Our Products
Living Room And Plastic Furniture
2 Products availableChemical Machinery & Plant
1 Products availableLaboratory Shakers
1 Products availableAutoclaves
1 Products availableLab Incubator
1 Products availableClean Room Equipment
1 Products availableSterilizers
1 Products availableOur Complete range of products are Refrigerated Research Centrifuge, Vertical Laminar Air Flow Cabinet, Refrigerated Microspin Centrifuge, Bod Incubator and Cryoprecipitate Bath.
KRC-20D Features
Safety
KRC-20B Features
KRC-20B Safety
KRC-20B Technical Data
Fixed Angle Rotor Head
Model | Cap./ml | Type of Rotor | ( RC 41000F )Max. RPM | ( MP 400R )Max RCF xg |
---|---|---|---|---|
TC 4101 | 4x100 | Angle | 14000 | 22110 |
TC 4102 | 8x50 | Angle | 13500 | 22100 |
TC 4103 | 6x50 | Angle | 14500 | 23000 |
TC 4104 | 4x50 | Angle | 17000 | 28600 |
TC 4105 | 8x25 | Angle | 15000 | 24000 |
TC 4106 | 6x25 | Angle | 17000 | 28700 |
TC 4107 | 12x15 | Angle | 15000 | 23670 |
TC 4108 | 8x15 | Angle | 16500 | 27200 |
TC 4109 | 6x15 | Angle | 20000 | 37000 |
TC 4110 | 4x10 | Swing Out | 12500 | 16100 |
TC 4111 | 24x1.5/2 | Angle | 20000 | 30500 |
TC 4113 | 24x0.5 | Angle | 20000 | 29000 |
TC 4114 | 4x25 | Swing Out | 12000 | 16000 |
TC 4115 | 18x15 | Angle | 12000 | 17600 |
TC 4116 | 192x0.5 | Angle | 14000 | 24600 |
TC 4117 | 48x1.5/2 | Angle | 15000 | 22100 |
TC 4118 | 48x1.5/2(Vacutainer tubes) | Angle | 10000 | 10400 |
TC 4120 | 6 Strip of 8 x 0.2ml | Angle | 11000 | 12180 |
Why Laminar Flow Cabinets?
Working & Features of Vertical Laminar Air Flow Unit
Krew Instruments Pvt Ltd's Vertical Laminar Air Flow units also provide a product protection from within the work area, which is exclusively confined by a clear glass panel and sliding glass doors. The salient features include :
KRC - 16K Features
Safety
KRC - 16KR Features
KRC - 16KR Technical Data
Fixed Angle Rotor Head
Model | Cap./ml | Type | Type of Tube | RPM | RCF |
---|---|---|---|---|---|
TC 481 | 24x1,5/2 | Angle | Eppendorff | 14000 | 18360 |
TC 482 | 24xPCR | Angle | Eppendorff | 14000 | 13320 |
TC 483 | 30x0.4 | Angle | Eppendorff | 13500 | 15560 |
TC 484 | 16x1 | Angle | Eppendorff | 13500 | 14790 |
TC 485 | 8x3 | Angle | Eppendorff | 13500 | 15810 |
TC 486 | 6x5 | Angle | P.P.(T.B.) | 13500 | 14790 |
TC 491 | 10X1 | Angle | Glass (R.B.) | 16000 | 17500 |
TC 492 | 12X0.5 | Angle | Glass (R.B.) | 16000 | 17500 |
TC 495 | Micro Haematocrite Capillary | 12300 | 16270 | ||
TC 495R | Reading Device | N.A | N.A | ||
TC 496 | Micro Haematocrite Capillary (12x QBC - II Plus Carrier) | 12300 | 16270 | ||
TC 497 | 4 Strip of 8 x 0.2ml | Angle | PCR Strip Tubes | 12000 | 11910 |
Salient Features
Construction
Bacteriological Incubators by Krew Instruments Pvt Ltdare available with double walled construction which is fully insulated with polyurethane foam for cost-effective operation, offer a number of shelves within the unit for increased storage facility.
CoolingImproved cooling system is an advantageous feature in the designs of Krew Instruments Pvt Ltd BOD incubators.
DoorsThe doors belonging to the BOD incubators are available in stainless steel or glass. You can request for the type of door in case of a custom BOD design.
