Post Buy Requirement
Manas Microsystem Pvt LTD

Manas Microsystem Pvt LTD

gstGST : 27AABCM2639R1ZX Verified Add Review

Flow Meters

Our product range contains a wide range of Electromagnetic Flow Meter, CNG Flow Meter, Food Grade Electromagnetic Flow Meter, Full Bore Type Electromagnetic Flow Meter and Gas Flow Totaliser

Electromagnetic Flow Meter

  • Brand Name Manas Microsystems
  • Operating Temperature HR: 0 – 90 ºC / PTFE: 0 – 150 ºC / PFA: 0 – 200 ºC / Neoprene: 0 – 90 ºC
  • Line Size DN 10 To DN 350
  • Accuracy ±0.5 % +-(1mm/sec) Of Actual Flow Rate Between 100 % To 10 % Of Calibrated Range
  • Liner Material HR, PTFE, PFA, Neoprene
  • Electrode MOC SS316, Hastalloy C, TAN, TI
  • Flange Standard ANSI / DIN / BS 10 E/BS 10 F/ IS
  • Flange / Coil Housing MOC MS / CS / SS 316 / SS 304
  • Operating Pressure Up to DN 80 – PN 40, From DN 100 to DN 200 – PN 16, From DN 250 to DN 350 – PN 10
  • Transmitter Mounting Remote / Integral
  • Types of Transmitters SR1000A / SR1000AP
  • Communication RS 485(default) / RS 232(optional) available in SR1000AP
  • Data Logging 5850 number of readings can be logged in SR1000AP

Manas Electromagnetic flow meters are designed to meet diverse application requirements, offering exceptional performance and accuracy. The flow meters are equipped with various liners to ensure compatibility with different liquids and conditions.

For high-temperature liquid measurement applications up to 150C, PTFE liners are utilized. These liners are also suitable for handling toxic liquids such as strong acids or corrosive substances. When dealing with extremely high temperatures up to 200C and abrasive slurries, PFA liners with appropriate hardness are employed.

In scenarios involving raw water containing sand and quartz particles, Hard Rubber liners are the preferred choice. These liners, when selected with the proper hardness, exhibit minimal wear and tear. Neoprene rubber liners, on the other hand, are commonly used for potable or purified drinking water applications.

The construction of Manas Electromagnetic flow meters follows the full bore type, resulting in negligible pressure drop. By incorporating proper upstream and downstream lengths of pipe during installation, these flow meters can deliver precise flow measurements with uncertainties as low as 0.3%.

Experience the reliability and accuracy of Manas Electromagnetic flow meters for your flow measurement needs.

View Complete Details

CNG Flow Meter

  • Specialities Direct measurement of mass flow.
  • Line Size DN 15 to DN 200
  • Accuracy ±3 % of Actual Flow Rate between 100% to 5% of Calibrated range
  • Display Blind/LCD 16/2.
  • Model No Scirocco 1000-1 & Scirocco 1000-2
  • Scirocco 1000-1 Sensor and transmitter can be mounted directly on service pipe just by drilling holes with clamps provided. (No spool pieces)
  • Scirocco1000-2 Complete with a spool with an end connection of flange /BSP(M) Threading.
  • Service Fluid Dry & Clean compressed Air / Gas. (Mixture of gases not applicable)
  • End Connection Flange/BSP(M) Threading/ Direct clamp mounting.
  • Output 4-20 mA/RS 485, Pulse, Wireless Data Transfer.
  • Ingress Protection IP- 65
  • Operating Fluid Temp 0 – 100℃
  • Operating Fluid Pressure Up to 10 bar
  • Power Supply 24Vdc/150mA (Without Wireless communication) 24Vdc/300mA (With Wireless Communication).
View Complete Details

Food Grade Electromagnetic Flow Meter

  • 0 – 60 DegC ±0.5 % +-(1mm/sec) of Actual Flow Rate between 100 % to 10 % of calibrated ran
  • 16 characters x 2 rows LCD Display for instantaneous Flow rate, Totaliser, Engg. units Up to DN 80 – PN 40 , From DN 100 to DN 200 – PN 16, From DN 250 to DN 350 – PN 10
  • 0.1 m/s to 10 m/s DN 10 to DN 350
  • RS485 Port. With Telemetry system cloud/GSM/GPRS communication. 1″ to 4″
  • 5 micro-siemens per cm 0.5% of reading from 100% to 10% flow rate
  • 0.1 m/s to 10m/s. (Higher velocities can be catered on request) 110V AC/ 230V AC, 50/60 Hz.(Standard)
  • IP 68 for Primary Flow Sensor 40 Bar max
  • 150 deg C max range 4 to 50 deg C
  • SS 304 PTFE Food Grade
  • SS 316L SS 304/SS 316
  • SS 304/SS 316 As per CGWA guidelines
View Complete Details

