Our Products
Water Pumps
2 Products availableMonoblock Pumps
1 Products availablePumps, Pumping Machines & Parts
1 Products availableIndustrial Pump
1 Products availableWe offer a complete product range of Three Phase Double Cylinder Air Cooled Diesel Generator, Three Phase Alternator, 300 Amps Welding Generator, Single Phase Water Air Cooled Diesel Generator and Double Phase Water Air Cooled Diesel Generator
Specification
Single Phase 230 V 50 Hz 1.0 PF 1600 RPM Water Air Cooled | |||||||
---|---|---|---|---|---|---|---|
KVA | KW | H.P | AMP | Bore | Cylinder | Flywheel Casting (Kg.) |
Net Wt. (Kg.) |
3 | 3 | 5 | 12 | 85 | Single | 34 Kg. | 140 Kg. |
4 | 4 | 6 | 16 | 85 | Single | 45 Kg. | 170 Kg. |
5 | 5 | 8 | 20 | 87 | Single | 48 Kg. | 200 Kg. |
6 | 6 | 10 | 24 | 95 | Single | 58 Kg. | 230 Kg. |
7.5 | 7.5 | 12 | 28 | 102 | Single | 64 Kg. | 255 Kg. |
8 | 8 | 12 | 36 | 114 | Single | 70 Kg. | 270 Kg. |
10 | 9 | 14 | 40 | 114 | Single / Double | 80 Kg. | 300 Kg. |
12.5 | 12.5 | 16 | 48 | 95 | Single / Double | 70 Kg. | 350 Kg. |
15 | 14 | 24 | 56 | 102 | Double | 70 Kg. | 400 Kg. |
20 | 18 | 28 | 64 | 114.3 | Double | 80 Kg. | 450 Kg. |
25 | 22 | 32 | 67 | 116 | Double | 100 Kg. | 500 Kg. |
Three Phase 415 V 50 HZ 0.8 PF 1600 RPM Water Air Cooled
KVA | KW | H.P | AMP | Bore | Cylinder | Flywheel Casting (Kg.) |
Net Wt. (Kg.) |
---|---|---|---|---|---|---|---|
6 | 5 | 10 | 8 | 87 | Single | 48 Kg. | 240 Kg. |
7.5 | 7.5 | 12 | 10 | 95 | Single | 58 Kg. | 265 Kg. |
8.5 | 8.5 | 12 | 11 | 102 | Single | 64 Kg. | 280 Kg. |
10 | 9.5 | 14 | 13 | 114 | Single / Double | 70 Kg. | 310 Kg. |
12.5 | 12.5 | 16 | 16 | 114 | Single / Double | 80 Kg. | 360 Kg. |
15 | 14.5 | 24 | 23 | 102 | Double | 70 Kg. | 410 Kg. |
20 | 18.5 | 28 | 26 | 114 | Double | 80 Kg. | 460 Kg. |
25 | 22 | 32 | 67 | 116 | Double | 100 Kg. | 510 Kg. |
Salient Features :
Construction :
Electrical performance :
Specification
Singal Phase. 230V. 50 Hz. 1.0Pf. 1500RPM | ||||
---|---|---|---|---|
Technical Specification | ||||
KVA | KW | Suitable Load (H.P) | AMP | Required Engine (H.P) |
2 | 2 | 0.5 | 8 | 3.5 |
3 | 3 | 1 | 12 | 5 |
4 | 4 | 1 | 16 | 6.5 |
5 | 5 | 2 | 21 | 8 |
6 | 6 | 3 | 24 | 10 |
7 | 7 | 4 | 28 | 12 |
9 | 9 | 5 | 36 | 14 |
10 | 10 | 6 | 40 | 15 |
12 | 12 | 7 | 48 | 20 |
15 | 15 | 10 | 60 | 24 |
20 | 20 | 12 | 80 | 28 |
25 | 25 | 15 | 100 | 35 |
30 | 30 | 20 | 120 | 42 |
Three Phase, 415V, 50 Hz, 0.8Pf, 1500RPM
Technical Specification | ||||
---|---|---|---|---|
KVA | KW | Suitable Load (H.P) | AMP | Required Engine (H.P) |
6 | 5 | 3 | 8 | 8 |
7 | 6 | 4 | 10 | 10 |
8 | 7 | 5 | 12 | 12 |
10 | 8 | 6 | 14 | 14 |
12 | 10 | 7 | 17 | 15 |
15 | 12 | 10 | 21 | 20 |
