Post Buy Requirement

Our Products

  1. Measurement Gauges & Fittings 4 Products available
  2. Calibrators And Monitoring Systems

    2 Products available
  3. Level Controllers

    2 Products available
  4. Level Transmitters

    1 Products available
  5. Magnetic Switch

    1 Products available
  6. Boilers

    1 Products available
  7. High Voltage Circuit Breaker

    1 Products available
  8. Others Products 1 Products available

Our Products

Our product range contains a wide range of Mobray Dual Control

Float Liquid Level Transmitter

  • Brand Name Malhotra Make
  • Place of Origin New Delhi, India

We are leaders in providing the Float Liquid Level Transmitter. Our Float Liquid Level Transmitter is made from quality components and material, which enhances its usage life. The Float Liquid Level Transmitter is precalibrated at the factory, so no field calibration is required.

Outstanding Features

  • 4-20 mA processed output signal, 2 or 4 wire units
  • Continuous 'Float Type' Analog Sensor, In materials, resistive to most liquids
  • High accuracy & repeatability
  • Adjustable multiple Alarm Relays
  • Customized lengths up to 6 meters
  • Liquid Level or Liquid/Liquid Interface Detection

Introduction

Float operated liquid level transmitter, indicator and controller, comprises of a level transducer and a signal converter and is used for continuous level indication and control of any liquid, chemically compatible with the transducer material, unaffected by electrical conductivity, temperature, pressure or viscosity. The Floats are designed for variety of liquids and its unique self-cleaning construction is well suited for even sticky or dirty environments, reliability and accuracy-this is an ideal transmitter. Operating PrincipleThe Unit operates on the principle of buoyancy. During the rise and fall of liquid level, the Float moves and the magnetic field change and actuate the chain which develops a proportional voltage. The sensed voltage is fed to a transmitter for converting it to a signal of 0-5 V Dc or 4 � 20 mA. The transmitter can also be incorporated with a digital display or step less adjustable multiple alarm relays (featuring high level alarm, low level alarm, or both & low level pump (or solenoid valve) on & high level off and vice-versa. ConstructionThe transducer consists of a float and guide tube assembly in nonmagnetic material to achieve undisturbed flux. The float can be in nylon, PP or SS. No gasket or seals are used and there is only one moving part, the float assuring long trouble free life. Being entirely glandless, there is no possibility of fluid leakage into the transducer. Installation and Wiring : The transducer is mounted internally and externally through a chamber by means of a flange connection. External mounting is adopted to overcome limited space within the tank or where mechanical devices operate or where isolation tank is required for regular servicing. The Transducer is recalibrated in the factory and comes to you ready for installations. For operation of level transducer, it has to work in conjunction, with a signal converter which have line or loop powered electronics. Line powered transmitter can be incorporated with a digital display and / or adjustable multiple alarm relays. Loop powered transmitter is employed for remote signaling to a process indicator / controller.

Used In

  • Tanks for
    • Oil
    • Fuel
    • Milk
    • Chemicals
    • Pure/Industrial Water
    • Ship/LPG
  • Pressurized vessels
  • Waste water and sewage treatment plants

Specifications

Measuring range 6 Meters max
Accuracy at range 1000 mm : ± 1% FS
2000 mm : ± 0.5% FS
4000 mm : ± 0.25 %n FS
Installation Top with 80 - 100 NB Flange in SS 304/316/pp/ptf lined
Float 75/100 mm Ø in SS 304/316/pp/ptfe coated
Guide Tube SS / ptfe : 100 oC / PP : 80 oC
SS/ptfe coated 15 kg/cm2g/PP : 1 kg/cm2 g
Enclosure Protection Weather proof to IP 65


Table

Signal Converter 4 wire system 2 Wire System
Electronics Line powered, Nonintegral with Transducer Loop powered, integral with transducer
Input Variable resistance from transducer Variable resistance from transducer
O/P 4-20 mA (Optional 0-20 mA ro 0-5 DC) 4-20 mA
Max. Load 400 Ohms 400 Ohms
Supply 24V DC/220 V AC 24 V DC
Digital Display (Optional) 3 ½ digits (% of Engg. Units)  
Control (Optional) Multiple stepless adjustable, O/P relays rated for 5A, 230V AC  
Version Wall Panel  
Enclosure Protection IP 30/IP 65  

Download


Download Detail File : Click Here
View Complete Details

Air Break Switches

  • Application Industrial Use
  • Feature Easy To Install, Electrical Porcelain, Four Times Stronger, Proper Working, Sturdy Construction
  • Condition New
  • Frequency 0-50Hz, 200-400Hz, 50-100Hz
  • Tensile Strength 0-5Mpa, 10-15Mpa, 5-10Mpa
  • Warranty 5yrs
  • Cooling System Air Cooling, Oil Cooling
  • Current Type Double Phase, Single Phase, Triple Phase

Using premium packaging materials, we secure our products properly for transportation and label it properly to provide information such as address of manufacturer/distributors, MRP, quantity, etc. We have trustworthy shipping facilities available to make on time deliveries to the destination.

View Complete Details

Magnetic Level Switch

  • Application Magnetic Use
  • Voltage 200VDC, 230VAC
  • Frequency 50HZ, 60Hz
  • Power 0-5Amp, 10-15Amp, 5-10Amp
  • Temperature 0Dig C To + 60Dig C
  • Hole Diameter 0-20mm, 20-40mm
  • Setting Range 0-1500pF, 1500-3000pF

Malhotra Bros & Co. is a well-known Magnetic Level Switch Manufacturer and Supplier in Delhi. The Magnetic Level Switch goes through several quality-checks, which ensure its top-notch quality. The Magnetic Level Switch is an economical, maintenance free and reliable device used for high, low or intermediate point level switching. The Magnetic Level Switch is for tanks with inaccessible tops or bottoms and where insertion depths of top mounted models are exceeded. Construction & OperationCompact and rugged construction, consisting of a free moving float assembly and a switch enclosure in non-magnetic material to achieve undisturbed magnetic flux. It employs dual magnets- one carried out by the float arm and the other by the contacts carriers, housed in the switch enclosure. A change in the liquid level brings the like poles of the dual magnets opposite to each other, and resulting repulsion force ensures a change-over of contacts, of the switch housing. These Magnetic Level Switches come in various non-magnetic materials and construction styles to suit board range of medias/applications. It is designed to provide high repeatability and to minimize effects of shock, vibration & pressure.

