Our Products
Storage Drums, Tanks & Containers
2 Products availableRouter, Cables & Networking Devices
1 Products availableElectrical Panels & Distribution Box
1 Products availableControl Panels
1 Products availableResistors
1 Products availableValves & Valve Fittings
1 Products availableDoor Locks
1 Products availableIndustrial & Engineering Products
1 Products availableLeading Manufacturer, Supplier & Retailer of buffer resistance panel.
Buffer Resistance panel will be made-out by 2mm thick CRCA MS sheet steel, free standing, floor mounting, dust & vermin proof construction, indoor type, external & internal surfaces cleaned by chemical treatment, duly painted with approved paint shade. The Buffer Resistance panel having a set of Punched SS grid resistance cont. rated for the RA of the motor with a max. temp rise of 375 to 400oC and having an adequate ohmic value/ phase to run the slip ring motor at 15% slip regulation/regulator.
Grid Rotor Starter Panel (for starting duty) will be made-out/fabricated by 2mm thk. CRCA MS sheet steel, dust & vermin proof construction, front operated, self supported, free standing, floor mounting type, external & internal surfaces cleaned by chemical treatment, duly spray painted with approved paint shade.
Grid Rotor Starter Panel (for starting duty) will be provided ‘Reputed make’ adequate rating & nos. of AC3 duty Air Break Power contactor for Final short-circuiting & Step Contactor for smoothly cutting of resistance and adequate rating & nos. of Timers of ‘Reputed make’ and a set of SS Punched type Grid resistance elements to provide smooth cutting of resistance in required steps in rotor circuit of motor thereby reducing the starting current & increasing the starting torque, for final short-circuiting the resistance when motor attains full speed/to start the motor. It will have Interlocking arrangement/circuit for your/consignee’s Stator control panel, so that, Main motor can not be started unless resistance is in fully ‘IN’ Position. The Grid Rotor Starter Panel (for starting duty) will have all the circuit elements in line to meet Technical requirements to start the motor Locally & Automatically.
A consists number of basic units type DL locks fixed to a steel box. The box houses a mechanism arranged such that certain keys are wrapped when others are removed. Its simplest form a control key is trapped until all other keys have been returned to their respective exchange box locks and turned to their trapped positions. The control key can then be removed, wrapping all other keys. Number of such key-exchange boxes can be kept in sheet steel door enclosure box. The design of this box has been tested at CPRI Bangalore and it ensures IP 55 protection
This interlock consists of two separate parts. One part is the basic interlock fixed on a Brass / Aluminium Body housing the mechanism. Another part is a sliding Bolt. When the sliding bolt is inserted in the main body and key is removed, the sliding bolt will remain trapped in the main body. To release the sliding bolt key should be inserted in the lock. This will release the bolt & trap the key.
This is the basic unit of our interlocking system. These locks consist of a mechanism housed within a brass body. A shaft of round or square cross section is projected from the rear of Lock-body. The lock is operated by inserting and rotating a special key in the lock. Standard Lock with 90°, 65°, or 45°, clockwise or Anticlockwise rotation can be supplied. In these, key is free only in one position. In another position it is trapped in the lock.
The lock of one particular combination can be operated by the key of that combination only. The locks can be provided with spring loaded caps which will prevent ingrees of dust when key is out. Key can also be fitted with rubber caps to prevent entering of dust when key is trapped inside the lock.
This extensive range of Electric Control Panel has been manufactured for Controlling Electric Motors & other Equipments from a Central Location. Our expert team of engineers has designed these devices to handle Switching, Protection, Isolating, Distribution & Control Functions. This range of high-tech Electric Control Panel has been implanted with self aligning power & control terminals. These devices are immensely used in Power Plants, Cement, Paper, Steel, Fertilizer, Petrochemical & other industries.
Features :
Our Power Control Centres & Distribution Boards are appreciated globally for their extreme performance and reliability. Our expertise have designed them with separate compartments for Control, Relay & Metering apparatuses with full width cabling chamber at back and ACBs in fixed or draw-out execution.
