1 Products availableAnalyzers And Analytical Instruments
1 Products availableMeasuring Instruments & Equipment
1 Products availableOur product range contains a wide range of Air Quality Monitor, H2S Monitor and CleanRoom Monitor
Model : N-AQ100
Navter Air quality Monitor is a portable desktop and wall mountable instrument that measures CO2, VOC and Dust particle concentration in air.
The instrument displays the real-time value of CO2and VOC concentration in ppm, Dust particle concentration in g/, temperature and relative humidity. It has built-in storage for continuous data logging and Wi-Fi connectivity for easy access of data log.
Quick SpecsThe VOC monitor can be used in a wide variety of applications such as
Features:
The monitor has automatic data logging of STEL (short term exposure limit) values every 15 minutes throughout the operation of the monitor. It has inbuilt storage of 16GB that can store more than a million data records.
The data log stored in the device can be easily accessed from any Wi-Fi enabled device such as smartphone, pc, laptop etc. The data log has auto generated graph of CO2and VOC concentration versus date & time.
The monitor alerts the user of real time changes in CO2and VOC concentration with safety alert message and three different color green, orange and red indicating the range, for easy visual perception.
Monitoring parameter | CO2 | VOC |
Concentration range/ Resolution/ Accuracy | 0.00 to 5000 ppm /1 ppm / ±5% | 0.00 to 50.00ppm / 0.01 ppm / ±10% |
Response Time | <90 sec | <3 sec |
Warm up time | 3 mins | ≤1 min |
Sensor technology | NDIR | PID |
Sensor life | >5 years | >2 years |
Temperature range/ Resolution / Accuracy | 0 to 50°C / (1°C) / (±1°C) | |
Humidity/ Resolution / Accuracy | 10 to 90%RH / 1%RH / ±4%RH | |
Dimension | 14.5 x 9 x 3" (368 x 229 x 76mm) | |
Weight | 4.12Kg | |
Power | 230 V AC, 50/60 Hz | |
Display | 7" HD DISPLAY | |
Memory | In built storage of 1 million readings | |
Continuous Operation | 24 hours | |
Warranty | One year | |
Count Mode | Automatic | |
Display unit | PPM | |
Communication Mode | WIFI | |
Calibration | Factory calibrated valid for 1year |
CO2 Range | VOC range | Color | Alert message |
0 – 1000 ppm | 0 – 10 ppm | Green | Safe |
1000–2000 ppm | 10 – 20 ppm | Orange | Risky |
2000–5000 ppm | 20 – 50 ppm | Red | Danger |
SenseAir HS Monitor is a portable desktop and wall mountable instrument that measures HS concentration in air.The instrument displays the real-time value of HS concentration in ppm, temperature and relative humidity. It has built-in storage for continuous data logging and Wi-Fi connectivity for easy access of data log.
Quick SpecsThe HS monitor can be used in a wide variety of applications such as
Features:
The HS monitor has automatic data logging of STEL (short term exposure limit) values every 15 minutes throughout the operation of the monitor. It has inbuilt storage of 16GB that can store more than a million data records.
The data log stored in the device can be easily accessed from any Wi-Fi enabled device such as smartphone, pc, laptop etc. The data log has auto generated graph of HS concentration versus data & time.
The VOC monitor alerts the user of real time changes in VOC concentration with safety alert message and three different color green, orange and red indicating the range, for easy visual perception.
The safety alert message is displayed as safe and the display color is green when the VOC concentration is in the range of 0.0 ppm to 10 ppm, the display color and safety alert message changes automatically with change in VOC concentration.
VOC Range | Color | Alert message |
0–10 ppm | Green | Safe |
10–20 ppm | Orange | Risky |
20–50 ppm | Red | Danger |
Navter's clean room monitor is a portable desktop and wall mountable instrument that measures dust particle concentration in air.The instrument displays the real-time value of dust particle concentration in g/m, temperature and relative humidity. It has built-in storage for continuous data logging and Wi-Fi connectivity for easy access of data log.
Features:
The clean room monitor has automatic data logging of STEL (short term exposure limit) values every 15 minutes throughout the operation of the monitor. It has inbuilt storage of 16GB that can store more than a million data records.
The data log stored in the device can be easily accessed from any Wi-Fi enabled device such as smartphone, pc, laptop etc. The data log has auto generated graph of dust particle concentration versus date & time.
The clean room monitor alerts the user of real time changes in dust particle concentration with safety alert message and three different colors green, orange and red indicating the range, for easy visual perception.The safety alert message is displayed as safe and the display color is green when the dust particle concentration is in the range of 0 50 g/, the display color and safety alert message changes automatically with change in dust particle concentration.
Particle concentration | Color | Alert message |
0 – 50 μg/ | Green | Safe |
50 - 200 μg/ | Orange | Risky |
200 – 1000 μg/ | Red | Danger |