Our Products
Laboratory Apparatus
2 Products availableMedical Equipment & Supplies
2 Products availableExternal Fixators
1 Products availableBolts
1 Products availableHanging Hooks
1 Products availableOur product range contains a wide range of tibia nails, BROAD LC DCP PLATES, NARROW LC DCP PLATES, NARROW DCP PLATES and BROAD DCP PLATES
BROAD LC-DCP PLATES FOR 4.5MM SCREWS
CODE NO. | DESCRIPTION | |
745.010105 to010118 | Holes: 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17 & 18 | |
Fixation with 4.5mm & 6.5mm screws. Indication : Used as a tension band plate on the femur and for humeral pseudarthrosis (not intended for tibia). Use broad plates with 6 Or 7 Holes in exceptional cases only. E.g. on the humerus. LC-DCP = Limited Contact Dynamic Compression Plate | ||
Technical Specification: | ||
NARROW LC-DCP PLATES FOR 4.5MM SCREWS
CODE NO. | DESCRIPTION | |
745.020104 to020116 | Holes : 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 & 16 | |
Fixation with 4.5mm & 6.5mm screws. Indication : Used as neutralisation & tension band plate on the tibia. LC-DCP = Limited Contact Dynamic Compression Plate | ||
Technical Specification: | ||
NARROW DCP PLATES FOR 4.5MM SCREWS
CODE NO. | ||
745.040103 to040118 | ||
Fixation with 4.5mm & 6.5mm screws. Indication : Used as neutralisation & tension band plate on the tibia (not intended for femur). Use plates with 2, 3 & 4 holes in exceptional cases only. DCP= Dynamic Compression Plate With Spherical Gliding Principal. | ||
Technical Specification: | ||
BROAD DCP PLATES FOR 4.5MM SCREWS
CODE NO. | DESCRIPTION | |
745.030105 to030118 | ||
Fixation with 4.5mm & 6.5mm screws. Indication : Used as a tension band plate on the femur and for humeral pseudarthrosis (not intended for tibia). Use broad plates with 6 Or 7 Holes in exceptional cases only. E.g. on the humerus. DCP = Dynamic Compression Plate With Spherical Gliding Principal. | ||
Technical Specification: | ||
STRAIGHT RECONSTRUCTION PLATES FOR 4.5MM SCREWS
CODE NO. | ||
745.050103 to050122 | ||
Fixation with 4.5mm & 6.5mm screws. Indication : These are mainly used in Pelvic and Acetabular fractures. | ||
Technical Specification: | ||
"T" PLATES FOR 4.5MM SCREW
CODE NO. | ||
745.070103 to070112 | ||
Fixation with 4.5mm & 6.5mm screws. Indication: These plates are mainly used for Lateral / Medial Tibial Plateau fractures, Distal Medial Tibial fractures & Proximal Humeral fractures. | ||
Technical Specification: | ||
"L" BUTTRESS PLATES 4.5MM SCREWS (LEFT)
CODE NO. | ||
745.090103 to090110 | ||
Fixation with 4.5mm & 6.5mm screws. Indication : These plates are mainly used for Lateral / Medial Tibial Plateau fractures & Proximal Humeral fractures. | ||
Technical Specification: | ||
CONDYLAR BUTTRESS PLATE FOR 4.5MM SCREWS(LEFT)
CODE NO. | ||
745.100105 to100115 | ||
Fixation with 4.5mm & 6.5mm screws. Indication : These plates are mainly used in the comminuted supracondylar fractures. These are also used to contour the lateral aspect of distal femoral cortex. | ||
Technical Specification: | ||
COBRA HEAD PLATE FOR 4.5MM SCREWS
CODE NO. | ||
745.130107 to130113 | ||
Fixation with 4.5mm cortex screws. Indication : This plate is mainly used for Hip Arthrodesis. | ||
Technical Specification: | ||
PROXIMAL MEDIAL TIBIAL PLATE, ROUND HOLES (LEFT) FOR 4.5MM SCREWS
CODE NO. | ||
745.140905 to140915 | ||
Fixation with 4.5mm & 6.5mm screws. Indication : These plates are mainly used for Medial Tibial Plateau fractures. | ||
Technical Specification: | ||
PROXIMAL MEDIAL TIBIAL PLATE, ROUND HOLES (RIGHT) FOR 4.5MM SCREWS
CODE NO. | ||
745.141005 to141015 | ||
Fixation with 4.5mm & 6.5mm screws. Indication : These plates are mainly used for Medial Tibial Plateau fractures. | ||
Technical Specification: | ||
SMALL LC-DCP PLATES FOR 3.5MM SCREWS
CODE NO. | ||
735.010104 to010116 | ||
Fixation with 3.5 and 4.0mm screws.LC-DCP = Limited Contact Dynamic Compression Plate Indication : These plates are mainly used for fixation of Radius & Ulna fractures. | ||
Technical Specification: | ||
SMALL DCP PLATES FOR 3.5MM SCREWS
CODE NO. | ||
735.020102 to020112 | ||
Fixation with 3.5 and 4.0mm screws. Indication: These plates are mainly used for fixation of Radius & Ulna fractures. | ||
Technical Specification: | ||
ONE-THIRD TUBULAR PLATES FOR 3.5MM SCREWS
CODE NO. | ||
735.030102 to030112 | ||
Fixation with 3.5 and 4.0mm screws Indication : These plates are used to fix the fractures of fibula, metacarpal & metatarsals. | ||
Technical Specification: | ||
Technical Specification: |
CONDYLAR BLADE PLATES 95 FOR 4.5MM SCREWS
DHS BARREL PLATES (ROUND HOLE) SHORT BARREL - 25MM
CODE NO. | DESCRIPTION | |
4066.04 to 06 | 130 Holes : 4, 5 & 6 | |
4067.02 to 22 | 135 Holoes : 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 & 22 | |
Fixation with 4.5mm cortex screws. Indication: This plate is used to fix the fractures of Proximal Femur like Intertrochanteric, Sub-Trochanteric and Per-Trochanteric Region. | ||
Technical Specification : | ||
DHS BARREL PLATES (DCP HOLE) SHORT BARREL - 25MM
ixation with 4.5mm cortex screws. Indication : This plate is used to fix the fractures of Proximal Femur like Intertrochanteric, Sub-Trochanteric and Per-Trochanteric Region.
Technical Specification: |
TROCHANTERIC / CONDYLAR PLATES (DCP HOLES)
CODE NO. | ||
4210.02 to 20 | ||
Indication: This plate is used to fix the fractures of Proximal Femur like Intertrochanteric, Sub-Trochanteric and Per- Trochanteric Region and Femoral Condyle Region. | ||
Technical Specification: | ||