Installation

  • Mounted internally or external through a chamber. External mounting is resorted to, where space is a limiting factor or mechanical devices like stirrers operate within the tank. Besides, in applications like boilers, reaction kettles etc., with external mounting, isolation are possible for regular servicing
  • The switch is normally side-mounted; however for applications like slurry, vertical-installation is preferred
  • On no account must a switch be used for the direct starting of burners, heaters, Motor-pumps, alarm, It is essential that the contacts are wired in series with the relay coil (N/V coil) in a contactor starter

Applications

  • Manual start & auto off in storage tanks
  • Oil storage tanks to indicate high level, low levels or filling the tanks automatically
  • Condensate receivers to control the operation of an electrically driven condensate pump
  • Main water storage tanks to control the action of the pump used for filling or emptying the tank, automatically
  • In baby boiler auto control of Pump motor & Electric Heater
  • For the control and indication of liquid levels in vessels under vacuum
  • In storage and service tanks on board ship to give indications in the Engine Room when the level in the tank is too high or too low

Where a number of level switches are employed they can be supplied together with a suitable indicator and Alarm Panel embodying signal lights and an audible alarm system.

Specifications

Construction STD. L.S. / ADJ. LS. / EXT. LS./Vertical
Styles L.S. / Vertical See Saw L.S. / Miniature L.S.
Installation Side / Top
Switch Weather proof / Ex-proof
Enclosure with % "NPT
Float 304SS/3 16SS/PP
Min. Sp. Gravity 0.7 (STD) 0.5 (Optional)
Mounting Flanged or screwed
Switch Type Capacity Airbreak single - pole double - throw & with silver Cadmium oxide contacts
A.C. 440V - 1.0 Amp. 250V - 2.5 Amp
D.C. 24V-2.5 Amp. 240 V - 0.5 Amp.
Switch Fixed / Adjustable in steps from
Differential 10 - 300 mm depending upon float size/arm extension/cam positioning
Accuracy/Repeatability ± 2 mm / ± mm
Load / Insulation Resistave / 150 Magaohms at 500 V.D.C
Max.Temperature Upto 210 oC depending upon float / switch element configurations
Max. Pressure Upto 20 kgs/cm2 depending upon float Materials & dimensions
External Cage (Optional) Flanged or screwed mounting in MS / 304 SS / 316 S3 material

Ordering Information

 

  • Type of level switch
  • Working pressure & temperature
  • Specific gravity of Liquid
  • Type of function


Continuous development of our products may necessitate changes in these details without notice.

Precautions

 

 

On no account must a switch be used for the direct starting of burners, heaters, motors-pumps, alarms, it is essential that the contacts are wired in series with the relay coil (N/V coil) in a contactor starter.


Trouble Shooting

 

 

  • Magnetic Level switch, Float and cam not moving up and down
    • Check the S.S. Float
    • If puncture, replace the same with a new one
    • Check the sediments on the cam
    • If present, clean the same
  • Low level alarm not working
    • Check the alarm unit (hooter) and its electrical wiring
    • If shows open, replace the switch with a new one


Maintenance

 

 

  • Periodic maintenance is required in the form of cleaning of float and cam
  • Check magnetic strength of primary magnet
  • Ensuring that the wiring is in good order and that all screws are tight
  • Check that the float is not waterlogged
  • Check insulation of wires connecting switch head







Download


Download Detail File : Click Here
View Complete Details

Float Liquid Level Indicator

  • Material Steel
  • Application Testing Water Level
  • Condition New
  • Display Type Analog
  • Automatic Grade Automatic
  • Measuring Range 100-200mm, 200-300mm, 500-600mm, 600-700mm
  • Gauge Diameter 20-40mm, 60-80mm
  • Guage Size 2inch, 8inch
  • Feature Accuracy, Robust Construction, Rust Proof

We are reckoned as a Float Liquid Level Indicator Manufacturer and Supplier in Delhi. Our Float Liquid Level Indicator is made from quality components and material, which make it durable. The Float Liquid Level Indicator is used for providing a proper and continuous indication of level of different types of liquid. The Float Liquid Level Indicator is designed for working with a diverse range of liquids. The reliable Float Liquid Level Indicator comes at economical price.

Outstanding Features

  • Durable
  • Precalibrated at Factory No field Calibration required
  • 4-20 mA processed output signal, 2 or 4 wire units
  • Continuous 'Float Type' Analog Sensor, In materials, resistive to most liquids
  • High accuracy & repeatability
  • Adjustable multiple Alarm Relays
  • Customized lengths up to 6 meters
  • Liquid Level or Liquid/Liquid Interface Detection
  • Works under sticky and dirty environment

Useful For

  • Oil tanks
  • Fuel tanks
  • Milk tanks
  • Chemicals tanks
  • Pure/Industrial Water tanks
  • Ship/LPG Tanks
  • Pressurized vessels
  • Waste water and sewage treatment plants

Introduction

Float operated liquid level transmitter, indicator and controller, comprises of a level transducer and a signal converter and is used for continuous level indication and control of any liquid, chemically compatible with the transducer material, unaffected by electrical conductivity, temperature, pressure or viscosity. Operating PrincipleThe Unit operates on the principle of buoyancy. During the rise and fall of liquid level, the Float moves and the magnetic field changes & actuates the chain which develops a proportional voltage. The sensed voltage is fed to a transmitter for converting it to a signal of 0-5 V Dc or 4 20 mA. The transmitter can also be incorporated with a digital display or step less adjustable multiple alarm relays (featuring high level alarm, low level alarm, or both & low level pump (or solenoid valve) on & high level off and vice-versa. ConstructionThe transducers consist of a float and guide tube assembly in non-magnetic material to achieve undisturbed flux. The float can be in nylon, PP or SS. No gasket or seals are used and there is only one moving part, the float assuring long trouble free life. Being entirely glandless, there is no possibility of fluid leakage into the transducer. Installation and WiringThe transducer is mounted internally and externally through a chamber by means of a flange connection. External mounting is adopted to overcome limited space within the tank or where mechanical devices operate or where isolation tank is required for regular servicing. The Transducer is precalibrated in the factory and comes to you ready for installation. For operation of level transducer, it has to work in conjunction, with a signal converter which have line or loop powered electronics. Line powered transmitter can be incorporated with a digital display and / or adjustable multiple alarm relays. Loop powered transmitter is employed for remote signaling to a process indicator / controller.