Full Bore Type Electromagnetic Flow Meter SS1002

  • Accuracy ±0.5 % +-(1mm/sec) of Actual Flow Rate between 100 % to 10 % of calibrated range
  • Line Size DN 10 to DN 350
  • Operating Temperature HR : 0 – 90 ºC / PTFE : 0 – 150 ºC / PFA : 0 – 200 ºC / Neoprene : 0 – 90 ºC
  • Brand manas microsystems
  • Liner Material HR, PTFE, PFA, Neoprene
  • Electrode MOC SS316, Hastalloy C, TAN, TI
  • Flange Standard ANSI / DIN / BS 10 E / BS 10 F / IS
  • Flange / Coil Housing MOC MS / CS / SS 316 / SS 304
  • Operating Pressure Up to DN 80 – PN 40, From DN 100 to DN 200 – PN 16, From DN 250 to DN 350 – PN 10
  • Transmitter Mounting Remote / Integral
  • Types of Transmitters SS1002
  • Display Type 16 characters x 2 rows LCD Display for instantaneous Flow rate, Totaliser, Engg. units
  • Velocity Range 2.5 m/s to 10 m/s
  • Communication RS 485(default) / RS 232(optional)
View Complete Details

Gas Flow Totaliser

  • Brand Name manas microsystems
  • Accuracy ± 0.25% Of Full Scale
  • Features Provision of Password Protection, Configuration of Two alarms setting on instantaneous Flow rate
  • Model GFT-200
  • Mounting Wall/Panel
  • Enclosure AL Diecast/ABS plastic
  • Power Supply 85 – 265 V ac., 50 Hz Single Phase
  • Steam Pressure 1 to 50Kg/cm2(g) max
  • Terminal Separated for both inputs
View Complete Details

Steam Flow Meter

  • Size 1 inch to 14 inch
  • 185mm ±0.25% of Full Scale
  • manas microsystems Wall/Panel
  • Kg/cm2 (g) or Bar (g) 1 to 100 kg/cm2 (a) max
  • 100°C to 600°C max for superheated steam & 100°C to 309.6°C max for saturated steam Al Die-Cast/ABS plastic
  • 85 to 265V AC,50Hz,single phase RS485 std., RS232 (Optional)
  • Online monitoring and compensation of density 310(L)x160(W)x105(D)
View Complete Details

Clamp On Type Ultrasonic Flow Meter

  • Type Clamp-on type
  • Display Digital
  • Accuracy ±2%
  • Brand Name manas microsystems
  • Features Quick and easy to install and operate, Auto adjustable to various pipe materials, Budget-friendly and adaptable.
  • Applicable Line Sizes DN 50 To DN 1500
  • Model Name/Number CTs-Small, CTm-Medium, CTl-Large
  • Flow Media Type Water
  • Power Supply Universal Supply (85 V AC to 265 V AC at 50 Hz.)
  • Ingress Protection IP 68
  • Temperature -30 to 90 degrees c
View Complete Details

Flow Indicating Totalizer

  • Features Compact in Size, Field Programmable Parameters, Linear or Square Root operation.
  • Applications Effluent treatment plants, Sewage treatment plants, Automobile industries
  • Manas microsystems 4-20 mA d.c
  • Isolated 4 20 mA d.c. proportional to flow rate 24 V D.C @30 mA suitable to power one two-wire Transmitter
  • ±0.25% of F.S. for flow rate as well as totalisation. 1) 4-digit, 7 segment, 0.5” LED display for instantaneous flow rate. And 6 digits, 7 segment, 0.3” LED display for totalisation with programmable decimal point & adjustable count rate, Facility to view additional 2 digits of totalised flow a
  • 2) 16×2 Line LCD option available. 0 to 50 C
View Complete Details

Economical Flow Meter

  • Display Digital
  • Packaging Type Carton Box
  • Accuracy ±1 % Of Actual Flow Rate Between 100% To 10 % Flow Rate
  • End Connections Threaded BSP (M)
  • Meter Size DN10 to DN 50
  • MOC of sensor PP
  • Electrode Material SS316/ Hastelloy C
  • Protection Class IP66
  • Cable Entries 2 no. for Integral transmitter. 1 no. for Remote transmitter
  • Media Pressure 10 Bar
  • Empty tube detection Provided
  • Output Pulse Output 4 to 20 mA dc
View Complete Details

