1 Products availableWe offer the best product range of High Volume Sampler Model APM 417, Handy Sampler Model APM 831, Stack Sampler Model APM 160, Benzene Sampler and PM 2.5 Sampler Model APM 154.
High Volume Sampler Model APM 417 APM 417 is the basic instruments used to monitor Ambient Air Quality. These are in widespread use all over the world to measure air pollution in industries areas, urban areas, on the shop floor, near monuments and other sensitive areas. In these samplers, air borne suspended particulate matter (SPM) is measured by passing air at high flow rate through a high efficiency filter paper which retains the particles and provision has been made for simultaneous sampling of gaseous pollution also. It is having a continuous duty blower with brushless motor which has replaced the conventional high speed blower where carbon brushes are required to be replaced at regular intervals.
Special Features :
Technical Specification
Flow | 0.8 to 1.5 m3/ min |
Blower | Continuous duty blower with brushes motor |
Recommended Filter | GF/A(8” x 10”) for common use |
Sampling time record | 0 to 99999.99 hrs. time totalizer records the running time in hours |
Automatic Sampling | 24 Hr programmable timer, number of required intervals can be programmed |
Power requirement | 220 volts, Single phase AC |
Weight | 25kg (Weight) |
Warranty | 1 Year |
The increasing impacts of pollutants and hazards to the health and industrial workers has resulted in effect on accurate, reliable and frequent assessment of work space pollution and worker-exposure. The data generation needed for corrective measures to safe the workers as per Factory act 1948 and amendment in 1986-87. Lata Envirotech Handy Sampler Model APM 831 APM 831 used best light weight pump battery operated to suck air through 25 mm dia filter and through suitable absorption solution contained in Impingers (2Nos) fitted. Thus besides particulates any two gaseous pollutants can be monitored simultaneously. Rechargeable battery has been used with sufficient storage of power to operate the sampler for 8 hours. A charger is also provided with APM 831 to recharge the battery. The APM 831 system uses a small battery operated pump to draw air thorough a suitable absorption solution contained in an impinger. If necessary, 2 impingers can be used in series to monitor 2 gaseous pollutants. There is an additional provision to determine suspended particulates in the same exercise by using the open sampling head designed for 25mm diameter filters or membranes. The same hardware can be used to sample a variety of pollutants including oxides of sulphur and nitrogen, halogens, ammonia, sulphides, etc. The particulate sampling head provided with the system is useful for monitoring particulates like silica, cement dust, metal fumes and asbestos fibers in work areas of cement plants, foundries, etc. To ensure complete absorption and reduce loss of absorbing solutions by evaporation, the impinger tubes of the APM 831 are kept in an insulated ice tray.
Special Features :
Technical Specification
Suction Pump | Diaphragm Pump. |
Sampling Rate | 0.5 – 1 LPM |
Power Supply | 230+/-10V AC, 50Hz with Battery charger and Rechargeable Batteries (2AH). |
Operation Time | 8 hours with full charge, with sampling rate of 1 LPM. |
Charge | 15 hours or less. |
Monitoring of stacks and vents are requirement to ensure that emission of air pollutants are within the limit prescribed by regulatory authorities. By regular monitoring of emission one can establish that functioning and performance of installed control system are within the designed limits. Emission data also helps in improving performance of Air Pollution Control System energy saving and helps in optimizing process operation. Lata Envirotech Stack Sampler APM 160 has been developed to fulfill these requirements where user ease and emission monitoring regulations requirement have been given due consideration for reliable data generation. Stack Sampler APM 160 is light weight and portable system fitted with suction pump, with digital pyrometer and digital differential meter. Shifting of instrument from one stack to another stack is very easy. Measurement for differential pressure done by using S-Type Pitot Tube and digital differential meter. High quality leak proof push fitting for Thermocouple and Pitot tube are used. Two dial type vacuum gauges are provided for onsite monitoring of pressure drop in gas stream and particulate stream separately. Thimble holder nozzle and probe pipe has been fitted with Viton O Ring for leak proof connection. Thimble holder can accommodate CFT and GFT and Silica thimble with no extra efforts. Measurement temperature of outgoing gases after cooling can be done with the help of Thermometer which is placed in the impinger tube.