Specifications

Measuring range 6 Meters max
Accuracy at range 1000 mm : ± 1% FS
2000 mm : ± 0.5% FS
4000 mm : ± 0.25 %n FS
Installation Top with 80 - 100 NB Flange in SS 304/316/pp/ptf lined
Float 75/100 mm Ø in SS 304/316/pp/ptfe coated
Guide Tube SS / ptfe : 100 oC / PP : 80 oC
SS/ptfe coated 15 kg/cm2g/PP : 1 kg/cm2 g
Enclosure Protection Weather proof to IP 65




Table

Signal Converter 4 wire system 2 Wire System
Electronics Line powered, Nonintegral with Transducer Loop powered, integral with transducer
Input Variable resistance from transducer Variable resistance from transducer
O/P 4-20 mA (Optional 0-20 mA ro 0-5 DC) 4-20 mA
Max. Load 400 Ohms 400 Ohms
Supply 24V DC/220 V AC 24 V DC
Digital Display (Optional) 3 ½ digits (% of Engg. Units)  
Control (Optional) Multiple stepless adjustable, O/P relays rated for 5A, 230V AC  
Version Wall Panel  
Enclosure Protection IP 30/IP 65  

 

Download


Download Detail File : Click Here
View Complete Details

Magnetic Liquid Level Indicator

4,000 - 20,000 /Piece Get Latest Price
  • Type Magnetic Liquid Level Indicator
  • Material Steel
  • Application Testing Water Level
  • Color Multicolor
  • Feature Accuracy, Easy To Fit, Measure Fast Reading, Perfect Strength, Robust Construction
  • Condition New
  • Display Type Analog
  • Automatic Grade Automatic
  • Measuring Range 100-200mm, 200-300mm, 400-500mm, 500-600mm, 700-800mm, 800-900mm
  • Gauge Diameter 20-40mm, 40-60mm

We are known as a trusted Magnetic Liquid Level Indicator Manufacturer and Supplier in Delhi, offering a well-tested range. The Magnetic Liquid Level Indicator is made from quality components, which make it more durable and reliable. The Magnetic Liquid Level Indicator is known for its smooth and accurate operation. Our Magnetic Liquid Level Indicator comes at competitive prices. IntroductionLevel Indicators are laterally to be flanged to the tank as a communicating pressure resistant vessel and serve for level measurement and supervision of liquids and liquefied gases in open and closed tanks. These can be used when instruments with high resistance to pressure and temperature are required or if sight glasses or similar indication parts for reasons of security cannot be used. This measuring system is preferred because there is a safe pressure and gastight separation between measuring and indication part. Therefore, the instruments are suitable for a wide range of applications for the chemicals and Pharmaceutical industries for the petrochemical industry, refineries, oil and fuel tanks, storage tanks, etc. In a communicating float cage which can be flanged to a tank is a cylindrical Float of stainless steel or plastic. A permanent magnet forms part of the float. Outside the liquid on the dry side a Magnetic Level Indication is fitted to the float cage.

Model Number Description

  • Model ML- R (Level Indicators with Magnetic rollers) consists of red/white magnetic rollers equipped with small rod magnets are rotated one after another at an angle of 180" by the directed field of the permanent magnet of the float inside the float cage. Magnetic rollers rotate from white to red on rising level and from red to white on falling level or vice versa
  • Model ML- D (Level Indicators with Drag Magnet) Magnetic Level Indicators consists of drag Magnet instead of Magnetic rollers. Drag magnet moves inside the glass tube which is fixed to the side of the float cage. High & low alarm can be provided at two extreme positions. The level in a tank or agitating machine is permanently indicated as a red column even in the case of power Failure. Level Indicators are outside the liquid in Exzone I and can be used in hazardous atmosphere. It is possible to measure the level of aggressive, combustible, viscous, dangerous, toxic, hot, compressed, agitated and contaminated liquids with high precision and operability

Applications

  • Applicable for level measurement in open or closed tanks
  • Applicable for level measurements and supervision of liquids and liquefied gases
  • Applicable in all ranges of industry owning to corrosion resistant materials
  • Applicable under extreme operating conditions
  • Simple, sturdy, secure against fracture and non-serviced structure
  • Pressure and gastight separation between measuring and indication part

Therefore, the instruments are suitable for a wide range of applications for the chemicals and Pharmaceutical industry, refineries, oil and fuel tanks, storage tanks, etc.

Specifications

Process connection 1" Std Flange
Float cage 304/316 SS / PP / Nylong
Centre to centre Distance 0.5 M.1.5 M and 2M Distance upto 6M can be supplied for special requirements
Operaying Pressure 10 kg/cm2 for style 1 & 15 kg/cm2 for style 2
Operating Temp. Indication 150 oC
Magnetic rollers : Model ML - R
Drag Magnet : Model ML - D
Measuring Accuracy ± 5 mm
Auto control (optional) Pump starts at Low level, trips at high level & Vice-versa
Alarms (optional) High and low level Alarms can be provided. Transisterised relay (optional) having SPDT contact of 5 Amp. 230 C. ac

 



Download


Download Detail File : Click Here
View Complete Details

Tube Type Liquid Level Controller

  • Application Control Liquid Level
  • Condition New
  • Power 1-3kw, 3-6kw, 9-12kw
  • Driven Type Electric
  • Warranty 5years

We are among the leading Manufacturers and Suppliers of Tube Type Liquid Level Controller. The Tube Type Liquid Level Controller is made from quality components, ensuring the delivery of excellent performance for years and years. The Tube Type Liquid Level Controller comes at market leading price. IntroductionMagnetic float and tube type, level switch in conjunction with control unit is an established and reliable technique in industry for point liquid level sensing and control in open or pressurized vessels. It offers trouble free service in conductive/non-conductive liquids under widely varying temperatures, pressure, liquid viscosities and corrosive conditions. Besides, it provides high repeatability and effect of shocks/vibrations is minimal. Construction & OperationSimple and sturdy construction, consisting of a float and guide tube, made of nonmagnetic material to achieve an undisturbed magnetic flux. The float has a magnetic system within it and moves freely along the guide tube, which contains glass encapsulated hermetically sealed switches, located at preset positions. Reliability of float movement is achieved through suitable clearance between it and the tube. Float follows the liquid level and magnetically actuates the contacts to give an electrical signal, which in turn can operate remote alarm or a relay to control auxiliary devices like solenoid/motorized valve or pump motor starters. Single/multiple switching is possible through a single float, however to suit specific applications, multiple floats can be employed. The Tube Type Liquid Level Controller is available in various materials and construction styles to suit wide variety of medias/applications. InstallationsMounted internally or externally through a chamber. External mounting adopted to overcome limited space within the tank or where mechanical devices like stirrers operate or where isolation tank is required for regular servicing. It can be installed vertically from top to bottom. Side installation is also possible with slight modification. Control UnitContains electronics and comes separate as an accessory to the sensor. To allow low power switches to control high amperage or voltage devices. Or To convert non-latching switch outputs into latching alarm outputs. The relay provided in the Controller is of 5 Amp. Capacity. On no account must a switch be used for the direct starting of burners, heaters, motor pumps, alarm, it is essential that the contacts are wired in series with the relay coil (N/V coil) in a contactor starter.

