XLPE Insulated Copper Cables

Cable Structure

    • Class : 2Stranded Copper Wire As Per IS:8130
    • Insulated :XLPE As per IS:7098/Pt.1/1988
    • Core Identification:
      • 1 Core :Black / Red / White
      • 2 Core :Black, Red
      • 3 Core :Red, Yellow, Blue
      • 4 Core :Red, Yellow, Blue, Black
      • 5 Core :Red, Yellow, Blue, Black, Grey
      • 6 Core & above :Two adjacent cores (Counting and direction cores) in each layer, Blue & Yellow, remaining cores Grey.
    • Inner Sheath :PVC (Polyvinyl Chloride) ST2 Grade as Per IS:5831
    • Armouring :H.D.Aluminium / G.I. Strip as per IS:3975
    • Outer Sheath :PVC ST2 Grade as per IS:5831

Standard References

  • IS:7098/Pt. 1/1988

Special Features

  • Requires Less Space for Installation
  • Good Thermal Properties than PVC Variant
  • Very Good Physical Strength Than PVC Variant
  • Low Current Leakage than PVC Variant

Variants :

  • FR
  • FRLS

Application Range

  • General And Industrial Application Plant Wiring
  • Under And Ground Cables Which Require High Physical Strength

Technical Data

  • Temperature Range :-15C to +90C
  • Test Voltage :a.c.3 KV (rms)
  • Insulation Resistance :1 x 1014 ohm-CM
  • Min. Bending Radius :12 x OD (OD = Overall Diameter of Cable)
  • Short Circuit Temperature : 250C
  • Voltage Rated :650 / 1100 Volts

  • DIMENSIONAL TABLES, POWER CABLES COPPER / XLPE / STRIP ARMOURED / PVC, TABLE 1 SINGLE CORE COPPER CONDUCTOR XLPE INSULATED & PVC SHEATHED H.D.AL.STRIP ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988

Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
1 x 95.0 19 1.4 21 1150 0.193 430
1 x 120.0 37 1.5 22 1400 0.153 500
1 x 150.0 37 1.7 23 1680 0.124 577
1 x 185.0 37 1.9 25 2040 0.0991 661
1 x 240.0 61 2 27.5 2580 0.0754 781
1 x 300.0 61 2.1 30 3200 0.0601 902
1 x 400.0 61 2.4 34 4200 0.047 1085
1 x 500.0 61 2.6 37.5 5180 0.0366 1253
1 x 630.0 91 2.8 40.5 6425 0.0283 1454
1 x 800.0 91 3.1 51.2 9469 0.0221 945
1 x 1000.0 91 3.3 56.7 11585 0.0176 1063

 

 

  • TWO / THREE / FOUR CORE COPPER CONDUCTOR XLPE INSULATED & PVC SHEATHED G.I. STRIP ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
 Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current rating (Amp)
SQ.MM
      2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core
16 6 0.7 18.5 20 825 1050 1.15   100 100
25 6 0.9 18.5 20.5 23 910 1235 1520 0.727 149 127 127
35 6 0.9 20 23 25 1025 1550 1915 0.524 185 158 158
50 6 1 22.5 25.5 28 1435 2020 2510 0.387 225 192 192
70 12 1.1 25.5 30 33 1910 2720 3430 0.268 289 246 246
95 15 1.1 28 33.5 36.5 2475 3500 4450 0.193 352 298 298
120 15 1.2 30 35.5 40.5 2985 4320 5575 0.153 410 346 346
150 15 1.4 34 40.5 45.5 3600 5280 6710 0.124 381 399 399
185 30 1.6 37 44.5 50.5 4490 6385 8225 0.0991 438 456 456
240 30 1.7 41 49 56.5 5575 8150 10345 0.0754 512 538 538
300 30 1.8 62.06 66.58 74 7541 10519 13626 0.0601 581 480 480
400 30 2 70 75.2 83.74 9666 13595 17672 0.047 662 546 546

NOTE : 2C x 10 & 3C X 10 SQ.MM size -As pER IS :7098 Strip Armouring is not Applicable

 

  • THREE AND HALF CORE XLPE INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
  M N M N     M N  
3.5 X 25 6 6 0.9 0.7 23 1410 0.727 1.15 108
3.5 X 35 6 6 0.9 0.7 25 1725 0.524 1.15 132
3.5 X 50 6 6 1 0.9 28 2325 0.387 0.727 162
3.5 X 70 12 6 1.1 0.9 32 3110 0.268 0.524 198
3.5 X 95 15 6 1.1 1 36 8975 0.193 0.387 240
3.5 X 120 18 12 1.2 1.1 40 4960 0.153 0.268 276
3.5 X 150 18 12 1.4 1.1 44 5870 0.124 0.268 318
3.5 X 185 30 15 1.6 1.1 50 7275 0.0991 0.193 366
3.5 X 240 30 18 1.7 1.2 55 9300 0.0754 0.153 426
3.5 X 300 30 15 1.8 1.4 61 11698 0.0601 0.125 480
3.5 X 400 30 30 2 1.6 67 15005 0.047 0.0991 546

 

 

  • TABLE – 4 MULTICORE COPPER CONDUCTOR XLPE INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
16 X 1.5 1 0.7 19 750 12.1 14
19 X 1.5 1 0.7 20 815 12.1 13
21 X 1.5 1 0.7 21 900 12.1 12
24 X 1.5 1 0.7 23 1000 12.1 12
27 X 1.5 1 0.7 23.5 1050 12.1 11
30 X 1.5 1 0.7 24 1125 12.1 11
33 X 1.5 1 0.7 25 1225 12.1 10
37 X 1.5 1 0.7 26 1325 12.1 10
44 X 1.5 1 0.7 28.5 1500 12.1 9
52 X 1.5 1 0.7 30.5 1700 12.1 9
61 X 1.5 1 0.7 32 1950 12.1 8

 

  • TABLE – 5  MULTICORE COPPER CONDUCTOR XLPE INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
10 X 2.5 1 0.7 19 700 7.41 21
12 X 2.5 1 0.7 19.5 760 7.41 20
14 X 2.5 1 0.7 20 850 7.41 19
16 X 2.5 1 0.7 21.5 820 7.41 18
19 X 2.5 1 0.7 22.5 1025 7.41 17
21 X 2.5 1 0.7 23.5 1140 7.41 16
24 X 2.5 1 0.7 25.5 1250 7.41 16
27 X 2.5 1 0.7 26.5 1350 7.41 16
30 X 2.5 1 0.7 27.5 1550 7.41 14
33 X 2.5 1 0.7 28.5 1630 7.41 14
37 X 2.5 1 0.7 29.5 1710 7.41 13
44 X 2.5 1 0.7 33 2100 7.41 12
52 X 2.5 1 0.7 34.5 2350 7.41 12
61 X 2.5 1 0.7 36 2625 7.41 11
View Complete Details