Technical Specification
Stack Gas Temp | Upto 600 degree CA digital pyrometer and 1mtr long thermocouple is provided |
---|---|
Thermocouple | Thermocouple is made up of SS 304 casing, length of insertion 1.0 m with 2 m long cable with suitable connector. |
Manometer | Digital with 0-1300 mm of H20 Column |
Pitot Tube | S-Type pitot tube fabricated from SS 304, 1.0m length extendable to 2m, individual calibrated at reference setup of Lata Envirotech Traceable to NABL accredited laboratories. |
Particulate Sampling | SPM collection in thimble type filter (with pore size of 1.6μm with collection efficiency for 0.3μm particles 99.7% |
Gaseous Sampling | Collection of gases @0.3-3lpm in chemicals kept in a set of 120ml capacity borosilicate glass impingers. |
Rotameter | Plastic body rotameter with 2% FSD accuracy, 0-30lpm for particulate and 0-3 lpm for gases. |
Sampling Probe | Made from SS 304 tube, 1.0m length extendable to 2.0m |
Filter Holder | Fabricated from SS 304 tube suitable to hold either cellulose filtration thimble (size 28 mm ID x 100 mm ling) or glass micro fiber thimbles (size 19mm ID x 90 mm long) |
Nozzles | A set of 3 stainless steel nozzles of different diameter |
Digital Clock | 0-60 minutes, 1 second readout with start stop and reset functions. |
Sampling Train | 1 Nos of 240 ml capacity and 2 Nos. of 120ml capacity borosilicate glass impingers. Accommodated in SS ice tray, placed on the rear side of instrument panel with a provision to keep ice. |
Vacuum pump | Vacuum pump mono block rotary vane type oil filled, 0.5 HP, single phase motor (230 V)with 40 lpm free flow capacity. |
The APM 860 sampler uses an improved cyclone with sharper cutoff (D50 at 10 microns) to separate the coarser particulates from the air stream before filtering it on the glass microfibre filter. By using the APM 860, measurement of Respirable Particulate Matter can be done accurately and TSPM can also be assessed by collection of dust retained in the cyclone cup. Respirable Dust Sampler Model APM 860 Lata Envirotech Model APM 860 is designed and developed for monitoring of PM10 (based on cyclonic flow technique) meets most of the requirement of BIS 5182 (Part 23) 2006. The particulate matter 10 micron and below in size are directly The ambient air is sucked by a blower through corrosion free aluminum modular pipe and pass and it enters thorough a cyclone which divides the particulate matters in two fraction are below 10 micron and another above 10 microns. The Respirable dust (below 10 micron) directly gets deposited on filter paper and the coarser dust (above 10 microns) collected in the cup fitted under the cyclone. A time totalizer records the total running time of the blower. A programmable timer makes the instrument to stop and start as per desired intervals. A stabilizer is provided to provide constant power supply for smooth running of the system. The manometric systems indicate the rate of flow in cubic meter per minute which can be read directly on provided calibrated scale. Collected on filter paper and particulate matters above 10 microns are collected in cyclone cup. This instrument has got the provision for Gaseous Sampling Attachment suitable for sampling 4 gases viz SO2, NO2, O3 and NH3 simultaneously.
Special Features :
APM 860 comes with an in-built voltage stabilizer to compensate for voltage fluctuations. This model has been made more user-friendly, tool box within the instrument, softer handles. Owing to its modular design, APM 860 can be easily paired with a gaseous sampling attachment (for monitoring SO2, NOx, NH3, Ozone etc.) as gaseous sampling requires only a few LPM of air flow. This is possible through an attachable subsidiary unit LES 411. Kindly refer to respective brochures of LES 411.
Technical Specification
Flow Rate | 0.9 – 1.4 m3 /min free flow |
---|---|
Particle Size | Particles of 10 microns & below collected on Filter Paper holder. SPM bigger than 10 microns collected in a separate sampling bottle under the cyclone |
Sampling Time | 28 hours (maximum) |
Sampling Time Record | 0 to 9999.99 hrs. recorded on a Time Totalizer |
Power requirement | Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Size & Weight | 420 x 340 x 790 mm, 40 Kg |
Automatic Sampling | 24 hrs programmable timer to automatically shut off the system after pre-Control set time interval. |
Warranty | One year |
The APM 860 NL sampler uses an improved cyclone with sharper cutoff (D50 at 10 microns) to separate the coarser particulates from the air stream before filtering it on the glass microfibre filter. By using the APM 860 NL, measurement of Respirable Particulate Matter can be done accurately and TSPM can also be assessed by collection of dust retained in the cyclone cup. Respirable Dust Sampler Lata Envirotech Model APM 860 NL is designed and developed for monitoring of PM10 (based on cyclonic flow technique) meets most of the requirement of BIS 5182 (Part 23) 2006. The particulate matter 10 micron and below in size are directly The ambient air is sucked by a blower through corrosion free aluminum modular pipe and pass and it enters thorough a cyclone which divides the particulate matters in two fraction are below 10 micron and another above 10 microns. The Respirable dust (below 10 micron) directly gets deposited on filter paper and the coarser dust (above 10 microns) collected in the cup fitted under the cyclone. A time totalizer records the total running time of the blower. A programmable timer makes the instrument to stop and start as per desired intervals. A stabilizer is provided to provide constant power supply for smooth running of the system. The manometric systems indicate the rate of flow in cubic meter per minute which can be read directly on provided calibrated scale. Collected on filter paper and particulate matters above 10 microns are collected in cyclone cup. This instrument has got the provision for Gaseous Sampling Attachment suitable for sampling 4 gases viz SO2, NO2, O3 and NH3 simultaneously.
