Our offered Product range includes Epoxy Resin Cast Potential Transformer, Outdoor Oil Immersed Potential Transformer, low voltage current transformers, Epoxy Resin Cast Voltage Transformer and Outdoor Oil Cooled Distribution Transformers.

Epoxy Resin Cast Potential Transformer

Epoxy Resin Cast Potential (Voltage) Transformers are dry type transformers and may be used for indoor and outdoor applications. Their key function is to step down voltage in an electrical system. These class of transformers are manufactured using high quality epoxy resin which is a strong synthetic polymer developed from epoxide chemicals. The scientifically proven insulation properties of epoxy make it an excellent material for manufacturing dry type resin cast potential transformers.

Both the Potential Transformer & Voltage Transformer are the same. The only difference is their names. The technical meaning of the words - Potential or Voltage – refer to the same thing.

Macroplast manufactures epoxy resin cast voltage transformers up to 33 KV system voltage. Our resin cast PTs are are fitted on metering panels or cubicles and in most circumstances used indoors. They may be used for Outdoor applications if they are enclosed either in a sealed metal tank or cubicle. The energy meter or measuring instrument is also placed within the same contraption. Epoxy resin cast voltage transformers can also be used outdoors provided they are enclosed in a hermetically sealed metal tank.

View Complete Details

Outdoor Oil Immersed Potential Transformer

We manufacture outdoor oil immersed potential (voltage) transformer without top expansion tank upto 33kv system voltage. This design has a single tank. The core and windings are contained in the lower tank. The primary winding is taken through the ht insulator to be connected to the primary terminal arranged at the top of the ht insulator. The secondary windings are connected to secondary terminals placed on the lower tank.
View Complete Details

Low Voltage Current Transformers

  • Type Low Voltage Transformer
  • Certification ISO 9001:2008 Certified
  • Color Green, Grey
  • Frequency 50hz
  • Condition New
  • Output Type AC Single Phase
  • Automatic Grade Automatic
  • Production Power 250-500kw, 50-100kw

Low Voltage Current transformers may be either Tape Wound or Epoxy Resin Cast. They may be either Ring Type or Wound Primary Type. For lower ratio, high accuracy CTs, Wound Primary Construction is preferred. For higher ratio CTs, Ring Type Construction is preferred from the economical point of view. Ring Type CTs are most economical if the primary current is 200 A or more. For primary currents lower than 200 A, Wound primary CTs are most economical. Low Voltage (LV) or Low Tension (LT) Current Transformers are one and the same thing. These type of transformers are usually insulated with Epoxy Resin or Cotton Tape and are primarily used in electrical systems for metering and protection. The standard secondary output from such transformers are 1 Ampere or 5 Amperes.

Tape wound current transformers are widely used in switch gears, distribution systems, electrical generators, indoor or outdoor control panels and control instruments.

 

Macroplast manufactures Low Voltage Current Transformers of 1, 0.5, 0.2, 0.2s accuracy class. Our LT-CTs are constructed with only a single secondary winding. We possess the expertise to manufacture these either in tape wound or resin cast type depending on client specifications and requirements.

View Complete Details

Epoxy Resin Cast Voltage Transformer

  • Type High Voltage Transformers
  • Color Red
  • Operating Type Automatic
  • Cooling Type Air Cooling
  • Power 50-75kw, 100-250kw
  • Condition New
  • Output Type AC Single Phase, AC Three Phase
We are the main supplier of this product.
View Complete Details

Outdoor Oil Cooled Distribution Transformers

  • Type Oil Cooled Power Transformer
  • Certification ISO 9001:2008 Certified
  • Application Industrial Use
  • Color Grey
  • Condition New
  • Output Type AC Single Phase, DC
  • Automatic Grade Automatic
  • Tensile Strength 175-200Mpa, 75-100Mpa
  • Cooling System Oil Cooled
  • Production Power 750-1000kw
  • Temperature Capacity High Temperature, Low Temperature

distribution transformer derives its name from its usage in the electricity grid where its function is to step down the electrical voltage in the distribution line to a level that can be used by electricity consumers. Distribution transformers are used by power utilities to distribute electricity to domestic and commercial customers at a voltage that can be used by them for various purposes.

distribution transformers refer to a large family of transformers and includes pole mounted transformer, pad mounted transformer, single phase transformer, three phase transformers. The design, construction and functionality of each of these sub-category of distribution transformers are different from one another. Distribution transformer manufacturers follow their own design and construction features to manufacture distribution transformers. The overall objective is to meet client objective and customize it according to the requirements in the electrical system.

macroplast is amongst the leading names of distribution & power transformer manufacturers in india. We manufacture outdoor onan cooled distribution transformers upto 2500 kva with system voltage of upto 33 kv. In the few years, we have supplied distribution transformers to several state utilities, government bodies, and leading private organizations. We have the right knowledge, years of experience and technical capabilities in distribution transformer manufacturer in india.

the key features of our distribution transformers are:

  • stack core surrounded by primary and secondary windings housed in a steel tank

  • primary and secondary terminals or studs

  • high voltage and low voltage insulators

  • off-load tap switch

  • silica gel breather

  • expansion tank or conservator

  • oil level indicator

  • thermometer pocket

  • oil filling plug

  • oil drain valve

  • arcing horns

View Complete Details

Residual Voltage Transformers

  • Type Residual Voltage Transformer
  • Certification ISO 9001:2008 Certified
  • Color Grey
  • Condition New
  • Output Type AC Single Phase
  • Automatic Grade Automatic
  • Cooling System Air Cooling

Residual Voltage Transformers (RVTs) are category of instrument transformers which are in electrical systems to protect capacitor banks from earthing faults and prevent damage. The main function of these class of instrument transformers is to detect neutral to ground fault conditions and discharge the capacitor banks as and when required automatically. In an electrical system in normal working conditions, the windings of an RVT will have no voltage output. On the other hand, in the event of an earth fault a voltage will be developed across the open delta winding of the transformer which will activate the relays and cut the power connection thereby protecting the measuring equipments from damage.

