1 Products availableOur product range contains a wide range of Dissolved Oxygen Sensor, Conductivity Flow Cell Sensor, Valve Retraction sensor, On Line Water Hardness and Dissolved Oxygen Measurement
MicroSet Instrumentation & Controls reserves the right to make changes to this data sheet or the product without notice, as part of our policy of continued developments and improvements. | ||
This sensor model is designed for use with the insertion/retraction assemblies. The sensor body, with integral bulb guard and anti-blowout restraint, is molded from chemical-resistant materials and the reference junction is porous Teflon.
We are an eminentManufacturer, Exporter, WholesalerandSupplierofAutomationandInstrumentation Products. These products are technologically advanced and are known for their durability and efficient performance.We offer Dissolved Chlorine Sensors.
Special Features
No Reference electrode needed
Available in fully submersible and water proof format
Solid state sensors
Ideal for unskilled operatives
No filling solution required
Virtually unbreakable
Can be left dry for long periods
Long lifetime
The ProcessProbe D.O. sensor has been designed for use in any process streams or wastewater application.The body is machined from CPVC with integral 3/4"
NPT threads for easy installation. It also has a built-in thermistor for automatic temperature compensation. The dual-layer membrane is reinforced with stainless steel mesh. This mesh helps the membrane resist damage from particulates in the process stream extending the longevity of the sensor. The modular design of the membrane assembly makes regular maintenance simple and fast.
Specifications
Temperature Range 0 - 80 CMaximum Pressure AtmosphericResponse Time 98% in 60 seconds at 25 CSensor Body CPVCMembrane PTFE/Silicone reinforcedwith stainless steel mesh0-ring seals Silicone rubberStandard Cable Length 10 ft.
MICROSET series Micro-CD-112 is Conductivity sensor designed for fast, easy and trouble free start up. These are ideal for measuring the concentration of dissolved solids in water. They are provided with an accurate pre-determined factory calibration constant.Rugged design and corrosion resistant material keep electrode spacing and surface area constant so cell constant remain stable for long period. Durability of material and high resistance to corrosion ensures the long life and require low maintenance.
Features:
Available with 10/1/0.1/0.01 Cell constants
Temperature Compensation through PT 100 sensor
System Accuracy 2% F.S.
Measure Conductivity and Total Dissolved Solids in water
Flow through assembly in SS 316
Lengths are tailored for use with a Tri-Clover #7MP TEE, position sensor horizontally.
SPECIFICATION : | |
Max Pressure / Temp. Rating |
: 100 PSIG @120°C |
Wetted Materials |
: Insulator - FDA approved DuPont PTFE Teflon |
O-rings | : FDA approved Parker EJ150-75 (3077) EPDM |
Electrodes | : 316L Stainless Steel |
Cell Constant | : 0.01 / 0.05 / 0.1 / 1.0 / 10.0 |
Connections |
: Process Fitting - #16AMP solid end cap by Tri- Clover. |
Temperature Compensation |
: 3KΩ NTC Thermistor or Pt1000 |
Amperometirc Dual Electrode System with Replacement Membranes.
Severn Series for measurements when surfectants present.
Gold Cathode, Silver/Silver Halogenid Anode.
One and four series temperature range 45C.
Severn series temperature range 55C.
4 Pole Sensors | ||
Range: | OZ1N | : 0.00 – 20.00 ppm |
OZ1H | : 0.000 – 1.000 ppm | |
OZ7N | : 0.00 – 20.00 ppm | |
OZ7H | : 0.000 – 1.000 ppm | |
Resolution | OZ1N | : 0.01 ppm |
OZ1H | : 0.001 ppm | |
OZ7N | : 0.01 ppm | |
OZ7H | : 0.001 ppm | |
pH Range | CD4N | : 1 – 14 pH |
CD4H | : 1 – 14 pH | |
CD7N | : 2 – 11 pH | |
CD7H | : 2 – 11 pH |
2 Pole Sensors for 4-20mA Instruments |
||
Range: |
CL4.1MA0.5 | : 0 – 0.5 ppm |
OZ1MA2 | : 0.00 – 2.00 ppm | |
OZ1MA10 | : 0.0 – 10.0 ppm | |
OZ7MA0.5 | : 0.0 – 0.5 ppm | |
OZ7MA2 | : 0.00 – 2.00 ppm | |
OZ7MA5 | : 0.00 – 5.00 | |
OZ7MA10 | : 0.0 – 10.0 ppm | |
Resolution | OZ1MA0.5 | : 0.01 ppm |
OZ1MA2 | : 0.01 ppm | |
OZ1MA10 | : 0.1 ppm | |
OZ7MA0.5 | : 0.01 ppm | |
OZ7MA2 | : 0.01 ppm | |
OZ7MA5 | : 0.01 ppm | |
OZ7MA10 | : 0.1 ppm | |
pH Range | : 2 – 11 pH |
These sensors are designed for rugged service in submersion or on-line applications.The reference cell features a Double Junction design for extended service life in harsh applications.The body, with integral pipe threads, is molded from chemical-resistant Ryton (PPS) and the reference junction is porous Teflon or ceramic. Built-in temperature compensators are available. Optional sensor guards on the front of the sensor protects the sensor tip from impact. Sensor also available in ORP (Redox) version.
