Our Products
Electrical Box
2 Products availableMobile Phone Cable
2 Products availableElectronic Cables
2 Products availableElectrical Conductor
2 Products availablePower Cables
2 Products availableWe are leaders in the market for providing best range of Fiber Glass Epr Cables, Aerial Bunched Cables, Copper Single Multicore Flexible Cables, Fire Resistant Cables and Halogen Free Control Cables
We have pioneered in supplying Aerial Bunched Cables. The Aerial Bunched Cables that we offer are widely used for power distribution in rural and congested areas with narrow lanes and by-lanes. These Aerial Bunched Cables are specially designed conforming to IS: 14255 quality standards, in order to ensure high performance. Our Aerial Bunched Cables are highly demanded by the clients, owing to their striking attributes such as higher level of safety and reliability.
Applications :
Benefits :
LT Aerial Bunched Cabels as per IS: 14255-1995
Phase Conductor Aluminum | Street Lighting Conductor Aluminium | Messenger Conductor Aluminium Alloy | ||||||
Nom. Area | Max. D.C Conductor Resistance At 20 Deg. C | Nom. Thickness Of Insulation XLPE/PF | Nom. Area | Max. D.C Conductor Resistance At 20 Deg. C | Nom. Thickness Of Insulation XLPE/PE | Nom. Area | Max. D.C Conductor Resistance At 20 Deg. C | Min. Breaking Load |
Sqmm | Ohm/Km | mm | Sqmm | Ohm/Km | mm | Sqmm | Ohm/Km | KN |
16 | 1.91 | 1.2 | 16 | 1.91 | 1.2 | 25 | 1.38 | 7 |
25 | 1.2 | 1.2 | 16 | 1.91 | 1.2 | 25 | 1.38 | 7 |
35 | 0.868 | 1.2 | 16 | 1.91 | 1.2 | 25 | 1.38 | 7 |
50 | 0.641 | 1.5 | 16 | 1.91 | 1.2 | 35 | 0.986 | 9.8 |
70 | 0.443 | 1.5 | 16 | 1.91 | 1.2 | 50 | 0.689 | 14 |
95 | 0.32 | 1.5 | 16 | 1.91 | 1.2 | 70 | 0.492 | 19.7 |
Composition and Designation of Lt Aerial Bunched Cables as per Red Specification No. 32
Designation | Complete Bunched Cables | |
Approx. Overall Dia. | Approx. Total Mass | |
 | mm | Kg/Km |
3X16+25 | 19 | 250 |
3X16+16+25 | 19 | 310 |
3X25+25 | 22 | 330 |
3X25+16+25 | 22 | 390 |
3X35+25 | 24 | 430 |
3X35+16+25 | 24 | 490 |
3X50+35 | 32 | 580 |
3X50+16+35 | 32 | 640 |
LT Aerial Bundled Conductor (abc) Polymeric Insulated as per Bs: 7870 (part-5) 1999
Nominal Cross Sectional Area of Conductor | Max. D.C Resistance At 20 Deg. C Of XLPE | Mix Average Thickness Conductor | Ultimate Tensile Strength of Insulation |
25 | 1.200 | 1.3 | 4.1 |
35 | 0.868 | 1.3 | 5.6 |
50 | 0.641 | 1.5 | 7.6 |
70 | 0.443 | 1.5 | 11.0 |
95 | 0.320 | 1.7 | 15.3 |
120 | 0.253 | 1.7 | 19.4 |
Characteristics of Conductors and Cores for Lt Aerial Bunched Cables Asper Nfc 33-2099
