Post Buy Requirement
ME
Pune, Maharashtra, India
Add Review

Transformers #553327

Dry Type Transformers

With increasing importance of safety and environmental aspect in modernized and compact commercial applications, Dry type transformer demand is increasing.
There is no oil used in the Dry type transformers. A special type of fire resistant insulation is used to reduce the fire risk considerably.
Major application areas -- Mining, hotels, high rise buildings, hospitals, malls, shipping.
Mahati has following two types of dry type transformers to offer :
  • cast resin
  • vacuum impregnated
Mahati make dry type transformers are now in use for over five years. Range:- KVA rating : 100KVA to 5000KVA (36KV class).
View Complete Details

Laddle Arc Transformers

This is a process to refine the steel melt (obtained generally from Direct Arc furnaces). This transformer can be at 50 cycles or higher frequencies (where rectifier inverter combo is used). Mahati make Laddle Transformers range-Voltage: 3.3, 6.6, 11, 22, 33KVKVA : 1000KVA to 15000KVA

View Complete Details

Power Transformers

  • No Load losses minimized by using CRGO steel.
  • The Core assembly of step lap construction has minimum losses.
  • Core is tightly pressed and bound by glass reinforced resin tapes.
  • Proper insulation is provided between clamping channels and the entire assembly is insulated from tank by insulating packing.
  • Prime CRGO lamination is used. Cut and assembled to achieve a near perfect-circle core cross section, resulting in the efficient use of materials plus a lighter, more compact, high performance transformer
  • Welding process produces deep penetration welds, virtually eliminating leakage from welded tank joints.
  • Inside tank surfaces are sand blasted and painted with heat resistant paint.
  • Transformer exterior coated to a minimum thickness of 3 mils; this coating has superior endurance characteristics.
  • Detachable radiators with/without fansPressed and vacuum treated coils.
  • Welding process produces deep penetration welds, virtually eliminating leakage from welded tank joints.
  • Inside tank surfaces are sand blasted and painted with heat resistant paint. Transformer exterior coated to a minimum thickness of 3 mils; this coating has superior endurance characteristics.
  • Detachable radiators with/without fansPressed and vacuum treated coils of prime quality are used and duly pressure tested.
  • OLTCs and OCTCs are of Easun MR/CTR. Recently for an export order, dry type OLTCs were used.the right of this text.

Key Customers

Steel industriesSugar FactoriesAuto IndustriesMilitary engineering servicesAll HV & EHV consumersState electricity boardsCo-genertion plants


View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Transformers from Pune, Maharashtra by Mahati Electrics
Post Buy Requirement
ME
Add Review

Our Products

  1. Transformers 3 Products available
  2. Transformers And Transformer Parts

    1 Products available
  3. Testing Equipment

    1 Products available
  4. Industrial Ovens & Furnaces

    1 Products available
  5. Others Products 2 Products available

Transformers

Our Complete range of products are Dry Type Transformers, Laddle Arc Transformers and Power Transformers.

Dry Type Transformers

With increasing importance of safety and environmental aspect in modernized and compact commercial applications, Dry type transformer demand is increasing.
There is no oil used in the Dry type transformers. A special type of fire resistant insulation is used to reduce the fire risk considerably.
Major application areas -- Mining, hotels, high rise buildings, hospitals, malls, shipping.
Mahati has following two types of dry type transformers to offer :
  • cast resin
  • vacuum impregnated
Mahati make dry type transformers are now in use for over five years. Range:- KVA rating : 100KVA to 5000KVA (36KV class).
View Complete Details

Laddle Arc Transformers

This is a process to refine the steel melt (obtained generally from Direct Arc furnaces). This transformer can be at 50 cycles or higher frequencies (where rectifier inverter combo is used). Mahati make Laddle Transformers range-Voltage: 3.3, 6.6, 11, 22, 33KVKVA : 1000KVA to 15000KVA

View Complete Details

Power Transformers

  • No Load losses minimized by using CRGO steel.
  • The Core assembly of step lap construction has minimum losses.
  • Core is tightly pressed and bound by glass reinforced resin tapes.
  • Proper insulation is provided between clamping channels and the entire assembly is insulated from tank by insulating packing.
  • Prime CRGO lamination is used. Cut and assembled to achieve a near perfect-circle core cross section, resulting in the efficient use of materials plus a lighter, more compact, high performance transformer
  • Welding process produces deep penetration welds, virtually eliminating leakage from welded tank joints.
  • Inside tank surfaces are sand blasted and painted with heat resistant paint.
  • Transformer exterior coated to a minimum thickness of 3 mils; this coating has superior endurance characteristics.
  • Detachable radiators with/without fansPressed and vacuum treated coils.
  • Welding process produces deep penetration welds, virtually eliminating leakage from welded tank joints.
  • Inside tank surfaces are sand blasted and painted with heat resistant paint. Transformer exterior coated to a minimum thickness of 3 mils; this coating has superior endurance characteristics.
  • Detachable radiators with/without fansPressed and vacuum treated coils of prime quality are used and duly pressure tested.
  • OLTCs and OCTCs are of Easun MR/CTR. Recently for an export order, dry type OLTCs were used.the right of this text.

Key Customers

Steel industriesSugar FactoriesAuto IndustriesMilitary engineering servicesAll HV & EHV consumersState electricity boardsCo-genertion plants


View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us