Applications

  • Auto Pump Motor Start/Stop for overhead/underground Tanks
  • Indication of high, low and intermediate levels audible alarm and operation of pumps and solenoid valves
  • Level Switches are widely used in storage tanks and reservoirs of all types chemical processing tanks and systems, automatic safety interlocks, pump motor control, etc.

Therefore the instruments are suitable for a wide range of applications for the chemicals and pharmaceutical industries for the petrochemical Industry refineries, oil and fuel tanks, storage tanks etc. Features

  • Safe instrument for domestic / industrial purpose
  • Prevents motor burn-out
  • Prevents overflow
  • Maintains a minimum level
  • Works round the clock
  • Requires no maintenance & attendant
  • Cuts down electricity bills
  • Auto/Manual switch provided to operate in case of malfunctioning

Specifications

Installation Top, Bottom or Side
Terminal Housing Weathproof/Ex-proof in Aluminium with ¾" NPT cable alternatively plug-in type connector or epoxy potting with extended wires
Guide Tube Normally 304 SS / 316 SS / PP upto 3 mtr length only on request
Float 304 SS / 316 SS / PP / PVC / Nylon in various dimensions
Min. Sp. Gr. 0.7 / 0.8 depending upon the float material and dimensions
Mounting Flanged or screwed
Preset Levels 1 to maximum of 6 (factory set) depending upto guide tube / float dimensions
Differential 12 mm - 3000 mm
Accuracy/Repeatability ± 2 mm / ± 1 mm
Load/Insulation Resistive or Inductive / PVC or PTFE insulating material to stand 150 mega-ohms at 500 VDC
Max. Temperature Upto 120 C depending upon guide tube/float configuration
Max. Pressure Upto 10 Kgs/cm depending upon guide tube/float material & thickness
Control Unit Remote (Wall or Panel Mounted) or Integral
External Cage (Optional) Flanged or screwed mounting, in MS / 304 SS / 316 SS material

 

Download


Download Detail File : Click Here
View Complete Details

Float Liquid Level Controller

  • Application Control Liquid Level
  • Voltage 110V, 220V, 440V
  • Condition New
  • Display Type Remote
  • Automatic Grade Manual
  • Warranty 5years

We are a Manufacturer and Supplier of Float Liquid Level Controller. The Float Liquid Level Controller is made from quality components and material. The Float Liquid Level Controller provided by us is durable and delivers consistent performance. The Float Liquid Level Controller comes at leading market price.

Outstanding Features

  • Precalibrated at Factory No field Calibration required
  • 4-20 mA processed output signal, 2 or 4 wire units
  • Continuous 'Float Type' Analog Sensor, In materials, resistive to most liquids
  • High accuracy & repeatability
  • Adjustable multiple Alarm Relays
  • Customized lengths up to 6 meters
  • Liquid Level or Liquid/Liquid Interface Detection

Introduction

Float operated liquid level transmitter, indicator and controller, comprises of a level transducer and a signal converter and is used for continuous level indication and control of any liquid, chemically compatible with the transducer material, unaffected by electrical conductivity, temperature, pressure or viscosity. The Floats are designed for variety of liquids and its unique self-cleaning construction is well suited for even sticky or dirty environments, reliability and accuracy-this is an ideal transmitter. Operating PrincipleThe Unit operates on the principle of buoyancy. During the rise and fall of liquid level, the Float moves and the magnetic field changes & actuates the chain which develops a proportional voltage. The sensed voltage is fed to a transmitter for converting it to a signal of 0-5 V Dc or 4 20 mA. The transmitter can also be incorporated with a digital display or step less adjustable multiple alarm relays (featuring high level alarm, low level alarm, or both & low level pump (or solenoid valve) on & high level off and vice-versa. ConstructionThe transducer consists of a float and guide tube assembly in non-magnetic material to achieve undisturbed flux. The float can be in nylon, PP or SS. No gasket or seals are used and there is only one moving part, the float assuring long trouble free life. Being entirely glandless, there is no possibility of fluid leakage into the transducer. Installation and WiringThe transducer is mounted internally and externally through a chamber by means of a flange connection. External mounting is adopted to overcome limited space within the tank or where mechanical devices operate or where isolation tank is required for regular servicing. The Transducer is precalibrated in the factory and comes to you ready for installation. For operation of level transducer, it has to work in conjunction, with a signal converter which have line or loop powered electronics. Line powered transmitter can be incorporated with a digital display and / or adjustable multiple alarm relays. Loop powered transmitter is employed for remote signaling to a process indicator / controller.

Ideal For

  • Tanks for Oil, Fuel, Milk, Chemicals
  • Pure/Industrial Water
  • Ship/LPG Tanks
  • Pressurized vessels
  • Waste water and sewage treatment plants

Specifications

Measuring range 6 Meters max
Accuracy at range 1000 mm : ± 1% FS
2000 mm : ± 0.5% FS
4000 mm : ± 0.25 %n FS
Installation Top with 80 - 100 NB Flange in SS 304/316/pp/ptf lined
Float 75/100 mm Ø in SS 304/316/pp/ptfe coated
Guide Tube SS / ptfe : 100 oC / PP : 80 oC
SS/ptfe coated 15 kg/cm2g/PP : 1 kg/cm2 g
Enclosure Protection Weather proof to IP 65


Table

Signal Converter 4 wire system 2 Wire System
Electronics Line powered, Nonintegral with Transducer Loop powered, integral with transducer
Input Variable resistance from transducer Variable resistance from transducer
O/P 4-20 mA (Optional 0-20 mA ro 0-5 DC) 4-20 mA
Max. Load 400 Ohms 400 Ohms
Supply 24V DC/220 V AC 24 V DC
Digital Display (Optional) 3 ½ digits (% of Engg. Units)  
Control (Optional) Multiple stepless adjustable, O/P relays rated for 5A, 230V AC  
Version Wall Panel  
Enclosure Protection IP 30/IP 65

Download


Download Detail File : Click Here
View Complete Details

Boiler Dual Control

  • Brand Name Malhotra Make
  • Place of Origin New Delhi, India
boiler dual control for automatic control of waler in boilers and protect the boiler with low level trip.
View Complete Details

Mobray Dual Control

  • Application Industrial
  • Phase Three Phase
  • Power 220V
  • Size 96 x 96 x 110 mm.
  • Accuracy +/- 0.1oC for Temp. and + / - 0.1% for RH.
  • Temperature range -200~1300

We understand that the use of finest grade raw material brings forth high quality product line. In addition to this, we make sure that the material is sourced from the reliable places only. Be it online or cash deposit, the financial operations are carried out only under the stern management, supervision of professionals. To make our payment procedures highly secured, we make use of the leading technologies to avoid any fraud.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by MALHOTRA BROS & CO PRIVATE LIMITED from Delhi, Delhi.
Post Buy Requirement

Our Products

  1. Measurement Gauges & Fittings 4 Products available
  2. Calibrators And Monitoring Systems

    2 Products available
  3. Level Controllers

    2 Products available
  4. Boilers

    1 Products available
  5. High Voltage Circuit Breaker

    1 Products available
  6. Level Transmitters

    1 Products available
  7. Magnetic Switch

    1 Products available
  8. Others Products 1 Products available

Our Products

Our product range contains a wide range of Mobray Dual Control

Float Liquid Level Transmitter

  • Brand Name Malhotra Make
  • Place of Origin New Delhi, India

We are leaders in providing the Float Liquid Level Transmitter. Our Float Liquid Level Transmitter is made from quality components and material, which enhances its usage life. The Float Liquid Level Transmitter is precalibrated at the factory, so no field calibration is required.