20 | 16 | 12 | 28 | 28 |
25 | 20 | 15 | 35 | 32 |
30 | 24 | 20 | 42 | 40 |
35 | 28 | 22 | 49 | 50 |
40 | 32 | 25 | 54 | 55 |
50 | 40 | 35 | 66 | 72 |
62 | 50 | 42 | 84 | 95 |
75 | 60 | 52 | 97 | 112 |
82 | 66 | 60 | 107 | 125 |
100 | 80 | 75 | 130 | 142 |
Salient Features :
Specification
AC Welding Generator | ||||
---|---|---|---|---|
AMP. | Welding Rod (NO./ MM) | Domestic Supply | H.P. | Cylinder |
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW / 1230 V/60 V | 12 HP | SINGLE |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW / 1230 V/60 V | 14 HP | SINGLE |
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW / 1230 V/70 V | 24 HP | DOUBLE |
AC Current Welding Alternator
AMP. | Welding Rod (NO./ MM) | Domestic Supply |
---|---|---|
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW/230 V |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW/230 V |
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW/230 V |
Specification
Single Phase 230 V 50 Hz 1.0 PF 1600 RPM Water Air Cooled | |||||||
---|---|---|---|---|---|---|---|
KVA | KW | H.P | AMP | BORE | Cylinder | Flywheel Casting (Kg.) |
Net Wt. (Kg.) |
3 | 3 | 5 | 12 | 85 | Single | 34 Kg. | 140 Kg. |
4 | 4 | 6 | 16 | 85 | Single | 45 Kg. | 170 Kg. |
5 | 5 | 8 | 20 | 87 | Single | 48 Kg. | 200 Kg. |
6 | 6 | 10 | 24 | 95 | Single | 58 Kg. | 230 Kg. |
7.5 | 7.5 | 12 | 28 | 102 | Single | 64 Kg. | 255 Kg. |
8 | 8 | 12 | 36 | 114 | Single | 70 Kg. | 270 Kg. |
10 | 9 | 14 | 40 | 114 | Single / Double | 80 Kg. | 300 Kg. |
12.5 | 12.5 | 16 | 48 | 95 | Single / Double | 70 Kg. | 350 Kg. |
15 | 14 | 24 | 56 | 102 | Double | 70 Kg. | 400 Kg. |
20 | 18 | 28 | 64 | 114.3 | Double | 80 Kg. | 450 Kg. |
25 | 22 | 32 | 67 | 116 | Double | 100 Kg. | 500 Kg. |
Specification
Single Phase 230 V 50 Hz 1.0 PF 1600 RPM Water Air Cooled | |||||||
---|---|---|---|---|---|---|---|
KVA | KW | H.P | AMP | BORE | Cylinder | Flywheel Casting (Kg.) |
Net Wt. (Kg.) |
3 | 3 | 5 | 12 | 85 | Single | 34 Kg. | 140 Kg. |
4 | 4 | 6 | 16 | 85 | Single | 45 Kg. | 170 Kg. |
5 | 5 | 8 | 20 | 87 | Single | 48 Kg. | 200 Kg. |
6 | 6 | 10 | 24 | 95 | Single | 58 Kg. | 230 Kg. |
7.5 | 7.5 | 12 | 28 | 102 | Single | 64 Kg. | 255 Kg. |
8 | 8 | 12 | 36 | 114 | Single | 70 Kg. | 270 Kg. |
10 | 9 | 14 | 40 | 114 | Single / Double | 80 Kg. | 300 Kg. |
12.5 | 12.5 | 16 | 48 | 95 | Single / Double | 70 Kg. | 350 Kg. |
15 | 14 | 24 | 56 | 102 | Double | 70 Kg. | 400 Kg. |
20 | 18 | 28 | 64 | 114.3 | Double | 80 Kg. | 450 Kg. |
25 | 22 | 32 | 67 | 116 | Double | 100 Kg. | 500 Kg. |
Three Phase 415 V 50 HZ 0.8 PF 1600 RPM Water Air Cooled
KVA | KW | H.P | AMP | BORE | Cylinder | Flywheel Casting (Kg.) |
Net Wt. (Kg.) |
---|---|---|---|---|---|---|---|
6 | 5 | 10 | 8 | 87 | Single | 48 Kg. | 240 Kg. |
7.5 | 7.5 | 12 | 10 | 95 | Single | 58 Kg. | 265 Kg. |
8.5 | 8.5 | 12 | 11 | 102 | Single | 64 Kg. | 280 Kg. |
10 | 9.5 | 14 | 13 | 114 | Single / Double | 70 Kg. | 310 Kg. |
12.5 | 12.5 | 16 | 16 | 114 | Single / Double | 80 Kg. | 360 Kg. |
15 | 14.5 | 24 | 23 | 102 | Double | 70 Kg. | 410 Kg. |
20 | 18.5 | 28 | 26 | 114 | Double | 80 Kg. | 460 Kg. |
25 | 22 | 32 | 67 | 116 | Double | 100 Kg. | 510 Kg. |
Specification
AC Welding Generator | ||||
---|---|---|---|---|
AMP. | Welding Rod (NO./ MM) | Domestic Supply | H.P. | Cylinder |
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW / 1230 V/60 V | 12 HP | Single |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW / 1230 V/60 V | 14 HP | Single |
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW / 1230 V/70 V | 24 HP | Double |
AC Current Welding Alternator
AMP. | Welding Rod (NO./ MM) | Domestic Supply |
---|---|---|
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW/230 V |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW/230 V |
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW/230 V |
Specification
Single Phase 230 V 50 Hz 1.0 PF 1600 RPM Water Air Cooled | |||||||
---|---|---|---|---|---|---|---|
KVA | KW | H.P | AMP | BORE | Cylinder | Flywheel Casting (Kg.) |
Net Wt. (Kg.) |
3 | 3 | 5 | 12 | 85 | Single | 34 Kg. | 140 Kg. |
4 | 4 | 6 | 16 | 85 | Single | 45 Kg. | 170 Kg. |
5 | 5 | 8 | 20 | 87 | Single | 48 Kg. | 200 Kg. |
6 | 6 | 10 | 24 | 95 | Single | 58 Kg. | 230 Kg. |
7.5 | 7.5 | 12 | 28 | 102 | Single | 64 Kg. | 255 Kg. |
8 | 8 | 12 | 36 | 114 | Single | 70 Kg. | 270 Kg. |
10 | 9 | 14 | 40 | 114 | Single / Double | 80 Kg. | 300 Kg. |
12.5 | 12.5 | 16 | 48 | 95 | Single / Double | 70 Kg. | 350 Kg. |
15 | 14 | 24 | 56 | 102 | Double | 70 Kg. | 400 Kg. |
20 | 18 | 28 | 64 | 114.3 | Double | 80 Kg. | 450 Kg. |
25 | 22 | 32 | 67 | 116 | Double | 100 Kg. | 500 Kg. |
Three Phase 415 V 50 HZ 0.8 PF 1600 RPM Water Air Cooled
KVA | KW | H.P | AMP | BORE | CYLINDER | FLYWHEEL Casting (Kg.) |
NET WT. (Kg.) |
6 | 5 | 10 | 8 | 87 | Single | 48 Kg. | 240 Kg. |
7.5 | 7.5 | 12 | 10 | 95 | Single | 58 Kg. | 265 Kg. |
8.5 | 8.5 | 12 | 11 | 102 | Single | 64 Kg. | 280 Kg. |
10 | 9.5 | 14 | 13 | 114 | Single / Double | 70 Kg. | 310 Kg. |
12.5 | 12.5 | 16 | 16 | 114 | Single / Double | 80 Kg. | 360 Kg. |
15 | 14.5 | 24 | 23 | 102 | Double | 70 Kg. | 410 Kg. |
20 | 18.5 | 28 | 26 | 114 | Double | 80 Kg. | 460 Kg. |
25 | 22 | 32 | 67 | 116 | Double | 100 Kg. | 510 Kg. |
Specification
AC Welding Generator | ||||
---|---|---|---|---|
AMP. | Welding Rod (NO./ MM) | Domestic Supply | H.P. | Cylinder |