Designation | Conductor | Average Thickness of Insulating Sheath Specified Min. | Core | ||||||
Type | Nominal Sectional Area | No. of Strands | Max. Linear Resistance At 20 Deg. C | Min. Conductor Dia. Min. | Breaking Strength Max. | Breaking Strength Max. | Max. | ||
Sqmm | Ohm/Km | mm | daN | daN | mm | mm | mm | ||
PHASE OR NEUTRAL NON RETURN | 16 | 7 | 1.91 | 4.7 | 190 | 290 | 1.2 | 7 | 7.9 |
25 | 7 | 12 | 6 | 300 | 450 | 14 | 8.7 | 9.6 | |
35 | 7 | 0.641 | 8.2 | 600 | 900 | 1.6 | 11.3 | 12.3 | |
50 | 7 | 0.641 | 8.2 | 600 | 900 | 1.6 | 11.3 | 12.3 | |
70 | 12 | 0.443 | 9.8 | 840 | 1260 | 1.8 | 13.3 | 14.3 | |
NEUTRAL RETURN | 54.6 | 7 | 0.63 | 9.2 | 1660 | - | 1.6 | 12.3 | 13 |
Composition and Designatin of Ht Aerial Bunched Cable as per Rec Specification No. 64
Designation | Complete Bunched Cables | |
Approx. Overall Dia. | Approx. Total Mass | |
Mm | Kg/Km | |
6.35/11 KV 3X35+70 | 53 | 1450 |
6.35/11 KV 3X70+70 | 59 | 1900 |
Click Here For Technical Specifications Click Here For More Details
We bring forth Copper Single Multicore Flexible Cables, to the clients all over the world. The Copper Single Multicore Flexible Cables provided by us bear the mark of IS: 694: 1990. Our Copper Single Multicore Flexible Cables are made from 99.97% pure, electrolytic grade, bright-annealed bare Copper, for excellent conductivity and longer functional life. These Copper Single Multicore Flexible Cables are ideal for conduit wiring, in various sectors.
Attributes :
Specifications
Area Sp. Mm | Conductor Construction No./Dia In m.m. | Cond.Dia mm | Max. DC Resistance Ohm/Km At 20 0 C | Insulation Thickness (Nominal) m.m. | Cable Dia m.m | Current Rating Amp. | Area Sp. m.m. | Con. Dia m.m. | Max. DC Resistance Ohm/Km At 20 0 C | Insulation Thickness (Nominal) m.m. | Cable Dia. m.m. | Cable Dia m.m. | Approx. Current Rating Amp. |
0.5 | 16/0.20 | 0.94 | 39 | 0.6 | 2.2 | 4 | 25 | 157/.045 | 7.6 | 0.78 | 1.2 | 10.5 | 71 |
0.75 | 24/0.20 | 1.2 | 26 | 0.6 | 2.5 | 7 | 35 | 220/0.45 | 8.7 | 0.55 | 1.2 | 11.6 | 91 |
1 | 32/0.20 | 1.34 | 19.5 | 0.6 | 2.6 | 11 | 50 | 314/0.45 | 10.6 | 0.39 | 1.4 | 13.9 | 120 |
1.5 | 48/0.20 | 1.64 | 13.3 | 0.6 | 2.8 | 14 | - | - | - | - | - | - | - |
2.5 | 80/0.20 | 2.08 | 7.98 | 0.7 | 3.5 | 19 | - | - | - | - | - | - | - |
4 | 56/.030 | 2.61 | 4.95 | 0.8 | 4.3 | 26 | - | - | - | - | - | - | - |
6 | 85/030 | 3.5 | 3.3 | 0.8 | 5.6 | 31 | - | - | - | - | - | - | - |
10 | 03/30/40 | 4.6 | 1.91 | 1 | 6.7 | 42 | - | - | - | - | - | - | - |
16 | 101/0.45 | 5.9 | 1.21 | 1 | 8.4 | 57 | - | - | - | - | - | - | - |
