Application : Sensitivity Calibration, Weld Testing, UT Calibration
Solvclean’s BMS 300 - A high precision cleaning multipurpose spray-Lubricates and protects High penetrative power enables it to loosen rust-metal bond of various rusted metal parts Eliminates oil and grease, dirt, grime etc. from different surfaces Stops squeakmore...
Feature : Power Range : 0 to 100kW,Stability V, I : < 0.01 %FS / 2 min, P : < 0.02 %FS / 2 min Etc.
Calibration of AC Volt, Amp, Watt, Var, Frequency, Powerfactor, Phase angle and Energy Meters Calibration of Voltage, Current, Active & Reactive Power, Frequency, Powerfactor, Phase angle and Energy Transducers.more...
4 - 20mA (1KΩ Load, 24V Loop Supply) with1mA Resolution 0 -100.00mV, 0-1.0000V, 0-12.000V K, J, E & T Thermocouples (°C and °F) Frequency : 1-62500 Hz DC Current Basic Accuracy : 0.025% Easy Key Pad Number Operation Easy Step and Auto Ramp Functions 0-20mA & 0-24mA Selectable more...
Stability DC : < 0.01 %FS / 2 min, AC : < 0.03 %FS / 2 min
Ripple : < 0.1 %
Power Supply : 230 VAC, 50 (60) Hz
Calibration of AC Volt, Amp, Frequency Meters, Calibration of DC Volt, Amp Meters, Calibration of Resistance Meters, Insulation Testers, Step adjustment of Output Signal : 10 %FS, 1 %FS, 0.1 %FS, 0.05 %FSmore...
9V Eveready Type 216 or Equivalent & External Battery Pack (6 x 1.5 V AA Batteries), 4 and 5 Digits with Annunciator, Operating Environment :- 0 ºC to 50 ºC (32 to 122 ºF), RH < 85%.more...
Range from -35°C to 650°C Resolution: 0.1°C / 0.01°C Stability: up to 0.03°C Our easy to transport and sturdy calibrators with laboratory accuracy for all areas of application In test bays and development laboratories, temperature sensors have to be tested, adjusted or recalmore...
INTRODUCTION The SIKA UC mAV is a hand-held process calibrator (conforming toEC standards). It is more particularly intended for calibration and maintenance. It can measure and generate electrical quantities either on site or in the laboratory. It fulfils voltage and current memore...
Features : -100 ~ 155 Degree C. Calibration can using Stirling refrigerator KT-H503 -100 Degree C. ~ 50 Degree C, Adoption of heat equalization block greatly shortens lifting time
SIXSENSE Offers mV / mA calibrator for calibrating any type of thermocouple / mA inputs . Product is suitable for each and every Process industry like steel , plastic, jewellery , pharma etc . Product is very handy and tested for mA load also. It is operated on 9V (2 Nos) batterymore...
Radix Calibrators offer several functions. Operating in measuresource mode, these instruments can handle RTD, mA, mV, thermocouple (TC) and ohms signals amongst others. They can also simulate a 4-20 mA and 24 V loop supply to calibrate other instruments. MICROCAL is lightweight amore...
BRAND : PACE ENGG. GRAPHICAL DISPLAY. MICROCONTROLLER BASED. LOOP POWER SUPPLY FOR TRANSMITTERS. SIMULATION AND MEASUREMENT OF RTD, THERMOCOUPLE, mA, mV OR V, OHMS. SYNQ FACILITY IN mA MODE. more...
Fully automatic calibration accomplished by a smooth noiseless motor driven standard weight inside the balance eliminating weight maintenance. Accurately machined stainless steel standard weight is used for the purpose. Any tolerance in the weight machining is corrected through smore...
UT Calibration Blocks or ultrasonic calibration blocks are widely used in the calibration process. These UT Calibration Blocks are made using ultrasonically tested materials and appreciated for attributes like sturdy construction, corrosion resistance, excellent finish, etc. We pmore...
Fully automatic calibration accomplished by a smooth noiseless motor driven standard weight inside the balance eliminating weight maintenance. Accurately machined stainless steel standard weight is used for the purpose. Any tolerance in the weight machining is corrected through smore...
Fully automatic calibration accomplished by a smooth noiseless motor driven standard weight inside the balance eliminating weight maintenance. Accurately machined stainless steel standard weight is used for the purpose. Any tolerance in the weight machining is corrected through smore...
Fully automatic calibration accomplished by a smooth noiseless motor driven standard weight inside the balance eliminating weight maintenance. Accurately machined stainless steel standard weight is used for the purpose. Any tolerance in the weight machining is corrected through smore...
SANSEL Model TCAL 1503 series of Dry well Temperature calibrator range from -45 to 1200 °C in four model (TCAL 1503 / -45, TCAL 1503 / -35, TCAL 1503 / 300, TCAL 1503 / 600 & TCAL 1503 / 1200) are high precision, better resolution, stability, fast in heating and cooling. more...
SANSEL Model TCAL 1401 / -30 Dry well Temperature calibrator are high performance for industrial atmosphere and covering temperature range from -30* to 100°C. Which are ideally suited onsite calibration of thermocouple, RTDs, Indicator with sensors & 4-20mA signal transmimore...
Feature : Auto Controller, Durable, Heat Resistance
Brand Name : SANSEL
SANSEL Model TCAL 1402 / -20 Miniature calibrator bath are one of the smallest dry well calibrator in the world, which are ideally suited were necessary for fast calibration in process industries to calibrate Thermocouple, RTD, Indicator with sensor & transmitter with sensor.more...