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW / 1230 V/60 V | 12 HP | Single |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW / 1230 V/60 V | 14 HP | Single |
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW / 1230 V/70 V | 24 HP | Double |
AC Current Welding Alternator
AMP. | Welding Rod(NO./ MM) | Domestic Supply |
---|---|---|
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW/230 V |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW/230 V |
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW/230 V |
Specification
Single Phase. 230V. 50 Hz. 1.0Pf. 1500RPM | ||||
---|---|---|---|---|
Technical Specification | ||||
KVA | KW | Suitable Load (H.P) | AMP | Required Engine (H.P) |
2 | 2 | 0.5 | 8 | 3.5 |
3 | 3 | 1 | 12 | 5 |
4 | 4 | 1 | 16 | 6.5 |
5 | 5 | 2 | 21 | 8 |
6 | 6 | 3 | 24 | 10 |
7 | 7 | 4 | 28 | 12 |
9 | 9 | 5 | 36 | 14 |
10 | 10 | 6 | 40 | 15 |
12 | 12 | 7 | 48 | 20 |
15 | 15 | 10 | 60 | 24 |
20 | 20 | 12 | 80 | 28 |
25 | 25 | 15 | 100 | 35 |
30 | 30 | 20 | 120 | 42 |
Three Phase, 415V, 50 Hz, 0.8Pf, 1500RPM
Technical Specification | ||||
---|---|---|---|---|
KVA | KW | Suitable Load (H.P) | AMP | Required Engine (H.P) |
6 | 5 | 3 | 8 | 8 |
7 | 6 | 4 | 10 | 10 |
8 | 7 | 5 | 12 | 12 |
10 | 8 | 6 | 14 | 14 |
12 | 10 | 7 | 17 | 15 |
15 | 12 | 10 | 21 | 20 |
20 | 16 | 12 | 28 | 28 |
25 | 20 | 15 | 35 | 32 |
30 | 24 | 20 | 42 | 40 |
35 | 28 | 22 | 49 | 50 |
40 | 32 | 25 | 54 | 55 |
50 | 40 | 35 | 66 | 72 |
62 | 50 | 42 | 84 | 95 |
75 | 60 | 52 | 97 | 112 |
82 | 66 | 60 | 107 | 125 |
100 | 80 | 75 | 130 | 142 |
Specification
AC Welding Generator | |||||
---|---|---|---|---|---|
AMP. | Welding Rod (NO./ MM) | Domestic Supply | H.P. | Cylinder | |
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW / 1230 V/60 V | 12 HP | Single | |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW / 1230 V/60 V | 14 HP |
|
|
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW / 1230 V/70 V | 24 HP | Double |
AC Current Welding Alternator
AMP. | Welding Rod (NO./ MM) | Domestic Supply |
---|---|---|
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW/230 V |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW/230 V |
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW/230 V |
Specification
AC Welding Generator | ||||
---|---|---|---|---|
AMP. | Welding Rod (NO./ MM) | Domestic Supply | H.P. | Cylinder |
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW / 1230 V/60 V | 12 HP | Single |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW / 1230 V/60 V | 14 HP | Single |
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW / 1230 V/70 V | 24 HP | Double |
AC Current Welding Alternator