Nominal Cross Sectional Area of Conductor in Mm 2 | Nominal Insulation Thickness in M.m. | Max. Over all Diameter of Cable in M.m. |
1 | 0.7 | 3.2 |
1.5 | 0.7 | 3.4 |
2.5 | 0.8 | 4.2 |
4 | 0.8 | 4.8 |
6 | 0.8 | 5.6 |
10 | 1 | 7 |
16 | 1 | 8.2 |
25 | 1.2 | 10 |
35 | 1.2 | 11.5 |
50 | 1.4 | 13 |
70 | 1.4 | 15 |
95 | 1.6 | 17.5 |
120 | 1.6 | 19 |
150 | 1.8 | 21 |
185 | 2 | 23.5 |
240 | 2.2 | 26.5 |
300 | 2.4 | 29.5 |
Conductor Area Sq. m.m | Strands/Dia In m.m. | Cond. Dia m.m. | Max. DC Resistance Ohm/Km At 20 0 C | Insulation Thickness (Nominal) m.m. | Core Dia m.m. | Sheath Thickness In m.m. (Nominal) 2 Core 3 Core 4 Core | Overall Diameter In m.m. (Approx.) 2 Core 3 Core 4 Core | Approx. Current Rating Amp. | ||||
0.5 | 16/0.20 | 0.94 | 39 | 0.6 | 2.2 | 2.2 | 0.9 | 0.9 | 6.4 | 6.8 | 7.5 | 4 |
0.75 | 24/0.20 | 1.2 | 26 | 0.6 | 2.5 | 2.5 | 0.9 | 0.9 | 7 | 7.4 | 8.1 | 7 |
1 | 32/0.20 | 1.34 | 19.5 | 0.6 | 2.6 | 2.6 | 0.9 | 0.9 | 7.2 | 7.7 | 8.3 | 11 |
1.5 | 48/0.20 | 1.64 | 13.3 | 0.6 | 2.9 | 2.9 | 0.9 | 1 | 7.8 | 8.3 | 9.2 | 14 |
2.5 | 80/0.20 | 2.08 | 7.91 | 0.7 | 3.5 | 3.5 | 1 | 1 | 9.2 | 9.8 | 10.7 | 19 |
4 | 56/.03 | 2.61 | 4.95 | 0.8 | 4.3 | 4.3 | 1 | 1 | 10.8 | 11.5 | 12.6 | 26 |
No. OF WIRE WIRE DIA. m.m. | BUNCH DIA. m.m | Max. CR at 20 0 C Ohm/km | Nominal Insulation THICKNESS m.m. | Approx CORE DIA.m.m. | 6 CORE | 7 CORE | 8 CORE | 10 CORE | 12 CORE | APPROX CURRENT RATING AMP. | |||||
Sheath Thick m.m. | O.D m.m. | Sheath Thick m.m. | ODm.m. | Sheath Thick m.m. | O.D.m.m. | Sheath Thick m.m. | O.D.m.m | Sheath Thick m.m. | O.D.m.m | ||||||
16/0.2 | 0.94 | 39 | 0.6 | 2.2 | 0.9 | 8.5 | 0.9 | 8.5 | 1 | 9.3 | 1 | 10.8 | 1 | 11.2 | 4 |
24/0.2 | 1.2 | 26 | 0.6 | 2.5 | 1 | 9.5 | 1 | 9.5 | 1 | 10.4 | 1.1 | 12.2 | 1.1 | 12.6 | 7 |
32/0.2 | 1.34 | 19.5 | 0.6 | 2.6 | 1 | 9.8 | 1 | 9.8 | 1 | 10.7 | 1.1 | 12.6 | 1.1 | 13 | 11 |
48/0.2 | 1.64 | 13.3 | 0.6 | 2.9 | 1 | 1.7 | 1 | 1.7 | 1.1 | 11.9 | 1.1 | 13.8 | 1.1 | 14.30. | 14 |
80/0.2 | 2.08 | 7.98 | 0.7 | 3.5 | 1.1 | 12.7 | 1.1 | 12.7 | 1.2 | 14.1 | 1.3 | 16.6 | 1.3 | 17.2 | 19 |
56/0.3 | 2.61 | 4.95 | 0.8 | 4.3 | 1.2 | 15.3 | 1.2 | 15.3 | 1.3 | 16.9 | 1.4 | 20 | 20 | 20.7 | 26 |
No. OF WIRE WIRE DIA. m.m. | BUNCH DIA. m.m | Max. CR at 20 0 C Ohm/km | Nominal Insulation THICKNESS m.m. | Approx CORE DIA.m.m. | 14 CORE | 16 CORE | 19 CORE | 37 CORE | APPROX CURRENT RATING AMP. | ||||
Sheath Thick m.m. | O.D m.m. | Sheath Thick m.m. | ODm.m. | SheathThickm.m. | O.D.m.m. | SheathThickm.m. | O.D.m.m | ||||||
16/0.2 | 0.94 | 39 | 0.6 | 2.2 | 1.1 | 12 | 1.1 | 12.6 | 1.1 | 13.2 | 1.2 | 17.8 | 4 |