The function of RVTs is similar to voltage transformers in some areas. However their and utility is different from one another. It is probably one of the reasons why many people consider RVTs as a sub-group of voltage transformers.

Macroplast manufactures Residual Voltage Transformers for varied system voltages. The most common systems voltages are 11 KV, 33 KV system voltages in which five limb core construction is employed instead of conventional three limb construction. The outer two limbs carries the residual flux and the secondary windings are connected in open delta fashion.

View Complete Details

Top Tank Outdoor Oil Immersed Potential Transformer

We manufacture top tank outdoor oil immersed potential (voltage) transformer upto 132kv system voltage. The top tank acts as an expansion chamber for the transformer. This kind of design has two tanks. The core and windings are contained in the lower tank. The primary winding is taken through the ht insulator to be connected to the primary terminal arranged on the top tank. The secondary windings are connected to secondary terminals placed on the lower tank. In this design, the top tank provides space for expansion of oil
View Complete Details

Outdoor Onan Cooled Distribution Transformers

Distribution transformer derives its name from its usage in the electricity grid where its function is to step down the electrical voltage in the distribution line to a level that can be used by electricity consumers. Distribution transformers are used by power utilities to distribute electricity to domestic and commercial customers at a voltage that can be used by them for various purposes.

Distribution transformers refer to a large family of transformers and includes pole mounted transformer, pad mounted transformer, single phase transformer, three phase transformers and underground transformer. The design, construction and functionality of each of these sub-category of distribution transformers are different from one another. Distribution transformer manufacturers follow their own design and construction features to manufacture distribution transformers. The overall objective is to meet client objective and customize it according to the requirements in the electrical system.

Macroplast is amongst the leading names of distribution transformer manufacturers India. We manufacture outdoor ONAN Cooled Distribution Transformers upto 2500 KVA with system voltage of upto 33 KV. In the few years, we have supplied distribution transformers to several state utilities, government bodies, and leading private organizations. We have the right knowledge, years of experience and technical capabilities in distribution transformer manufacturer in India.

The key features of our Distribution transformers are:

• Stack core surrounded by Primary and Secondary windings housed in a steel tank• Primary and Secondary terminals or studs• High Voltage and Low Voltage Insulators• Off-load tap switch• Silica Gel Breather• Expansion Tank or Conservator• Oil Level Indicator• Thermometer Pocket• Oil Filling Plug• Oil Drain Valve• Arcing Horns

View Complete Details

Low Tension Current Transformers

Low Voltage Current transformers may be either Tape Wound or Resin Cast. They may be either Ring Type or Wound Primary Type. For lower ratio, high accuracy CTs, Wound Primary Construction is preferred. For higher ratio CTs, Ring Type Construction is preferred from the economical point of view. Ring Type CTs are most economical if the primary current is 200 A or more. For primary currents lower than 200 A, Wound primary CTs are most economical. Low Voltage (LV) or Low Tension (LT) Current Transformers are one and the same thing. These type of transformers are usually insulated with Epoxy Resin or Cotton Tape and are primarily used in electrical systems for metering and protection.
View Complete Details

Low Tension Current Transformer

  • Usage Metering/ Protection
  • Phase 3
  • Warranty 1 Year
  • System Voltage 720V maximum
  • Feature Flawless performance, Easy operation and Less wear and tear
  • Used For Industrial purpose and Commercial purpose
  • Ambient temperature -25°C to +40°C

Construction Feature :

  • Secondary Wire
  • Core And Widing
  • Window For Primary
  • Secondary Terminals
  • Mounting Bracket

Low Tension Current Transformer Graph


Download Detail File : Click Here
View Complete Details

Epoxy Resin Cast Current Transformer

Epoxy Resin Cast Current Transformer is a dry type transformer in which the internal windings and coils of the transformer are coated with epoxy resin for Insulation purpose. It is widely used in instrument transformers where the primary function is to step down high currents and voltage. In an epoxy resin cast current transformer, the windings consist of high quality electrolytic grade copper which are wound around the core and insulated using a layer of fiberglass mat or quartz powder before being cast with an epoxy resin in an automated vacuum casting machine to provide the necessary insulation.

Epoxy is a strong synthetic thermosetting polymer which is made from various epoxide materials. Epoxy is widely used in various industries like adhesive industry, synthetic paints, casting industry amongst others. In the electrical industry, it is primarily used for the process of insulation. Its chemical composition offers excellent insulation properties and is therefore widely used in the transformer industry for making dry type resin cast transformers.