Insertion Type Ultrasonic Flow Meter

  • Features Quick and easy to install and operate, Budget-friendly and adaptable, Highly accurate and reliable.
  • manas microsystems Digital
  • DN50 To DN600 2%
  • IP68 4-20 mA
  • Better than 1% -30 to 160 degrees C
View Complete Details

Insertion Type Electromagnetic Flow Meter

  • Line Size DN 200 to DN 1500
  • Brand manas microsystems
  • Mounting Insertion type with Isolation Valve
  • Application Water (Non-toxic)
  • Electrode MOC SS 316
  • Media Pressure 10 Kg/cm2 max
  • Temperature 0-60 ºC
  • Flange Mounting Assembly SS 304
  • Terminal box IP-68
  • Insertion Probe Material SS304
  • Transmitter SR1000AP
  • Velocity Range 0.1 m/s to 2 m/s
  • Transmitter Mounting Remote / Integral
  • Communication RS 485(default) / RS 232(optional)
  • Data Logging 5850 number of readings can be logged
  • Ingress Protection IP-67
  • Power Supply 230Vac, 50Hz, Single Phase, ± 10%   110Vac, 50Hz, Single Phase, ± 10% 24Vdc ± 10%
View Complete Details

Large Electromagnetic Flow Meter

  • Display Digital
  • Primary Flow Sensor Mega Sroat
  • Meter Size DN400 to DN1600 (Sizes above DN 1000 available on request)
  • Pipe Material SS304(nonmagnetic)
  • Liner Material Hard rubber/PTFE
  • Flanges Material CS/SS 316/SS 304/ SS 316
  • Coil Housing Material CS (Polyurethane Painted)/SS304/SS316
  • Body Material CS/SS 316/SS 304
  • Media Pressure PN10
  • Media Temperature 0-80 deg C max
  • Operating Ambient Temperature 0-60 deg C
  • Ingress Protection IP-68
  • High accuracy of measurement 0.5%. of Reading.
  • Transmitter SR1000A / SR1000AP / MS1010
  • Transmitter Mounting Remote / Integral
View Complete Details

Solar Powered Flow Meters

  • Specialities LCD with backlight, 4 tactile-feedback membrane keypads, Solar-powered. No other power supply is needed.
  • Application Waste Water treatment plants, Mining Industry, Effluent treatment plants
  • output Current 4 – 20mA
View Complete Details

Solar Powered Flow Meter

  • Min. Order (MOQ) 1 piece
  • Material Stainless Steel
  • Driven Type Electric
  • Application Water
  • Country of Origin India
  • Display Digital
  • Accuracy +-0.5%
View Complete Details

Wafer Style Electromagnetic Flow Meter

  • Line Size DN 50 to DN 200
  • Display Digital
  • Accuracy Better than 1% of reading
  • Brand manas microsystems
  • Mounting JAL-OAGH 300 and SMART JAL-OAGH 300 – In-Line [Sandwiched between 2 ANSI 150 Class Flanges]
  • Liner Material PTFE / HR
  • Electrode MOC SS316, Hastelloy C
  • Coil Housing SS 304 Without Paint
  • Media Pressure     40 Bar – From DN 50 to DN 80   16 Bar – From DN 100 to DN 200
  • Media Temperature For PTFE Liner – 0 to 150⁰C   For Hard Rubber – 0 to 90⁰C
  • Min Media Conductivity Greater than 5 S/cm
  • Ingress Protection IP-67
  • Transmitter MFT-01 / SJ-1102
  • Communication RS 485(default) / RS 232(optional) available in SJ-1102
  • Transmitter Mounting Remote / Integral
View Complete Details

Steam Flow Totaliser

  • Accuracy ± 0.25% Of Full Scale
  • Brand Name manas microsystems
  • Features Universal Power supply, Mass flow calculation as per ASME Algorithm, Password protection, Seven user-friendly operating modes
  • Applications Engineering & Automation, Chemical/pharmaceutical, Food & Drugs, Petrochemicals
  • Model SFT-200
  • Mounting Wall/Panel
  • Enclosure AL Diecast/ABS plastic
  • Power Supply 85 – 265 V ac., 50 Hz Single Phase
  • Steam Pressure 1 to 100 Kg/cm2(g) max
  • Steam Temperature 100°C to 600°C max for superheated steam, 100°C to 300°C for saturated steam
View Complete Details
Tell Us What are you looking for? Will call you back