Post Buy Requirement

Other Products / Services

Our Complete range of products are Gravity Convection Oven, Mechanical Convection Oven, PID Controller Mechanical Convection Ovens and Sample Processor.

Glass Viscometer

Filling, measurement, and cleaning can be done without removal from constant temperature bath. Manufactured with permanently attached round metal holder or rectangular metal holder.
View Complete Details

Glass Capillary Viscometer

Cannon-Fenske Routine ViscometersUbbelohde ViscometersReverse Flow ViscometersSmall Volume (semi-micro or micro) ViscometersDilution ViscometersVacuum Viscometers

Viscometer

Material

ASTM / ISO

Specification

Cannon-Fenske Routine Viscometer

Cannon-Fenske  Routine

Transparent Newtonian  liquids, particularly    petroleum products or  lubricants

ASTM D 445 and ISO 3104 Specifications conform to ASTM D  446 and ISO 3105

Minimum sample volume 7 mL.
Require liquid bath depth of
203 mm

Zeitfuchs  Transparent

Transparent Newtonian  liquids

ASTM D 445 and ISO 3104,  Specifications conform to ASTM D  446 and ISO 3105

Filling, measurement, and cleaning can  be done without removal from constant  temperature bath. Manufactured with  permanently attached round metal  holder or rectangular metal holder

BS/U-Tube

Transparent Newtonian liquids

ASTM D 445 and ISO 3104  Specifications conform to ASTM D  446 and ISO 3105

Sample volume 7ml, 12ml & 23 ml
Require liquid bath depth of 280 mm

Ubbelohde Viscometer

Ubbelohde

Transparent Newtonian liquids

ASTM D 445 and D 446, and ISO  3104 and 3105

Measurement by suspended level principle

Cannon-  Ubbelohde
 Suspended level

Transparent Newtonian liquids jet and hydraulic lubricants

ASTM D 445 and ISO 3104
 Specifications conform to ASTM D 446  and ISO 3105

Especially suited for use at temperatures  above 93°C (200°F) or below –18°C  (0°F) Require no kinetic energy  corrections over 0.5 to 100 000  centistokes range. Viscometer constant  is same at all temperature

BS/IP/SL,  BS/IP/SL(S)

Transparent Newtonian liquids

ASTM D 445 and ISO 3104.  Specifications conform to ASTM D 446  and ISO 3105

Minimum sample volume 11 mL / 10 mL
Require liquid bath depth of 250mm /  230 mm

BS/IP/MSL

Transparent Newtonian liquids

ASTM D 445 and ISO 3104.  Specifications conform to ASTM D 446  and ISO 3105

Minimum sample volume 4 mL.
Require liquid bath depth of 305 mm

 

 

Viscometer

Material

ASTM / ISO

Specification

Reverse Flow Viscometers

Cannon-Fenske  Opaque

Dark Newtonian liquids

ASTM D 445 and ISO 3104

Can also be used to measure kinematic viscosity of liquid (cutback) asphalts and road oils at 60°C (140°F) in range of 30 to 6000 centistokes according to ASTM D 2170

Zeitfuchs Cross- Arm

Transparent and opaque Newtonian liquids

ASTM D 445 & ISO 3104.
Specifications conform to ASTM D 446 and ISO 3105

Also used to measure kinematic viscosity of liquid (cutback) asphalts and road oils at 60°C (140°F) and asphalt cements at 135°C (275°F) in the range of 30 to 6000 centistokes according to ASTM D 2170.

Can be filled and cleaned while in
constant temperature bath.

Supplied with permanently attached
round metal holder or rectangular metal holder.

BS/IP/RF U-Tube

Opaque Newtonian liquids

ASTM D 445 & ISO 3104.
Specifications conform to ASTM D 446 and ISO 3105

Minimum sample volume 7 mL.
Require liquid bath depth of 280 mm

Small Volume (semi-micro or micro) Viscometers

Cannon  Ubbelohde
 Semi-Micro

Small samples of
transparent Newtonian liquids

ASTM D 445 & ISO 3104.
 Specifications conform to ASTM D 446
 and ISO 3105

Minimum sample volume approximately
 1.0 mL.

