Performance Thori Mass Flow Controller Accuracy at calibration conditions after tare ±(2% F.S) Zero Shift and Span Shift ± 0.2% FS / °C Repeatability ± 0.5% Reading Long term drift 0.05% Full Scale / Year Operating Range / Turndown Ratio 0 : 25
Maximum Controllable Flow Rate 102% Full Scale Typical Response Time 100 ms Warm-up Time 70 ms to full scale accuracy Valve Leak Specifications Internal (leak through) 10-5 atm – cc/sec He External (leak out) 10-9 atm – cc/sec He
Operating Conditions Thori Mass Flow Controller Calibration Conditions 25°C, 14.696 psia Operating Temperature 0 to +50 ºCelsius Humidity Range (Non–Condensing) <90% Maximum Internal Pressure (Static) 100 PSIG 100 PSIG Proof Pressure 100 psig Vibration Nil. Mounting Attitude Sensitivity Yes. Valve Type Normally Closed Ingress Protection IP40 Wetted Materials Aluminium & Brass.
Communications / Power Thori Mass Flow Controller Digital Input / Output Signal Via 4-20 mA Analog Input / Output Signal 0-5 Vdc Optional. Electrical Connection Options 9-pin male D-sub (DB9) Supply Voltage 10 to 30 Vdc or Works On Loop Power. Supply Current 200 mA
Features Thori Mass Flow Controller
Notes.
Units calibrated with Air have built-in correction equations that allow you to use the gas select command to switch to Argon, Carbon Dioxide, Nitrogen, Oxygen, or Nitrous Oxide.
Note: PFC-CC-1000 units that are set to Carbon Dioxide or Nitrous Oxide are limited to a maximum flow rate of 750 sccm instead of 1000 sccm due to the correction factor equations used for these gases. Note: PFCL020 units that are set to Carbon Dioxide or Nitrous Oxide are limited to a maximum flow rate of 15 slpm instead of 20 slpm due to the correction factor equations used for these gases. Note: Units calibrated with Hydrogen or Helium can function only with that gas.
Model No Flow Range Min Flow Max Flow Accuracy PFC-CC-002 0 to 2 SCCM 0.1 SCCM 0 to 2 SCCM +/- 2 % PFC-CC-005 0 to 5 SCCM 0.1 SCCM 0 to 5 SCCM +/- 2 % PFC-CC-010 0 to 10 SCCM 0.1 SCCM 0 to 10 SCCM +/- 2 % PFC-CC-020 0 to 20 SCCM 0.1 SCCM 0 to 20 SCCM +/- 2 % PFC-CC-050 0 to 50 SCCM 0.1 SCCM 0 to 50 SCCM +/- 2 % PFC-CC-0100 0 to 100 SCCM 0.1 SCCM 0 to 100 SCCM +/- 2 % PFC-CC-0200 0 to 200 SCCM 0.1 SCCM 0 to 200 SCCM +/- 2 % PFC-CC-0250 0 to 250 SCCM 0.1 SCCM 0 to 250 SCCM +/- 2 % PFC-CC-0500 0 to 500 SCCM 0.1 SCCM 0 to 500 SCCM +/- 2 % PFC-CC-0750 0 to 750 SCCM 0.1 SCCM 0 to 750 SCCM +/- 2 % PFC-CC-1000 0 to 1000 SCCM 0.1 SCCM 0 to 1000 SCCM +/- 2 % PFC-L-002 0 to 2 LPM 0.1 LPM 0 to 2 LPM +/- 2 % PFC-L-005 0 to 5 LPM 0.1 LPM 0 to 5 LPM +/- 2 % PFC-L-010 0 to 10 LPM 0.1 LPM 0 to 10 LPM +/- 2 % PFC-L-020 0 to 20 LPM 0.1 LPM 0 to 20 LPM +/- 2 % PFC-L-050 0 to 50 LPM 0.1 LPM 0 to 50 LPM +/- 2 % PFC-L-0100 0 to 100LPM 0.1 LPM 0 to 100 LPM +/- 2 % PFC-L-0200 0 to 200LPM 0.1 LPM 0 to 200 LPM +/- 2 % PFC-L-0250 0 to 250LPM 0.1 LPM 0 to 250 LPM +/- 2 % PFC-L-0500 0 to 500LPM 0.1 LPM 0 to 500 LPM +/- 2 % PFC-L-0750 0 to 750LPM 0.1 LPM 0 to 750 LPM +/- 2 % PFC-L-1000 0 to 1000LPM 0.1 LPM 0 to 1000LPM +/- 2 %
Additional Information:
Payment Terms : T/T,
Packaging Details : One Material Per Box
Delivery Time : 1 Weeks
diesel flowmeter with lowest weight for custody transfer applications for decantation of tanker trucks to under ground tanks by gravity. he is looking for machine with accuracy rate 0.5%. flow meter has gravity transfer, variable flow and has robust design and is portable.
Additional Information:
Payment Terms : T/T
Delivery Time : Kindly Contact Us
Additional Information:
Payment Terms : T/T
Packaging Details : Wooden Box Commercial Packing
Delivery Time : Kindly Contact Us
Additional Information:
Payment Terms : T/T
Delivery Time : Kindly Contact Us
We are an eminent Manufacturer, Supplier and Exporter of Mass Flow Controllers from Maharashtra. The Mass Flow Controllers we make available eliminate gross errors of volumetric low measurement. We maintain a large stock of the Mass Flow Controllers in our spacious warehouse, to cater the bulk and urgent requirements of the buyers. The entire range of the Mass Flow Controllers is reasonably priced by us. Details
Specifications
Full scale range | 50, 100, 500 sccm 1, 5, 10, 30, 50, 86,100 slpm Or as Required Any Flowrate above 100slpm |
---|---|
Accuracy (includes non-linearity, hysteresis non-repeatability and thermal coefï¬cient to 45°C) | ±3% of full scale |
Thermal coefï¬cient (45°C to 50°C) | ±0.075% of full scale/°C |
Output - linear with ï¬ow | 4-20 mA |
Line pressure effect | 1% full scale/bar |
Working temperature | 15 to 50°C |
Working pressure | 0.5 to 5 bar (gauge) |
Burst pressure | 11 bar (gauge) |
Pressure drop at full scale | <0.025 bar |
Leak Integrity (to Helium) | < 1x10-9 mbar.l/s |
Power supply | 230 V AC or 24 V DC |
Dimensions | Might Change as Per Design and Model. |
Weight | Subject to Change as Per Model & Design. |
Gas connection | G¼ female thread or As Required . |
Connector | May Change. |
Flow path materials | Stainless Steel S304, S316 . |
Additional Information:
Payment Terms : T/T
Delivery Time : Kindly Contact Us