1 Products availableWe offer the best product range of Digital Velosity Monitor Model APM 101, PM 2.5 Sampler APM 154 MFC and Digital Air Velocity Monitor.
Digital Velosity Monitor Model APM 101 Model APM-101 is designed to determine velocity of air/flue gas in duct /pipe/chimney. Where determination of the rate of flow inside a chimney is of interest. This instrument can be conveniently used to measure the total quantity/volume of emissions. Lata Envirotech Digital Velosity Monitor Model APM 101 APM–101 is designed to determine velocity of air/flue gas in duct / pipe/chimney. In situations where determination of the rate of flow inside a chimney is of interest, this instrument can be used very conveniently to measure the total quantity/volume of emissions.
Special Features :
Technical Specification
Stack Temperature Range | Ambient to 600 C read on a Digital Pyrometer. |
---|---|
Stack Velocity Range | 2 to 100m/sec |
Thermocouple | Thermocouple sensor in SS 304 casing, length of insertion: 0. 6m with 2m long cable |
Manometer | Digital with 0-1300mm of H2O ranges with 0.1 mm least count |
Pitot Tube | Modified Calibrated S-type pitot tube fabricated from SS 304, 0.6m length with extension of 0. 6m. |
Ambient air enters the APM 154 MFC Sampler through an omni directional inlet designed to provide a clear aerodynamic cut-point for particles larger than 10 microns. The air stream then passes through a WINS Impactor that retains the fraction between PM 10 and PM 2.5. The PM 10 and PM 2.5 impactors used in the APM 154 MFC are based on designs standardized by US-EPA and as such the system complies with international norms for PM 2.5 Samplers.
Special Features :
Technical Specification
Size Selective inlets: | Omni directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor |
Flow Rate: | 1 m3/hr controlled by mass flow controller |
Vacuum Pump: | Oil Free, nonpul`sating pump driven by induction motor for stable flow rate |
Power requirement | Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Filter Media | Filter holder designed to accept any standard 47 mm diameter filter media |
Sample Volume | Data Logger |
Elapsed time indicator | Real Time clock records the operating time for each sample |
Flow recorder | Digital Microcontroller based system records flow rate, volume of air sampled, air temperature and filter temperature in nonvolatile flash memory |
Warranty | One year |