Initial sample can be diluted to as much as 20 mL for intrinsic viscosity determination Require liquid bath depth of 240 mm

Cannon-Manning
 Semi-Micro
 (U-tube)

Small samples of
 transparent Newtonian
 liquids, including
 petroleum products or lubricants,

ASTM D 445 & ISO 3104. Specifications conform to ASTM D 446 and ISO 3105

Sample volume approximately 1.0 mL. Sizes 400 through 600 may require more sample. Require liquid bath depth of 200 mm

Cannon-Manning
 Semi-Micro Extra
 Low Change

Small samples of
 transparent Newtonian
 liquids, including
 petroleum products or lubricants,

ASTM D 445 and ISO 3104.
Specifications conform to ASTM D 446 and ISO 3105

For smaller sample volume of approx 0.5 mL Sizes 200 through 600 may require larger volume of sample

 

Viscometer

Material

ASTM / ISO

Specification

Dilution Viscometers

Cannon- 
 Ubbelohde

 Dilution

Transparent Newtonian  liquids

ASTM D 445 and ISO 3104  Specifications conform to ASTM D  446 and ISO 3105

For measurement of Intrinsic viscosity

Cannon-
 Ubbelohde
Four-
 Bulb Shear
 Dilution

Extrapolated to zero
shear  rate

 

 

For measurement of Intrinsic viscosity Provide Five-fold / Ten-fold range of  shear rates. Design gives extra  mechanical strength. Negligible kinetic energy correction

Vacuum Viscometers

Cannon-Manning
 Vacuum

Highly viscous materials  such as asphalt cement
 materials with viscosity  range of 0.036 to 80 000  poise

ASTM D 2171

Vacuum of 300 mm Hg is applied to small  arm with timing bulbs; two bulbs are  incorporated to extend viscosity range of  viscometer

Asphalt Institute
 Vacuum

Highly viscous materials  such as asphalt cement
 materials with viscosity  range of 0.036 to 80 000  poise

 

Vacuum of 300 mm Hg is applied to small  arm with graduated capillary

Cannon Modified
 Koppers Vacuum

Asphalts at 60°C (140°F)

ASTM D 2171

Applicable to materials with viscosity  range of 42 to 200 000 poise.
 Two-piece design, with sample reservoir  and calibrated capillary Vacuum of 300  mm Hg must be applied to top of  capillary tube.















































View Complete Details

Gravity Convection Oven

Durable powder-coated cold-rolled steel exterior.Double-wall aluminum interior with 1'-thick (2.5 cm) silica-based insulationThese economical gravity convection ovens are designed for the budget-conscious laboratory needing to perform basic drying and baking applications. Temperature is controlled via a bimetallic thermostat from ambient 5 to 210degC. All models feature a pilot light to indicate when the oven is in operation and a preset high temperature limit safety thermostat.

View Complete Details

Mechanical Convection Oven

Feature polyurethane foam and glass wool for superior heat insulationForced air circulation offers uniform temperature distribution.Audio and visual alarms warn of temperature variation, and utility failure.Easy-to-clean stainless steel chamber.

These mechanical convection ovens feature a double-walled chamber with glass wool and polyurethane foam (PUF) insulation. PUF insulation offers extremely effective and strong insulation properties that minimize heat loss and reduce energy costs. Stainless steel tubular heaters with stainless steel fins extend the ovens lifetime. Choose models with either mild steel powder-coated paint or stainless steel exterior construction. Outer metal door offers magnetic gasket and lock, and a full-length inner glass door allows inspection of oven chamber while minimizing heat loss.

View Complete Details

Viscosity Cup

These standards are furnished in a range of viscosities and temperatures which are of particular interest in asphalt viscosity determinations and the determination of the viscosities of polymers.
View Complete Details

Muffle Furnace

Autotune feature helps eliminate temperature overshoot.Energy efficient insulation keeps exterior safe to touch.These furnaces are available in three sizes and three controller options to meet your application requirements. All models have autotune feature which allows the furnace to perform better at a particular set point and load, eliminating temperature overshoot for a commonly used application. An optional RS-485 communications port is available to let you use these furnaces with your computer. RS-485 option is factory installedyou must order the RS-485 option at the same time you order your furnace.

The fully embedded heating elements maintain temperature uniformity. A door switch cuts power to the heating elements when the door is opened minimizing your exposure to hot temperatures and extending the life of the heating elements. Unique ceramic fiber insulation and double walled construction minimize exterior surface temperatures. The removable hearth plate prevents damage to furnace from spills.

Single Set Point Control Furnaces have two LED displays to simultaneously display actual and set point temperatures.