The function of resin cast current transformers are similar to oil filled current transformers. The reasons why some businesses prefer to use it is because they are better in handling moisture, there is no leakage and pilferage of oil, and they are far more compact in size compared to oil filled transformers

Macroplast manufactures epoxy resin cast current transformers up to 33 KV system voltage. These are manufactured using high grade epoxy resin polymers and other necessary raw materials. Our resin cast current transformers can be used for both indoor and outdoor usage. For indoor usage, they are placed inside panels or cubicles which are known as indoor metering cubicles. For outdoor usage, they are enclosed in a hermetically sealed metal tank or they may be installed in High Voltage Metering Cubicles. We have years of experience in manufacturing high quality resin cast CTs.

View Complete Details

Residual Voltage Transformer

Residual Voltage Transformers (RVTs) are a category of instrument transformers which are used in electrical systems to protect capacitor banks from earthing faults and prevent damage. The main function of these class of instrument transformers is to detect neutral to ground fault conditions and discharge the capacitor banks as and when required automatically. In an electrical system in normal working conditions, the windings of an RVT will have no voltage output. On the other hand, in the event of an earth fault a voltage will be developed across the open delta winding of the transformer which will activate the relays and cut the power connection thereby protecting the measuring equipments from damage.

The function of RVTs is similar to voltage transformers in some areas. However their and utility is different from one another. It is probably one of the reasons why many people consider RVTs as a sub-group of voltage transformers.

Macroplast manufactures Residual Voltage Transformers for varied system voltages. The most common systems voltages are 11 kv, 33kv system voltages in which five limb core construction is employed instead of conventional three limb construction. The outer two limbs carries the residual flux and the secondary windings are connected in open delta fashion.

View Complete Details

Epoxy Resin Cast Potential Transformers

  • Brand Name MPL
  • Usage Indoor Application Inside The Panels
  • Phase Single or Three Phase
  • Usage Indoor Type
  • Voltage upto 33 KV

Epoxy Resin Cast Potential (Voltage) Transformers are dry type transformers and may be used for indoor and outdoor applications. Their key function is to step down voltage in an electrical system. These class of transformers are manufactured using high quality epoxy resin which is a strong synthetic polymer developed from epoxide chemicals. The scientifically proven insulation properties of epoxy make it an excellent material for manufacturing dry type transformers.

Both the Potential Transformer & Voltage Transformer are one and the same. We may use either Potential instead of Voltage and vice-versa.

Macroplast manufactures epoxy resin cast voltage transformers up to 33 KV system voltage. Our resin cast PTs are are fitted on metering panels or cubicles and in most circumstances used indoors. They may be used for Outdoor applications if they are enclosed either in a sealed metal tank or cubicle. The energy meter or measuring instrument is also placed within the same contraption. Epoxy resin cast voltage transformers can also be used outdoors provided they are enclosed in a hermetically sealed metal tank.

Additional Information:

Payment Terms : L/C, T/T

Packaging Details : Sea Worthy Wooden Box Packing

View Complete Details

Indoor Epoxy Resin Cast Voltage Transformers

  • Phase Three Phase
  • Cooling Type Oil Cooled
  • Phase Single Phase, three Phase
  • Rated Power: 33kv
  • Storage temperature -40 To +70 Degree Celsius
  • Rated frequency 50hz-60hz
  • Power Factor 0.8 Lagging

Epoxy Resin Cast Potential (Voltage) Transformers are dry type transformers and may be used for indoor and outdoor applications. Their key function is to step down voltage in an electrical system. These class of transformers are manufactured using high quality epoxy resin which is a strong synthetic polymer developed from epoxide chemicals. The scientifically proven insulation properties of epoxy make it an excellent material for manufacturing dry type transformers.

Both the Potential Transformer & Voltage Transformer are one and the same. We may use either Potential instead of Voltage and vice-versa.

Macroplast manufactures epoxy resin cast voltage transformers up to 33 KV system voltage. Our resin cast PTs are fitted on metering panels or cubicles and in most circumstances used indoors. They may be used for Outdoor applications if they are enclosed either in a sealed metal tank or cubicle. The energy meter or measuring instrument is also placed within the same contraption. Epoxy resin cast voltage transformers can also be used outdoors provided they are enclosed in a hermetically sealed metal tank.

View Complete Details

Outdoor Oil Immersed Live Tank Current Transformer

Outdoor Oil Immersed Live Tank Current Transformer is a type of electrical current transformer in which the core of the transformer along with its secondary windings is placed in the top tank. They are also known an outdoor oil filled current transformers.

Live Tank Current Transformers are different from Dead Tank Current Transformers in their design and tank fabrication. At a macro level, the basic functionality of both remain the same, which is to step down high voltage current to low voltage current for measurement by energy meters or other such instruments.

In an outdoor oil immersed live tank current transformer, the core and secondary windings are insulated from high voltage with insulating material and placed in the top tank. In Live Tank CTs, the primary conductor is shorter in length which makes it stronger to withstand high short circuit currents. Also, the primary winding in Live Tank Current transformers is homogeneously distributed around the core to create a current transformer which has low reactance and excellent transient performance.

Live Tank Current transformers are smaller and compact in size compared to Dead Tank Current Transformers. They are also more economical to be produced and are hence cheaper than Dead Tank CTs.