Pvc Insulated Armoured Cables

  • Temperature Range -15°C to +70°C
  • Test Voltage a.c.3 KV (rms)
  • Insulation Resistance 1 x 1013 ohm-CM
  • Voltage Rated 650 / 1100 Volts
  • Class : 2Stranded Aluminium Wire As Per IS:8130
  • Insulated :PVC (Polyvinyl Chioride) As per IS:5831
  • Core Identification:
    • 1 Core :Black / Red / White
    • 2 Core :Black, Red
    • 3 Core :Black, Yellow, Blue
    • 4 Core :Black, Yellow, Blue & Black
  • Inner Sheath :PVC (Polyvinyl chioride) ST2 Grade as IS:5831
  • Armouring :H.D.Aluminium / G.I. wire as per IS:3975
  • Outer Sheath :PVC ST2 Grade as per IS:5831
  • Special Features

    • Light Weight
    • Better Fire Properties than XLPE Variant
    • Better UV Properties than XLPE Variant

    Variants :

    • FR
    • FRLS
    • 85 Degree

    Application Range

    • General And Industrial Application Plant Wiring
    • Under And Ground Cables Which Require High Physical Strength
View Complete Details

PVC Insulated Aluminium Cables

Cable Structure

    • Class : 2Stranded Aluminium Wire As Per IS:8130
    • Insulated :PVC (Polyvinyl Chioride) As per IS:5831
    • Core Identification:
      • 1 Core :Black / Red / White
      • 2 Core :Black, Red
      • 3 Core :Black, Yellow, Blue
      • 4 Core :Black, Yellow, Blue & Black
    • Inner Sheath :PVC (Polyvinyl chioride) ST2 Grade as IS:5831
    • Armouring :H.D.Aluminium / G.I. wire as per IS:3975
    • Outer Sheath :PVC ST2 Grade as per IS:5831
  • Standard References

    • IS:1554/Pt. 1/1988

    Special Features

    • Light Weight
    • Better Fire Properties than XLPE Variant
    • Better UV Properties than XLPE Variant

    Variants :

    • FR
    • FRLS
    • 85 Degree

    Application Range

    • General And Industrial Application Plant Wiring
    • Under And Ground Cables Which Require High Physical Strength

    Technical Data

    • Temperature Range :-15C to +70C
    • Test Voltage :a.c.3 KV (rms)
    • Insulation Resistance :1 x 1013 ohm-CM
    • Min. Bending Radius :12 x OD (OD = Overall Diameter of Cable)
    • Short Circuit Temperature:/b>160C
    • Voltage Rated :650 / 1100 Volts

  • DIMENSIONAL TABLES,POWER CABLES – ALUMINIUM / PVC / STRIP ARMOURED / PVC, TABLE – 1 SINGLE CORE ALUMINIUM CONDUCTOR PVC INSULATED & PVC SHEATHED H.D.AL.STRIP  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
1 x 95.0 19 1.9 21 1200 0.193 245
1 x 120.0 37 1.9 22 1460 0.153 280
1 x 150.0 37 2.1 24 1770 0.124 320
1 x 185.0 37 2.3 26 2170 0.0991 370
1 x 240.0 61 2.5 29 2740 0.0754 425
1 x 300.0 61 2.7 32 3360 0.0601 475
1 x 400.0 61 3 36 4400 0.047 550
1 x 500.0 61 3.4 40 5450 0.0366 590
1 x 630.0 91 3.9 44 6820 0.0283 660
1 x 800.0 91 3.9 52.8 4974 0.0367 640
1 x 1000.0 91 3.9 57.9 5851 0.0291 720
  • TWO / THREE / FOUR CORE ALUMINIUM CONDUCTOR PVC INSULATED & PVC SHEATHED G.I. STRIP ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
 Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current rating (Amp)
SQ.MM
      2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core
10 6 1     20     910 1.83     52
16 6 1 18 20 23 700 950 1135 1.15 78 66 66
25 6 1.2 20 22 24 955 1270 1560 0.727 105 90 90
35 6 1.2 21.5 25 27 1180 1600 2015 0.524 125 110 110
50 6 1.4 24.5 27 31 1410 2150 2690 0.387 155 135 135
70 12 1.4 28 31 36 1965 2800 3460 0.268 195 165 165
95 15 1.6 31 34 38 2610 3670 4715 0.193 230 200 200
120 18 1.6 33 38 42 3115 4470 5715 0.153 265 230 230
150 18 1.8 37 42 46 3750 5500 6950 0.124 305 265 265
185 30 2 40.5 46 51 4645 6650 5790 0.0991 350 305 305
240 30 2.2 45 52 58 6010 8450 10960 0.0754 410 355 355
300 30 2.4 62.8 67.2 74.9 4061 5288 6646 0.1 365 315 315
400 30 2.6 70.9 76.13 84.7 5002 6587 8322 0.0778 420 375 375

Note : 2C X 11 & 3C X 10 sq.mm size – As per IS :1554 Strip Armouring Is not Applicable

 

  • THREE AND HALF CORE ALUMINIUM CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. WIRE  ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
  M N M N     M N  
3.5 X 25 6 6 1.2 1 25.5 1175 0.727 1.15 90
3.5 X 35 6 6 1.2 1 26.5 1450 0.524 1.15 110
3.5 X 50 6 6 1.4 1.2 29.5 1970 0.387 0.727 135
3.5 X 70 12 6 1.4 1.2 34 750 0.268 0.524 165
3.5 X 95 15 6 1.6 1.4 38 3845 0.193 0.387 200
3.5 X 120 18 12 1.6 1.4 41 4620 0.153 0.268 230
3.5 X 150 18 12 1.8 1.4 45 5490 0.124 0.268 265
3.5 X 185 30 15 2 1.6 50 6895 0.0991 0.193 305
3.5 X 240 30 18 2.2 1.6 56 8965 0.0754 0.153 355
3.5 X 300 30 15 2.4 1.8 64.7 5631 0.1 0.206 315
3.5 X 400 30 30 2.6 2 70.9 6988 0.0778 0.164 375

 

 

  • TABLE – 4 MULTICORE ALUMINIUM CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
12 X 1.5 1 0.8 19 665 12.1 10
14 X 1.5 1 0.8 20 750 12.1 10
16 X 1.5 1 0.8 21 840 12.1 9
19 X 1.5 1 0.8 22 920 12.1 8
21 X 1.5 1 0.8 23.5 1040 12.1 8
24 X 1.5 1 0.8 25 1180 12.1 8
27 X 1.5 1 0.8 26 1240 12.1 7
30 X 1.5 1 0.8 26 1300 12.1 7
33 X 1.5 1 0.8 28 1420 12.1 7
37 X 1.5 1 0.8 28 1535 12.1 7
44 X 1.5 1 0.8 31 1800 12.1 6
52 X 1.5 1 0.8 33 2050 12.1 6
61 X 1.5 1 0.8 35 2300 12.1 6

 

 