Outstanding Features

  • 4-20 mA processed output signal, 2 or 4 wire units
  • Continuous 'Float Type' Analog Sensor, In materials, resistive to most liquids
  • High accuracy & repeatability
  • Adjustable multiple Alarm Relays
  • Customized lengths up to 6 meters
  • Liquid Level or Liquid/Liquid Interface Detection

Introduction

Float operated liquid level transmitter, indicator and controller, comprises of a level transducer and a signal converter and is used for continuous level indication and control of any liquid, chemically compatible with the transducer material, unaffected by electrical conductivity, temperature, pressure or viscosity. The Floats are designed for variety of liquids and its unique self-cleaning construction is well suited for even sticky or dirty environments, reliability and accuracy-this is an ideal transmitter. Operating PrincipleThe Unit operates on the principle of buoyancy. During the rise and fall of liquid level, the Float moves and the magnetic field change and actuate the chain which develops a proportional voltage. The sensed voltage is fed to a transmitter for converting it to a signal of 0-5 V Dc or 4 � 20 mA. The transmitter can also be incorporated with a digital display or step less adjustable multiple alarm relays (featuring high level alarm, low level alarm, or both & low level pump (or solenoid valve) on & high level off and vice-versa. ConstructionThe transducer consists of a float and guide tube assembly in nonmagnetic material to achieve undisturbed flux. The float can be in nylon, PP or SS. No gasket or seals are used and there is only one moving part, the float assuring long trouble free life. Being entirely glandless, there is no possibility of fluid leakage into the transducer. Installation and Wiring : The transducer is mounted internally and externally through a chamber by means of a flange connection. External mounting is adopted to overcome limited space within the tank or where mechanical devices operate or where isolation tank is required for regular servicing. The Transducer is recalibrated in the factory and comes to you ready for installations. For operation of level transducer, it has to work in conjunction, with a signal converter which have line or loop powered electronics. Line powered transmitter can be incorporated with a digital display and / or adjustable multiple alarm relays. Loop powered transmitter is employed for remote signaling to a process indicator / controller.

Used In

  • Tanks for
    • Oil
    • Fuel
    • Milk
    • Chemicals
    • Pure/Industrial Water
    • Ship/LPG
  • Pressurized vessels
  • Waste water and sewage treatment plants

Specifications

Measuring range 6 Meters max
Accuracy at range 1000 mm : ± 1% FS
2000 mm : ± 0.5% FS
4000 mm : ± 0.25 %n FS
Installation Top with 80 - 100 NB Flange in SS 304/316/pp/ptf lined
Float 75/100 mm Ø in SS 304/316/pp/ptfe coated
Guide Tube SS / ptfe : 100 oC / PP : 80 oC
SS/ptfe coated 15 kg/cm2g/PP : 1 kg/cm2 g
Enclosure Protection Weather proof to IP 65


Table

Signal Converter 4 wire system 2 Wire System
Electronics Line powered, Nonintegral with Transducer Loop powered, integral with transducer
Input Variable resistance from transducer Variable resistance from transducer
O/P 4-20 mA (Optional 0-20 mA ro 0-5 DC) 4-20 mA
Max. Load 400 Ohms 400 Ohms
Supply 24V DC/220 V AC 24 V DC
Digital Display (Optional) 3 ½ digits (% of Engg. Units)  
Control (Optional) Multiple stepless adjustable, O/P relays rated for 5A, 230V AC  
Version Wall Panel  
Enclosure Protection IP 30/IP 65  

Download


Download Detail File : Click Here
View Complete Details

Air Break Switches

  • Application Industrial Use
  • Feature Easy To Install, Electrical Porcelain, Four Times Stronger, Proper Working, Sturdy Construction
  • Condition New
  • Frequency 0-50Hz, 200-400Hz, 50-100Hz
  • Tensile Strength 0-5Mpa, 10-15Mpa, 5-10Mpa
  • Warranty 5yrs
  • Cooling System Air Cooling, Oil Cooling
  • Current Type Double Phase, Single Phase, Triple Phase

Using premium packaging materials, we secure our products properly for transportation and label it properly to provide information such as address of manufacturer/distributors, MRP, quantity, etc. We have trustworthy shipping facilities available to make on time deliveries to the destination.

View Complete Details

Magnetic Level Switch

  • Application Magnetic Use
  • Voltage 200VDC, 230VAC
  • Frequency 50HZ, 60Hz
  • Power 0-5Amp, 10-15Amp, 5-10Amp
  • Temperature 0Dig C To + 60Dig C
  • Hole Diameter 0-20mm, 20-40mm
  • Setting Range 0-1500pF, 1500-3000pF

Malhotra Bros & Co. is a well-known Magnetic Level Switch Manufacturer and Supplier in Delhi. The Magnetic Level Switch goes through several quality-checks, which ensure its top-notch quality. The Magnetic Level Switch is an economical, maintenance free and reliable device used for high, low or intermediate point level switching. The Magnetic Level Switch is for tanks with inaccessible tops or bottoms and where insertion depths of top mounted models are exceeded. Construction & OperationCompact and rugged construction, consisting of a free moving float assembly and a switch enclosure in non-magnetic material to achieve undisturbed magnetic flux. It employs dual magnets- one carried out by the float arm and the other by the contacts carriers, housed in the switch enclosure. A change in the liquid level brings the like poles of the dual magnets opposite to each other, and resulting repulsion force ensures a change-over of contacts, of the switch housing. These Magnetic Level Switches come in various non-magnetic materials and construction styles to suit board range of medias/applications. It is designed to provide high repeatability and to minimize effects of shock, vibration & pressure.