Macroplast manufactures oil filled live tank Current transformers upto 132 KV system voltage. The Live tanks CTs manufactured by us have cores, primary and secondary windings arranged in the top tank of the transformer body. The primary windings are then connected to the primary terminals which are also arranged in the top tank. The secondary windings are taken through the HT insulator to the bottom mounting base. The mounting base has arrangement for secondary terminals inside the secondary terminal box

View Complete Details

Outdoor Oil Immersed Dead Tank Current Transformer

Outdoor Oil Immersed Dead Tank Current Transformer is a type of current transformer in which both the core and secondary windings of the transformer are placed in the bottom tank. This bottom tank is then earthed to make it dead, and hence the name dead tank transformer. In Dead Tank CTs, the primary winding is made to pass through an insulator constructed of porcelain material. It is then connected to the bottom tank and insulated from the tank and the cores of the transformer. The internal design of Dead Tank Current Transformers ensure the primary conductor produces maximum mechanical force during short time dynamic current to prevent damage to internal insulation. Outdoor oil immersed dead tank current transformer is also known as outdoor oil filled current transformer. Both have same functionalities.

The biggest advantage of Oil Filled Dead Tank Current Transformers in comparison to Live Tank Current transformer is its high seismic strength. Since the core and secondary windings are place in the lower tank, the stability of Dead tank CTS is much stronger. Also, it is easier to transport them from the place of manufacturing to the place of installation with lesser chances of breakage or damage. Dead Tank Oil Filled Current transformers are however expensive and heavy compared to Live tank current transformers.

Macroplast manufactures outdoor oil filled dead tank current transformer of various system voltages. In our Dead tank CT design, the cores, primary and secondary windings are arranged in the lower tank. The primary windings are taken to the top tank through HT insulators and connected to the primary terminals. The secondary windings are connected to the secondary terminals arranged inside the secondary terminal box placed on the bottom tank.

The Dead Tank design is preferred where the No. of CT Cores are more because more cores means more weight and lesser stability. In such cases, Live Tank CTs are not preferred from Technical Point of view.

View Complete Details

Resin Cast Potential Transformers

  • Phase 2
  • Application Machines, Control Panels, Industry
  • Special Function Alkali, Oil and Other, Salt, Prevent Acid
  • Rated load ≤30VA
  • Rated frequency 50Hz or 60Hz
  • Rated secondary current 5A or 1A

The resin cast PTs are normally used fo indoor application inside the panels.The  resign cas PTs cab be used for outdoor application also provided it is enclosed in hermetically sealed metal tank.

Construction Feratures

S No DESCRIPTION
1 PRIMARY TERMINAL
2 BODY
3 SECONDARY TERMINAL
4 PRIMARY NEUTRAL TERMINAL
5 NEUTRAL SHORTING LINK
6 CORE
7 MOUNTING CHANNEL
8 CORE CLAMPING ANGLE
9 EARTHING TERMINAL
10 LT HRC FUSE
   
   
S No DESCRIPTION
1 PRIMARY TERMINAL
2 BODY
3 SECONDARY TERMINAL
4 PRIMARY NEUTRAL TERMINAL
5 NEUTRAL EARTH LINK
6 CORE
7 MOUNTING CHANNEL
8 PRIMARY NEUTRAL EARTHING TERMINAL
9 EARTHING TERMINAL

Download Detail File : Click Here

Technical Information For Potential Transformers

type: Resin Cast. Outdoor. Oil Cooled          
Nominal System Voltage (kv) 11 33 66 132 220
Highest System Voltage (Kv) 12 36 72.5 145 245
Power Frequency withstand voltage( 1 min Kv) 28 70 140 275 460
impulse withstand voltage (KvP) 75 170 325 650 1050
Rtaed Burden 10 VA TO 500VA
Rated frequency (Hz) 50 50 50 50 50
Creepage Distance Phase To Earth (m.m) 300 900 1815 3625 6125
Rated secondary voltage          
R.ted voltage factor 110 Volt 110√3 Volt
Accuracy class (IS/IEC standard) 1.2 Cont G 1.5 for 30 Second
  0.2,D.5,1.0 For Metetring ¢ 3P,5P, 6P For Protection
View Complete Details

Distribution Transformer

  • Phase 415/11000
  • Frequency 50 Hz
  • Type Oil Filled With ONAN (Oil Natural Air Natural) Cooling
  • Application Industrial
  • Ratings 16 KVA to 400 KVA.
  • Feature Rust resistance
  • Transformer As per Size

Details :

  • Distribution Transformers are utilised for supplying the Consumer Loads.
  • Steps down the High Voltage to Low Voltage.
  • With or without Off-Load Tap Changer (OLTC).
  • Single Phase OR Three Phase.
  • The Distribution Transformers that MACROPLAST manufactures consists of following


Features :

  • Stacked Core surrounded by Primary & Secondary Windings housed in a Steel Tank.
  • Primary & Secondary Terminals or Studs.
  • High Voltage & Low Voltage Insulators/Bushings.
  • Off-Load Tap Switch.
  • Silica Gel Breather.
  • Expansion Tank or Conservator.
  • Oil Level Indicator.
  • Thermometer Pocket.
  • Oil Filling Plug.
  • Oil Drain Valve.
  • Arcing Homs.

