Our Products
Industrial Pump
2 Products availableOur Complete range of products are Silent Gensets, Single Phase Double Cylinder Air Cooled Generator, Three Phase Double Cylinder Air Cooled Generator, Welding Alternator and Three Phase Generator-KWS-1400.
We offer precisely engineered Silent Gensets that are manufactured from the optimum quality raw materials. Corrosion resistant modular construction of our Silent Generators ensures long lasting life with low maintenance cost. Available with enclosures for temperature safety, our Silent Generator Sets are safe to use. Easy to operate and maintain, our Silent Generator Sets are eco friendly in nature. We are well reckoned as one of the major Silent Gensets Suppliers based in India.
Technical Specification
Model. | K.VA | K.W | Phase | Power Factor | Cooling | Engine BHP |
---|---|---|---|---|---|---|
KSG- 500S | 5 | 5 | Single | 0.8 | water Cool | 10.5 |
KSG- 600S | 6 | 6 | Single | 0.8 | water Cool | 10.5 |
KSG-750S | 7.5 | 6 | Single | 0.8 | water Cool | 10.5 |
KASG- 500S | 5 | 5 | Single | 0.8 | Air Cooled | 12 |
KASG- 600S | 6 | 6 | Single | 0.8 | Air Cooled | 12 |
KASG- 750 | 7.5 | 6 | Single | 0.8 | Air Cooled | 12 |
KSG-625T | 6.25 | 5 | Three | 0.8 | water Cool | 10.5 |
KSG-750T | 7.5 | 6 | Three | 0.8 | water Cool | 10.5 |
KSG-625 | 6.25 | 5 | Three | 0.8 | Air Cooled | 12.5 |
KSG-750S | 7.5 | 6 | Three | 0.8 | Air Cooled | 12.5 |
KASG-1000 | 10 | 8 | Single | 0.8 | Air Cooled | 16 |
KASG-1250 | 12.5 | 10 | Single | 0.8 | Air Cooled | 20 |
KASG-1500 | 15 | 12 | Three | 0.8 | Air Cooled | 20 |
KSG-15S | 15 | 12 | Single | 0.8 | water Cooled | 28 |
KSG-20S | 20 | 16 | Single | 0.8 | water Cooled | 28 |
KSG-30S | 30 | 24 | Single | 0.8 | water Cooled | 37 |
KSG-40S | 40 | 32 | Single | 0.8 | water Cooled | 51 |
KSG-20T | 20 | 16 | Three | 0.8 | water Cooled | 28 |
KSG-30 | 30 | 24 | Three | 0.8 | water Cooled | 37 |
KSG-40 | 40 | 32 | Three | 0.8 | water Cooled | 51 |
Engine
Cooling | Air (Radial) |
No. of Cyl. | Two |
Fuel | H.S. Diesel |
Type | Vertical , 4-stroke, compression ignition |
Speed | 1500 RPM |
Starting | Handle start (Optional-Electrical) |
Fuel tank | 10 to20 liters |
A. C. Generator | |
Voltage | 230/415 V |
Phase | Single/Three |
Frequency | 50 Hz |
Regulation | 5 % Max. |
Insulation | F Class |
Additional Information:
Payment Terms : L/C, T/T
Delivery Time : 7days
Technical Specification
AC Generators (Alternator) | |||||||
Genset Model | Rated Output KVA | Rated Output KW | NO. Of Phase | Rated Current (Amps) | Power Factor | Diesel Engine Rated Power (HP) | Dry Weight (Kg) |
---|---|---|---|---|---|---|---|
KAT 1000 | 10 | 8 | Three | 13.9 | 0.8 (LAG) | 14 | 430 |
KAT 1250 | 12.5 | 10 | Three | 17.4 | 0.8 (LAG) | 16 | 440 |
KAT 1500 | 15 | 12 | Three | 20.8 | 0.8 (LAG) | 20 | 465 |
Cooling | Air (Radial) |
No. of Cyl. | Two |
Fuel | H.S. Diesel |
Type | Vertical , 4-stroke, compression ignition |
Speed | 1500 RPM |
Starting | Handle start (Optional-Electrical) |
Fuel tank | 10 to20 liters |
A. C. Generator | |
Voltage | 230/415 V |
Phase | Single/Three |
Frequency | 50 Hz |
Regulation | ± 5 % Max. |
Insulation | F Class |
Technical Specification
AC Generators ( Alternator ) | |||||||
Genset Model | Rated Output KVA | Rated Output KW | NO. Of Phase | Rated Current (Amps) | Power Factor | Diesel Engine Rated Power (HP) | Dry Weight (Kg) |
---|---|---|---|---|---|---|---|
KAS 800 | 8 | 8 | One | 34.8 | 1.0 (UPF) | 14 | 410 |
KAS 1000 | 10 | 10 | One | 43.5 | 1.0 (UPF) | 16 | 420 |
KAS 1200 | 12 | 12 | One | 52.2 | 1.0 (UPF) | 20 | 47 |
We are expert in manufacturing of Welding Alternator that is high in demand in the national and international markets. Our Industrial Welding Alternator is precisely designed by experienced engineers to suit the specific requirements of the clients. Today, we have carved a niche as one of the leading Welding Alternator Manufacturers and suppliers based in India. Manufactured from the high technology parts, our Industrial Welding Alternator is highly durable as well as efficient. Enclosed with Sound Proofing Canopy, our Industrial Welding Alternator assures no noise pollution.
Specification
Direct Welding Without | |
Type | Transformer |
Welding Voltage | 75/26 V |
Frequency | 50 Hz |
Regulation | ± 5 % |
Insulation | F Class |
Rev. Speed | 1500 RPM |
Technical Specification
Model | KAW - 220 | KAW - 400 |
---|---|---|
Welding Rod Size ( SWG. ) | 12 TO 8.0 | 12 TO 6.0 |
Welding Rod Size ( mm ) | 2.5 TO 4.0 | 2.5 TO 5.0 |
Welding Current (AMPS) | Max. 220 | Max. 400 |
Current Controlling | 4 Steps | 4 Steps |
Single Phase Load AT 230 V | 2.0 KW(8.7 Amp) | 3.0 KW( 13 Amp) |
Recommended Engine Rating | 12.0 H.P. | 20.0 H.P. |
User Sectors | Domestic, Commercial and Industrial | Domestic, Commercial and Industrial |
Application | Direct Online Welding | Direct Online Welding |
Cooling | Water |
No. of Cyl. | Two |
Fuel | H.S. Diesel |
Type | Vertical , 4-stroke, compression ignition |
Speed | 1500 RPM |
Starting | Handle start (Optional-Electrical) |
Fuel tank | 10 to 20 liters |
A. C. Generator | |
Voltage | 230/415 V |
Phase | Single/Three |
Frequency | 50 Hz |
Regulation | 5 % Max. |
Insulation | F Class |
Technical Specification
AC Generators (Alternator) | ||||||||
Model | Rated Output KVA | Rated Output KW | No. of Phase | Volts | Current (Amps) | Power Factor | Diesel Engine Rated Power (HP) | Dry Weight (Kg) |
---|---|---|---|---|---|---|---|---|
KWT 1000 | 10 | 8 | Three | 415 | 13.9 | 0.8 (LAG) | 15 | 480 |
KWT 1250 | 12.5 | 10 | Three | 415 | 17.4 | 0.8 (LAG) | 17.5 | 490 |
