Sub Zero Dry Block Temperature Calibrator

We offer Sub Zero Dry Block Temperature Calibrator.Microprocessor based Sub Zero Dry Block Temperature Calibrator with Temperature Range -40C from Ambient to 123C & Accuracy 0.3C.
View Complete Details

Mpce Series Pneumatic Pressure Calibrators

We offer Mpce Series Pneumatic Pressure Calibrators.Microprocessor based Economy Pressure Calibrators available in several ranges from -0.85 (vac.) to 40 bar with an Accuracy of 0.1% FS
View Complete Details

Temperature Dry Block Calibrator

  • Accuracy ±0.2°C
  • Range 10°C to 120°C
  • Range -10°C to 120°C
  • Resolution 0.01°C
  • Stability ±0.02°C
  • Stabilisation Time 7 Minutes
  • Temperature Readout °C / °F Switcheable
  • Axial Uniformity (40 mm) ±0.2°C
  • Radial Uniformity ±0.02°C
  • Well Diameter 30 mm
  • Immersion Depth 150 mm
  • Heating Time (Amb. to 120°C) 10 Minutes approx.
  • Cooling Time (Amb. to -10°C) 15 Minutes approx.
  • Cooling Time (120 to -10°C) 25 Minutes approx.
  • Switch Test facility Provided
  • Interchangeable Thermowells Multihole to suit 2 x ¼” & 1 x ½” Probes. Other Sizes available as optional
  • Housing Bench-top
  • Power Supply 110V AC to 240V AC, 50 to 60 Hz
  • Instrument Dimensions (L x D x H) 160 x 365 x 450 mm
  • Instrument Weight (approx.) 9 Kg.
METCAL 40

Advanced Micro-controller based TechnologyHeavy Duty Portable / Bench-top ModelHigh Accuracy, Resolution, Uniformity & StabilityLarge Graphic Display (Multi-information Display)Measurement Capability for TC, RTD, mV / mA / V & Resistance SignalsTouch Membrane KeypadSwitch Test Contact MeasurementMulti-hole Thermowell InsertsRS-232 Interface & Calibration SoftwareCount down timer (Shows when unit is stable)Stability Indicator

Type Range Resolution Accuracy (% of reading)   Type Range Resolution Accuracy
mV (Low) 0 to 100 0.001 ±(0.025%+2µV)   TC Type R 150 to 1700 0.1 ±(0.025%+0.2°C)
mV (High) 0 to 1000 0.01 ±(0.025%+10µV)   TC Type S 170 to 1700 0.1 ±(0.025%+0.2°C)
Volts 0 to 10 0.0001 ±(0.025%+0.08mV)   TC Type N 0 to 1300 0.1 ±(0.025%+0.1°C)
mA 0 to 25 0.0001 ±(0.025%+0.4µA)   RTD Pt100 -100 to 800 0.01 ±(0.025%+0.1°C)
Ohms 0 to 500 0.001 ±(0.025%+12mâ¦)   RTD Pt200 -100 to 600 0.1 ±(0.025%+0.15°C)
KOhms 0 to 3.5 0.00001 ±(0.025%+120mâ¦)   RTD Pt500 -100 to 530 0.1 ±(0.025%+0.1°C)
TC Type J -100 to 1200 0.1 ±(0.025%+0.1°C)   RTD Pt1000 -100 to 650 0.01 ±(0.025%+0.1°C)
TC Type K -60 to 1260 0.1 ±(0.025%+0.1°C)        
View Complete Details

Low Temperature Calibration Source

  • Model BBSL
  • Range 10°C above Ambient to 350°C
  • Accuracy Within 0.5% F.S. (Min. 1°C)
  • Emissivity 0.98
  • Aperture Dia 25 mm
  • Stability ±0.5°C
  • Resolution 0.1°C
  • Temperature Control Auto-tune PID Controller
  • Heating time (Ambient to max.) 45 Minutes
  • Stabilization time (above 75°C) 20 minutes
  • Temperature Readout °C / °F selectable
  • Power Supply / Consumption 230V AC / 50 Hz / 350 W
  • Dimension (L x D x H) 485 x 430 x 190 mm
  • Weight 11 Kg.
  • Housing / Mounting Bench-top (Portable)

Compact, Light Weight & Portable

High Emissivity, Wide Aperture

Excellent Accuracy & Stability

Auto-tune PID Controller

Low Power Consumption

Cost effective Best value for Money

RS-232 Interface & Calibration Software Optional

View Complete Details

Pneumatic Pressure Calibrator

  • Accuracy ±0.1% F.S.
  • Weight 5 Kg.
  • Ranges 0.85 to 2 / 10 / 20 / 35 / 40 / 60 bar
  • Resolution Minimum 4½ digits
  • Display 2 line, 16 characters LCD (Alpha-Numeric)
  • Engineering Units Mpa, Atm, Bar, Kg/cm2, mH2O, PSI, inHg, ftH2O, Kpa, inH2O, mmHg, cmH2O
  • mA Input 0 to 25 mA DC (Active)
  • Pressure Switch Test Maximum 5V DC
  • Over Pressure Alarm 105% FS (Audio / Visual)
  • Pressure Generation Thro’ Matching Pneumatic Hand Pump with Fine Adjustment Vernier & Release Valve
  • Battery Type & Life 9 Volts; Approx. 12 Hours
  • Low Battery Indication Provided
  • Instrument Dimension 420 x 340 x 120 mm (L x B x H)              

2 Line Alpha Numeric Display

Touch Membrane Keypad

Selectable Engineering Pressure Units

DC Current Measurement : 0 to 25 mA (Active)

Switch Test capability & Zero Offset facility

Audio & Visual Alarms for Over Pressure

Pressure Transducer all Media compatible with SS316

9V Battery operated with Low Battery indication

Digital Pressure Indicator with matching Pneumatic Hand Pump with Vernier

View Complete Details

Thermocouple Calibrator

Compact, Light Weight Unit with Holster

Selectable Temperature Output Readings (in C / F)

Measurement & Simulation of

Thermocouple types R, S, B, E, K, J, T & N

Voltage 1 V Simulation, 100 mV Measurement

Input Range Input range Resolution Accuracy Remarks
Voltage (DC) 100 mV -10 to 110 mV 10 mV ±0.05% measured value

 

± 30 mV

Input Resistance 1MW
Thermocouple R -40 to 1760°C 1°C ±0.05% measured value ±3°C (<100°C)

 

±0.05% measured value ±2°C (>100°C)

Input Resistance 1MW
S -20 to 1760°C 1°C
B 400 to 1800°C 1°C ±0.05% measured value ±3°C (400 to 600°C)

 

±0.05% measured value ±2°C (>600°C)

E -200 to 1000°C 0.1°C ±0.05% measured value ±2°C (< -100°C)

 

±0.05% measured value ±1°C (> -100°C)

K -200 to 1370°C 0.1°C
J -200 to 1200°C 0.1°C
T -200 to 400°C 0.1°C
N -200 to 1300°C 0.1°C
 