  • TABLE – 5 MULTICORE ALUMINIUM CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
10 X 2.5 1 0.9 21 810 7.41 15
12 X 2.5 1 0.9 22 890 7.41 14
14 X 2.5 1 0.9 23 1000 7.41 13
16 X 2.5 1 0.9 24 1083 7.41 13
19 X 2.5 1 0.9 25 1325 7.41 12
21 X 2.5 1 0.9 26 1380 7.41 11
24 X 2.5 1 0.9 28.5 1520 7.41 11
27 X 2.5 1 0.9 29 1665 7.41 10
30 X 2.5 1 0.9 30 1795 7.41 10
33 X 2.5 1 0.9 31.5 1890 7.41 10
37 X 2.5 1 0.9 34 2105 7.41 10
44 X 2.5 1 0.9 35.5 2460 7.41 9
52 X 2.5 1 0.9 38.5 3795 7.41 8
61 X 2.5 1 0.9 40.5 3170 7.41 8

 

View Complete Details

Xlpe Insulated Armoured Cables

  • Temperature Range -15°C to +90°C
  • Test Voltage a.c.3 KV (rms)
  • Insulation Resistance 1 x 1014 ohm-CM
  • Class : 2Stranded Copper Wire As Per IS:8130
  • Insulated :XLPE As per IS:7098/Pt.1/1988
  • Core Identification:
    • 1 Core :Black / Red / White
    • 2 Core :Black, Red
    • 3 Core :Red, Yellow, Blue
    • 4 Core :Red, Yellow, Blue, Black
    • 5 Core :Red, Yellow, Blue, Black, Grey
    • 6 Core & above :Two adjacent cores (Counting and direction cores) in each layer, Blue & Yellow, remaining cores Grey.
  • Inner Sheath :PVC (Polyvinyl Chloride) ST2 Grade as Per IS:5831
  • Outer Sheath :PVC (Polyvinyl Chloride) ST2 Grade as per IS:5831
  • Special Features :

    • Requires Less Space for Installation
    • Good Thermal Properties than PVC Variant
    • Very Good Physical Strength Than PVC Variant
    • Low Current Leakage than PVC Variant

    Variants :

    • FR
    • FRLS

    Application Range

    • General And Industrial Application Plant Wiring
    • Over Group Cables
View Complete Details

PVC Insulated Copper Cables

Cable Structure

    • Class : 2Stranded Copper Wire As Per IS:8130
    • Insulated :PVC (Polyvinyl Chioride) type A or C As per IS:5831
    • Core Identification:
      • 1 Core :Black / Red / White
      • 2 Core :Black, Red
      • 3 Core :Red, Yellow, Blue
      • 4 Core :Red, Yellow, Blue, Black
      • 5 Core :Red, Yellow, Blue, Black, Grey
      • 6 Core & Above :Two adjacent cores(Counting And direction cores) in each Layer, Blue & Yellow, remaining cores Grey.
    • Inner Sheath :PVC (Polyvinyl chioride) ST1 or ST2 Grade as Per IS:5831
    • Armouring :H.D.Aluminium / G.I. wire as per IS:3975
    • Outer Sheath :PVC (Polyvinyl chioride) ST1 or ST2 Grade as per IS:5831

Standard References

  • IS:1554/Pt. 1/1988

Special Features

  • Very High Physical Strength
  • Requires Less Space for Installation
  • Better Fire Properties than XLPE Variant
  • Better UV Properties than XLPE Variant

Variants :

  • FR
  • FRLS
  • HR-85 Degree

Application Range

  • General And Industrial Application Plant Wiring
  • Under And Ground Cables Which Require High Physical Strength

Technical Data

  • Temperature Range :-15C to +70C
  • Test Voltage :a.c.3 KV (rms)
  • Insulation Resistance :1 x 1013 ohm-CM
  • Min. Bending Radius :12 x OD (OD = Overall Diameter of Cable)
  • Short Circuit Temperature:160C
  • Voltage Rated :650 / 1100 Volts

  • DIMENSIONAL TABLES, POWER CABLES COPPER / PVC / STRIP ARMOURED / PVC, TABLE 1 SINGLE CORE COPPER CONDUCTOR PVC INSULATED & PVC SHEATHED H.D.AL.STRIP ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988

Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
1 x 95.0 19 1.9 21 1200 0.193 245
1 x 120.0 37 1.9 22 1460 0.153 280
1 x 150.0 37 2.1 24 1770 0.124 320
1 x 185.0 37 2.3 26 2170 0.0991 370
1 x 240.0 61 2.5 29 2740 0.0754 425
1 x 300.0 61 2.7 32 3360 0.0601 475
1 x 400.0 61 3 36 4400 0.047 550
1 x 500.0 61 3.4 40 5450 0.0366 590
1 x 630.0 91 3.9 44 6820 0.0283 660
1 x 800.0 91 3.1 53.4 10103 0.0221 945
1 x 1000.0 91 3.3 58.9 12293 0.0176 1063

 

 

  • TWO / THREE / FOUR CORE COPPER CONDUCTOR PVC INSULATED & PVC SHEATHED G.I. STRIP ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
 Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current rating (Amp)
SQ.MM
      2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core
10 6 1 20     910 1.83     52
16 6 1 18 20 23 700 950 1135 1.15 78 66 66
25 6 1.2 20 22 24 955 1270 1560 0.727 105 90 90
35 6 1.2 21.5 25 27 1180 1600 2015 0.524 125 110 110
50 6 1.4 24.5 27 31 1410 2150 2690 0.387 155 135 135
70 12 1.4 28 31 36 1965 2800 3460 0.268 195 165 165
95 15 1.6 31 34 38 2610 3670 4715 0.193 230 200 200
120 18 1.6 33 38 42 3115 4470 5715 0.153 265 230 230
150 18 1.8 37 42 46 3750 5500 6950 0.124 305 265 265
185 30 2 40.5 46 51 4645 6650 5790 0.0991 350 305 305
240 30 2.2 45 52 58 6010 8450 10960 0.0754 410 355 355
300 30 1.8 66.76 71.28 78.7 9890 13055 16456 0.0601 581 480 480
400 30 2 74.8 79.9 88.4 12348 16489 20904 0.047 662 546 546

 

 

  • THREE AND HALF CORE COPPER CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. WIRE  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
  M N M N     M N  
3.5 X 25 6 6 1.2 1 25.5 1175 0.727 1.15 90
3.5 X 35 6 6 1.2 1 25 1450 0.524 1.15 110
3.5 X 50 6 6 1.4 1.2 29 1970 0.387 0.727 135
3.5 X 70 12 6 1.4 1.2 33 2750 0.268 0.524 165
3.5 X 95 15 6 1.6 1.4 36.5 3845 0.193 0.387 200
3.5 X 120 18 12 1.6 1.4 39 4620 0.153 0.268 230
3.5 X 150 18 12 1.8 1.4 42.5 5490 0.124 0.268 265
3.5 X 185 30 15 2 1.6 47 6895 0.0991 0.193 305
3.5 X 240 34 18 2.2 1.6 54 8965 0.0754 0.153 355
3.5 X 300 30 15 1.8 1.4 65.7 14003 0.0601 0.125 480
3.5 X 400 30 30 2 1.6 70.9 17526 0.047 0.0991 546

 