24/0.2 | 1.2 | 26 | 0.6 | 2.5 | 1.1 | 13.3 | 1.2 | 14.2 | 1.2 | 14.9 | 1.2 | 19.9 | 7 |
32/0.2 | 1.34 | 19.5 | 0.6 | 2.6 | 1.1 | 13.7 | 1.2 | 9.8 | 1.3 | 15.6 | 1.4 | 21 | 11 |
48/0.2 | 1.64 | 13.3 | 0.6 | 2.9 | 1.2 | 15.2 | 1.2 | 1.7 | 1.3 | 17.1 | 1.4 | 23.2 | 14 |
80/0.2 | 2.08 | 7.98 | 0.7 | 3.5 | 1.3 | 18.1 | 1.4 | 12.7 | 1.4 | 20.3 | 1.5 | 27.6 | 19 |
56/0.3 | 2.61 | 4.95 | 0.8 | 4.3 | 1.4 | 21.8 | 1.5 | 23.2 | 1.5 | 24.5 | 1.6 | 33.5 | 26 |
Leveraging our industrial expertise, we are engaged in manufacturing, exporting, and supplying Fire Resistant Cables in national and international domains. These Fire Resistant Cables are extensively used to maintain circuit integrity during and after fire. It is insulated with specially formulated PVC/TPE/XLPE to form a core. Cores are laid together or twisted to form a pair/triad depending upon the individual requirement. Such cores/pairs/triads after laying, they are coated with special Fire Resistant materials and overall sheathed with special PVC/TPE/LSZH.
Shielding with Braiding/Aluminium mylar taping will be done overall or individually depending upon the requirement. Armouring provided depending upon requirement with a extruded inner special PVC/TPE sheath, and overall sheath of special PVC/TPE. Fire Survival Test Identification : Shall be as per cable Type Control/Instrumentation Signal/Thermocouple Extn./Compensating as per their respective features list. Other combinations of colour, numerals and alphabet coding will be provided as per clientâs requirement Standard Specifications :
Characteristics :
Availability : 500 - 1000 meters Special Properties : Zero Halogen Low Smoke insulation and sheath material supplied on request Add for More Details Please Send You Requirements with Technical Details Inquiry Now!!!!!
We have carved a niche as one of the overruling Halogen Free Control Cables Manufacturers, Exporters, and Suppliers based in India. The Halogen Free Control Cables that we offer find their application in electrical installations in dry and damp areas. It is also suitable for interiors and outdoors if UV protection and temperature ranges are observed. These Halogen Free Control Cables are made from top quality raw materials, in order to ensure better performance and durable life.
Applications :
Benefits :The halogen free control cables are oil resistant (SEV TP 20B), widely resistant against chemicals, rough but extremely flexible. The materials are flame retardant and self extinguishing according to IEC 60 332.1, IEC 60 332.2, IEC 60 332.3 :
Specifications :