Our Products
Transmitter Device
2 Products availableElectric Fittings And Components
2 Products availablePH Meter
2 Products availableLimit Controller
2 Products availableConductivity Meter
1 Products availableGas Analyzers
1 Products availableWall Mounts
1 Products availableWe offer a complete product range of PH Sensor Flow Cell, Temperature and Air Velocity Transmitter and PH Sensor Housing
MicroSet Instrumentation & Controls reserves the right to make changes to this data sheet or the product without notice, as part of our policy of continued developments and improvements. | ||
NOTE: * For IP-65, Need Proper Mounting, Installation & Fitting Of Cable Glands
MicroSet Instrumentation & Controls reserves the right to make changes to this data sheet or the product without notice, as part of our policy of continued developments and improvements.
Range | 0-14 pH | 0-150c |
Resolution | 0.01 digit | 1c |
Accuracy | 0.1pH +/- I digit of reading | 1c |
Dual Display | Upper for pH (Red LED) & Lower for Temperature (green LED) | |
Temp. Compensation | 0 - 150°C Manual OR Auto (PT-100) (Optional) | |
Input Impedance | 10 Ohms | |
Calibration | 3 point Auto calibration 7.0; 4.0; 9.2 | |
Error Indication | Out Off Buffers Range. (B) Slope Error | |
Control Setting | 2 set point (High & low) | |
Output | 4-20mA DC / Modbus 485 (Optional @Extra Cost) | |
Controlling Output | 1 Or 2 Changeover relay of Potential Free Contacts Of 5 Amp | |
Environment | 5 to 50°C | |
Supply | 220VAC +/- 10%, 50 Hzs | |
Size | 170 x 130mm (Gray Color ABS Housing, Wall Mount, IP 65 Rating) |
These DynaProbes are designed for in-line or submersion applications. The sensor body threads directly into a tee or end of a pipe and is molded from chemical-resistant Ryton.
MicroSet Instrumentation & Controls reserves the right to make changes to this data sheet or the product without notice, as part of our policy of continued developments and improvements. | ||
MicroSet Instrumentation & Controls reserves the right to make changes to this data sheet or the product without notice, as part of our policy of continued developments and improvements. |
Range | 0-14 pH | 0-150c |
Resolution | 0.01 digit | 1c |
Accuracy | 0.1pH +/- 1 digit of reading | 1c |
Dual Display | Upper for pH (Red LED) & Lower for Temperature (green LED) | |
Temp. Compensation | 0 - 150°C Manual OR Auto (PT-100) (Optional) | |
Input Impedance | 10 Ohms | |
Calibration | 3 point Auto calibration 7.0; 4.0; 9.2 | |
Error Indication | Out Off Buffers Range. (B) Slope Error | |
Control Setting | 2 set point (High & low) | |
Output | 4-20mA DC (Optional) | |
Controlling Output | 1 Changeover relay of Potential Free Contacts Of 5 Amp | |
Environment | 5 to 50°C | |
Supply | 220VAC 4-/- 10%, 50Hzs | |
Size | 96X 96X100mm (Gray Color ABS Housing, Panel Mounting) |
Key Point:
|
Salient Features:
On-Line measurement.
2 wire system.
4-20 mA DC output.
Auto / Manual temperature compensation.
Simple Operating interface with basic pictographs.
Easy installation with per Assembly empty Enclosure & Plug in terminal.
Online Indication through LCD Display.
Protection Class IP- 65.