Specifications
pH Range 0 -14 pHORP Range + 5000 mVTemperature Range 0 - 105CMax. Pressure/Temp 150 psig at 100CReference Ag-AgCIWetted Materials Ryton, Teflon, GlassStd. Cable Length 10 Feet
Maximum Flow Rate:10 ft. (3 m) per second
Output Impedance:
< 250 megohms at 25 C
Chemical-resistant Wetted MaterialsThese high quality sensors are constructed of corrosion-resistant wetted materials including Rytorr, Teflon and glass.
Coaxial Porous Teflon Reference JunctionThe large annular junction resists fouling. Also, the sealed, double-junction reference electrode is highly resistant to poisoning.
Options Include:Built-in temperature compensationBuilt-in solution groundCustom cable lengthsChoice of cable connectors
Suitable for High Temperature ApplicationsCompatible With Most pH and ORP Analyzers
The SP Series ProcessProbe electrodes are available for pH and ORP measurements. The SP Series electrodes are 12 mm x 120 mm with threaded Pg13.5 cap. These dimensions make them compatible with many pre-existing housings found in industrial and waste treatment applications. Like all ProcessProbes, these electrodes are designed to work with Broadley-James transmit- ters and most other brands of existing instruments and cables.
The Double Junction Reference system used in all Broadley-James ProcessProbes reliably prevents process contaminants from fouling the reference. Since the reference is sealed, there is no electrolyte maintenance required.
The SP100 has a polymer body intended for use in applications up to 80 C and 4 bar (58 psig). This sensor may be a more economical alternative for low temp and low pressure industrial applications.
We are an eminentManufacturer, Exporter, WholesalerandSupplierofAutomationandInstrumentation Products. These products are technologically advanced and are known for their durability and efficient performance.We offer Dissolved Chlorine Sensors.
Application:Free Chlorine, Inorganic ChlorineCannot measure with Cyanuric Acid present
Amperometric Two and Three electrode systems with replacement membranes.
30/40 L/h Flow rate required.
1 Bar permissable pressure
Single point calibration
Sample must be free of surfactants
With the exception of the 4-20mA sensors, where the length is 220mm, the sensors have a length of 175mm and a diameter of 25mm, with plug adaptor connection.
They are designed to fit into the available flow cells.
The low current produced by the sensors is electronically amplified in the measurement cell.
No zero point calibration is necessary, and measurements can be taken in pressure up to 1 BAR.
The sensors are temperature compensated, and will operate in the range 0 to 45 degrees C (for the 7 Series, 0-55).
The water has to be flowing to obtain a reading, which is why flow cells are recommended.
Changes to the minimum flow rate will only slightly affect the measurement signal.
Surfactants should not be present in the water being measured (does not apply to the 7 Series probes).
For the dual electrode system, the measurement cell is made of gold, and the counter and reference electrodes of silver with silver halogenid coating. A bias voltage (polarisation) is applied between the two electrodes.
For the potentiostatic 3 electrode system, the measurement electrode is made of gold, the reference electrode is made of silver with a silver halogenid coating, and the counter electrode of stainless steel.
Handling, commissioning and service are extremely easy. The electrode system has a very long working life, with just the membrane cap subject to wear and tear. This needs to be replaced every year. However, maintenance costs are very low.
The time needed to polarise most of the probes is less than 2 hours.
No zero point calibration is necessary, and it is only necessary to have a single point calibration, only a slope test is required.
Because the flow dependence is so low, various in-line probe housings can be used, and it is possible to fit "in-line".
For most of the probes it is possible to operate up to 1 Bar (higher on request), and this enables the water to be easily returned.
Temperature compensation is integrated in every probe.
90% of the final value of the measurement can be reached in less than 2 minutes for most measurement probes.
Long term stability is excellent, slope loss is approximately 1% per month.