Our Product / Services
We offer the best product range of Antibiotic Zone Reader, Automatic Counter, Microprocessor Control Stability Chamber, Hemoglobin Meter and Digital Turbidity Meter.
ANTIBIOTIC ZONE READER :P-A6
Antibiotic Zone Reader :The Antibiotic zone reader provides a rapid accurate method for determining the strength of antibiotic materials by measuring the diameter of an inhibited zone in petri dish.This zone reader measures the diameter of the inhibited zone to 0.02mm with the range of 0 to 35mm. It works on 220V AC 50Hz.
Additional Information:
Product Details:
Brand | Teknik |
Application | Laboratory |
Stability Chamber Microprocessor Control are microprocessor controlled chambers with soft touch keyboard for fast and accurate setting of various parameters. Just set the temp., humidity & time and the system runs automatically. All the parameters are digitally displayed and reproducible.
Special Features:
Additional Features:
Technical Data:
Capacity | Temperature Range |
170 lit. / 6 cft | 5C to 60C 1.0C |
285 lit. / 10 cft | 5C to 60C 1.0C |
340 lit. /12 cft | 5C to 60C 1.0C |
170 lit. / 6 cft | Ambient to 70C 1.0C |
285 lit. / 10 cft. | Ambient to 70C 1.0C |
340 lit./ 12 cft | Ambient to 70C 1.0C |
Optional:
Additional Information:
Display | Array of 10 LEDS in line |
Sample Size | 1 -50 mg of water |
K.F. Dispensing Resolution | 0.05 ml |
Indication | RUN ADD ENDDisplay in Auto Mode |
Detection | Current Sensing byelectronic control. |
K.F. Flow | Highly sensitive solenoid control volve for automatic control of K.F. Reagent. |
Measuring Electrode | Dual Platinum Electrode. |
Titration Cell | Air tight 200 ml glass vessel. |
End Point Delay | 30 seconds |
Buzzer | Yes |
Timer | Adjustable Timer |
Stirrer | Variable speed magnetic stirrer with On/Off control. |
Burette | Pressure filling auto zero burette with 0.05 ml resolution |
Power | 230V 10% AC 50 Hz |
ACCESSORIES | * Burette (Clear Glass) 10ml, * Reservoir Bottle 500ml, * Rubber Bellow for Pumping Air * Titration Cell 200 ml * Dual Platinum Electrode, * Teflon Coated Magnetic Stirring Capsule, * Nozzle, * Moisture Trap with Rubber Tubing, * Instruction Manual. |
Fitted with automatic 3 Digits LED Digital Display. Counting plate with illuminated standard wolfhugel ruling ensures clearly differentiated and sharply defined colonies. Each touch of making pencil in the petri dish increment the colony count by '1' and the glowing LED Display depicts the total colony count. Maximum colony Count possible upto 999. Provided with a manual reset of digital display, ON/OFF Switch, counting plate, 100 mm. dia lens, cord and plug. To work on 220V A.C.
Display | 3 LED |
Range | 0 to 1000 Mhos/cm 5 Range |
Accuracy | 1% FS 1 Digit |
Power Requirement | 230V AC |
Complete with Operation Manual & Dust Cover. | |
Spare | Conductivity Cell 1./0.5/0.1 |
Display | 3 LED |
Range | 0 to 20.0 ppm |
Resolution | 0.1 ppm |
Accuracy | 0.2 ppm |
Power Requirement | 220V AC |
Complete with Instruction Manual & Dust Cover
No. of Filters | Na & K | (Ca & Li optional) |
Range | Na : 0-200 meq/l K : 0-100 meq/l |
Ca:0-2 meq/l Li: 0-10 meq/l |
Sensitivity | Na : 5 ppm K : 5 ppm |
Ca:10 ppm Li : 10 ppm |
Read out | Dual 2½ digit bright LED Display | |
Accuracy | ± 2% upto 100 meq/l ± 5% above 100 meq/l |
|
Repeatability | ± 2 Count. | |
Detector | Silicon Photodiode | |
Filters | Narrow band interference glass filters | |
Nebulizer | Black bakelite, axial flow type | |
Flame System | LPG and dry oil free air | |
Warmup time | 10 minutes | |
Power | 230V ±10% AC 50 Hz | |
Compressor Unit | ||
Air Supply | By oil free mini compressor unit with pressure regular | |
Combustion | LPG controlled by precision regulator | |
Power | 230V±10%AC50Hz | |
Accessories | instrument with Na & K Filters instruction Manual | |
* Dust Cover *Chimney *Air and Gas Tubing Along with Clam |
Display | 3 Digit, Bright LED. |
Display Mode | O.D. And 3 Concentration Modes Ci, C2, C3. |
Zero Adjustment | Automatic (Without Knob rotation). |
Accuracy | +0.02 O. D. |
In built memory to retain last K factor for concentration even after power loss.
