Post Buy Requirement
NS
Delhi, India
Add Review

Our Products

  1. Measuring Instruments & Equipment 24 Products available
  2. Spectrophotometers 7 Products available
  3. Biochemistry Analyzer 4 Products available
  4. Surgical Equipment & Supplies 3 Products available
  5. Microscope 3 Products available
  6. Laboratory Equipments 3 Products available
  7. Photo Meters

    2 Products available
  8. Lab Instrument

    1 Products available
  9. Potentiometer

    1 Products available
  10. Others Products 28 Products available

Spectrophotometers #3736875

Our product range contains a wide range of spectro photometer, Spectrophotometer, Digital Spectrophotometer, MICROPROCESSOR VISIBLE SPECTROPHOTOMETER and UV-VIS Spectrophotometer

Spectro Photometer

Visible spectrophotometer NSP 365 having range 340 to 960nm. Dual LED display for %T, ABS & Concentration. Resolution 1nm.Mains operated.Complete with standard accessories.
View Complete Details

Spectrophotometer

Digital Spectrophotometer NSP 365: display: Dual LED Display.Measuring Parameter 3[ Absorbance: 0 to 1999, %Transmission: 0 to 100%, Concentration: 0 to 1999.Detector: silicon photo diode.Grating: 600lines/mm.Light source: Tungsten halogen lamp.Spectral band width: 10mm.Wave length resolution: 1nm. wavelength accuracy: 1nm.Mains: 230VAC.Complete with standard accessories.

Additional Information:

Payment Terms : T/T

Packaging Details : Standard Corrugated Box.

Delivery Time : 1 week

View Complete Details

Digital Spectrophotometer

  • Range 340 - 960 nm
  • Resolution 0.1 %T, 0.001 Abs
  • Output 0 to 100%
  • Weight 8.0kgs (approx).

Technical Specifications

Range:340 - 960 nm.Resolution:0.1 %T, 0.001 Abs.Output :% T:0to 100%.Abs.: 0 to 1.999.Conc. : 0 to 1999.Detector: Silicon Photodiode.Light Source: 6V, 1 Amp, Tungsten Halogen Lamp.Monochromator: 600 Lines/mm grating.Path Length: 10mm.

SpectralBandwidth:10 nm.Wavelength resolution:1nmon digital display, Wavelength accuracy:

1 nm.Repeatability: 1 nm.Display:3 1/2 digit LED display.Operating Temp.: 5to 45 C.Power: 230V 10%AC 50 Hz.Size(L x B x H): 460 x320 x 185 mm.Weight: 8.0kgs (approx).Accessories:Test tubes, Dust Cover, Instruction manual

View Complete Details

MICROPROCESSOR VISIBLE SPECTROPHOTOMETER

  • Weight 13.5 Kgs
  • Wavelength Range 325-1000nm
  • Accuracy < 2nm
  • Repeatability < 1nm
  • Dimensions 56 x 48x 29 cms

CHARACTERISTICS

The monochromator with a holographic flashing grating is used. It has the advantage of high wavelength precision, good monochromaticity and low stray light. Automatic switching of tungsten halogen lamp and deuterium lamp. A sample compartment for 0.5cm-10cm cells. Computer control system, precise automatic T/A changeover. Automatic zero and full scale adjustment. Direct concentration read-out and concentration factor setting function. Equipped with RS232 port. Printer can be connected and data can be sent to PC by special software.

SPECTIFICATIONS

WavelengthRange: 325-1000nm, Wavelength Accuracy: < 2nm, Wavelength Repeatability: < 1nm

Transmittance Accuracy:+0.5%, Transmittance Repeatability: < 0.2%, Spectrum Bandwidth:5nmStray Light: < 0.5% (at 360nm, Nano2), Light Current Drift:0.5% / 3 min, Dark Current Drift: 0.2% / 3 min

Cell Holder: 10mm, Dimensions: 56 x 48x 29 cms, Net Weight: 13.5 Kgs, Gross Weight: 27 Kgs

STANDARD CONFIGURATION:Main Instrument : 1 Unit, Operational Manual : 1 Pc, Glass Cell 10mm : 4 Pcs, Power Cable : 1 Pc, Fuse (3A) : 2 Pcs , OPTIONAL ACCESSORIES:5/10/20/50mm Glass cell, 5/ 10/ 20/50Quartz Cell, 50mm cell holder, 100mm Cell Holder, Tungsten- halogen Lamp (12V 30W) , Printer.