 

  • TABLE – 4 MULTICORE COPPER CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
12 X 1.5 1 0.8 19 665 12.1 10
14 X 1.5 1 0.8 20 750 12.1 10
16 X 1.5 1 0.8 21 840 12.1 9
19 X 1.5 1 0.8 22 920 12.1 8
21 X 1.5 1 0.8 23.5 1040 12.1 8
24 X 1.5 1 0.8 25 1180 12.1 8
27 X 1.5 1 0.8 26 1240 12.1 7
30 X 1.5 1 0.8 26 1300 12.1 7
33 X 1.5 1 0.8 28 1420 12.1 7
37 X 1.5 1 0.8 28 1535 12.1 7
44 X 1.5 1 0.8 31 1800 12.1 6
52 X 1.5 1 0.8 33 2050 12.1 6
61 X 1.5 1 0.8 35 2300 12.1 6

 

 

  • TABLE – 5  MULTICORE COPPER CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
10 X 2.5 1 0.9 21 810 7.41 15
12 X 2.5 1 0.9 22 890 7.41 14
14 X 2.5 1 0.9 23 1000 7.41 13
16 X 2.5 1 0.9 24 1083 7.41 13
19 X 2.5 1 0.9 25 1325 7.41 12
21 X 2.5 1 0.9 26 1380 7.41 11
24 X 2.5 1 0.9 28.5 1520 7.41 11
27 X 2.5 1 0.9 29 1665 7.41 10
30 X 2.5 1 0.9 30 1795 7.41 10
33 X 2.5 1 0.9 31.5 1890 7.41 10
37 X 2.5 1 0.9 34 2105 7.41 10
44 X 2.5 1 0.9 35.5 2460 7.41 9
52 X 2.5 1 0.9 38.5 3795 7.41 8
61 X 2.5 1 0.9 40.5 3170 7.41 8
View Complete Details

XLPE Insulated Aluminium Cables

Cable Structure

    • Class : 2Stranded Aluminium Wire As Per IS:8130
    • Insulated :XLPE AS Per IS:7098
    • Core Identification :
      • 1 Core :Black / Red / White
      • 2 Core :Black, Red
      • 3 Core :Black, Yellow, Blue
      • 4 Core :Black, Yellow, Blue & Black
    • Inner Sheath :PVC (Polyvinyl chioride) ST2 Grade as IS:5831
    • Armouring :H.D.Aluminium / G.I. wire as per IS:3975
    • Outer Sheath :PVC ST2 Grade as per IS:5831
  • Standard References

    • IS:7098/Pt. 1/1988

    Special Features

    • Good Thermal Properties Than PVC Variant
    • Light Weight
    • Good Strength than PVC variant
    • Low Current Leakage Than PVC Variant

    Variants :

    • FR
    • FRLS

    Application Range

    • General And Industrial Application Plant Wiring
    • Under And Ground Cables Which Require High Physical Strength

    Technical Data

    • Temperature Range :-15C to +90C
    • Test Voltage :a.c.3 KV (rms)
    • Insulation Resistance :1 x 1014 ohm-CM
    • Min. Bending Radius :12 x OD (OD = Overall Diameter of Cable)
    • Short Circuit Temperature:250C
    • Voltage Rated :650 / 1100 Volts

    • DIMENSIONAL TABLES, POWER CABLES-ALUMINIUM / XLPE/ STRIP ARMOURED / PVCTABLE 1 SINGLE CORE ALUMINIUM CONDUCTOR XLPE INSULATED & PVC SHEATHED H.D.AL.STRIP ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988

Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
1 x 95.0 19 1.4 21 560 0.32 230
1 x 120.0 37 1.5 22 660 0.253 268
1 x 150.0 37 1.7 23 750 0.206 309
1 x 185.0 37 1.9 25 900 0.164 360
1 x 240.0 61 2 27.5 1100 0.125 433
1 x 300.0 61 2.1 30 1350 0.1 501
1 x 400.0 61 2.4 34 1725 0.0778 596
1 x 500.0 61 2.6 37.5 2090 0.0605 693
1 x 630.0 91 2.8 40.5 2525 0.0469 814
1 x 800.0 91 3.1 51.2 4519 0.0367 890
1 x 1000.0 91 3.3 56.7 5398 0.0291 1050

 

 

  • TWO / THREE / FOUR CORE ALUMINIUM CONDUCTOR XLPE INSULATED & PVC SHEATHED G.I. STRIP ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
 Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current rating (Amp)
SQ.MM
      2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core
16 6 0.7 18.5 20 530 715 1.91   70 70
25 6 0.9 18.5 20.5 23 600 770 940 1.2 98 96 96
35 6 0.9 20 23 25 690 900 1050 0.868 124 117 117
50 6 1 22.5 25.5 28 820 1100 1280 0.641 156 142 142
70 12 1.1 25.5 30 33 1050 1425 1700 0.443 188 179 179
95 15 1.1 28 33.5 36.5 1300 1735 2100 0.32 231 221 221
120 15 1.2 30.5 35.5 40.5 1500 2050 2600 0.253 262 257 257
150 15 1.4 34 40.5 45.5 1750 2100 3000 0.206 300 292 292
185 30 1.6 37 44.5 50.5 2200 2500 3650 0.164 344 337 337
240 30 1.7 41 49 56.5 2600 3700 4700 0.125 406 399 399
300 30 1.8 62.06 66.58 74 3829 4950 6201 0.1 440 430 430
400 30 2 70 75.2 83.74 4717 6170 7772 0.0778 500 490 490

NOTE : 2C X 16 SQ.MM Size – As Per IS : 7098 Strip Armouring is not Applicale

 

  • THREE AND HALF CORE ALUMINIUM CONDUCTOR XLPE INSULATED & PVC SHEATHER G.I.STRIP  ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
  M N M N     M N  
3.5 X 25 6 6 0.9 0.7 23 850 1.2 1.91 96
3.5 X 35 6 6 0.9 0.7 25 980 0.868 1.91 117
3.5 X 50 6 6 1 0.9 28 1240 0.641 1.2 142
3.5 X 70 12 6 1.1 0.9 32 1600 0.443 0.868 179
3.5 X 95 15 6 1.1 1 36 1900 0.32 0.641 221
3.5 X 120 15 12 1.2 1.1 39 2300 0.253 0.868 257
3.5 X 150 15 12 1.4 1.1 42 2650 0.206 0.868 292
3.5 X 185 30 15 1.6 1.1 47.5 3250 0.164 0.32 337
3.5 X 240 30 15 1.7 1.2 53.5 4100 0.125 0.253 399
3.5 X 300 30 15 1.8 1.4 61 5202 0.1 0.206 430
3.5 X 400 30 30 2 1.6 67 6436 0.0778 0.164 490
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Insulated Cable from Alwar, Rajasthan by NANGALWALA AUTO MANUFACTURING PRIVATE LIMITED
Post Buy Requirement

Insulated Cable

We offer a complete product range of XLPE Insulated Copper cables, pvc insulated armoured cables, PVC Insulated Aluminium cables, xlpe insulated armoured cables and PVC Insulated Copper Cables