AMP. | Welding Rod(NO./ MM) | Domestic Supply |
---|---|---|
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW/230 V |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW/230 V |
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW/230 V |
Specification
Single Phase 230 V 50 Hz 1.0 PF 1600 RPM Water Air Cooled | |||||||
---|---|---|---|---|---|---|---|
KVA | KW | H.P | AMP | Bore | Cylinder | Flywheel Casting (Kg. | Net Wt. (Kg.) |
3 | 3 | 5 | 12 | 85 | Single | 34 Kg. | 140 Kg. |
4 | 4 | 6 | 16 | 85 | Single | 45 Kg. | 170 Kg. |
5 | 5 | 8 | 20 | 87 | Single | 48 Kg. | 200 Kg. |
6 | 6 | 10 | 24 | 95 | Single | 58 Kg. | 230 Kg. |
7.5 | 7.5 | 12 | 28 | 102 | Single | 64 Kg. | 255 Kg. |
8 | 8 | 12 | 36 | 114 | Single | 70 Kg. | 270 Kg. |
10 | 9 | 14 | 40 | 114 | Single / Double | 80 Kg. | 300 Kg. |
12.5 | 12.5 | 16 | 48 | 95 | Single / Double | 70 Kg. | 350 Kg. |
15 | 14 | 24 | 56 | 102 | Double | 70 Kg. | 400 Kg. |
20 | 18 | 28 | 64 | 114.3 | Double | 80 Kg. | 450 Kg. |
25 | 22 | 32 | 67 | 116 | Double | 100 Kg. | 500 Kg. |
Three Phase 415 V 50 HZ 0.8 PF 1600 RPM Water Air Cooled
KVA | KW | H.P | AMP | BORE | Cylinder | Flywheel Casting (Kg. | Net Wt. (Kg.) |
---|---|---|---|---|---|---|---|
6 | 5 | 10 | 8 | 87 | Single | 48 Kg. | 240 Kg. |
7.5 | 7.5 | 12 | 10 | 95 | Single | 58 Kg. | 265 Kg. |
8.5 | 8.5 | 12 | 11 | 102 | Single | 64 Kg. | 280 Kg. |
10 | 9.5 | 14 | 13 | 114 | Single / Double | 70 Kg. | 310 Kg. |
12.5 | 12.5 | 16 | 16 | 114 | Single / Double | 80 Kg. | 360 Kg. |
15 | 14.5 | 24 | 23 | 102 | Double | 70 Kg. | 410 Kg. |
20 | 18.5 | 28 | 26 | 114 | Double | 80 Kg. | 460 Kg. |
25 | 22 | 32 | 67 | 116 | Double | 100 Kg. | 510 Kg. |
Specification
AC Welding Generator | |||||
---|---|---|---|---|---|
AMP. | Welding Rod (NO./ MM) | Domestic Supply | H.P. | Cylinder | |
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW / 1230 V/60 V | 12 HP | Single | |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW / 1230 V/60 V | 14 HP |
|
|
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW / 1230 V/70 V | 24 HP | Double |
AC Current Welding Alternator
AMP. | Welding Rod (NO./ MM) | Domestic Supply |
---|---|---|
250 | 8 to 12 (2.5 to 4.0) | 2.5 KW/230 V |
300 | 8 to 12 (2.5 to 4.0) | 5.0 KW/230 V |
400 | 6 to 12 (2.5 to 5.0) | 4.0 KW/230 V |
Air Cooled Diesel Generator is designed by us for offering high performance in high stress conditions. Various components are provided in the Air Cooled Diesel Generator to facilitate smooth working. Moreover, the Air Cooled Diesel Generator is made available in diverse specifications that meet the industry standards. Equipped With :
We are main supplier of this product.