MicroSet seriesMicro- CT 211Tare Conductivity transmitters used for various industrialapplications. It can accept input from conductivity electrode of cell constant 0.01 / 0.1 / 1 &conductivity signal is transmitted in the form of electrical 4-20 mA signal. The on-lineconductivity indication is provided through LCD. Span/Zero adjustments are easilyaccessible. |
Technical Specifications |
| |||||
|
TECHNICAL SPECIFICATION | |
Type of Input | From DO Electrode (Galvanic/Poloragrahic) |
Type of Output | 4 - 20 mA DC, 2 wire Isolated |
Display | COG Display 128 X 64 |
Calibration Range | Factory Calibrated |
0 Temperature Compensation | Auto / Manual through RTD, Pt 100 sensor for 0-150˚C |
Accuracy | +/- 1% F. S. |
Isolation | 1.4 KV between Input, Output & Power Supply |
Power Supply | 24 V DC, External |
Power Consumption | < 50 mW |
Response Time | < 500 mSec |
0 Temperature Coefficients | +/- 0.01% per ˚C |
Enclosure | IP-65 |
Dimensions | 135 (H) x 182 (W) including cable gland x 170 (D) in mm approx. |
Electrical Connections | 3/4" ET |
Mounting | 2" Pipe Mounting |
Weight | 1 kg |
Operating Conditions | Temperature -20 to 75˚C / Humidity 5 to 95% non condensing |
Storage Temperature | -22 to 176˚F (-30 to 80˚C) |
Housing | Cast Aluminium with epoxy coating NEMA 4X (IP-65) |
Digital Communication | HART |
Seals into the twist-lock housing adapter via dual o-rings for in-line measurements. The body is molded from chemical-resistant Ryton (PPS) and the reference junction is porous Teflon. | |
FEATURE Advanced Embedded Microcontroller based designAvailable in Panel type & Field type and Flame proof & Weather proof versionEasy front key calibration3 digit, 14mm high intensity red LED display |
MICROSET Series Micro PH-211T is pH/ ORP Transmitter used for various industrial applications. It can accept input from pH / ORP Electrode & pH/ ORP signal is transmitted in the form of electrical 4-20mA signal. The on-line pH/ ORP indication is provided through LCD. Span/Zero adjustments are easily accessible. These transmitters are suitable for any make of Electrode.
FEATURE
On-line Measurement
On-line Indication through LCD Display
2 wire system
Simple Operating interface with basic pictographs
4-20 mA DC output
Easy installation
Auto/ Manual Temperature Compensation
INTRODUCTION
It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for R.O plant or D.M plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size.
The FF86 series air velocity transmitters were developed to obtain accurate measuring results over a wide range of velocities and temperature. High-quality hot film sensor elements based on cutting-edge thin film technology ensure maximum sensitivity, even at lowest mass flows. At the same time, the innovative probe design produces reliable measuring results at high flow velocities of up to 40m/s (8000ft/min). The integrated temperature compensation minimizes the temperature cross-sensitivity of the FF86 series which, combined with the robust mechanical design, allows it to be used at process temperatures between-40 to 120C (-40 to 248f). In addition to air velocity & temperature values, the transmitter calculates the volumetric flow rate in m3/min or ft3/min. the cross section of the duct needs to be determined for this purpose and the volumetric flow rate can displayed and directed to one of the analogue outputs. The configuration software included in the scope of supply allows choosing the appropriate output parameter and freely scaling the display range & signal level of the two analogue outputs. In addition user-friendly calibration of the air velocity & temperature and the adjustment of key parameters (e.g. response time of the velocity measurement, low flow cutoff points, etc.) are supported as well. | ||
An optional illuminated display with two control buttons integrated in the cover is available. In addition, this enables changes of the configuration to be made directly on the unit. The FF86 series can be used to measure the velocity of other gasses as well, although a correction has to be applied to the unit at the factory.
|
Measuring value | ||
Air velocity | ||
Working range | 0...2m/s (0...400ft/min) 0...10m/s (0...2000ft/min) 0...40m/s (0...8000ft/min) |
|
Accuracy "in are at 25°C (77°f)" | 0.06...2m/s (12...400ft/min) | ±0.03m/s /6ft/min |
At 45% RH & 1013 hPa 0.2... | 0.15...10m/s (30...2000ft/min) 40m/s (40...8000ft/min) |
±(0.10m/s/ 20ft/min +1% of measuring value) ±(0.10m/s/ 20ft/min +1% of measuring value) |
Uncertainty of factory calibration | ± (I 96 of measuring value, min. 0.015 m/s (3 ft/min)) | |
Temperature dependence electronic | Typ. -0.005% of measuring value /°C | |
Temperature dependence probe | ± (0.1 % of measuring value/°C) | |
Dependence | Of angle of inflow: Of direction of inflow |
<3% for a < 20° <3% |
Response time | ||
Temperature working range | Probe: Probe cable: Electronic: Electronic with display: |
-40...120 °C (-40...248 °F) -40...105 °C (-40...221 °F) -40...60 °C (-40...140 °F) -30...60 °C (-22_140 °F) |
Accuracy at 20 °C (68 °F) | ±0.5 (±0.9 °F) | |
Temperature dependence | Typ. -0.01 °C /°C | |
electronics Response time τ | 10s |