XLPE Insulated Copper Cables

Cable Structure

    • Class : 2Stranded Copper Wire As Per IS:8130
    • Insulated :XLPE As per IS:7098/Pt.1/1988
    • Core Identification:
      • 1 Core :Black / Red / White
      • 2 Core :Black, Red
      • 3 Core :Red, Yellow, Blue
      • 4 Core :Red, Yellow, Blue, Black
      • 5 Core :Red, Yellow, Blue, Black, Grey
      • 6 Core & above :Two adjacent cores (Counting and direction cores) in each layer, Blue & Yellow, remaining cores Grey.
    • Inner Sheath :PVC (Polyvinyl Chloride) ST2 Grade as Per IS:5831
    • Armouring :H.D.Aluminium / G.I. Strip as per IS:3975
    • Outer Sheath :PVC ST2 Grade as per IS:5831

Standard References

  • IS:7098/Pt. 1/1988

Special Features

  • Requires Less Space for Installation
  • Good Thermal Properties than PVC Variant
  • Very Good Physical Strength Than PVC Variant
  • Low Current Leakage than PVC Variant

Variants :

  • FR
  • FRLS

Application Range

  • General And Industrial Application Plant Wiring
  • Under And Ground Cables Which Require High Physical Strength

Technical Data

  • Temperature Range :-15C to +90C
  • Test Voltage :a.c.3 KV (rms)
  • Insulation Resistance :1 x 1014 ohm-CM
  • Min. Bending Radius :12 x OD (OD = Overall Diameter of Cable)
  • Short Circuit Temperature : 250C
  • Voltage Rated :650 / 1100 Volts

  • DIMENSIONAL TABLES, POWER CABLES COPPER / XLPE / STRIP ARMOURED / PVC, TABLE 1 SINGLE CORE COPPER CONDUCTOR XLPE INSULATED & PVC SHEATHED H.D.AL.STRIP ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988

Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
1 x 95.0 19 1.4 21 1150 0.193 430
1 x 120.0 37 1.5 22 1400 0.153 500
1 x 150.0 37 1.7 23 1680 0.124 577
1 x 185.0 37 1.9 25 2040 0.0991 661
1 x 240.0 61 2 27.5 2580 0.0754 781
1 x 300.0 61 2.1 30 3200 0.0601 902
1 x 400.0 61 2.4 34 4200 0.047 1085
1 x 500.0 61 2.6 37.5 5180 0.0366 1253
1 x 630.0 91 2.8 40.5 6425 0.0283 1454
1 x 800.0 91 3.1 51.2 9469 0.0221 945
1 x 1000.0 91 3.3 56.7 11585 0.0176 1063

 

 

  • TWO / THREE / FOUR CORE COPPER CONDUCTOR XLPE INSULATED & PVC SHEATHED G.I. STRIP ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
 Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current rating (Amp)
SQ.MM
      2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core
16 6 0.7 18.5 20 825 1050 1.15   100 100
25 6 0.9 18.5 20.5 23 910 1235 1520 0.727 149 127 127
35 6 0.9 20 23 25 1025 1550 1915 0.524 185 158 158
50 6 1 22.5 25.5 28 1435 2020 2510 0.387 225 192 192
70 12 1.1 25.5 30 33 1910 2720 3430 0.268 289 246 246
95 15 1.1 28 33.5 36.5 2475 3500 4450 0.193 352 298 298
120 15 1.2 30 35.5 40.5 2985 4320 5575 0.153 410 346 346
150 15 1.4 34 40.5 45.5 3600 5280 6710 0.124 381 399 399
185 30 1.6 37 44.5 50.5 4490 6385 8225 0.0991 438 456 456
240 30 1.7 41 49 56.5 5575 8150 10345 0.0754 512 538 538
300 30 1.8 62.06 66.58 74 7541 10519 13626 0.0601 581 480 480
400 30 2 70 75.2 83.74 9666 13595 17672 0.047 662 546 546

NOTE : 2C x 10 & 3C X 10 SQ.MM size -As pER IS :7098 Strip Armouring is not Applicable

 

  • THREE AND HALF CORE XLPE INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
  M N M N     M N  
3.5 X 25 6 6 0.9 0.7 23 1410 0.727 1.15 108
3.5 X 35 6 6 0.9 0.7 25 1725 0.524 1.15 132
3.5 X 50 6 6 1 0.9 28 2325 0.387 0.727 162
3.5 X 70 12 6 1.1 0.9 32 3110 0.268 0.524 198
3.5 X 95 15 6 1.1 1 36 8975 0.193 0.387 240
3.5 X 120 18 12 1.2 1.1 40 4960 0.153 0.268 276
3.5 X 150 18 12 1.4 1.1 44 5870 0.124 0.268 318
3.5 X 185 30 15 1.6 1.1 50 7275 0.0991 0.193 366
3.5 X 240 30 18 1.7 1.2 55 9300 0.0754 0.153 426
3.5 X 300 30 15 1.8 1.4 61 11698 0.0601 0.125 480
3.5 X 400 30 30 2 1.6 67 15005 0.047 0.0991 546

 

 

  • TABLE – 4 MULTICORE COPPER CONDUCTOR XLPE INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
16 X 1.5 1 0.7 19 750 12.1 14
19 X 1.5 1 0.7 20 815 12.1 13
21 X 1.5 1 0.7 21 900 12.1 12
24 X 1.5 1 0.7 23 1000 12.1 12
27 X 1.5 1 0.7 23.5 1050 12.1 11
30 X 1.5 1 0.7 24 1125 12.1 11
33 X 1.5 1 0.7 25 1225 12.1 10
37 X 1.5 1 0.7 26 1325 12.1 10
44 X 1.5 1 0.7 28.5 1500 12.1 9
52 X 1.5 1 0.7 30.5 1700 12.1 9
61 X 1.5 1 0.7 32 1950 12.1 8

 

  • TABLE – 5  MULTICORE COPPER CONDUCTOR XLPE INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
10 X 2.5 1 0.7 19 700 7.41 21
12 X 2.5 1 0.7 19.5 760 7.41 20
14 X 2.5 1 0.7 20 850 7.41 19
16 X 2.5 1 0.7 21.5 820 7.41 18
19 X 2.5 1 0.7 22.5 1025 7.41 17
21 X 2.5 1 0.7 23.5 1140 7.41 16
24 X 2.5 1 0.7 25.5 1250 7.41 16
27 X 2.5 1 0.7 26.5 1350 7.41 16
30 X 2.5 1 0.7 27.5 1550 7.41 14
33 X 2.5 1 0.7 28.5 1630 7.41 14
37 X 2.5 1 0.7 29.5 1710 7.41 13
44 X 2.5 1 0.7 33 2100 7.41 12
52 X 2.5 1 0.7 34.5 2350 7.41 12
61 X 2.5 1 0.7 36 2625 7.41 11
View Complete Details