View Complete Details

UV-VIS Spectrophotometer

  • range 195 to 1000 nm
  • Spectral band width 2 nm
  • Accuracy ± 0.5 nm
  • Repeatability ± 0.3 nm
  • Resolution 0.1nm%

Spectral wavelength range: 195 to 1000 nm.Spectralband width: 2 nm.Accuracy: 0.5 nm.Repeatability: 0.3 nm, Resolution: 0.1nm% T:0 to 100%Abs.:0 to 1.999Conc.: 0 to 1999, K Factor: 0 to 1999, Accuracy: 0.005 Abs at 1.0 Abs, 0.010 Abs at 1.5 Abs, Stray Light: Less than 0.1%at 320 nm, Readability: 1 count, Data Readout: Single Line LCD Display.Key Board: 4 Keys, soft touch membrane type.Printer Interface: Printer Interface for any centronics Dot Matrix Printer , Serial Interface: RS 232C interface, Light Source(a)Tungsten Halogen Lamp (b) Deuterium Lamp (D2), Detector: Wide range silicon Photodiode.Optics: Complete mirror optics with resolution 1200 grooves / mm grating, Sample Holder: 4 Position adjustable sample holder, Power:230 V 10% 50 Hz AC , Dimensions: 420 x 350 x 240mm (LXBXH) Approx., Weight:10 Kg. (Approx.)Accessories: Quartz Cuvete(2), Glass Cuvete(4), Dust Cover,

CD(1), Interface cable(1), manual(1).

View Complete Details

Double Beam UV- Visible Spectrophotometer

  • Range 190-1100nm.
  • Mode Basic/ Quantitative/Wavelength Scan/DNA Protein Test/Kinetics
  • Scanning Speed Fast / Medium / Slow
  • Accuracy +0.1 nm.
  • Weight 26 Kg

Technical specifications:

WavelengthRange:190-1100nm.Mode:Basic/ Quantitative/Wavelength Scan/DNA Protein Test/Kinetics.Scanning Speed :Fast / Medium / Slow.Wavelength Accuracy:+0.1 nm.

Bandwidth:1 nm.Wavelength Reproducibility:0.1 nm.PhotometricRange:0-200 % T, -0.3 to 3.0 A, 0 to 9999 C.Photometric Accuracy:+0.3 % T.Photometric Reproducibility:+ 0.2 % T.Stability0.001A/h @ 500 nm.Baseline Flatness:+ 0.001 A, Noise:+0.001A.Stray Light:

View Complete Details

Single Beam Uv Vis Spectrophotometer

  • Wavelength Range 190 to 1000 nm.
  • Band width: 2 nm.
  • Accuracy ± 1nm.
  • Stability ± 0.002A/h@500nm
  • Display 128*64Dots LCD

Advance Microprocessor

UVVISSpectrophotometer Single Beam NSP - 370

Technical Specifications:

Optical System :Single beam, grating 1200 lines/mm

Wavelength range: 190 to 1000 nm.

Band width: 2 nm.

WavelengthAccuracy: 1nm.

Wavelength Repeatability: 0.5 nm,

Wavelength Setting :Auto

Photometric Accuracy : 0.5%T

Photometric Repeatability : 0.3%T

Photometric Range :-0.3-3A, 0-200%T

Stray Light :0.3%T

Stability : 0.002A/h@500nm

Display :128*64Dots LCD

Detector :Silicon Photodiode

Standard Cell Holder :4-position 10mm cell charger

Light SourceTungsten & Deuterium Lamp

Output :USB port &ParallelPort(Printer)

Power Requirements:AC 85250V

Dimensions: 420 x 280 x 180mm (LXBXH)

Weight:12 Kg

Salient Features :

  • Large LCD Screen (128X64 Doys).
  • Can Display and save 50 groups of data, 5 groups per screen.
  • Data can be restore after a sudden power cut.
  • Auto setting wavelength.
  • Tungsten lamp & deuterium lamp cab be turned on/off individually to extend lifetime.
  • Automatical WL. Calibration and dark current getting.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Spectrophotometers from Delhi, Delhi by Naina Solaris Limited
Post Buy Requirement
NS

Naina Solaris Limited

Add Review

Spectrophotometers

We offer the best product range of spectro photometer, Spectrophotometer, Digital Spectrophotometer, MICROPROCESSOR VISIBLE SPECTROPHOTOMETER and UV-VIS Spectrophotometer.

