Cable Structure

  • Class 5 tinned copper conductor as per IEC 60228 and IS 8130
  • Polyester taped conductor
  • EPR Insulation
  • Cores twisted
  • CSP outer sheath, black

Standard References

  • IS 9968

Special Features

  • Low bend diameter
  • Highly flexible
  • Excellent electrical properties
  • Good oil resistance
  • Higher temperature and short circuit temperature rating
  • Low temperature performance
  • Improved thermal ageing life

Application Range

  • Industrial machinery and air conditioning systems
  • For general purpose installations in dry or wet environment subjected to low mechanical loads
  • Suitable for areas with oil vapours at room temperature
  • Areas with frequent twists and turns where straight cable laying is not possible

Technical Data

  • TemperatureRange :-30C to +90C
  • NominalVoltage :U0/U 1.1KV
  • TestVoltage :3000 V
  • InsulationResistance :min. 200 Mohm x km
  • Min. BendingRadius :6 x cable dia
  • Short circuittemperature :Upto 250C
  • Flameretardance:As per IEC 60332-1 (self extinguishing)

NOTE :

  • G with GN-YE protective core
  • X without protective core
View Complete Details

PVC Control Cables

Cable Structure
Class 5 bare copper conductor as per IEC 60228 and IS 8130
PVC Insulation
Cores twisted
Polyester tape binded
Almylar and ATC drain wire shield
PVC outer sheath, grey

Standard References

  • BS EN 50288-7

Special Features

  • Low bend diameter
  • Highly flexible
  • Space saving construction
  • Good EMI protection

Application Range

  • Industrial machinery and air conditioning systems
  • For general purpose installations in dry environment subjected to low mechanical loads
  • For installation near electro-magnetic noise near power cables, medium power consuming machinery and appliances
  • Measurement and control
  • Data processing and signaling

Technical Data

  • Temperature Range-15C to +70C
  • Nominal Voltage300/500V
  • Test Voltage1500V
  • Insulation ResistanceMin. 20Mohm-km
  • Min. Bending Radius8 x cable dia
  • Short Circuit TemperatureUpto 160C
  • Flame RetardanceAs per IEC 60332-1
View Complete Details

CY 300 PVC Control Cables

Cable Structure
Class 5 bare copper conductor as per IEC 60228 and IS 8130
PVC Insulation
Cores twisted
Polyester tape binded
Almylar and ATC wire braid screen
PVC outer sheath, grey

Standard References

  • BS EN 50288-7

Special Features

  • Low bend diameter
  • Highly flexible
  • Space saving construction
  • Excellent EMI protection

Application Range

  • Industrial machinery and air conditioning systems
  • For general purpose installations in dry environment subjected to low mechanical loads
  • For installation near electro-magnetic noise near power cables, heavy power consuming machinery and appliances
  • Measurement and control
  • Data processing and signaling

Technical Data

  • Temperature Range-15C to +70C
  • Nominal Voltage300/500V
  • Test Voltage1500V
  • Insulation ResistanceMin. 20Mohm-km
  • Min. Bending Radius8 x cable dia
  • Short Circuit TemperatureUpto 160C
  • Flame RetardanceAs per IEC 60332-1
View Complete Details

EMI Protected PVC Control Cables

Cable Structure
Class 5 bare copper conductor as per IEC 60228 and IS 8130
PVC Insulation
Cores twisted
Polyester tape binded
Fine wire ATC braid
PVC outer sheath, grey

Standard References

  • BS EN 50288-7

Special Features

  • Low bend diameter
  • Highly flexible
  • Space saving construction
  • Excellent EMI protection

Application Range

  • Industrial machinery and air conditioning systems
  • For general purpose installations in dry environment subjected to low mechanical loads
  • For installation near electro-magnetic noise near power cables, heavy power consuming machinery and appliances
  • Measurement and control
  • Data processing and signaling

Technical Data

  • Temperature Range-15C to +70C
  • Nominal Voltage300/500V
  • Test Voltage1500V
  • Insulation ResistanceMin. 20Mohm-km
  • Min. Bending Radius8 x cable dia
  • Short Circuit TemperatureUpto 160C
  • Flame RetardanceAs per IEC 60332-1
View Complete Details

Mechanically Protected PVC Control Cables

Cable Structure
Class 5 bare copper conductor as per IEC 60228 and IS 8130
PVC Insulation
Cores twisted
PVC inner sheath
Fine SS wire braid
PVC outer sheath, grey

Standard References

  • IEC 60502

Special Features

  • Low bend diameter
  • Highly flexible
  • Space saving construction
  • Moderate mechanical protection
  • Corrosion free stainless steel wire braiding used for prolonged strength

Application Range

  • Industrial machinery and air conditioning systems
  • For general purpose installations in dry environment subjected to low mechanical loads
  • High mast lights with low loads

Technical Data

  • Temperature Range-15C to +70C
  • Nominal Voltage0.6/1.0kV
  • Test Voltage3000V
  • Insulation ResistanceMin. 20Mohm-km
  • Min. Bending Radius10 x cable dia
  • Short Circuit TemperatureUpto 160C
  • Flame RetardanceAs per IEC 60332-1
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us