SafetyFor optimum safety of preservation and storage, the units are well equipped with many precautionary safety measures to ensure no leakage or any temperature variation and loss of control.
Temperature Range
Cabinet Construction and Refrigeration System
Special Features
The digital microprocessor control offers a very rapid temperature and a quick recovery with an optimal temperature stability to assist and reduce the time that required thawing such multiple bags. They are user-friendly so it allows multiple time options to thaw any sized bags
Cryoprecipitate baths are safely thawed for multiple blood products that may be required for a patient infusion. Quick and easy to drain, these machines provide the accurate conditions that are needed to perform the best recovery. After the uniform temperature and all flow is set, the cryoprecipitate bath has a built-in alarm which will alert any personnel if the limits are well exceeded for an optimal operation security. Since the fresh frozen plasma is negatively impacted by any contaminated baths, Krew Instruments Pvt Ltd equipment can be exceptionally very easy to clean between uses.
CalibrationThe Equipment Calibrated With the Help of Master Calibrator, Which is Certified for its Accuracy by Electronics Regional Test Laboratory (ERTL-Mumbai)
Technical Specification
Model No. | KTB / KCB -8 | KTB / KCB-15 |
---|---|---|
Capacity | 8 bags | 15 bags |
Volume | 10 liters | 20 liters |
Temperature | 37 °C / 4 oC | 37 °C / 4oC |
Accuracy | ± 0.2 °C | ± 0.2 °C |
Power Supply | 230 VAC 50Hz | 230 VAC 50Hz |
Thawing Liquid | DM Water | DM Water |
Timer | 99 minutes | 99 minutes |
External Dimension (Apx.) | 300 X 445 X 355 | 650 X 450 X 325 |
Special Features
The Platelet Agitator features the uniquely designed rack with high ventilation capability to allow oxygen flow to the platelets. Smooth sliding stainless steel trays are provided which can be removed for cleaning as well as forplacing of the bags. Fixed speed agitation with heavy duty bearings and quiet operation also marked as special aspects in the design. The agitation stops automatically when the door is opened.
CalibrationCalibration in this equipment is done with the help of a master calibrator, which is certified for its accuracy by the electronic Regional Testing Laboratory (ERTL), which is recognized by the Government of India.
Technical Data
Model No. | KPI - 125 | KPI - 250 |
---|---|---|
Volume | 125 Ltr. | 250 Ltr. |
Temperature | 22 °C | 22 °C |
Temperature Controller | LCD Graphic Display | LCD Graphic Display |
Temperature Recorder | 7 days Circular Chart | 7 days Circular Chart |
Accommodating Capacity | One Agitator 36/48 | Two Agitator 36/48 |
Accuracy | ±0.5°C | ±0.5°C |
Power Supply | 230 VAC 50Hz | 230 VAC 50Hz |
KRC - 18K
Safety :
KRC - 10K
Safety
KRC - 10MP
Safety :
Technical Data :
Tc 8101 Swing Out Rotor Head Without Buckets
Buckets (Carriers) Suitable For Use With Tc 8101 Swing Out Rotor Head.