Pvc Insulated Armoured Cables

  • Temperature Range -15°C to +70°C
  • Test Voltage a.c.3 KV (rms)
  • Insulation Resistance 1 x 1013 ohm-CM
  • Voltage Rated 650 / 1100 Volts
  • Class : 2Stranded Aluminium Wire As Per IS:8130
  • Insulated :PVC (Polyvinyl Chioride) As per IS:5831
  • Core Identification:
    • 1 Core :Black / Red / White
    • 2 Core :Black, Red
    • 3 Core :Black, Yellow, Blue
    • 4 Core :Black, Yellow, Blue & Black
  • Inner Sheath :PVC (Polyvinyl chioride) ST2 Grade as IS:5831
  • Armouring :H.D.Aluminium / G.I. wire as per IS:3975
  • Outer Sheath :PVC ST2 Grade as per IS:5831
  • Special Features

    • Light Weight
    • Better Fire Properties than XLPE Variant
    • Better UV Properties than XLPE Variant

    Variants :

    • FR
    • FRLS
    • 85 Degree

    Application Range

    • General And Industrial Application Plant Wiring
    • Under And Ground Cables Which Require High Physical Strength
View Complete Details

PVC Insulated Aluminium Cables

Cable Structure

    • Class : 2Stranded Aluminium Wire As Per IS:8130
    • Insulated :PVC (Polyvinyl Chioride) As per IS:5831
    • Core Identification:
      • 1 Core :Black / Red / White
      • 2 Core :Black, Red
      • 3 Core :Black, Yellow, Blue
      • 4 Core :Black, Yellow, Blue & Black
    • Inner Sheath :PVC (Polyvinyl chioride) ST2 Grade as IS:5831
    • Armouring :H.D.Aluminium / G.I. wire as per IS:3975
    • Outer Sheath :PVC ST2 Grade as per IS:5831
  • Standard References

    • IS:1554/Pt. 1/1988

    Special Features

    • Light Weight
    • Better Fire Properties than XLPE Variant
    • Better UV Properties than XLPE Variant

    Variants :

    • FR
    • FRLS
    • 85 Degree

    Application Range

    • General And Industrial Application Plant Wiring
    • Under And Ground Cables Which Require High Physical Strength

    Technical Data

    • Temperature Range :-15C to +70C
    • Test Voltage :a.c.3 KV (rms)
    • Insulation Resistance :1 x 1013 ohm-CM
    • Min. Bending Radius :12 x OD (OD = Overall Diameter of Cable)
    • Short Circuit Temperature:/b>160C
    • Voltage Rated :650 / 1100 Volts

  • DIMENSIONAL TABLES,POWER CABLES – ALUMINIUM / PVC / STRIP ARMOURED / PVC, TABLE – 1 SINGLE CORE ALUMINIUM CONDUCTOR PVC INSULATED & PVC SHEATHED H.D.AL.STRIP  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
1 x 95.0 19 1.9 21 1200 0.193 245
1 x 120.0 37 1.9 22 1460 0.153 280
1 x 150.0 37 2.1 24 1770 0.124 320
1 x 185.0 37 2.3 26 2170 0.0991 370
1 x 240.0 61 2.5 29 2740 0.0754 425
1 x 300.0 61 2.7 32 3360 0.0601 475
1 x 400.0 61 3 36 4400 0.047 550
1 x 500.0 61 3.4 40 5450 0.0366 590
1 x 630.0 91 3.9 44 6820 0.0283 660
1 x 800.0 91 3.9 52.8 4974 0.0367 640
1 x 1000.0 91 3.9 57.9 5851 0.0291 720
  • TWO / THREE / FOUR CORE ALUMINIUM CONDUCTOR PVC INSULATED & PVC SHEATHED G.I. STRIP ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
 Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current rating (Amp)
SQ.MM
      2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core
10 6 1     20     910 1.83     52
16 6 1 18 20 23 700 950 1135 1.15 78 66 66
25 6 1.2 20 22 24 955 1270 1560 0.727 105 90 90
35 6 1.2 21.5 25 27 1180 1600 2015 0.524 125 110 110
50 6 1.4 24.5 27 31 1410 2150 2690 0.387 155 135 135
70 12 1.4 28 31 36 1965 2800 3460 0.268 195 165 165
95 15 1.6 31 34 38 2610 3670 4715 0.193 230 200 200
120 18 1.6 33 38 42 3115 4470 5715 0.153 265 230 230
150 18 1.8 37 42 46 3750 5500 6950 0.124 305 265 265
185 30 2 40.5 46 51 4645 6650 5790 0.0991 350 305 305
240 30 2.2 45 52 58 6010 8450 10960 0.0754 410 355 355
300 30 2.4 62.8 67.2 74.9 4061 5288 6646 0.1 365 315 315
400 30 2.6 70.9 76.13 84.7 5002 6587 8322 0.0778 420 375 375

Note : 2C X 11 & 3C X 10 sq.mm size – As per IS :1554 Strip Armouring Is not Applicable

 

  • THREE AND HALF CORE ALUMINIUM CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. WIRE  ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
  M N M N     M N  
3.5 X 25 6 6 1.2 1 25.5 1175 0.727 1.15 90
3.5 X 35 6 6 1.2 1 26.5 1450 0.524 1.15 110
3.5 X 50 6 6 1.4 1.2 29.5 1970 0.387 0.727 135
3.5 X 70 12 6 1.4 1.2 34 750 0.268 0.524 165
3.5 X 95 15 6 1.6 1.4 38 3845 0.193 0.387 200
3.5 X 120 18 12 1.6 1.4 41 4620 0.153 0.268 230
3.5 X 150 18 12 1.8 1.4 45 5490 0.124 0.268 265
3.5 X 185 30 15 2 1.6 50 6895 0.0991 0.193 305
3.5 X 240 30 18 2.2 1.6 56 8965 0.0754 0.153 355
3.5 X 300 30 15 2.4 1.8 64.7 5631 0.1 0.206 315
3.5 X 400 30 30 2.6 2 70.9 6988 0.0778 0.164 375

 

 

  • TABLE – 4 MULTICORE ALUMINIUM CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
12 X 1.5 1 0.8 19 665 12.1 10
14 X 1.5 1 0.8 20 750 12.1 10
16 X 1.5 1 0.8 21 840 12.1 9
19 X 1.5 1 0.8 22 920 12.1 8
21 X 1.5 1 0.8 23.5 1040 12.1 8
24 X 1.5 1 0.8 25 1180 12.1 8
27 X 1.5 1 0.8 26 1240 12.1 7
30 X 1.5 1 0.8 26 1300 12.1 7
33 X 1.5 1 0.8 28 1420 12.1 7
37 X 1.5 1 0.8 28 1535 12.1 7
44 X 1.5 1 0.8 31 1800 12.1 6
52 X 1.5 1 0.8 33 2050 12.1 6
61 X 1.5 1 0.8 35 2300 12.1 6

 

 