Technical Information For Distribution Transformers

Type Outdoor,Oil Filled.  
Designation ONAN Cooled.  
Rated Output(KVA) 16 to 400.  
Primary Voltage(KY)                                                             11 15 11 15
Nominal System Voltage(KV) 11 15 11 15
Highest System Voltage (KV) 12 17.5 12 17.5
Power Frequency \Withstand Voltage (KV) for 60 sec. 28 38 28 38
Impulse Withstand Voltage (KVp) 75 95 75 95
Secondary Voltage (K\V)    
Voltage at No Load (KV) 0.433 0.400 0.43 0.4
Power Frequency Withstand Voltage (KV) for 60 sec. 3 3 3 3
Vector Group Dyn-11 Dyn-5 Dyn-11 Dyn-5
N o. of Phase 3 3
Rated Frequency (Hz) 50 50
Connection Delta/Star Delta /Star
View Complete Details

Split Core Type Current Transformer

  • Type Current Transformers
  • Usage Control Panels
  • Color Grey, White
  • Frequency 200-400Hz, 50-100Hz
  • Condition New
  • Tensile Strength 50-75Mpa, 75-100Mpa
  • Feature Easy To Install, Electrical Porcelain
  • Cooling System Air Cooling
  • Current Type Double Phase
  • Production Power 500-750kw, 750-1000kw

split core current transformers are just like the typicalcurrent transformer, thesplit-core current transformermeasures alternatingcurrent flowing through a conductor. The electrical performance ofsplit-core current transformersis as good as the continuous toroidal core transformer.

split core current transformers may be either ring type or rectangular type. Suitable for higher ratio cts, ring type construction is preferred from the economical point of view. These type of transformers are usually insulated with pvc casing and are primarily used in electrical systems for metering and protection. The standard secondary output from such transformers are 1 ampere or 5 amperes.

split core current transformers are widely used in switch gears, distribution systems, electrical generators, indoor or outdoor control panels and control instruments.

macroplast manufactures split core current transformers of 1, 0.5, 0.2, 0.2s accuracy class. Our cts are constructed with only a single secondary winding. We possess the expertise to manufacture these cts depending on client specifications and requirements.

View Complete Details

Outdoor Oil Filled Voltage Transformers

  • Type High Voltage Transformers
  • Certification ISO 9001:2008 Certified
  • Color Grey, White
  • Frequency 60hz
  • Operating Type Automatic
  • Cooling Type Air Cooling
  • Power 500-750kw, 750-1000kw
  • Condition New
  • Output Type AC Single Phase

outdoor oil filled potential (voltage) transformer is a voltage transformer design in which there are two tanks. This is a special kind of voltage transformer and is used generally for higher system voltages upto 132 kv.

the lower tank consist of primary windings, secondary windings & core. The upper tank is used due to the bushing limitations to withhold graded insulation of hv windings. Other purpose to provide a conservator tank is for oil expansion during high temperatures.

macroplast manufactures top tank outdoor oil filled potential (voltage) transformer upto 132kv system voltage. The top tank acts as an expansion chamber for the transformer. This kind of design has two tanks. The core and windings are contained in the lower tank. The primary winding is taken through the ht insulator to be connected to the primary terminal arranged on the top tank. The secondary windings are connected to secondary terminals placed on the lower tank. In this design, the top tank provides space for expansion of oil

oil filled voltage transformer is a type of instrument transformer whose function is to step down voltage in an electrical system to a level measurable by various metering instruments.

we manufacture outdoor oil filled potential (voltage) transformer without top expansion tank upto 33kv system voltage. This design has a single tank. The core and windings are contained in the lower tank. The primary winding is taken through the ht insulator to be connected to the primary terminal arranged at the top of the ht insulator. The secondary windings are connected to secondary terminals placed on the lower tank.

the outdoor oil filled potential transformer without top conservator tank is generally used for medium system voltages like 11, 33 kv etc. In such lower system voltages, uniform insulation is sufficient to withstand high voltages and is feasible from both technical & economical point of view.

View Complete Details

Outdoor Cycloaliphatic Resin Cast Voltage Transformer

  • Type High Voltage Transformers
  • Certification ISO 9001:2008 Certified
  • Color Grey, White
  • Frequency 60hz
  • Operating Type Automatic, Semi Automatic
  • Cooling Type Air Cooling
  • Power 250-500kw, 500-750kw
  • Condition New
  • Output Type AC Single Phase

Cycloalliphatic Resin Cast Potential (Voltage) Transformers are dry type transformers and are used for outdoor applications. Their key function is to step down voltage in an electrical system. These class of transformers are manufactured using high quality resin which is a strong synthetic polymer developed from epoxide chemicals. The scientifically proven insulation properties of resin make it an excellent material for manufacturing dry type transformers.

Both the Potential Transformer & Voltage Transformer are one and the same. We may use either Potential instead of Voltage and vice-versa.

Macroplast manufactures cycloalliphatic resin cast voltage transformers up to 33 KV system voltage. Our cycloaliphatic resin cast PTs are used outdoors. They are used for Outdoor applications. The energy meter or measuring instrument is also placed within the same contraption.

View Complete Details

Outdoor Cycloaliphatic Current Transformer

  • Type Current Transformers
  • Certification ISO 9001:2008 Certified
  • Usage Industrial Use
  • Color Grey, White
  • Operating Type Automatic
  • Condition New
  • Tensile Strength 50-75Mpa, 75-100Mpa
  • Feature Easy To Install, Proper Working
  • Cooling System Air Cooling
  • Current Type Double Phase
  • Production Power 500-750kw, 750-1000kw

Cycloalliphatic Resin Cast Current Transformer is a dry type transformer in which the internal windings and coils of the transformer are coated with cycloalliphatic resin for Insulation purpose. It is widely used in instrument transformers where the primary function is to step down high currents and voltage. In a cycloalliphatic resin cast current transformer, the windings consist of high quality electrolytic grade copper which are wound around the core and insulated using a layer of fiberglass mat or quartz powder before being cast with a cycloalliphatic resin in an automated vacuum casting machine to provide the necessary insulation.