Model | Cap./ml | Max.RPM | Max.RCF xg |
---|---|---|---|
TC 8101 A | 4x200 | 5200 | 5050 |
TC 8101 B | 4x100 | 6100 | 6600 |
TC 8101 C | 4x18 RIA(5ml) | 5200 | 4200 |
TC 8101 V | 4x9 Vacutainer (2,3,4 &5 ml) | 5200 | 4200 |
TC 8101 VL | 4x9 Vacutainer (6 ml) | 5200 | 4200 |
TC 8101 J | 4(4x15) | 4500 | 2780 |
TC 8101 G | 4(3x15) | 4500 | 2780 |
TC 8101 D+E | 4x27 RIA(5ml) | 5200 | 4200 |
TC 8101 I | 4(15x6) | 5200 | 5050 |
TC 8107 | 2x1 MTP (Micro Titer Plate) | 3400 | 1700 |
TC 8108 | 2x2 MTP (Micro Titer Plates) | 3400 | 1700 |
TC 8109 | 4x250 | 5200 | 5050 |
Fixed Angle Rotor Head
TC | 8100D | TC | 8100 F | MP | 800 | ||
---|---|---|---|---|---|---|---|
Model | Cap./ml | RPM | RCF | RPM | RCF xg | RPM | RCF xg |
TC 8102 | 12X25 | 7000 | 7100 | 7000 | 7100 | 7000 | 7100 |
TC 8103 | 6X200 | 7000 | 7250 | 7000 | 7250 | 7000 | 7250 |
TC 81 04 | 8X100 | 7000 | 7100 | 7000 | 7100 | 7000 | 7100 |
TC 8105 | 12X50 | 7000 | 7100 | 7000 | 7100 | 7000 | 7100 |
TC 8106 | 36X15 | 7000 | 7100 | 7000 | 7100 | 7000 | 7100 |
TC 4115 | 18X15 | - | - | 10000 | 10500 | 10000 | 10500 |
TC 4111 | 24X1.5/2 | - | - | 10000 | 10500 | 10000 | 10500 |
TC 8101 J | 4(4X15) | 4500 | 2780 | 4500 | 2780 | 4500 | 2780 |
TC 8101 G | 4(3X15) | 4500 | 2780 | 4500 | 2780 | 4500 | 2780 |
TC 8101 I | 4(15X6) | 5200 | 5050 | 5200 | 5050 | 5200 | 5050 |
TC 8110 | 4X250 | 7000 | 7250 | 7000 | 7250 | 7000 | 7250 |
Reduction Adapter For Use With Swing Out Rotor Carriers.
TC 8111 | 100 ml in 200 ml carrier | TC 8118 | 4x15 ml in 100 ml carrier |
---|---|---|---|
TC 8112 | 50 ml in 200 ml carrier | TC 8116 | 25 ml in 100 ml carrier |
TC 8114 | 7x15 ml in 200 ml carrier | TC 8121 | 1X50 ml in 250 ml carrier |
TC 8113 | 3x30 ml in 200 ml carrier | TC 8122 | 3X25 ml in 250 ml carrier |
TC 8117 | 13x15 ml in 200 ml carrier | TC 8123 | 5X15 ml in 250 ml carrier |
TC 8115 | 50 ml in 200 ml carrier | TC 8124 | 13X5 ml in 250 ml carrier |
Multispin Centrifuge KLC - 6D Features
Multispin Centrifuge KLC - 6B Features
SafetyImbalance detection & safety switch offSafety Lid switch
Technical Data
Multispin Centrifuge (Choic Of Rotor Heads For)
Model | Cap./ml | Type | RPM | RCF xg |
---|---|---|---|---|
TC 652 | 16x15 | S/O | 4200 | 2900 |
TC 653 | 12x15 | S/O | 4200 | 2900 |
TC 654 | 8x15 | S/O | 4300 | 3250 |
TC 655 | 6x50 | S/O | 4350 | 2950 |
TC 656 | 4x50 | S/O | 4200 | 3050 |
TC 657 | 16x15 | Angle | 5200 | 3900 |
TC 658 | 12x15 | Angle | 5500 | 3950 |
TC 659 | 8x15 | Angle | 5500 | 3950 |
TC 660 | 6x50 | Angle | 5100 | 3750 |
TC 661 | 4x50 | Angle | 5500 | 3950 |
TC 662 | 24x15 | Angle | 5000 | 3400 |
Choic Of Rotor Heads For
Model | Cap./ml | Type | RPM | RCF xg |
---|---|---|---|---|
TC 652 | 16x15 | S/O | 4500 | 3330 |
TC 653 | 12x15 | S/O | 4500 | 3330 |
TC 654 | 8x15 | S/O | 4500 | 3560 |
TC 655 | 6x50 | S/O | 4500 | 3155 |
TC 656 | 4x50 | S/O | 4500 | 3500 |
TC 657 | 16x15 | Angle | 6000 | 5190 |
TC 658 | 12x15 | Angle | 6250 | 5095 |
TC 659 | 8x15 | Angle | 6250 | 5095 |
TC 660 | 6x50 | Angle | 6000 | 5190 |
TC 661 | 4x50 | Angle | 6250 | 5095 |
TC 662 | 24x15 | Angle | 6000 | 4895 |
TC 664 | 24x15 | Angle | 6000 | 5030 |
KLS-10D Features
KLS-10B Features
SafetyImbalance detection & safety switch off.Safety Lid switch.
