Post Buy Requirement
ME
Pune, Maharashtra, India
Add Review

Other Products / Services #553327

Submerged Arc

  • Using On Load Tap Changers
  • The OLTCs select taps on regulating winding on the furnace transformer
  • A separate auto transformer is provided and the output tap is selected by OLTC.
  • In the auto transformer control there are two construction variants :
  • 1. All in one tank
  • 2. Furnace in one and auto + OLTC in other
Manufacturing Range
  • Both single phase and three phase versions.
  • Self regulating winding type
  • Regulation by separate auto transformer
  • Primary voltage : 3.3/ 6.6 / 11/ 22/ 33 KV
  • Secondary voltage: as per process requirement
  • KVA range - 1 phase 500 KVA to 18000 KVA3 phase 1000 KVA to 60000 KVA
View Complete Details

Air Core Reactors

  • Application Electricals Use
  • Voltage AC
  • Frequency 50hz, 60hz
  • Automatic Grade Automatic
  • Warranty 2yrs
  • Phase Type Double Phase
  • Coolling System Air Cooling

These are used for various applications and are made in shunt or series types. The construction features further categorize them as- Air core type air cooled.

View Complete Details

Electrostatic Slag Refining

This is a modern and special steel manufacturing processor for high quality steel required in special application like nuclear, missile, battle tank, Ships etc.

The electrical equipment consists of a high current single phase transformer which in our manufacturing program and a very sensitive high current and medium voltage regulator which has a moving brush on the LV helical winding giving a very fine voltage control. Range:- up to 40KA secondary current
View Complete Details

Induction Furnace

Mains frequency

These are used for melting of metal however recently the secondary supply of specified voltage is directly fed to the induction furnace coil.

Medium frequency

The secondary is fed to a rectifier inverter combo which increase the frequency to medium frequency at designe d voltages which then is fed to the furnace. We make all desired types including special ones like the 12 pulse, 24 pulse versions. The various combination are :

  • Single transformers with 2 LVs (star & delta)
  • Two transformers in one tank to give 12 pulse output
  • Four transformers in one tank to give 24 pulse output.
Range:Voltage : 3.3, 6.6, 11, 22, 33KVKVA : 250 KVA to 16000 KVAInverter output - 6 pulse, 12 pulse and 24 pulse.
View Complete Details

Specialised Testing Equipments

We have manufactured equipments for hydro status up to 300 MW. We have manufactured H.V test kits up to 100 KV
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by Mahati Electrics from Pune, Maharashtra.
Post Buy Requirement
ME
Pune, Maharashtra, India
Add Review

Other Products / Services #553327

Submerged Arc

  • Using On Load Tap Changers
  • The OLTCs select taps on regulating winding on the furnace transformer
  • A separate auto transformer is provided and the output tap is selected by OLTC.
  • In the auto transformer control there are two construction variants :
  • 1. All in one tank
  • 2. Furnace in one and auto + OLTC in other
Manufacturing Range
  • Both single phase and three phase versions.
  • Self regulating winding type
  • Regulation by separate auto transformer
  • Primary voltage : 3.3/ 6.6 / 11/ 22/ 33 KV
  • Secondary voltage: as per process requirement
  • KVA range - 1 phase 500 KVA to 18000 KVA3 phase 1000 KVA to 60000 KVA
View Complete Details

Air Core Reactors

  • Application Electricals Use
  • Voltage AC
  • Frequency 50hz, 60hz
  • Automatic Grade Automatic
  • Warranty 2yrs
  • Phase Type Double Phase
  • Coolling System Air Cooling

These are used for various applications and are made in shunt or series types. The construction features further categorize them as- Air core type air cooled.

View Complete Details

Electrostatic Slag Refining

This is a modern and special steel manufacturing processor for high quality steel required in special application like nuclear, missile, battle tank, Ships etc.

The electrical equipment consists of a high current single phase transformer which in our manufacturing program and a very sensitive high current and medium voltage regulator which has a moving brush on the LV helical winding giving a very fine voltage control. Range:- up to 40KA secondary current
View Complete Details

Induction Furnace

Mains frequency

These are used for melting of metal however recently the secondary supply of specified voltage is directly fed to the induction furnace coil.

Medium frequency

The secondary is fed to a rectifier inverter combo which increase the frequency to medium frequency at designe d voltages which then is fed to the furnace. We make all desired types including special ones like the 12 pulse, 24 pulse versions. The various combination are :

  • Single transformers with 2 LVs (star & delta)
  • Two transformers in one tank to give 12 pulse output
  • Four transformers in one tank to give 24 pulse output.
Range:Voltage : 3.3, 6.6, 11, 22, 33KVKVA : 250 KVA to 16000 KVAInverter output - 6 pulse, 12 pulse and 24 pulse.
View Complete Details

Specialised Testing Equipments

We have manufactured equipments for hydro status up to 300 MW. We have manufactured H.V test kits up to 100 KV
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us