Spectro Photometer

Visible spectrophotometer NSP 365 having range 340 to 960nm. Dual LED display for %T, ABS & Concentration. Resolution 1nm.Mains operated.Complete with standard accessories.
View Complete Details

Spectrophotometer

Digital Spectrophotometer NSP 365: display: Dual LED Display.Measuring Parameter 3[ Absorbance: 0 to 1999, %Transmission: 0 to 100%, Concentration: 0 to 1999.Detector: silicon photo diode.Grating: 600lines/mm.Light source: Tungsten halogen lamp.Spectral band width: 10mm.Wave length resolution: 1nm. wavelength accuracy: 1nm.Mains: 230VAC.Complete with standard accessories.

Additional Information:

Payment Terms : T/T

Packaging Details : Standard Corrugated Box.

Delivery Time : 1 week

View Complete Details

Digital Spectrophotometer

  • Range 340 - 960 nm
  • Resolution 0.1 %T, 0.001 Abs
  • Output 0 to 100%
  • Weight 8.0kgs (approx).

Technical Specifications

Range:340 - 960 nm.Resolution:0.1 %T, 0.001 Abs.Output :% T:0to 100%.Abs.: 0 to 1.999.Conc. : 0 to 1999.Detector: Silicon Photodiode.Light Source: 6V, 1 Amp, Tungsten Halogen Lamp.Monochromator: 600 Lines/mm grating.Path Length: 10mm.

SpectralBandwidth:10 nm.Wavelength resolution:1nmon digital display, Wavelength accuracy:

1 nm.Repeatability: 1 nm.Display:3 1/2 digit LED display.Operating Temp.: 5to 45 C.Power: 230V 10%AC 50 Hz.Size(L x B x H): 460 x320 x 185 mm.Weight: 8.0kgs (approx).Accessories:Test tubes, Dust Cover, Instruction manual

View Complete Details

MICROPROCESSOR VISIBLE SPECTROPHOTOMETER

  • Weight 13.5 Kgs
  • Wavelength Range 325-1000nm
  • Accuracy < 2nm
  • Repeatability < 1nm
  • Dimensions 56 x 48x 29 cms

CHARACTERISTICS

The monochromator with a holographic flashing grating is used. It has the advantage of high wavelength precision, good monochromaticity and low stray light. Automatic switching of tungsten halogen lamp and deuterium lamp. A sample compartment for 0.5cm-10cm cells. Computer control system, precise automatic T/A changeover. Automatic zero and full scale adjustment. Direct concentration read-out and concentration factor setting function. Equipped with RS232 port. Printer can be connected and data can be sent to PC by special software.

SPECTIFICATIONS

WavelengthRange: 325-1000nm, Wavelength Accuracy: < 2nm, Wavelength Repeatability: < 1nm

Transmittance Accuracy:+0.5%, Transmittance Repeatability: < 0.2%, Spectrum Bandwidth:5nmStray Light: < 0.5% (at 360nm, Nano2), Light Current Drift:0.5% / 3 min, Dark Current Drift: 0.2% / 3 min

Cell Holder: 10mm, Dimensions: 56 x 48x 29 cms, Net Weight: 13.5 Kgs, Gross Weight: 27 Kgs

STANDARD CONFIGURATION:Main Instrument : 1 Unit, Operational Manual : 1 Pc, Glass Cell 10mm : 4 Pcs, Power Cable : 1 Pc, Fuse (3A) : 2 Pcs , OPTIONAL ACCESSORIES:5/10/20/50mm Glass cell, 5/ 10/ 20/50Quartz Cell, 50mm cell holder, 100mm Cell Holder, Tungsten- halogen Lamp (12V 30W) , Printer.