Technical Data
KMS-16D Features
KMS-16B Features
Safety
KMS-16BF
SafetyImbalance detection & safety switch off.Safety Lid switch
Technical Data
Choice Of Rotor Heads
Model | Cap./ml | Type | Type of Tube | RPM | RCF |
---|---|---|---|---|---|
TC 481 | 24x1,5/2 | Angle | Eppendorff | 14000 | 18360 |
TC 482 | 24xPCR | Angle | Eppendorff | 14000 | 13320 |
TC 483 | 30x0.4 | Angle | Eppendorff | 13500 | 15560 |
TC 484 | 16x1 | Angle | Eppendorff | 13500 | 14790 |
TC 485 | 8x3 | Angle | Eppendorff | 13500 | 15810 |
TC 486 | 6x5 | Angle | P.P.(T.B.) | 13500 | 14790 |
TC 491 | 10X1 | Angle | Glass (R.B.) | 16000 | 17500 |
TC 492 | 12X0.5 | Angle | Glass (R.B.) | 16000 | 17500 |
TC 495 | Micro Haematocrite Capillary | 12300 | 16270 | ||
TC 495R | Reading Device | N.A | N.A | ||
TC 496 | Micro Haematocrite Capillary (12x QBC - II Plus Carrier) | 12300 | 16270 | ||
TC 497 | 4 Strip of 8 x 0.2ml | Angle | PCR Strip Tubes | 12000 | 11910 |
Blood Bank Centrifuge Technical Data
KBC Features
Core Features
Other Features, Displays & Safety Systems
Dimension (W x D x H) mm: 860 x 960 x 965.
Technical Data
Model | Cap. / ml | RPM | RCF xg |
---|---|---|---|
KBC-12 | 12 Blood Bags of 450 ml (Triple Bag System) | 4500 | 6000 |
KBC-6 | 6 Blood Bags of 450 ml (Triple Bag System) | 4500 | 6000 |
KBC-8 | 8 Blood Bags of 450 ml (Triple Bag System) | 4800 | 5650 |
KBC-4 | 4 Blood Bags of 450 ml (Triple Bag System) | 4800 | 5650 |
KHS-20D Features
KHS-20B Features
SafetyImbalance detection & safety switch off.Safety Lid switch.
Technical Data
Fixed Angle Rotor Head
Model | Cap ./ml | Type of Rotor | Max. RPM | Max. RCF xg | Max. RPM | Max. RCF xg |
---|---|---|---|---|---|---|
TC 4101 | 4x100 | Angle | 14000 | 22110 | 13600 | 20800 |
TC 4102 | 8x50 | Angle | 13500 | 22100 | 13000 | 20480 |
TC 4103 | 6x50 | Angle | 14500 | 23000 | 14200 | 22070 |
TC 4104 | 4x50 | Angle | 17000 | 28600 | 15500 | 23800 |
TC 4105 | 8x25 | Angle | 15000 | 24000 | 14500 | 22400 |
TC 4106 | 6x25 | Angle | 17000 | 28700 | 16700 | 27700 |
TC 4107 | 12x15 | Angle | 15000 | 23670 | 14500 | 22100 |
TC 4108 | 8x15 | Angle | 16500 | 27200 | 15700 | 24600 |
TC 4109 | 6x15 | Angle | 20000 | 37000 | 17500 | 28400 |
TC 4110 | 4x10 | Swing Out | 12500 | 16100 | 12000 | 14800 |
TC 4111 | 24x1.5/2 | Angle | 20000 | 30500 | 18500 | 26100 |
TC 4113 | 24x0.5 | Angle | 20000 | 29000 | 18500 | 24800 |
TC 4114 | 4x25 | Swing Out | 12000 | 16000 | 11500 | 14700 |
TC 4115 | 18x15 | Angle | 12000 | 17600 | 11700 | 16700 |
TC 4116 | 192x0.5 | Angle | 14000 | 24600 | 13500 | 22900 |
TC 4117 | 48x1.5/2 | Angle | 15000 | 22100 | 14600 | 20900 |
TC 4118 | 24 X3/4 (Vacutainer tubes) | Angle | 10000 | 10400 | 10000 | 10400 |
TC 4120 | 6 Strip of 8 X 0.2ml | Angle | 11000 | 12180 | -- | -- |