Our Products
Measuring Instruments & Equipment
2 Products availableButtons
2 Products availableRelays & Contactors
1 Products availableMotor Control Panels
1 Products availablePower Contactors
1 Products availableOur offered Product range includes lighting capacitors, Submersible Panel Capacitors, Motor Start Capacitors, Motor Run Capacitors and Power Capacitor-Square.
Lightening Fixtures (Indoor/Outdoor)
Parameter |
Unit |
Lighting Capacitor |
Ref Standard |
||
Electrical Ratings: |
||
Rated Voltage |
V |
250 |
Rated Capacitance |
µF |
8-42 µF |
Rated Frequency |
Hz |
50 |
Capacitance Tolerance |
% |
+/-5% |
Test Data: |
||
AC Test Voltage Terminal To Terminal |
V |
1.5 x Rated Voltage |
Insulation Voltage between Terminal & Container |
V |
2000 V |
Design Data: |
||
Case Material |
Plastic Case |
|
Dielectric |
Polypropylene |
|
Impregnation |
Polyurethane Resin |
|
Terminals |
Flexible Wire & Tag Terminals |
|
Climatic Parameter: |
||
Temperature Limit min/max |
°C |
40/70/21 |
Test Duration |
Days |
21 |
Parameter |
Unit |
Submersible Panel Capacitor |
Ref Standard |
||
Electrical Ratings: |
||
Rated Voltage |
V |
250 |
Rated Capacitance |
µF |
25-105 µF |
Rated Frequency |
Hz |
50 |
Capacitance Tolerance |
% |
+/-5% |
Test Data: |
||
AC Test Voltage Terminal To Terminal |
V |
2 x Rated Voltage |
Insulation Voltage between Terminal & Container |
V |
2000 V |
Design Data: |
||
Case Material |
Plastic Case |
|
Dielectric |
Polypropylene |
|
Impregnation |
Polyurethane Resin |
|
Terminals |
Flexible Wire & Tag Terminals |
|
Climatic Parameter: |
||
Temperature Limit min/max |
°C |
-25/70 |
Test Duration |
Days |
21 |
Parameter |
Unit |
Motor Start Capacitor |
Ref Standard |
||
Electrical Ratings: |
||
Rated Voltage |
V |
230 |
Rated Capacitance |
µF |
30-150 µF |
Rated Frequency |
Hz |
50 |
Capacitance Tolerance |
% |
+/-5% |
Test Data: |
||
AC Test Voltage Terminal To Terminal |
V |
1.2 x Rated Voltage |
Insulation Voltage between Terminal & Container |
V |
2000 V |
Design Data: |
||
Case Material |
Plastic Case |
|
Dielectric |
Polypropylene |
|
Impregnation |
Polyurethane Resin |
|
Terminals |
Flexible Wire & Tag Terminals |
|
Climatic Parameter: |
||
Temperature Limit min/max |
°C |
-25/70 |
Test Duration |
Days |
21 |
MRC series capacitors are designed to suit the Motor Industry. With ISS 2993:1998, our MRC ensures smooth running of Motors for longer period of time.
Salient Features
Parameter |
Unit |
Motor Run Capacitor |
Ref Standard |
||
Electrical Ratings: |
||
Rated Voltage |
V |
440 |
Rated Capacitance |
µF |
2-72 µF |
Rated Frequency |
Hz |
50 |
Capacitance Tolerance |
% |
+/-5% |
Test Data: |
||
AC Test Voltage Terminal To Terminal |
V |
2 x Rated Voltage |
Insulation Voltage between Terminal & Container |
V |
2000 V |
Design Data: |
||
Case Material |
Plastic Case |
|
Dielectric |
Polypropylene |
|
Impregnation |
Polyurethane Resin |
|
Terminals |
Flexible Wire & Tag Terminals |
|
Climatic Parameter: |
||
Temperature Limit min/max |
°C |
-25/85 |
Test Duration |
Days |
21 |
MKC Series KVAr are best suited for optimizing the power factor system. These PFC are designed for Heavy Duty operations for Indian Voltage conditions.
Major Values (KVAr):
1, 2, 3, 5, 6, 8, 10, 12.5, 15, 20, 25
*Customized ratings & construction can also be made available on request
Application:
Power Factor Correction
Salient FeaturesMKC Series KVAr are best suited for optimizing the power factor system. These PFC are designed for Heavy Duty operations for Indian Voltage conditions.
Major Values (KVAr):
1, 2, 3, 5, 6, 8, 10, 12.5, 15, 20, 25
*Customized ratings & construction can also be made available on request
Application:
Power Factor Correction
Salient FeaturesMKC Series KVAr are best suited for optimizing the power factor system. These PFC are designed for Heavy Duty operations for Indian Voltage conditions.
Major Values (KVAr):
1, 2, 3, 5, 6, 8, 10, 12.5, 15, 20, 25
*Customized ratings & construction can also be made available on request
Application:
Power Factor Correction
Salient FeaturesReduction in Voltage Drop, Improved Voltage Regulation
MFC series capacitors are specially designed for Fan industry. PP Can, PU filled-dry type capacitor is more economical and has higher efficiency.
Major Values (F):
1.7, 2.0, 2.25, 2.5, 3.15, 4.0, 6.0, 8.0, 10.0
Salient Features
Parameter |
Unit |
Fan Capacitor |
Ref Standard |
IS:1709 & IS:2993 |
|
Electrical Ratings: |
||
Rated Voltage |
V |
440 |
Rated Capacitance |
µF |
1-10 µF |
Rated Frequency |
Hz |
50/60 |
Capacitance Tolerance |
% |
+/-5% |
Test Data: |
||
AC Test Voltage Terminal To Terminal |
V |
1.5 x Rated Voltage |
Insulation Voltage between Terminal & Container |
V |
2000 V |
Design Data: |
||
Case Material |
Plastic Case |
|
Dielectric |
Polypropylene |
|
Impregnation |
Polyurethane Resin |
|
Terminals |
Flexible Wire & Tag Terminals |
|
Climatic Parameter: |
||
Temperature Limit min/max |
°C |
-25/70/21 (As per IS:1709) |
-25/85/21 (As per IS:2993) |
||
Test Duration |
Days |
21 |