Installation

  • Mounted internally or external through a chamber. External mounting is resorted to, where space is a limiting factor or mechanical devices like stirrers operate within the tank. Besides, in applications like boilers, reaction kettles etc., with external mounting, isolation are possible for regular servicing
  • The switch is normally side-mounted; however for applications like slurry, vertical-installation is preferred
  • On no account must a switch be used for the direct starting of burners, heaters, Motor-pumps, alarm, It is essential that the contacts are wired in series with the relay coil (N/V coil) in a contactor starter

Applications

  • Manual start & auto off in storage tanks
  • Oil storage tanks to indicate high level, low levels or filling the tanks automatically
  • Condensate receivers to control the operation of an electrically driven condensate pump
  • Main water storage tanks to control the action of the pump used for filling or emptying the tank, automatically
  • In baby boiler auto control of Pump motor & Electric Heater
  • For the control and indication of liquid levels in vessels under vacuum
  • In storage and service tanks on board ship to give indications in the Engine Room when the level in the tank is too high or too low

Where a number of level switches are employed they can be supplied together with a suitable indicator and Alarm Panel embodying signal lights and an audible alarm system.

Specifications

Construction STD. L.S. / ADJ. LS. / EXT. LS./Vertical
Styles L.S. / Vertical See Saw L.S. / Miniature L.S.
Installation Side / Top
Switch Weather proof / Ex-proof
Enclosure with % "NPT
Float 304SS/3 16SS/PP
Min. Sp. Gravity 0.7 (STD) 0.5 (Optional)
Mounting Flanged or screwed
Switch Type Capacity Airbreak single - pole double - throw & with silver Cadmium oxide contacts
A.C. 440V - 1.0 Amp. 250V - 2.5 Amp
D.C. 24V-2.5 Amp. 240 V - 0.5 Amp.
Switch Fixed / Adjustable in steps from
Differential 10 - 300 mm depending upon float size/arm extension/cam positioning
Accuracy/Repeatability ± 2 mm / ± mm
Load / Insulation Resistave / 150 Magaohms at 500 V.D.C
Max.Temperature Upto 210 oC depending upon float / switch element configurations
Max. Pressure Upto 20 kgs/cm2 depending upon float Materials & dimensions
External Cage (Optional) Flanged or screwed mounting in MS / 304 SS / 316 S3 material

Ordering Information

 

  • Type of level switch
  • Working pressure & temperature
  • Specific gravity of Liquid
  • Type of function


Continuous development of our products may necessitate changes in these details without notice.

Precautions

 

 

On no account must a switch be used for the direct starting of burners, heaters, motors-pumps, alarms, it is essential that the contacts are wired in series with the relay coil (N/V coil) in a contactor starter.


Trouble Shooting

 

 

  • Magnetic Level switch, Float and cam not moving up and down
    • Check the S.S. Float
    • If puncture, replace the same with a new one
    • Check the sediments on the cam
    • If present, clean the same
  • Low level alarm not working
    • Check the alarm unit (hooter) and its electrical wiring
    • If shows open, replace the switch with a new one


Maintenance

 

 

  • Periodic maintenance is required in the form of cleaning of float and cam
  • Check magnetic strength of primary magnet
  • Ensuring that the wiring is in good order and that all screws are tight
  • Check that the float is not waterlogged
  • Check insulation of wires connecting switch head







Download


Download Detail File : Click Here
View Complete Details

Float Liquid Level Indicator

  • Material Steel
  • Application Testing Water Level
  • Condition New
  • Display Type Analog
  • Automatic Grade Automatic
  • Measuring Range 100-200mm, 200-300mm, 500-600mm, 600-700mm
  • Gauge Diameter 20-40mm, 60-80mm
  • Guage Size 2inch, 8inch
  • Feature Accuracy, Robust Construction, Rust Proof

We are reckoned as a Float Liquid Level Indicator Manufacturer and Supplier in Delhi. Our Float Liquid Level Indicator is made from quality components and material, which make it durable. The Float Liquid Level Indicator is used for providing a proper and continuous indication of level of different types of liquid. The Float Liquid Level Indicator is designed for working with a diverse range of liquids. The reliable Float Liquid Level Indicator comes at economical price.

Outstanding Features

  • Durable
  • Precalibrated at Factory No field Calibration required
  • 4-20 mA processed output signal, 2 or 4 wire units
  • Continuous 'Float Type' Analog Sensor, In materials, resistive to most liquids
  • High accuracy & repeatability
  • Adjustable multiple Alarm Relays
  • Customized lengths up to 6 meters
  • Liquid Level or Liquid/Liquid Interface Detection
  • Works under sticky and dirty environment

Useful For

  • Oil tanks
  • Fuel tanks
  • Milk tanks
  • Chemicals tanks
  • Pure/Industrial Water tanks
  • Ship/LPG Tanks
  • Pressurized vessels
  • Waste water and sewage treatment plants

Introduction

Float operated liquid level transmitter, indicator and controller, comprises of a level transducer and a signal converter and is used for continuous level indication and control of any liquid, chemically compatible with the transducer material, unaffected by electrical conductivity, temperature, pressure or viscosity. Operating PrincipleThe Unit operates on the principle of buoyancy. During the rise and fall of liquid level, the Float moves and the magnetic field changes & actuates the chain which develops a proportional voltage. The sensed voltage is fed to a transmitter for converting it to a signal of 0-5 V Dc or 4 20 mA. The transmitter can also be incorporated with a digital display or step less adjustable multiple alarm relays (featuring high level alarm, low level alarm, or both & low level pump (or solenoid valve) on & high level off and vice-versa. ConstructionThe transducers consist of a float and guide tube assembly in non-magnetic material to achieve undisturbed flux. The float can be in nylon, PP or SS. No gasket or seals are used and there is only one moving part, the float assuring long trouble free life. Being entirely glandless, there is no possibility of fluid leakage into the transducer. Installation and WiringThe transducer is mounted internally and externally through a chamber by means of a flange connection. External mounting is adopted to overcome limited space within the tank or where mechanical devices operate or where isolation tank is required for regular servicing. The Transducer is precalibrated in the factory and comes to you ready for installation. For operation of level transducer, it has to work in conjunction, with a signal converter which have line or loop powered electronics. Line powered transmitter can be incorporated with a digital display and / or adjustable multiple alarm relays. Loop powered transmitter is employed for remote signaling to a process indicator / controller.