View Complete Details

Analog Mechanical Convection Incubators

Incubators are manufactured with 22-gauge steel. Powder-coated exterior provides scratch and stain resistance. The interior is easy-to-clean aluminum. See-through polycarbonate doors with positive latches allow you to conveniently monitor laboratory applications. All analog incubators use a hydraulic thermostat for control of temperature and a separate on/off switch. The digital incubators utilize a PID controller and digital temperature input and readout. Over-range safety thermostat with a red warning indicator light, and a five hour timer are also provided.

View Complete Details

Digital Mechanical Convection Incubators

Incubators are manufactured with 22-gauge steel. Powder-coated exterior provides scratch and stain resistance. The interior is easy-to-clean aluminum. See-through polycarbonate doors with positive latches allow you to conveniently monitor laboratory applications. All analog incubators use a hydraulic thermostat for control of temperature and a separate on/off switch. The digital incubators utilize a PID controller and digital temperature input and readout. Over-range safety thermostat with a red warning indicator light, and a five hour timer are also provided.

View Complete Details

PID Controller Mechanical Convection Ovens

These mechanical convection ovens heat up to a maximum temperature of 275C to save you valuable time in drying and aging applications. All models have a PID microprocessor controller that is easy to set and monitor making them perfect for a variety of uses in which precise control and good uniformity are important. Safety features include a built-in backup controller and a circuit breaker. Backup controller automatically takes over the control if the actual temperature reaches 5C above the set point. The circuit breaker protects the oven from power surges. The alarm indicator lets you know when the overtemperature value has been exceeded and the backup controller is in use.
View Complete Details

PID Controller Laboratory Mechanical Convection Ovens

Proportional-integral-derivative (PID) controller provides precise temperature control.Battery backup saves your last temperature settingexcellent for labs.where testing procedures are repeated.

These mechanical convection ovens heat up to a maximum temperature of 275C to save you valuable time in drying and aging applications. All models have a PID microprocessor controller that is easy to set and monitor making them perfect for a variety of uses in which precise control and good uniformity are important.

Safety features include a built-in backup controller and a circuit breaker. Backup controller automatically takes over the control if the actual temperature reaches 5C above the set point. The circuit breaker protects the oven from power surges. The alarm indicator lets you know when the overtemperature value has been exceeded and the backup controller is in use.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by Matrix Technochem from Thane, Maharashtra.
Post Buy Requirement

Our Products

We offer the best product range of Gravity Convection Oven, Mechanical Convection Oven, PID Controller Mechanical Convection Ovens and Sample Processor.

Glass Viscometer

Filling, measurement, and cleaning can be done without removal from constant temperature bath. Manufactured with permanently attached round metal holder or rectangular metal holder.
View Complete Details

Glass Capillary Viscometer

Cannon-Fenske Routine ViscometersUbbelohde ViscometersReverse Flow ViscometersSmall Volume (semi-micro or micro) ViscometersDilution ViscometersVacuum Viscometers

Viscometer

Material

ASTM / ISO

Specification

Cannon-Fenske Routine Viscometer

Cannon-Fenske  Routine

Transparent Newtonian  liquids, particularly    petroleum products or  lubricants

ASTM D 445 and ISO 3104 Specifications conform to ASTM D  446 and ISO 3105

Minimum sample volume 7 mL.
Require liquid bath depth of
203 mm

Zeitfuchs  Transparent

Transparent Newtonian  liquids

ASTM D 445 and ISO 3104,  Specifications conform to ASTM D  446 and ISO 3105

Filling, measurement, and cleaning can  be done without removal from constant  temperature bath. Manufactured with  permanently attached round metal  holder or rectangular metal holder

BS/U-Tube

Transparent Newtonian liquids

ASTM D 445 and ISO 3104  Specifications conform to ASTM D  446 and ISO 3105

Sample volume 7ml, 12ml & 23 ml
Require liquid bath depth of 280 mm

Ubbelohde Viscometer

Ubbelohde

Transparent Newtonian liquids

ASTM D 445 and D 446, and ISO  3104 and 3105

Measurement by suspended level principle

Cannon-  Ubbelohde
 Suspended level

Transparent Newtonian liquids jet and hydraulic lubricants

ASTM D 445 and ISO 3104
 Specifications conform to ASTM D 446  and ISO 3105

Especially suited for use at temperatures  above 93°C (200°F) or below –18°C  (0°F) Require no kinetic energy  corrections over 0.5 to 100 000  centistokes range. Viscometer constant  is same at all temperature

BS/IP/SL,  BS/IP/SL(S)

Transparent Newtonian liquids

ASTM D 445 and ISO 3104.  Specifications conform to ASTM D 446  and ISO 3105

Minimum sample volume 11 mL / 10 mL
Require liquid bath depth of 250mm /  230 mm

BS/IP/MSL

Transparent Newtonian liquids

ASTM D 445 and ISO 3104.  Specifications conform to ASTM D 446  and ISO 3105

Minimum sample volume 4 mL.
Require liquid bath depth of 305 mm

 

 

Viscometer

Material

ASTM / ISO

Specification

Reverse Flow Viscometers

Cannon-Fenske  Opaque

Dark Newtonian liquids

ASTM D 445 and ISO 3104

Can also be used to measure kinematic viscosity of liquid (cutback) asphalts and road oils at 60°C (140°F) in range of 30 to 6000 centistokes according to ASTM D 2170

Zeitfuchs Cross- Arm

Transparent and opaque Newtonian liquids

ASTM D 445 & ISO 3104.
Specifications conform to ASTM D 446 and ISO 3105

Also used to measure kinematic viscosity of liquid (cutback) asphalts and road oils at 60°C (140°F) and asphalt cements at 135°C (275°F) in the range of 30 to 6000 centistokes according to ASTM D 2170.

Can be filled and cleaned while in
constant temperature bath.

Supplied with permanently attached
round metal holder or rectangular metal holder.

BS/IP/RF U-Tube

Opaque Newtonian liquids

ASTM D 445 & ISO 3104.
Specifications conform to ASTM D 446 and ISO 3105

Minimum sample volume 7 mL.
Require liquid bath depth of 280 mm

Small Volume (semi-micro or micro) Viscometers

Cannon  Ubbelohde
 Semi-Micro

Small samples of
transparent Newtonian liquids

ASTM D 445 & ISO 3104.
 Specifications conform to ASTM D 446
 and ISO 3105

Minimum sample volume approximately
 1.0 mL.

Initial sample can be diluted to as much as 20 mL for intrinsic viscosity determination Require liquid bath depth of 240 mm

Cannon-Manning
 Semi-Micro
 (U-tube)

Small samples of
 transparent Newtonian
 liquids, including
 petroleum products or lubricants,

ASTM D 445 & ISO 3104. Specifications conform to ASTM D 446 and ISO 3105

Sample volume approximately 1.0 mL. Sizes 400 through 600 may require more sample. Require liquid bath depth of 200 mm

Cannon-Manning
 Semi-Micro Extra
 Low Change

Small samples of
 transparent Newtonian
 liquids, including
 petroleum products or lubricants,

ASTM D 445 and ISO 3104.
Specifications conform to ASTM D 446 and ISO 3105

For smaller sample volume of approx 0.5 mL Sizes 200 through 600 may require larger volume of sample

 

Viscometer

Material

ASTM / ISO

Specification

Dilution Viscometers

Cannon- 
 Ubbelohde

 Dilution

Transparent Newtonian  liquids

ASTM D 445 and ISO 3104  Specifications conform to ASTM D  446 and ISO 3105

For measurement of Intrinsic viscosity

Cannon-
 Ubbelohde
Four-
 Bulb Shear
 Dilution

Extrapolated to zero
shear  rate

 

 

For measurement of Intrinsic viscosity Provide Five-fold / Ten-fold range of  shear rates. Design gives extra  mechanical strength. Negligible kinetic energy correction

Vacuum Viscometers

Cannon-Manning
 Vacuum

Highly viscous materials  such as asphalt cement
 materials with viscosity  range of 0.036 to 80 000  poise

ASTM D 2171

Vacuum of 300 mm Hg is applied to small  arm with timing bulbs; two bulbs are  incorporated to extend viscosity range of  viscometer

Asphalt Institute
 Vacuum

Highly viscous materials  such as asphalt cement
 materials with viscosity  range of 0.036 to 80 000  poise

 

Vacuum of 300 mm Hg is applied to small  arm with graduated capillary

Cannon Modified
 Koppers Vacuum

Asphalts at 60°C (140°F)

ASTM D 2171

Applicable to materials with viscosity  range of 42 to 200 000 poise.
 Two-piece design, with sample reservoir  and calibrated capillary Vacuum of 300  mm Hg must be applied to top of  capillary tube.















































View Complete Details

Gravity Convection Oven

Durable powder-coated cold-rolled steel exterior.Double-wall aluminum interior with 1'-thick (2.5 cm) silica-based insulationThese economical gravity convection ovens are designed for the budget-conscious laboratory needing to perform basic drying and baking applications. Temperature is controlled via a bimetallic thermostat from ambient 5 to 210degC. All models feature a pilot light to indicate when the oven is in operation and a preset high temperature limit safety thermostat.

View Complete Details

Mechanical Convection Oven

Feature polyurethane foam and glass wool for superior heat insulationForced air circulation offers uniform temperature distribution.Audio and visual alarms warn of temperature variation, and utility failure.Easy-to-clean stainless steel chamber.

These mechanical convection ovens feature a double-walled chamber with glass wool and polyurethane foam (PUF) insulation. PUF insulation offers extremely effective and strong insulation properties that minimize heat loss and reduce energy costs. Stainless steel tubular heaters with stainless steel fins extend the ovens lifetime. Choose models with either mild steel powder-coated paint or stainless steel exterior construction. Outer metal door offers magnetic gasket and lock, and a full-length inner glass door allows inspection of oven chamber while minimizing heat loss.

View Complete Details

Viscosity Cup

These standards are furnished in a range of viscosities and temperatures which are of particular interest in asphalt viscosity determinations and the determination of the viscosities of polymers.
View Complete Details

Muffle Furnace

Autotune feature helps eliminate temperature overshoot.Energy efficient insulation keeps exterior safe to touch.These furnaces are available in three sizes and three controller options to meet your application requirements. All models have autotune feature which allows the furnace to perform better at a particular set point and load, eliminating temperature overshoot for a commonly used application. An optional RS-485 communications port is available to let you use these furnaces with your computer. RS-485 option is factory installedyou must order the RS-485 option at the same time you order your furnace.

The fully embedded heating elements maintain temperature uniformity. A door switch cuts power to the heating elements when the door is opened minimizing your exposure to hot temperatures and extending the life of the heating elements. Unique ceramic fiber insulation and double walled construction minimize exterior surface temperatures. The removable hearth plate prevents damage to furnace from spills.

Single Set Point Control Furnaces have two LED displays to simultaneously display actual and set point temperatures.

View Complete Details

Analog Mechanical Convection Incubators

Incubators are manufactured with 22-gauge steel. Powder-coated exterior provides scratch and stain resistance. The interior is easy-to-clean aluminum. See-through polycarbonate doors with positive latches allow you to conveniently monitor laboratory applications. All analog incubators use a hydraulic thermostat for control of temperature and a separate on/off switch. The digital incubators utilize a PID controller and digital temperature input and readout. Over-range safety thermostat with a red warning indicator light, and a five hour timer are also provided.

View Complete Details

Digital Mechanical Convection Incubators

Incubators are manufactured with 22-gauge steel. Powder-coated exterior provides scratch and stain resistance. The interior is easy-to-clean aluminum. See-through polycarbonate doors with positive latches allow you to conveniently monitor laboratory applications. All analog incubators use a hydraulic thermostat for control of temperature and a separate on/off switch. The digital incubators utilize a PID controller and digital temperature input and readout. Over-range safety thermostat with a red warning indicator light, and a five hour timer are also provided.

View Complete Details

PID Controller Mechanical Convection Ovens

These mechanical convection ovens heat up to a maximum temperature of 275C to save you valuable time in drying and aging applications. All models have a PID microprocessor controller that is easy to set and monitor making them perfect for a variety of uses in which precise control and good uniformity are important. Safety features include a built-in backup controller and a circuit breaker. Backup controller automatically takes over the control if the actual temperature reaches 5C above the set point. The circuit breaker protects the oven from power surges. The alarm indicator lets you know when the overtemperature value has been exceeded and the backup controller is in use.
View Complete Details

PID Controller Laboratory Mechanical Convection Ovens

Proportional-integral-derivative (PID) controller provides precise temperature control.Battery backup saves your last temperature settingexcellent for labs.where testing procedures are repeated.

These mechanical convection ovens heat up to a maximum temperature of 275C to save you valuable time in drying and aging applications. All models have a PID microprocessor controller that is easy to set and monitor making them perfect for a variety of uses in which precise control and good uniformity are important.

Safety features include a built-in backup controller and a circuit breaker. Backup controller automatically takes over the control if the actual temperature reaches 5C above the set point. The circuit breaker protects the oven from power surges. The alarm indicator lets you know when the overtemperature value has been exceeded and the backup controller is in use.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us