, Hoists, Cranes, Lifts etc., where instantaneous stopping of the driven equipment isdemanded.
Motors are fitted with Electro Mgnetic Normally on brakes.
The electro-magnetic DC brake is mounted on the non-driving end of the motor. The coolingfan is mounted after the brake for better thermal dissipation and cooling of the brake also.

Motor connection leads and brake coil leads are terminated in a single terminal box foreasy connection, Rectifiers are supplied in loose condition and Manual release is provided

WORKING PRINCIPLE
When power supply is given to the brake coil, the magnetic field produced by it, pulls thearmature plate against spring force making rotor free to rotate.
When power supply to the brake is removed, the armature plate will return to its originalposition instantly and due to axial force developed on the armature plate by the compressionspring will not allow rotor to rotate. This will ensure instant fail safe in case of power failure.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us