KWT 1500 | 15 | 12 | Three | 415 | 20.8 | 0.8 (LAG) | 21.5 | 510 |
KWT 1750 | 17.5 | 14 | Three | 415 | 24.3 | 0.8 (LAG) | 23 | 530 |
KWT� � 20000 | 20 | 16 | Three | 415 | 27.8 | 0.8 (LAG) | 26 | 545 |
Cooling | Water |
No. of Cyl. | Two |
Fuel | H.S. Diesel |
Type | Vertical , 4-stroke, compression ignition |
Speed | 1500 RPM |
Starting | Handle start (Optional-Electrical) |
Fuel tank | 10 to20 liters |
A. C. Generator | |
Voltage | 230/415 V |
Phase | Single/Three |
Frequency | 50 Hz |
Regulation | ± 5 % Max. |
Insulation | F Class |
Technical Specification
AC Generators (Alternator) | ||||||||
Model | Rating KVA | Rating KW | No. of Phase | Volts | Current (AMPS) | Power Factor | Diesel Engine Rating (HP) | Dry Weight Kg |
---|---|---|---|---|---|---|---|---|
KWS 220 | 2.2 | 2.2 | One | 230 | 9.5 | 1.0 (UPF) | 4 | 165 |
KWS 350 | 3.5 | 3.5 | One | 230 | 15.2 | 1.0 (UPF) | 6.5 | 270 |
KWS 500 | 5 | 5 | One | 230 | 21.7 | 1.0 (UPF) | 7.5 | 295 |
KWS 600 | 6 | 6 | One | 230 | 26.1 | 1.0 (UPF) | 10 | 305 |
KWS 750 | 7.5 | 7.5 | One | 230 | 32.6 | 1.0 (UPF) | 12 | 325 |
KWS 850 | 8.5 | 8.5 | One | 230 | 37 | 1.0 (UPF) | 14 | 335 |
Cooling | Water |
No. of Cyl. | One |
Fuel | H.S. Diesel |
Speed | 1500 RPM |
SFC 1 | gms/HP-Hr |
A. C. Generator | |
Voltage | 230/415 V |
Phase | Single/Three |
Frequency | 50 Hz |
Regulation | ± 5 % Max. |
Insulation | F Class |
Mounting | Foot |
Technical Specification
AC Generators (Alternator) | ||||||||
Model | Rating KVA | Rating KW | No. of Phase | Volts | Current (AMPS) | Power Factor | Diesel Engine Rating (HP) | Dry Weight (Kg) |
---|---|---|---|---|---|---|---|---|
KWT 500 | 5 | 4 | Three | 415 | 7 | 0.8 (LAG) | 6.5 | 275 |
KWT 625 | 6.25 | 5 | Three | 415 | 8.7 | 0.8 (LAG) | 7.5 | 285 |
KWT 750 | 7.5 | 6 | Three | 415 | 10.4 | 0.8 (LAG) | 10 | 305 |
KWT 870 | 8.7 | 7 | Three | 415 | 12.2 | 0.8 (LAG) | 12 | 320 |
KWT 980 | 9.8 | 8 | Three | 415 | 13.9 | 0.8 (LAG) | 14 | 338 |
Cooling | Water |
No. of Cyl. | One |
Fuel | H.S. Diesel |
Speed | 1500 RPM |
SFC 1 | gms/HP-Hr |
A. C. Generator | |
Voltage | 230/415 V |
Phase | Single/Three |
Frequency | 50 Hz |
Regulation | ± 5 % Max. |
Insulation | F Class |
Mounting | Foot |
Technical Specification
AC Generators (Alternator) | ||||||||
Model | Rating KVA | Rating KW | NO. Of Phase | Volts | Current (AMPS) | Power Factor | Diesel Engine Rating (HP) | Dry Weight (Kg) |
---|---|---|---|---|---|---|---|---|
KWS 220 | 2.2 | 2.2 | One | 230 | 9.5 | 1.0 (UPF) | 4 | 165 |
KWS 350 | 3.5 | 3.5 | One | 230 | 15.2 | 1.0 (UPF) | 6.5 | 270 |
KWS 500 | 5 | 5 | One | 230 | 21.7 | 1.0 (UPF) | 7.5 | 295 |
KWS 600 | 6 | 6 | One | 230 | 26.1 | 1.0 (UPF) | 10 | 305 |
KWS 750 | 7.5 | 7.5 | One | 230 | 32.6 | 1.0 (UPF) | 12 | 325 |
KWS 850 | 8.5 | 8.5 | One | 230 | 37 | 1.0 (UPF) | 14 | 325 |
Cooling | Air (Radial) |
No. of Cyl. | One |
Fuel | H.S. Diesel |
Type | Vertical , 4-stroke, compression ignition |
Speed | 1500/1800 RPM |
Starting | Handle start (Optional-Electrical) |
Fuel tank | 5 to10 liters |
A. C. Generator | |
Voltage | 230/415 V |
Phase | Single/Three |
Frequency | 50 Hz |
Regulation | 5 % Max. |
Insulation | F Class |
Technical Specification
AC Generators (Alternator) | |||||||
Model | Rated Output KVA | Rated Output KW | No. of Phase | Current (Amps) | Power Factor | Diesel Engine Rated Power (HP) | Dry Weight (Kg) |
---|---|---|---|---|---|---|---|
KAT 500 | 5 | 4 | Three | 7 | 0.8 (LAG) | 6.25 | 270 |
KAT 625 | 6.25 | 5 | Three | 8.7 | 0.8 (LAG) | 7 | 275 |
KAT 750 | 7.5 | 6 | Three | 10.4 | 0.8 (LAG) | 9 | 285 |
KAT 870 | 8.7 | 7 | Three | 12.2 | 0.8 (LAG) | 11 | 305 |
Voltage | 230/415 V |
Phase | Single/Three |
Frequency | 50/60 Hz |
Regulation | 5 % Max. |
Insulation | F Class |
Mounting | Foot |
RPM | 1500/1800 |
Center Height | |
2.2 KVA | 140 MM |
3.5 TO 10 kW | 150 MM |
12 TO 16 kW | 200 MM |
Technical Specification
Alternator Model | Rated Output kVA | Rated Output kW | No. of Phase | Current (AMPS) | Power Factor | Recommended Engine Power (BHP) | Nett Weight (KG) |
---|---|---|---|---|---|---|---|
KSA 220 | 2.2 | 2.2 | One | 9.5 | 1.0 (UPF) | 3.5 | |
KSA 350 | 3.5 | 3.5 | One | 15.2 | 1.0 (UPF) | 6.5 | 69 |
KSA 500 | 5 | 5 | One | 21.7 | 1.0 (UPF) | 8 | 75 |
KSA 600 | 6 | 6 | One | 26.1 | 1.0 (UPF) | 10 | 78 |
KSA 750 | 7.5 | 7.5 | One | 32.6 | 1.0 (UPF) | 12 | 84 |
KSA 850 | 8.5 | 8.5 | One | 37 | 1.0 (UPF) | 14 | 92 |
KSA 1000 | 10 | 10 | One | 43.5 | 1.0 (UPF) | 16 | 95 |
KSA 1200 | 12 | 12 | One | 52.2 | 1.0 (UPF) | 20 | |
KSA 1400 | 14 | 14 | One | 60.9 | 1.0 (UPF) | 23 | |
KSA 1600 | 16 | 16 | One | 69.6 | 1.0 (UPF) | 25 |
Voltage | 230/415 V |
Phase | Single/Three |
Frequency | 50/60 Hz |
Regulation | 5 % Max. |
Insulation | F Class |
Mounting | Foot |
RPM | 1500/1800 |
Center Height | |
2.2 KVA | 140 MM |
3.5 TO 10 kW | 150 MM |
12 TO 16 kW | 200 MM |
Technical Specification
Alternator Model | Rated Output kVA | Rated Output KW | NO. Of Phase | Current (AMPS) | Power Factor | Recommended Engine Power (BHP) | Nett Weight (KG) |
---|---|---|---|---|---|---|---|
KTA 500 | 5 | 4 | Three | 7 | 0.8 (LAG) | 6.5 | 76 |
KTA 625 | 6.25 | 5 | Three | 8.7 | 0.8 (LAG) | 8 | 82 |
KTA 750 | 7.5 | 6 | Three | 10.4 | 0.8 (LAG) | 10 | 85 |
KTA 870 | 8.7 | 7.5 | Three | 12.2 | 0.8 (LAG) | 12 | 90 |
KTA 1000 | 10 | 8.5 | Three | 13.9 | 0.8 (LAG) | 14 | 100 |
KTA 1250 | 12.5 | 10 | Three | 17.4 | 0.8 (LAG) | 16 | 104 |
KTA 1500 | 15 | 12 | Three | 20.8 | 0.8 (LAG) | 20 | |
KTA 1750 | 17.5 | 14 | Three | 24.3 | 0.8 (LAG) | 23 | |
KTA 2000 | 20 | 16 | Three | 27.8 | 0.8 (LAG) | 25 |