Resin is a strong synthetic thermosetting polymer which is made from various epoxide materials. Resin is widely used in various industries like adhesive industry, synthetic paints, casting industry amongst others. In the electrical industry, it is primarily used for the process of insulation. Its chemical composition offers excellent insulation properties and is therefore widely used in the transformer industry for making dry type resin cast transformers.

The function of resin cast current transformers are similar to oil filled current transformers. The reasons why some businesses prefer to use it is because they are better in handling moisture, there is no leakage and pilferage of oil, and they are far more compact in size compared to oil filled transformers

Macroplast manufactures Outdoor, Dry Type, Cycloalliphatic Resin Cast Current Transformers up to 33 KV system voltage. These are manufactured using high grade resin polymers and other necessary raw materials. Our cycloaliphatic resin cast current transformers can be used for outdoor usage. We have 35 years of experience in manufacturing high quality resin cast CTs.

View Complete Details

Resin Cast Current Transformers

  • Phase Single Phase
  • Warranty 1 Year
  • Coil Number 160 Turns
  • Votage 33 Kv
  • Packaging Bulk
  • Condition New
  • Digital Volt Meter 200 – 750 – 3300 Volts
  • Frequency 50HZ 60HZ
  • Application Measuring instruments

The Resin Cast Cts Are Normally Used For Indoor Application Inside The Panels .the Resign Cast Cts Can Be Used For Outdoor Application Also Provided It Is Enclosed In A Hermetically Sealed Metal Tank

Construction Features :

  • Secondary Terminal
  • Ct Body
  • Mounting Plate
  • Primary Terminal
  • Earthing Terminal

Technical Information For Current Transformers

type: Resin Cast. Outdoor. Oil Minimum          
Nominal System Voltage (kv) LT CT 11 33 66 132
Highest System Voltage (Kv) 0.66 12 36 72.5 145
Power Frequency withstand voltage( 1 min Kv) 3 28 70 140 275
impulse withstand voltage (KvP) NA 75 170 325 650
Rtaed Burden 2.5 VA to 30 Va
Rated frequency (Hz) 50 50 50 50 50
Creepage Distance Phase To Earth (m.m) NA 300 900 1815 3625
Rated Primary Current 2.5 AMP to 2000AMp
Rated Continous Thermal Current (Amp)MAx NA 125 %of Rated Primary Current
Rated Secondary Current 1 Amp 5 AMP/s Per Client Requirment
Rated Short time Thermal Current NA 3KA to 40 KA for one three Second
Rated Dynamic current(KA Peak) NA 2.5 times of short time current
Accuracy class NA 0.2S,0.2,0.5s,0.5,1.0 for metering ,10 PS and PS for protection      
Rated Instrument security Factor 0.5,, 1.0 less than 5 year
Rated Accuracy limit Factor   10,20,30
Knee Point Voltage   As per Customer requirement

 

View Complete Details

Indoor Epoxy Resin Cast Current Transformer

  • Type Current Transformers
  • Certification ISO 9001:2008 Certified
  • Usage Industrial Use
  • Frequency 100-200Hz, 200-400Hz, 50-100Hz
  • Operating Type Automatic
  • Condition New
  • Feature Easy To Install, Proper Working
  • Current Type Single Phase

Epoxy Resin Cast Current Transformer is a dry type transformer in which the internal windings and coils of the transformer are coated with epoxy resin for Insulation purpose. It is widely used in instrument transformers where the primary function is to step down high currents and voltage. In an epoxy resin cast current transformer, the windings consist of high quality electrolytic grade copper which are wound around the core and insulated using a layer of fiberglass mat or quartz powder before being cast with an epoxy resin in an automated vacuum casting machine to provide the necessary insulation.

Epoxy is a strong synthetic thermosetting polymer which is made from various epoxide materials. Epoxy is widely used in various industries like adhesive industry, synthetic paints, casting industry amongst others. In the electrical industry, it is primarily used for the process of insulation. Its chemical composition offers excellent insulation properties and is therefore widely used in the transformer industry for making dry type resin cast transformers.

The function of resin cast current transformers are similar to oil filled current transformers. The reasons why some businesses prefer to use it is because they are better in handling moisture, there is no leakage and pilferage of oil, and they are far more compact in size compared to oil filled transformers

Macroplast manufactures Indoor, Dry Type, Epoxy Resin Cast Current Transformers up to 33 KV system voltage. These are manufactured using high grade epoxy resin polymers and other necessary raw materials. Our resin cast current transformers can be used for both indoor and outdoor usage. For indoor usage, they are placed inside panels or cubicles which are known as indoor metering cubicles. For outdoor usage, they are enclosed in a hermetically sealed metal tank or they may be installed in High Voltage Metering Cubicles. We have 35 years of experience in manufacturing high quality resin cast CTs.

View Complete Details

Current Transformers

  • Frequency 50 Hz ±2%
  • Warranty 1 Year
  • Voltage System 132 Kv
  • Range 230/0-50 (5A) – 200 (5A) -750 (1A) – 3300 (1A) Volts
  • Digital Volt Meter 200 – 750 – 3300 Volts
  • Amp 0 - 0.2 – 2 - 10
  • Meter Accuracy 0.5%
  • Primary Terminal 30mm
  • Mounting Hole 16mm
  • Earthing Paid 50mm X6mm
  • Main Tank 3mmthk

Description :

  • Dead Tank Type Current Transformers Have Cores, Primary And Secondary Windings Arrangend
  • In The Lower Tank. The Primary Windings Are Taken To The Top Tank Through HT Insulators To Be
  • Connected To The Primary Terminals. The Top Tanlk Of These CTs Is Live. The Secondry Winding
  • Are Connected To Secondary Terminals Arranged Inside  The Secondary Terminal Box Placed
  • On The Bottom Tank.