Applications :
Features :
For transformers, switch yard and other equipments, self-standing type / equipment mounted / wall mounted types, front or front and front and rear opening. type tested IP-55.
Self standing type, equipment mounted and wired rear opening, type tested up-to IP-55.
Direct on line & star - delta motor starters complete with indication and measuring instruments and protection relays. Totally enclosed in dust and vermin proof sheet steel enclosure suitable for floor or wall mounting.
We manufacture neutral grounding resistor (NGR) as per customer's specifications & requirements . NGRS are used in ac distribution networks to restrict earth fault current to a predetermined level. Resistance grounding of transformer or generator neutral star point is the most effective and preferred method.
It will have two units, free standing, floor mounting type made out of heavy gauge MS Sheet & painted with Primer & 2 coats of anti-corrosive paint.
One Unit :It will have two Compartments i.e. Contactor Panel & Resistance Box. The Contactor Panel will be dust & Vermin proof & will house required Power Contactors to switch ON & OFF the Resistance Banks to attain required speed. The Resistance Box will be well Ventilated type & will house Resistance Banks. The Grid Resistance units will be made of SS Punched plates with high thermal capacity and temperature-rise up to 300°C over an ambient of 50°C. The Resistance unit will be assembled in Banks with good porcelain & other insulated material. The construction & mounting of Resistance Banks will be easy to maintain & replace. The Resistance Box & Contactor Panel will be mounted back to back in one unit. The connection between the Resistance Box and Contactor Panel as well as between Resistance Banks & Power Contactors are done by copper flats of sufficient cross-section. It will be provided suitable rating Air Break Power Contactor (AC 3 duty) of ‘Reputed make’ (in delta connected) to suit the RA of motor. It will be suitable for controlling speed from 60% to 100% as 1.25% speed variation per step in total 32steps.
Second Unit :It will be Control Panel/Speed Selector Panel free standing, Floor mounting, dust & vermin proof. It will house the necessary control units like Aux. Contactors, Timers, Overload Relays, Indicating Lamps, Push Buttons etc. The Mini PLC used for setting of Logic controls of different speeds.
Construction :Sheet Steel Clad, free standing, floor mounting type made out of 2mm. thick sheet with suitable angle iron reinforcement. The paint finish will be Light Grey 631 of IS:5. The Grid Resistance Regulator Panel basically comprises of 2 portions, the Resistor unit and the Contactor Panel. The Resistor unit is attached to the back of Contactor Panel and comprises Grid Elements assembled in the form of banks, stacked one above the other. All the Grids will be housed in this panel. The top will be covered with weld mesh only. Hot Air outlet ducting if required, has to be arranged at top by you. The Power Contactor Panel houses the Rotor Contactors suitably interconnected with adequately rated copper jumpers. A Bus Bar arrangement to connect 4-6Nos. Rotor Cables will be provided at bottom of panel with a suitable clearance from gland plate. The inter connection between Resistor Cubicle and Contactor Cubicle will be done through epoxy insulated wall mounted bushing sealed with gaskets. Proper heat shield arrangement will be made to see that heat transfer does not take place from Resistor Cubicle to Contactor Cubicle. The ‘make’ of Switch gear components will be of reputed make like C&S, L&T, GE, BCH, ABB, Siemens, TC etc.
Cooling Blowers :Cooling Blowers are of either Axial or centrifugal type. The MS Impellers are balanced on a dynamic balancing machine to avoid vibrations. The air output will be as per the requirement of each equipment. While erection, the foundation has to laid separately for blowers and the foundation from blower to panel has to be made through canvas bellows. It is prevent the vibrations of blowers getting transferred to GR Panel.
Tests to be conducted :1. Sequence/Operational-Functional Test as per Schematic/Wiring drawing. 2. Megger Test between Phase to Phase & Phase to Ground by 500 V megger. 3. High Voltage withstand test of 2.5KV for 1 minute on Control Circuit.