Specifications

Measuring range 6 Meters max
Accuracy at range 1000 mm : ± 1% FS
2000 mm : ± 0.5% FS
4000 mm : ± 0.25 %n FS
Installation Top with 80 - 100 NB Flange in SS 304/316/pp/ptf lined
Float 75/100 mm Ø in SS 304/316/pp/ptfe coated
Guide Tube SS / ptfe : 100 oC / PP : 80 oC
SS/ptfe coated 15 kg/cm2g/PP : 1 kg/cm2 g
Enclosure Protection Weather proof to IP 65




Table

Signal Converter 4 wire system 2 Wire System
Electronics Line powered, Nonintegral with Transducer Loop powered, integral with transducer
Input Variable resistance from transducer Variable resistance from transducer
O/P 4-20 mA (Optional 0-20 mA ro 0-5 DC) 4-20 mA
Max. Load 400 Ohms 400 Ohms
Supply 24V DC/220 V AC 24 V DC
Digital Display (Optional) 3 ½ digits (% of Engg. Units)  
Control (Optional) Multiple stepless adjustable, O/P relays rated for 5A, 230V AC  
Version Wall Panel  
Enclosure Protection IP 30/IP 65  

 

Download


Download Detail File : Click Here
View Complete Details

Magnetic Liquid Level Indicator

4,000 - 20,000 /Piece Get Latest Price
  • Type Magnetic Liquid Level Indicator
  • Material Steel
  • Application Testing Water Level
  • Color Multicolor
  • Feature Accuracy, Easy To Fit, Measure Fast Reading, Perfect Strength, Robust Construction
  • Condition New
  • Display Type Analog
  • Automatic Grade Automatic
  • Measuring Range 100-200mm, 200-300mm, 400-500mm, 500-600mm, 700-800mm, 800-900mm
  • Gauge Diameter 20-40mm, 40-60mm

We are known as a trusted Magnetic Liquid Level Indicator Manufacturer and Supplier in Delhi, offering a well-tested range. The Magnetic Liquid Level Indicator is made from quality components, which make it more durable and reliable. The Magnetic Liquid Level Indicator is known for its smooth and accurate operation. Our Magnetic Liquid Level Indicator comes at competitive prices. IntroductionLevel Indicators are laterally to be flanged to the tank as a communicating pressure resistant vessel and serve for level measurement and supervision of liquids and liquefied gases in open and closed tanks. These can be used when instruments with high resistance to pressure and temperature are required or if sight glasses or similar indication parts for reasons of security cannot be used. This measuring system is preferred because there is a safe pressure and gastight separation between measuring and indication part. Therefore, the instruments are suitable for a wide range of applications for the chemicals and Pharmaceutical industries for the petrochemical industry, refineries, oil and fuel tanks, storage tanks, etc. In a communicating float cage which can be flanged to a tank is a cylindrical Float of stainless steel or plastic. A permanent magnet forms part of the float. Outside the liquid on the dry side a Magnetic Level Indication is fitted to the float cage.

Model Number Description

  • Model ML- R (Level Indicators with Magnetic rollers) consists of red/white magnetic rollers equipped with small rod magnets are rotated one after another at an angle of 180" by the directed field of the permanent magnet of the float inside the float cage. Magnetic rollers rotate from white to red on rising level and from red to white on falling level or vice versa
  • Model ML- D (Level Indicators with Drag Magnet) Magnetic Level Indicators consists of drag Magnet instead of Magnetic rollers. Drag magnet moves inside the glass tube which is fixed to the side of the float cage. High & low alarm can be provided at two extreme positions. The level in a tank or agitating machine is permanently indicated as a red column even in the case of power Failure. Level Indicators are outside the liquid in Exzone I and can be used in hazardous atmosphere. It is possible to measure the level of aggressive, combustible, viscous, dangerous, toxic, hot, compressed, agitated and contaminated liquids with high precision and operability

Applications

  • Applicable for level measurement in open or closed tanks
  • Applicable for level measurements and supervision of liquids and liquefied gases
  • Applicable in all ranges of industry owning to corrosion resistant materials
  • Applicable under extreme operating conditions
  • Simple, sturdy, secure against fracture and non-serviced structure
  • Pressure and gastight separation between measuring and indication part

Therefore, the instruments are suitable for a wide range of applications for the chemicals and Pharmaceutical industry, refineries, oil and fuel tanks, storage tanks, etc.

Specifications

Process connection 1" Std Flange
Float cage 304/316 SS / PP / Nylong
Centre to centre Distance 0.5 M.1.5 M and 2M Distance upto 6M can be supplied for special requirements
Operaying Pressure 10 kg/cm2 for style 1 & 15 kg/cm2 for style 2
Operating Temp. Indication 150 oC
Magnetic rollers : Model ML - R
Drag Magnet : Model ML - D
Measuring Accuracy ± 5 mm
Auto control (optional) Pump starts at Low level, trips at high level & Vice-versa
Alarms (optional) High and low level Alarms can be provided. Transisterised relay (optional) having SPDT contact of 5 Amp. 230 C. ac

 



Download


Download Detail File : Click Here
View Complete Details

Tube Type Liquid Level Controller

  • Application Control Liquid Level
  • Condition New
  • Power 1-3kw, 3-6kw, 9-12kw
  • Driven Type Electric
  • Warranty 5years

We are among the leading Manufacturers and Suppliers of Tube Type Liquid Level Controller. The Tube Type Liquid Level Controller is made from quality components, ensuring the delivery of excellent performance for years and years. The Tube Type Liquid Level Controller comes at market leading price. IntroductionMagnetic float and tube type, level switch in conjunction with control unit is an established and reliable technique in industry for point liquid level sensing and control in open or pressurized vessels. It offers trouble free service in conductive/non-conductive liquids under widely varying temperatures, pressure, liquid viscosities and corrosive conditions. Besides, it provides high repeatability and effect of shocks/vibrations is minimal. Construction & OperationSimple and sturdy construction, consisting of a float and guide tube, made of nonmagnetic material to achieve an undisturbed magnetic flux. The float has a magnetic system within it and moves freely along the guide tube, which contains glass encapsulated hermetically sealed switches, located at preset positions. Reliability of float movement is achieved through suitable clearance between it and the tube. Float follows the liquid level and magnetically actuates the contacts to give an electrical signal, which in turn can operate remote alarm or a relay to control auxiliary devices like solenoid/motorized valve or pump motor starters. Single/multiple switching is possible through a single float, however to suit specific applications, multiple floats can be employed. The Tube Type Liquid Level Controller is available in various materials and construction styles to suit wide variety of medias/applications. InstallationsMounted internally or externally through a chamber. External mounting adopted to overcome limited space within the tank or where mechanical devices like stirrers operate or where isolation tank is required for regular servicing. It can be installed vertically from top to bottom. Side installation is also possible with slight modification. Control UnitContains electronics and comes separate as an accessory to the sensor. To allow low power switches to control high amperage or voltage devices. Or To convert non-latching switch outputs into latching alarm outputs. The relay provided in the Controller is of 5 Amp. Capacity. On no account must a switch be used for the direct starting of burners, heaters, motor pumps, alarm, it is essential that the contacts are wired in series with the relay coil (N/V coil) in a contactor starter.