Features:

  • Pressure Release Device
  • Oil Level Indicator(Snow White)
  • Oil Expansion Tank
  • Bushing
  • Bushing Clamp
  • Lifting Lug
  • Name & Rating Plate
  • Oil Drain Plug
  • Secondary Terminal Box
  • Oil Filling Plug
  • Cable Gland

Graph


Download Detail File : Click Here

Technical Information For Current Transformers

3KA to 40 KA for one three Second
type: Resin Cast. Outdoor. Oil Minimum          
Nominal System Voltage (kv) LT CT 11 33 66 132
Highest System Voltage (Kv) 0.66 12 36 72.5 145
Power Frequency withstand voltage( 1 min Kv) 3 28 70 140 275
impulse withstand voltage (KvP) NA 75 170 325 650
Rtaed Burden 2.5 VA to 30 Va
Rated frequency (Hz) 50 50 50 50 50
Creepage Distance Phase To Earth (m.m) NA 300 900 1815 3625
Rated Primary Current 2.5 AMP to 2000AMp
Rated Continous Thermal Current (Amp)MAx NA 125 %of Rated Primary Current
Rated Secondary Current 1 Amp 5 AMP/s Per Client Requirment
Rated Short time Thermal Current NA 3KA to 40 KA for one three Second
Rated Dynamic current(KA Peak) NA 2.5 times of short time current
Accuracy class NA 0.2S,0.2,0.5s,0.5,1.0 for metering ,10 PS and PS for protection      
Rated Instrument security Factor 0.5,, 1.0 less than 5 year
Rated Accuracy limit Factor   10,20,30
Knee Point Voltage   As per Customer requirement
View Complete Details

Live Tank Type Current Transformer

  • Phase Double Phase
  • Warranty 1 Year
  • Voltage System 132Kv
  • Diameter 70mm
  • Height 60mm
  • Cbale Gland 20mm
  • Mounting Hole 16mm

Live Tank type Current Transformers have cores, primary and secondary windings arranged in the top tank. The primary windings are then connected to primary terminals which are also arranged in the top tank. The secondary windings are taken through the HT insulator to the bottom mounting base. The mounting base has arrangement for secondary terminals inside the secondary terminal box.

Construction Features :

  • Pressure Release Diaphram
  • Oil Filling Plug
  • Oil Level Indicator (Back Snow White)
  • Primary Terminal
  • Oil Tank With Cover
  • Name And Rating Plate
  • Bushing Clamp
  • Bushing
  • Secondary Terminals Box
  • Earthing Terminals
  • Lifting Hole
  • Base

Technical Information For Current Transformers

type: Resin Cast. Outdoor. Oil Minimum          
Nominal System Voltage (kv) LT CT 11 33 66 132
Highest System Voltage (Kv) 0.66 12 36 72.5 145
Power Frequency withstand voltage( 1 min Kv) 3 28 70 140 275
impulse withstand voltage (KvP) NA 75 170 325 650
Rtaed Burden 2.5 VA to 30 Va
Rated frequency (Hz) 50 50 50 50 50
Creepage Distance Phase To Earth (m.m) NA 300 900 1815 3625
Rated Primary Current 2.5 AMP to 2000AMp
Rated Continous Thermal Current (Amp)MAx NA 125 %of Rated Primary Current
Rated Secondary Current 1 Amp 5 AMP/s Per Client Requirment
Rated Short time Thermal Current NA 3KA to 40 KA for one three Second
Rated Dynamic current(KA Peak) NA 2.5 times of short time current
Accuracy class NA 0.2S,0.2,0.5s,0.5,1.0 for metering ,10 PS and PS for protection      
Rated Instrument security Factor 0.5,, 1.0 less than 5 year
Rated Accuracy limit Factor   10,20,30
Knee Point Voltage   As per Customer requirement

 

Graph


Download Detail File : Click Here
View Complete Details

Outdoor Oil Minimum Immersed Current Transformer

  • Usage 33Kv Voltage System
  • Primary Stud 20mm
  • Main Tank 3.0mm
  • Angle 50x50mm
  • Condition New
  • High Current Source Upto 10

This Design Has Only One Tank. The Cores And Windings Are Arranged In The Tank And The Primary Windings Are Taken Through Ht Insulators To Be Connected To Primary Terminals. In This Design, Unlike Dead And Live Tank Design, Two Ht Insulators Are Provided For Incoming And Outgoing Conductors. Lt Terminal Box Is Also Provided On The Same Tank

Features :

  • Bushing Cap
  • Bushing (Cji/ge/tayal/re Etc.)
  • Bushing Clamp
  • Earthing Terminals
  • Lifting Lugs
  • Secondary Terminals Box
  • Cable Gland
  • Mounting Hole
  • Oil Level Gauge
  • Gasket
  • Core & Windig

Technical Information For Current Transformers

type: Resin Cast. Outdoor. Oil Minimum          
Nominal System Voltage (kv) LT CT 11 33 66 132
Highest System Voltage (Kv) 0.66 12 36 72.5 145
Power Frequency withstand voltage( 1 min Kv) 3 28 70 140 275
impulse withstand voltage (KvP) NA 75 170 325 650
Rtaed Burden 2.5 VA to 30 Va
Rated frequency (Hz) 50 50 50 50 50
Creepage Distance Phase To Earth (m.m) NA 300 900 1815 3625
Rated Primary Current 2.5 AMP to 2000AMp
Rated Continous Thermal Current (Amp)MAx NA 125 %of Rated Primary Current
Rated Secondary Current 1 Amp 5 AMP/s Per Client Requirment
Rated Short time Thermal Current NA 3KA to 40 KA for one three Second
Rated Dynamic current(KA Peak) NA 2.5 times of short time current
Accuracy class NA 0.2S,0.2,0.5s,0.5,1.0 for metering ,10 PS and PS for protection      
Rated Instrument security Factor 0.5,, 1.0 less than 5 year
Rated Accuracy limit Factor   10,20,30
Knee Point Voltage   As per Customer requirement

 

Graph


Download Detail File : Click Here
View Complete Details

Outdoor Oil Filled Current Transformers

  • Type Oil Filled Transformer
  • Certification CE Certified
  • Application Industrial Use
  • Weight 100-1000kg
  • Color Grey
  • Voltage 440V
  • Automatic Grade Automatic
  • Power 6-9kw, 9-12kw
  • Driven Type Electric
  • Phase Type Single Phase
  • Production Power 250-500kw, 500-750kw, 750-1000kw
We are the main supplier of this product.
View Complete Details

Outdoor Type Potential Transformers Without Top Tank

  • Warranty 1 Year
  • Frequency 50/60Hz
  • Use Industrial
  • Condition New
  • Packaging Packed in good quality boxes
  • Current 500A

Macroplast Manufactures Potential Transformers Without Top Tank (Expansion Chamber) Upto 33kv System Voltage This Design Has A Single Tank. The Core And Windings Are Contained In The Lows Tank. The Prima, Winding Is Taken Through The Ht Insulator To Be Connected T The Prima, Terminal Arranged At The Top Of The Ht Insulator. The Secondary Windings Are Connected To Second, Terminals Placed On The Lower Tank.

  • Primary Terminal
  • Bushing Cap
  • Bushing
  • Bushing Clamp
  • Secondary Terminal Box
  • Main Tank (3.15mm Thk)
  • Base Angle
  • Name & Rating Plate
  • Earthing Terminal
  • Oil Filling Plug
  • Oil Level Indicator
  • Lifting Lug
  • Oil Drain Plug

Macroplast Manufactures Potential Transformers Without Top Tank Graph


Download Detail File : Click Here

Technical Specification For Ptoential Transformer

type: Resin Cast. Outdoor. Oil Cooled          
Nominal System Voltage (kv) 11 33 66 132 220
Highest System Voltage (Kv) 12 36 72.5 145 245
Power Frequency withstand voltage( 1 min Kv) 28 70 140 275 460
impulse withstand voltage (KvP) 75 170 325 650 1050
Rtaed Burden 10 VA TO 500VA
Rated frequency (Hz) 50 50 50 50 50
Creepage Distance Phase To Earth (m.m) 300 900 1815 3625 6125
Rated secondary voltage          
R.ted voltage factor 110 Volt 110√3 Volt
Accuracy class (IS/IEC standard) 1.2 Cont G 1.5 for 30 Second
  0.2,D.5,1.0 For Metetring  3P,5P, 6P For Protection
View Complete Details

Outdoor Type Potential Transformers With Top Tank

  • Warranty 1 Year
  • Voltage Ratio 25 KVA to 5 MVA
  • Number of Phase Three Phase
  • Use Industrial
  • Condition New
  • Packaging Packed in good quality boxes
  • Type Automatic
  • Current 500A
  • Frequency 50/60Hz

Macroplast manufactures Potential transformers with top tank (expansion chamber) upto 132 Kv system voltage. This design has two tanks. The core and windings are contained in the lower tank. The prima, winding is taken through the HT insulator to be connected to the primary terminal arranged on the top tank. The secondary windings are connected to secondary terminals placed on the lower tank. In this design, the .Top Tank provides space for expansion of Oil.

Construction Features :

  • Primary Terminal
  • Oil Level Indicator
  • Pressure Release Device
  • Oil Expansion Tank
  • Bushing
  • Bushing Clamp
  • Secondary Terminal Box
  • Main Tank (3 Mm Thk)
  • Name & Rating Plate
  • Earthing Terminal
  • Lifting Lug

Outdoor Type Potential Transformers (With Top Tank) Graph


Download Detail File : Click Here

Technical Specification For Ptoential Transformer

type: Resin Cast. Outdoor. Oil Cooled          
Nominal System Voltage (kv) 11 33 66 132 220
Highest System Voltage (Kv) 12 36 72.5 145 245
Power Frequency withstand voltage( 1 min Kv) 28 70 140 275 460
impulse withstand voltage (KvP) 75 170 325 650 1050
Rtaed Burden 10 VA TO 500VA
Rated frequency (Hz) 50 50 50 50 50
Creepage Distance Phase To Earth (m.m) 300 900 1815 3625 6125
Rated secondary voltage          
R.ted voltage factor 110 Volt 110√3 Volt
Accuracy class (IS/IEC standard) 1.2 Cont G 1.5 for 30 Second
  0.2,D.5,1.0 For Metering ¢ 3P,5P, 6P For Protection
View Complete Details