View Complete Details

UV-VIS Spectrophotometer

  • range 195 to 1000 nm
  • Spectral band width 2 nm
  • Accuracy ± 0.5 nm
  • Repeatability ± 0.3 nm
  • Resolution 0.1nm%

Spectral wavelength range: 195 to 1000 nm.Spectralband width: 2 nm.Accuracy: 0.5 nm.Repeatability: 0.3 nm, Resolution: 0.1nm% T:0 to 100%Abs.:0 to 1.999Conc.: 0 to 1999, K Factor: 0 to 1999, Accuracy: 0.005 Abs at 1.0 Abs, 0.010 Abs at 1.5 Abs, Stray Light: Less than 0.1%at 320 nm, Readability: 1 count, Data Readout: Single Line LCD Display.Key Board: 4 Keys, soft touch membrane type.Printer Interface: Printer Interface for any centronics Dot Matrix Printer , Serial Interface: RS 232C interface, Light Source(a)Tungsten Halogen Lamp (b) Deuterium Lamp (D2), Detector: Wide range silicon Photodiode.Optics: Complete mirror optics with resolution 1200 grooves / mm grating, Sample Holder: 4 Position adjustable sample holder, Power:230 V 10% 50 Hz AC , Dimensions: 420 x 350 x 240mm (LXBXH) Approx., Weight:10 Kg. (Approx.)Accessories: Quartz Cuvete(2), Glass Cuvete(4), Dust Cover,

CD(1), Interface cable(1), manual(1).

View Complete Details

Double Beam UV- Visible Spectrophotometer

  • Range 190-1100nm.
  • Mode Basic/ Quantitative/Wavelength Scan/DNA Protein Test/Kinetics
  • Scanning Speed Fast / Medium / Slow
  • Accuracy +0.1 nm.
  • Weight 26 Kg

Technical specifications:

WavelengthRange:190-1100nm.Mode:Basic/ Quantitative/Wavelength Scan/DNA Protein Test/Kinetics.Scanning Speed :Fast / Medium / Slow.Wavelength Accuracy:+0.1 nm.

Bandwidth:1 nm.Wavelength Reproducibility:0.1 nm.PhotometricRange:0-200 % T, -0.3 to 3.0 A, 0 to 9999 C.Photometric Accuracy:+0.3 % T.Photometric Reproducibility:+ 0.2 % T.Stability0.001A/h @ 500 nm.Baseline Flatness:+ 0.001 A, Noise:+0.001A.Stray Light:

View Complete Details

Single Beam Uv Vis Spectrophotometer

  • Wavelength Range 190 to 1000 nm.
  • Band width: 2 nm.
  • Accuracy ± 1nm.
  • Stability ± 0.002A/h@500nm
  • Display 128*64Dots LCD

Advance Microprocessor

UVVISSpectrophotometer Single Beam NSP - 370

Technical Specifications:

Optical System :Single beam, grating 1200 lines/mm

Wavelength range: 190 to 1000 nm.

Band width: 2 nm.

WavelengthAccuracy: 1nm.

Wavelength Repeatability: 0.5 nm,

Wavelength Setting :Auto

Photometric Accuracy : 0.5%T

Photometric Repeatability : 0.3%T

Photometric Range :-0.3-3A, 0-200%T

Stray Light :0.3%T

Stability : 0.002A/h@500nm

Display :128*64Dots LCD

Detector :Silicon Photodiode

Standard Cell Holder :4-position 10mm cell charger

Light SourceTungsten & Deuterium Lamp

Output :USB port &ParallelPort(Printer)

Power Requirements:AC 85250V

Dimensions: 420 x 280 x 180mm (LXBXH)

Weight:12 Kg

Salient Features :

  • Large LCD Screen (128X64 Doys).
  • Can Display and save 50 groups of data, 5 groups per screen.
  • Data can be restore after a sudden power cut.
  • Auto setting wavelength.
  • Tungsten lamp & deuterium lamp cab be turned on/off individually to extend lifetime.
  • Automatical WL. Calibration and dark current getting.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us