Applications

  • Auto Pump Motor Start/Stop for overhead/underground Tanks
  • Indication of high, low and intermediate levels audible alarm and operation of pumps and solenoid valves
  • Level Switches are widely used in storage tanks and reservoirs of all types chemical processing tanks and systems, automatic safety interlocks, pump motor control, etc.

Therefore the instruments are suitable for a wide range of applications for the chemicals and pharmaceutical industries for the petrochemical Industry refineries, oil and fuel tanks, storage tanks etc. Features

  • Safe instrument for domestic / industrial purpose
  • Prevents motor burn-out
  • Prevents overflow
  • Maintains a minimum level
  • Works round the clock
  • Requires no maintenance & attendant
  • Cuts down electricity bills
  • Auto/Manual switch provided to operate in case of malfunctioning

Specifications

Installation Top, Bottom or Side
Terminal Housing Weathproof/Ex-proof in Aluminium with ¾" NPT cable alternatively plug-in type connector or epoxy potting with extended wires
Guide Tube Normally 304 SS / 316 SS / PP upto 3 mtr length only on request
Float 304 SS / 316 SS / PP / PVC / Nylon in various dimensions
Min. Sp. Gr. 0.7 / 0.8 depending upon the float material and dimensions
Mounting Flanged or screwed
Preset Levels 1 to maximum of 6 (factory set) depending upto guide tube / float dimensions
Differential 12 mm - 3000 mm
Accuracy/Repeatability ± 2 mm / ± 1 mm
Load/Insulation Resistive or Inductive / PVC or PTFE insulating material to stand 150 mega-ohms at 500 VDC
Max. Temperature Upto 120 C depending upon guide tube/float configuration
Max. Pressure Upto 10 Kgs/cm depending upon guide tube/float material & thickness
Control Unit Remote (Wall or Panel Mounted) or Integral
External Cage (Optional) Flanged or screwed mounting, in MS / 304 SS / 316 SS material

 

Download


Download Detail File : Click Here
View Complete Details

Float Liquid Level Controller

  • Application Control Liquid Level
  • Voltage 110V, 220V, 440V
  • Condition New
  • Display Type Remote
  • Automatic Grade Manual
  • Warranty 5years

We are a Manufacturer and Supplier of Float Liquid Level Controller. The Float Liquid Level Controller is made from quality components and material. The Float Liquid Level Controller provided by us is durable and delivers consistent performance. The Float Liquid Level Controller comes at leading market price.

Outstanding Features

  • Precalibrated at Factory No field Calibration required
  • 4-20 mA processed output signal, 2 or 4 wire units
  • Continuous 'Float Type' Analog Sensor, In materials, resistive to most liquids
  • High accuracy & repeatability
  • Adjustable multiple Alarm Relays
  • Customized lengths up to 6 meters
  • Liquid Level or Liquid/Liquid Interface Detection

Introduction

Float operated liquid level transmitter, indicator and controller, comprises of a level transducer and a signal converter and is used for continuous level indication and control of any liquid, chemically compatible with the transducer material, unaffected by electrical conductivity, temperature, pressure or viscosity. The Floats are designed for variety of liquids and its unique self-cleaning construction is well suited for even sticky or dirty environments, reliability and accuracy-this is an ideal transmitter. Operating PrincipleThe Unit operates on the principle of buoyancy. During the rise and fall of liquid level, the Float moves and the magnetic field changes & actuates the chain which develops a proportional voltage. The sensed voltage is fed to a transmitter for converting it to a signal of 0-5 V Dc or 4 20 mA. The transmitter can also be incorporated with a digital display or step less adjustable multiple alarm relays (featuring high level alarm, low level alarm, or both & low level pump (or solenoid valve) on & high level off and vice-versa. ConstructionThe transducer consists of a float and guide tube assembly in non-magnetic material to achieve undisturbed flux. The float can be in nylon, PP or SS. No gasket or seals are used and there is only one moving part, the float assuring long trouble free life. Being entirely glandless, there is no possibility of fluid leakage into the transducer. Installation and WiringThe transducer is mounted internally and externally through a chamber by means of a flange connection. External mounting is adopted to overcome limited space within the tank or where mechanical devices operate or where isolation tank is required for regular servicing. The Transducer is precalibrated in the factory and comes to you ready for installation. For operation of level transducer, it has to work in conjunction, with a signal converter which have line or loop powered electronics. Line powered transmitter can be incorporated with a digital display and / or adjustable multiple alarm relays. Loop powered transmitter is employed for remote signaling to a process indicator / controller.

Ideal For

  • Tanks for Oil, Fuel, Milk, Chemicals
  • Pure/Industrial Water
  • Ship/LPG Tanks
  • Pressurized vessels
  • Waste water and sewage treatment plants

Specifications

Measuring range 6 Meters max
Accuracy at range 1000 mm : ± 1% FS
2000 mm : ± 0.5% FS
4000 mm : ± 0.25 %n FS
Installation Top with 80 - 100 NB Flange in SS 304/316/pp/ptf lined
Float 75/100 mm Ø in SS 304/316/pp/ptfe coated
Guide Tube SS / ptfe : 100 oC / PP : 80 oC
SS/ptfe coated 15 kg/cm2g/PP : 1 kg/cm2 g
Enclosure Protection Weather proof to IP 65


Table

Signal Converter 4 wire system 2 Wire System
Electronics Line powered, Nonintegral with Transducer Loop powered, integral with transducer
Input Variable resistance from transducer Variable resistance from transducer
O/P 4-20 mA (Optional 0-20 mA ro 0-5 DC) 4-20 mA
Max. Load 400 Ohms 400 Ohms
Supply 24V DC/220 V AC 24 V DC
Digital Display (Optional) 3 ½ digits (% of Engg. Units)  
Control (Optional) Multiple stepless adjustable, O/P relays rated for 5A, 230V AC  
Version Wall Panel  
Enclosure Protection IP 30/IP 65

Download


Download Detail File : Click Here
View Complete Details

Boiler Dual Control

  • Brand Name Malhotra Make
  • Place of Origin New Delhi, India
boiler dual control for automatic control of waler in boilers and protect the boiler with low level trip.
View Complete Details

Mobray Dual Control

  • Application Industrial
  • Phase Three Phase
  • Power 220V
  • Size 96 x 96 x 110 mm.
  • Accuracy +/- 0.1oC for Temp. and + / - 0.1% for RH.
  • Temperature range -200~1300

We understand that the use of finest grade raw material brings forth high quality product line. In addition to this, we make sure that the material is sourced from the reliable places only. Be it online or cash deposit, the financial operations are carried out only under the stern management, supervision of professionals. To make our payment procedures highly secured, we make use of the leading technologies to avoid any fraud.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us