Fluoro Sensitivity | Full scale deflection obtained with 1 ppm quinine sulphate in 0.1 N sulphuric acid (primary Wavelength 360 nm). |
Display | 3 digit bright red seven segment LED display. |
Excitation Source | 12V, 50W Tungsten Halogen Lamp. |
Sensitivity Range | Adjustable in 4 ranges |
Display | 16 x 2 Alphamumeric display. |
Range | 0 to 20 ppm. |
Resolution | 0.1ppm. |
Calibration | Manual. |
Sensor | Amperometric DO Probe (Gold, Silver membrane Type). |
Accuracy | 0.1 ppm. |
Temperature | Manual. |
Compensation | 5 to 50C. |
Power | 220 v ac 50 hz. |
Display | 16X2 Lines LED Display. |
Measuring Rang | 0-40 gm/di of HB. |
Zero Adjustment | Automatic. |
Dilution ratio | 1.251. |
Key Board | Soft touch 4 days. |
Calibration | Automatic. |
Wavelength | 530 nm. |
Detector | High sensitive silicon photodiode. |
Display | 16 x 2 Alphanumeric LCD Display. |
Measuring range | 10 ppm to 100% of moisture. |
K. F. Dispensing | Highly sensitive motorized depensing system. |
KF Factor | In built automatic KF Titer Factor |
Calibration | calculation facility. |
Dispensing pump | Through keyboard 24 keys soft touch, membrane type. |
Stirrer | in buit magnetic stirrer with control. |
MOISTURE CONTENT CALCULATION (AUTOMATIC) |
Display | 16X2 Lines Alfa Numeric. |
Rang | 2 ranges 0 to 200 & 200 to 1000 Jtu/ntu. |
Accuracy | 3% of Full Scale Deflection in 0-1000 Jtu/ntu. |
Sample System | 30 mm Clear Glass Cuvettes. |
Light Source | 6.8 Volt, 0.3 Amps Tungsten Lamp. |
In built memory to retain both range standard solution and last set value even after power loss.
A lightweight pocket sized pH tester providing fast and accurate reading on alarge liquid crystal display.
Range | 0 to 14pH |
Resolution | 0.1pH |
Accuracy | +/- 0.1 pH |
Weight | 85gm |
Display | 3 LED |
Range | 0-14 pH01999mV |
Resulation | 0.01 pH1mV |
Temperature | |
Compensation | Automatic |
Power Requirement | 220V AC |
Display | 3 LED |
Range | 0 to 1000 Ppt 5 Range |
Accuracy | 1% FS 1 Digit |
Power Requirement | 220 V AC |
Complete with Operation Manual & Dust Cover.
Measurement Range | -45 +45, -120 Z + 120 Z |
Minimum Reading | 0.001 Z and 0.01 Z |
Accuracy | +(0.01 Z +Measurement value 0.05 %) +(0.03 Z+ Measurement value 0.05 %) |
Repeatability (Sta. Deviation) | < 0.00 |
Mini. sample transmittance | 1% |
Salient Features: