Post Buy Requirement
MP

Mahavas Precision Controls Pvt. Ltd.

Add Review

Our Products

  1. Industrial Valves 18 Products available
  2. Valves & Valve Fittings 18 Products available
  3. Separators & Strainers 5 Products available
  4. Machines And Equipments 3 Products available
  5. Pumps, Pumping Machines & Parts

    2 Products available
  6. Separating Machines

    2 Products available
  7. Boilers

    2 Products available
  8. Chemical Reactors & Process Tanks

    1 Products available
  9. Process Control Systems & Equipment

    1 Products available
  10. Evaporators & Dryers

    1 Products available
  11. Others Products 3 Products available

Other Products / Services

Leading Manufacturer, Supplier & Retailer of Socket Weld Strainer, Stainless Steel Flow Check Valve, Condensate Return Pump Systems, condensate recovery system and prv valve.

Boiler Condensate Pumps

  • Flash vessel Condensate pump
Introduction to condensate recoverysteam is usually generated for one of two reasons.to produce electricity(co-generation plant)to supply heat for heating system.After giving up its latent heat to heat the process, steam turns to water containing only sensible heat.1kg of steam is condenses completely, 1 kg of condensate is formed at same pr. & temp.Condensate is discharge from plant & equipment through steam trap from higher pressure to lower pr. As a result of this pr. Drop, some of condensate will re- evaporate into flash steam. Condensate pipe contain only 15% flash stem (by mass) as compared to 85% condensate.How we separate the flash steam from condensate, for that we use flash vessel . Principle of working:-the vessel diameter is designed so as to reduce the velocity of fluid in the pipe, the heavier condensate falls to the bottom of flash vessel & drained by suitable steam trap.supplied complete with all required accessories.designed in accordance with ibr code.Condensate is basically distilled water which is ideal for use as boiler feed water.Condensate which is discharge from vessel is collect & return it to deaerator, a boiler feed tank or use it in another process.How condensate return to feed water tank or some other process?this can be done by crps( condensate return pump system)complete framed str. Which makes pump robust.stainless steel internal part.pre-wired, pre-piped pakaged for easy intallation.supplied with condensate flow totaliser.Beside that , we also supply, 1. automatic blow down control (abco)2. dearator head.3. steam trap.
View Complete Details

Socket Weld Strainer

  • Min. Order (MOQ) 1 Piece
  • Brand Name Mahavas Precision
  • End Connection Flange End, Screwed End
  • Material Cast Steel Body With SS Screen (40 Mesh).
  • Media Gas, Water, steam
  • Size/Dimension 15 NB, 20 NB, 25 NB, 40 NB & 50 NB.
  • Max. Temperature 427' C
View Complete Details

Stainless Steel Flow Check Valve

  • Brand Name Precision Controls
  • Pressure 45 Bar
  • Media Water
  • Material Stainless Steel
  • Certification IBR
  • Valve Size 1/2
  • Automation Grade Semi-automatic
  • Corrosion Resistance Yes
  • Coated Yes
  • Condition New
  • Minimum Order Quantity 1 Unit
View Complete Details

Moisture Separator

  • Min. Order (MOQ) 1 Number
  • Material Cast Iron
  • Brand Name Precision Controls
  • Finishing Polished
  • Size 15 NB to 200 NB
  • Capacity 50 Nos. per month
  • Model SEP
View Complete Details

Boiler

  • Min. Order (MOQ) 1 Units
  • Material Iron
  • Application Industrial
  • Capacity (kg/hr) 0-500, 500-1000, 1000-2000, 2000-3000, 6000
  • Automation Grade Semi-Automatic
  • Brand Name Mahavas Presicion
  • Working Pressure (kg/cm2g) 0-5, 5-10, 10-15, 15-20 kg/cm2g
View Complete Details

IBR Steam Boiler

  • Type Three or Two pass, horizontal, smoke(Fire) tube, fully wetback, packaged boiler, conforming to IBR & Non-IBR (Indian Boiler Regulations)
  • Capacity 300 to 7000 kg/h (F & A 100° C)
  • Fuel Wood, Coal, lignite, petcoke, bagasse, husk / other agro waste etc.
  • Working Pr. 7.0, 10.54, 14.0, 17.5 kg/cm2.
  • Design Code Indian Boiler Regulations 1950 (IBR) with latest Amendment/ British Standard (BS: 2790)

Packaged Boiler:Widely used in different industrial areas and engineering plants, are assured of precise dimension and smooth operation The packaged boiler is so called because it comes as a complete package. These are available in different specifications as per the requirement of the clients Once delivered to site, it requires only the steam, water pipe work, fuel supply and electrical connections to be made for it to become operational. Package boilers are generally of shell type with fire tube design so as to achieve high heat transfer rates by both radiation and convection

The features of package boilers are:
  • Small combustion space and high heat release rate resulting in faster evaporation.
  • Large number of small diameter tubes leading to good convective heat transfer.
  • Forced or induced draft systems resulting in good combustion efficiency.
  • Number of passes resulting in better overall heat transfer.
  • Higher thermal efficiency levels compared with other boilers.

These boilers are classified based on the number of passes the number of times the hot combustion gases pass through the boiler. The combustion chamber is taken, as the first pass after which there may be one, two or three sets of fire-tubes. The most common boiler of this class is a three-pass unit with two sets of fire-tubes and with the exhaust gases exiting through the rear of the boiler.

View Complete Details

FIXED And VARIABLE NOZZLE DESUPERHEATER

Variable Nozzle Desuperheater are provided for accurate temperature control & Selection best on process parameters requirement. These are designed, engineered and manufactured in house which ensures high quality.

Fixed Nozzle Desuperheater:
  • The Simplest Design in De super heater family
  • Mainly used when the pressure difference between the main steam line and spray water is high
  • Inline type assembly for steam line size 6" NB and above
  • Mini cooler for steam line size up to 4"
  • Maximum Turn down 4:1

Variable Nozzle Desuperheater:
  • Best Design in Desuperheater family
  • Constant pressure drop across the nozzle
  • High turn down up to 20:1
  • Better downstream temperature control
View Complete Details

PNEUMATIC PRESSURE CONTROLLER

Product Details:

  • Valve mounted, Compact and simple pressure control system
  • Output air pressure upto 3 Kg/Cm2 hence valve positioner not required
  • Can be used directly for pressure reduction or as overflow system. No additional instruments required
  • Totally mechanical, very easy to maintain in-house
  • No electronics, hence not affected by ambient temperature
  • All materials includes sensing bellow are cast AL and SS hence corrosion resistant
  • Can be used with any control valves with any Pneumatic Actuator
  • Very little air consumption

Pressure Control Ranges Available (Higher Pressures on Request)
0.15 TO 0.9 BAR
0.6 TO 3.0 BAR
2.0 TO 9.0 BAR
5.0 TO 15.0 BAR
View Complete Details

Flash Vessel

  • Capacity 0-20 L, 20-100 L, 100-500 L
  • Material FRP, Stainless Steel, Aluminium Alloy
  • Brand Name Mahavas Precision
  • Features Verical Orientation, High Temperature Resistance
  • Max Design Pressure 10-15 bar, 15-20 bar
  • Automation Grade Semi-Automatic
View Complete Details

Condensate Pump

  • capacity 500 Kg/hr to 30 T/hr.
Uses inexpensive Steam or Air for operation. Energy Consumption is proportional to Qty of condensate returned. No cavitation or impeller to get worn out. Total Y eliminates failures seen in earlier mechanical pumps. Only 1 moving part in HT which makes pump maintenance free. Completely framed structure which makes the pump robust. Stainless Steel internal parts.
View Complete Details

Moisture Separators

Sizes Available : 25 NB, 40 NB, 50 NB, 80 NB, 100 NB, & 150 NB
End Connections : Flanged Ends To ANSI 300
Material : Cast Steel ( A 216 Gr, WCB) Other On Request
IBR Certificate : Available For IBR Applications
Larger Sizes : Available On Request
View Complete Details

Condensate Return Pump Systems

Precision Controls offers the field proven CRPS Condensate Recovery Pump System.


Our offering include :

  • Widest range (capacity) available from 500 Kg/hr to 30 T/hr.
  • Uses inexpensive Steam or Air for operation.
  • Energy Consumption is proportional to Qty of condensate returned.
  • No cavitation or impeller to get worn out.
  • Total Y eliminates failures seen in earlier mechanical pumps.
  • Only 1 moving part in HT which makes pump maintenance free.
  • Completely framed structure which makes the pump robust.
  • Stainless Steel internal parts.
  • Pre-wired, pre-piped package for easy installation.
  • Components of superior make makes the system highly reliable.
  • Supplied with Condensate Flow Totaliser.
  • Each CRPS functionally tested for 72 hours before dispatch.
  • Unique 2 year comprehensive on-site warranty.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us