  • TABLE – 5 MULTICORE ALUMINIUM CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
10 X 2.5 1 0.9 21 810 7.41 15
12 X 2.5 1 0.9 22 890 7.41 14
14 X 2.5 1 0.9 23 1000 7.41 13
16 X 2.5 1 0.9 24 1083 7.41 13
19 X 2.5 1 0.9 25 1325 7.41 12
21 X 2.5 1 0.9 26 1380 7.41 11
24 X 2.5 1 0.9 28.5 1520 7.41 11
27 X 2.5 1 0.9 29 1665 7.41 10
30 X 2.5 1 0.9 30 1795 7.41 10
33 X 2.5 1 0.9 31.5 1890 7.41 10
37 X 2.5 1 0.9 34 2105 7.41 10
44 X 2.5 1 0.9 35.5 2460 7.41 9
52 X 2.5 1 0.9 38.5 3795 7.41 8
61 X 2.5 1 0.9 40.5 3170 7.41 8

 

View Complete Details

Xlpe Insulated Armoured Cables

  • Temperature Range -15°C to +90°C
  • Test Voltage a.c.3 KV (rms)
  • Insulation Resistance 1 x 1014 ohm-CM
  • Class : 2Stranded Copper Wire As Per IS:8130
  • Insulated :XLPE As per IS:7098/Pt.1/1988
  • Core Identification:
    • 1 Core :Black / Red / White
    • 2 Core :Black, Red
    • 3 Core :Red, Yellow, Blue
    • 4 Core :Red, Yellow, Blue, Black
    • 5 Core :Red, Yellow, Blue, Black, Grey
    • 6 Core & above :Two adjacent cores (Counting and direction cores) in each layer, Blue & Yellow, remaining cores Grey.
  • Inner Sheath :PVC (Polyvinyl Chloride) ST2 Grade as Per IS:5831
  • Outer Sheath :PVC (Polyvinyl Chloride) ST2 Grade as per IS:5831
  • Special Features :

    • Requires Less Space for Installation
    • Good Thermal Properties than PVC Variant
    • Very Good Physical Strength Than PVC Variant
    • Low Current Leakage than PVC Variant

    Variants :

    • FR
    • FRLS

    Application Range

    • General And Industrial Application Plant Wiring
    • Over Group Cables
View Complete Details

PVC Insulated Copper Cables

Cable Structure

    • Class : 2Stranded Copper Wire As Per IS:8130
    • Insulated :PVC (Polyvinyl Chioride) type A or C As per IS:5831
    • Core Identification:
      • 1 Core :Black / Red / White
      • 2 Core :Black, Red
      • 3 Core :Red, Yellow, Blue
      • 4 Core :Red, Yellow, Blue, Black
      • 5 Core :Red, Yellow, Blue, Black, Grey
      • 6 Core & Above :Two adjacent cores(Counting And direction cores) in each Layer, Blue & Yellow, remaining cores Grey.
    • Inner Sheath :PVC (Polyvinyl chioride) ST1 or ST2 Grade as Per IS:5831
    • Armouring :H.D.Aluminium / G.I. wire as per IS:3975
    • Outer Sheath :PVC (Polyvinyl chioride) ST1 or ST2 Grade as per IS:5831

Standard References

  • IS:1554/Pt. 1/1988

Special Features

  • Very High Physical Strength
  • Requires Less Space for Installation
  • Better Fire Properties than XLPE Variant
  • Better UV Properties than XLPE Variant

Variants :

  • FR
  • FRLS
  • HR-85 Degree

Application Range

  • General And Industrial Application Plant Wiring
  • Under And Ground Cables Which Require High Physical Strength

Technical Data

  • Temperature Range :-15C to +70C
  • Test Voltage :a.c.3 KV (rms)
  • Insulation Resistance :1 x 1013 ohm-CM
  • Min. Bending Radius :12 x OD (OD = Overall Diameter of Cable)
  • Short Circuit Temperature:160C
  • Voltage Rated :650 / 1100 Volts

  • DIMENSIONAL TABLES, POWER CABLES COPPER / PVC / STRIP ARMOURED / PVC, TABLE 1 SINGLE CORE COPPER CONDUCTOR PVC INSULATED & PVC SHEATHED H.D.AL.STRIP ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988

Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
1 x 95.0 19 1.9 21 1200 0.193 245
1 x 120.0 37 1.9 22 1460 0.153 280
1 x 150.0 37 2.1 24 1770 0.124 320
1 x 185.0 37 2.3 26 2170 0.0991 370
1 x 240.0 61 2.5 29 2740 0.0754 425
1 x 300.0 61 2.7 32 3360 0.0601 475
1 x 400.0 61 3 36 4400 0.047 550
1 x 500.0 61 3.4 40 5450 0.0366 590
1 x 630.0 91 3.9 44 6820 0.0283 660
1 x 800.0 91 3.1 53.4 10103 0.0221 945
1 x 1000.0 91 3.3 58.9 12293 0.0176 1063

 

 

  • TWO / THREE / FOUR CORE COPPER CONDUCTOR PVC INSULATED & PVC SHEATHED G.I. STRIP ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
 Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current rating (Amp)
SQ.MM
      2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core
10 6 1 20     910 1.83     52
16 6 1 18 20 23 700 950 1135 1.15 78 66 66
25 6 1.2 20 22 24 955 1270 1560 0.727 105 90 90
35 6 1.2 21.5 25 27 1180 1600 2015 0.524 125 110 110
50 6 1.4 24.5 27 31 1410 2150 2690 0.387 155 135 135
70 12 1.4 28 31 36 1965 2800 3460 0.268 195 165 165
95 15 1.6 31 34 38 2610 3670 4715 0.193 230 200 200
120 18 1.6 33 38 42 3115 4470 5715 0.153 265 230 230
150 18 1.8 37 42 46 3750 5500 6950 0.124 305 265 265
185 30 2 40.5 46 51 4645 6650 5790 0.0991 350 305 305
240 30 2.2 45 52 58 6010 8450 10960 0.0754 410 355 355
300 30 1.8 66.76 71.28 78.7 9890 13055 16456 0.0601 581 480 480
400 30 2 74.8 79.9 88.4 12348 16489 20904 0.047 662 546 546

 

 

  • THREE AND HALF CORE COPPER CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. WIRE  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
  M N M N     M N  
3.5 X 25 6 6 1.2 1 25.5 1175 0.727 1.15 90
3.5 X 35 6 6 1.2 1 25 1450 0.524 1.15 110
3.5 X 50 6 6 1.4 1.2 29 1970 0.387 0.727 135
3.5 X 70 12 6 1.4 1.2 33 2750 0.268 0.524 165
3.5 X 95 15 6 1.6 1.4 36.5 3845 0.193 0.387 200
3.5 X 120 18 12 1.6 1.4 39 4620 0.153 0.268 230
3.5 X 150 18 12 1.8 1.4 42.5 5490 0.124 0.268 265
3.5 X 185 30 15 2 1.6 47 6895 0.0991 0.193 305
3.5 X 240 34 18 2.2 1.6 54 8965 0.0754 0.153 355
3.5 X 300 30 15 1.8 1.4 65.7 14003 0.0601 0.125 480
3.5 X 400 30 30 2 1.6 70.9 17526 0.047 0.0991 546

 

 

  • TABLE – 4 MULTICORE COPPER CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
12 X 1.5 1 0.8 19 665 12.1 10
14 X 1.5 1 0.8 20 750 12.1 10
16 X 1.5 1 0.8 21 840 12.1 9
19 X 1.5 1 0.8 22 920 12.1 8
21 X 1.5 1 0.8 23.5 1040 12.1 8
24 X 1.5 1 0.8 25 1180 12.1 8
27 X 1.5 1 0.8 26 1240 12.1 7
30 X 1.5 1 0.8 26 1300 12.1 7
33 X 1.5 1 0.8 28 1420 12.1 7
37 X 1.5 1 0.8 28 1535 12.1 7
44 X 1.5 1 0.8 31 1800 12.1 6
52 X 1.5 1 0.8 33 2050 12.1 6
61 X 1.5 1 0.8 35 2300 12.1 6

 

 

  • TABLE – 5  MULTICORE COPPER CONDUCTOR PVC INSULATED & PVC SHEATHER G.I. STRIP  ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
10 X 2.5 1 0.9 21 810 7.41 15
12 X 2.5 1 0.9 22 890 7.41 14
14 X 2.5 1 0.9 23 1000 7.41 13
16 X 2.5 1 0.9 24 1083 7.41 13
19 X 2.5 1 0.9 25 1325 7.41 12
21 X 2.5 1 0.9 26 1380 7.41 11
24 X 2.5 1 0.9 28.5 1520 7.41 11
27 X 2.5 1 0.9 29 1665 7.41 10
30 X 2.5 1 0.9 30 1795 7.41 10
33 X 2.5 1 0.9 31.5 1890 7.41 10
37 X 2.5 1 0.9 34 2105 7.41 10
44 X 2.5 1 0.9 35.5 2460 7.41 9
52 X 2.5 1 0.9 38.5 3795 7.41 8
61 X 2.5 1 0.9 40.5 3170 7.41 8
View Complete Details

XLPE Insulated Aluminium Cables

Cable Structure

    • Class : 2Stranded Aluminium Wire As Per IS:8130
    • Insulated :XLPE AS Per IS:7098
    • Core Identification :
      • 1 Core :Black / Red / White
      • 2 Core :Black, Red
      • 3 Core :Black, Yellow, Blue
      • 4 Core :Black, Yellow, Blue & Black
    • Inner Sheath :PVC (Polyvinyl chioride) ST2 Grade as IS:5831
    • Armouring :H.D.Aluminium / G.I. wire as per IS:3975
    • Outer Sheath :PVC ST2 Grade as per IS:5831
  • Standard References

    • IS:7098/Pt. 1/1988

    Special Features

    • Good Thermal Properties Than PVC Variant
    • Light Weight
    • Good Strength than PVC variant
    • Low Current Leakage Than PVC Variant

    Variants :

    • FR
    • FRLS

    Application Range

    • General And Industrial Application Plant Wiring
    • Under And Ground Cables Which Require High Physical Strength

    Technical Data

    • Temperature Range :-15C to +90C
    • Test Voltage :a.c.3 KV (rms)
    • Insulation Resistance :1 x 1014 ohm-CM
    • Min. Bending Radius :12 x OD (OD = Overall Diameter of Cable)
    • Short Circuit Temperature:250C
    • Voltage Rated :650 / 1100 Volts

    • DIMENSIONAL TABLES, POWER CABLES-ALUMINIUM / XLPE/ STRIP ARMOURED / PVCTABLE 1 SINGLE CORE ALUMINIUM CONDUCTOR XLPE INSULATED & PVC SHEATHED H.D.AL.STRIP ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988

Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
1 x 95.0 19 1.4 21 560 0.32 230
1 x 120.0 37 1.5 22 660 0.253 268
1 x 150.0 37 1.7 23 750 0.206 309
1 x 185.0 37 1.9 25 900 0.164 360
1 x 240.0 61 2 27.5 1100 0.125 433
1 x 300.0 61 2.1 30 1350 0.1 501
1 x 400.0 61 2.4 34 1725 0.0778 596
1 x 500.0 61 2.6 37.5 2090 0.0605 693
1 x 630.0 91 2.8 40.5 2525 0.0469 814
1 x 800.0 91 3.1 51.2 4519 0.0367 890
1 x 1000.0 91 3.3 56.7 5398 0.0291 1050

 

 

  • TWO / THREE / FOUR CORE ALUMINIUM CONDUCTOR XLPE INSULATED & PVC SHEATHED G.I. STRIP ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
 Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current rating (Amp)
SQ.MM
      2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core
16 6 0.7 18.5 20 530 715 1.91   70 70
25 6 0.9 18.5 20.5 23 600 770 940 1.2 98 96 96
35 6 0.9 20 23 25 690 900 1050 0.868 124 117 117
50 6 1 22.5 25.5 28 820 1100 1280 0.641 156 142 142
70 12 1.1 25.5 30 33 1050 1425 1700 0.443 188 179 179
95 15 1.1 28 33.5 36.5 1300 1735 2100 0.32 231 221 221
120 15 1.2 30.5 35.5 40.5 1500 2050 2600 0.253 262 257 257
150 15 1.4 34 40.5 45.5 1750 2100 3000 0.206 300 292 292
185 30 1.6 37 44.5 50.5 2200 2500 3650 0.164 344 337 337
240 30 1.7 41 49 56.5 2600 3700 4700 0.125 406 399 399
300 30 1.8 62.06 66.58 74 3829 4950 6201 0.1 440 430 430
400 30 2 70 75.2 83.74 4717 6170 7772 0.0778 500 490 490

NOTE : 2C X 16 SQ.MM Size – As Per IS : 7098 Strip Armouring is not Applicale

 

  • THREE AND HALF CORE ALUMINIUM CONDUCTOR XLPE INSULATED & PVC SHEATHER G.I.STRIP  ARMOURED CABLES ACCORDING TO IS : 7098/PT. 1/1988
Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Nominal Overall Diameter(mm) Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
  M N M N     M N  
3.5 X 25 6 6 0.9 0.7 23 850 1.2 1.91 96
3.5 X 35 6 6 0.9 0.7 25 980 0.868 1.91 117
3.5 X 50 6 6 1 0.9 28 1240 0.641 1.2 142
3.5 X 70 12 6 1.1 0.9 32 1600 0.443 0.868 179
3.5 X 95 15 6 1.1 1 36 1900 0.32 0.641 221
3.5 X 120 15 12 1.2 1.1 39 2300 0.253 0.868 257
3.5 X 150 15 12 1.4 1.1 42 2650 0.206 0.868 292
3.5 X 185 30 15 1.6 1.1 47.5 3250 0.164 0.32 337
3.5 X 240 30 15 1.7 1.2 53.5 4100 0.125 0.253 399
3.5 X 300 30 15 1.8 1.4 61 5202 0.1 0.206 430
3.5 X 400 30 30 2 1.6 67 6436 0.0778 0.164 490