Special Features :
Additional advantage with this blower is very low variation in flow rate in 230V input power supply range : Owing to its modular design, APM 860 NL can be easily paired with a gaseous sampling attachment (for monitoring SO2, NOx, NH3, Ozone etc.) as gaseous sampling requires only a few LPM of air flow. This is possible through an attachable subsidiary unit LES 411. Kindly refer to respective brochures of LES 411.
Technical Specification
Flow Rate | 0.9 – 1.4 m3 /min free flow |
---|---|
Particle Size | Particles of 10 microns & below collected on Filter Paper holder. SPM bigger than 10 microns collected in a separate sampling bottle under the cyclone |
Sampling Time | 28 hours (maximum) |
Sampling Time Record | 0 to 9999.99 hrs. recorded on a Time Totalizer |
Power requirement | Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Size & Weight | 420 x 340 x 790 mm, 45 Kg |
Automatic Sampling | 24 hrs programmable timer to automatically shut off the system after pre-Control set time interval. |
Warranty | One year |
The APM 154 system is a manual method for sampling fine particles (PM2.5 fraction) and is based on impactor designs standardized by US-EPA for ambient air quality monitoring. Ambient air enters the APM 154 series samplers system through an omni-directional inlet designed to provide a clean aerodynamic cut-point for particles greater than 10 microns. Particles in the air stream finer than 10 microns proceed to a second impactor that has an aerodynamic cut-point at 2.5 microns. The air sample and fine particulates exiting from the PM 2.5 impactor are passed through a 47 mm diameter Teflon filter membrane that retains the fine particulate matter. The sampling rate of the system is held constant at 1m3/hr by a suitable critical orifice. The standard system is supplied with a Dry Gas Meter to provide a direct measure of the total air volume sampled. As per recent Air quality standard published by Govt. of India where measurement of PM 2.5 dusts has been made mandatory besides other parameters for defining the quality of ambient air. An Impactor based PM10/2.5 Sampler has been manufactured by Lata Envirotech Services which meet requirements of PM 2.5 is sampling using APM 154; PM 2.5 concentration in ambient air can be measured gravimetrically by using this sampler. APM 154 fitted with brushless and noiseless pump assembly where sampling rates of 1m3/hr is maintained constant with the help of orifice.
Special Features :
Technical Specification
Size Selective inlets | Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor |
Flow Rate | Constant sampling rate of 1 m3/hr unaffected by voltage fluctuation and filter choking maintained by critical orifice system |
Sampling Time Record | 0 to 9999.99 hrs. recorded on a Time Totalizer |
Vacuum Pump | Diaphragm Pump |
Power requirement | Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Automatic Sampling | 24 hrs programmable timer to automatically shut off the system after pre-Control set time interval. |
Sample Volume | Dry Gas meter records the total air volume sampled |
Filter | Filter holder designed to accept any standard 47 mm diameter filter media |
Warranty | One year |
Digital Velosity Monitor Model APM 101 Model APM-101 is designed to determine velocity of air/flue gas in duct /pipe/chimney. Where determination of the rate of flow inside a chimney is of interest. This instrument can be conveniently used to measure the total quantity/volume of emissions. Lata Envirotech Digital Velosity Monitor Model APM 101 APM–101 is designed to determine velocity of air/flue gas in duct / pipe/chimney. In situations where determination of the rate of flow inside a chimney is of interest, this instrument can be used very conveniently to measure the total quantity/volume of emissions.
Special Features :
Technical Specification
Stack Temperature Range | Ambient to 600 C read on a Digital Pyrometer. |
---|---|
Stack Velocity Range | 2 to 100m/sec |
Thermocouple | Thermocouple sensor in SS 304 casing, length of insertion: 0. 6m with 2m long cable |
Manometer | Digital with 0-1300mm of H2O ranges with 0.1 mm least count |
Pitot Tube | Modified Calibrated S-type pitot tube fabricated from SS 304, 0.6m length with extension of 0. 6m. |
Ambient air enters the APM 154 MFC Sampler through an omni directional inlet designed to provide a clear aerodynamic cut-point for particles larger than 10 microns. The air stream then passes through a WINS Impactor that retains the fraction between PM 10 and PM 2.5. The PM 10 and PM 2.5 impactors used in the APM 154 MFC are based on designs standardized by US-EPA and as such the system complies with international norms for PM 2.5 Samplers.
Special Features :
Technical Specification
Size Selective inlets: | Omni directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor |
Flow Rate: | 1 m3/hr controlled by mass flow controller |
Vacuum Pump: | Oil Free, nonpul`sating pump driven by induction motor for stable flow rate |
Power requirement | Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Filter Media | Filter holder designed to accept any standard 47 mm diameter filter media |
Sample Volume | Data Logger |
Elapsed time indicator | Real Time clock records the operating time for each sample |
Flow recorder | Digital Microcontroller based system records flow rate, volume of air sampled, air temperature and filter temperature in nonvolatile flash memory |
Warranty | One year |