Our Products
Our product range contains a wide range of Gas Fired Hot Air Generator, Hot Water Generato and Heat Exchanger, Airotherm, Gas Fired Hot Water Generators and Hot Air Generator
Airotherm is a combination of shell-in-shell and tube-in-shell type hot air generator. It has four concentric shells. The furnace shell has a blind end where the flue gases are reversed over the flame itself forming the 1st and 2nd pass. The 3rd pass is situated between the 2nd &3rd shell from where the flue gases, led via a duct, to the tube-in-shell type heat exchanger. The 4th & 5th pass are through tubes of the tube-in-shell heat exchanger. The burner assembly is bolted on a removable inner cover plate. The combustion air is led to an air register which is formed by the annular space of the inner cover and the outer cover. The air going for combustion is thus preheated.
The fresh air has four passes to absorb heat from the flue gases. The 1st pass of the cold air enters around the 5th pass of the flue gases. Likewise all the subsequent passes of the air and flue are in counter current mode enabling maximum heat transfer. The final 4th pass of the fresh air which is at the last leg of the heat transfer path wraps around the furnace in circular path absorbing the heat attaining the required temperature for the process. The max temp for this model of heater is 300 The design of the heater is made simple and operator friendly.
We manufacture hot water generator for variety of fuels including solid fuels. We also manufacture heat excahnger with following types:
Our range of heat exchangers includes
Airotherm is a combination of shell-in-shell and tube-in-shell type hot air generator. It has four concentric shells. The furnace shell has a blind end where the flue gases are reversed over the flame itself forming the 1st and 2nd pass. The 3rd pass is situated between the 2nd & 3rd shell from where the flue gases, led via a duct, to the tube-in-shell type heat exchanger. The 4th & 5th pass are through tubes of the tube-in-shell heat exchanger.
The burner assnmbly is bolted on a removable inner cover plate. The combustion air is led to an air register which is formed by the annular space of the inner cover and the outer cover. The air going for combustion is thus preheated.
The fresh air has four passes to absorb heat from the flue gases. The 1st pass of the cold air enters around the 5th pass of the flue gases. Likewise all the subsequent passes of the air and flue are in counter current mode enabling maximum heat transfer. The final 4th pass of the fresh airwhich is at the last leg of the heat transfer path wraps around the furnace in circular path absorbing the heat attaining the required temperature for the process. The max: temp for this model of heater is 300
The design of the heater is made simple and operator friendly.
We offer Gas Fired Hot Air Generators that are widely used in high temperature applications. The compact design of the product saves a lot of space as it rugged construction ensures high performance for longer period of time.
Gas Fired Hot Water Generator is a very compact fully automatic packaged hot water generator in ready to install condition and can be installed where ever space is available. It does not require any special room like boiler house. It falls outside the purview of Indian Boiler Regulations. WATERTHERM is a safer and economical system which delivers hot water much faster than any other conventional system. It's most ideal usage includes HOTELS, HOSPITALS, RESIDENTIAL COMPLEX, LAUNDRY, DAIRY INDUSTRIES, etc. where continuous hot water supply is essentially required. WATERTHERM system is available in wide range of heat output from 70, 000 kcals/hr. to 10, 00, 000 kcal/hr., to give output of 1250 ltrs/hr. to 18, 200 ltrs/hr. of hot water at about 65c temperature.
A New Perception In QualitySmall Capacity Models Wt-30 & Wt-50 Are Sleek, Compact And Instant Hot Water Generator Exclusively Designed For Hotels, Resorts, Dairies & Hospitals.
Benefitskerone offers a range of Hot Water Generator for various applications and usages. We are manufacture of goods on vast scale by machinery Hot Water Generators for a variety of fuels including solid fuels. Heat exchangers are available in Several ranges such as Condensers, Vent Condensers, Re-boilers and Sub-coolers depending upon process demand. It also can be customized according to the customers specification and can be used in vast number of applications.
A fully automatic multi pass counter current Hot Air Generator consist of stainless steel shell type integral combustion chamber accommodated in multi M.S. shell. The cold air is inserted by a suitable capacity blower fan in first pass, absorbs heat from flue gas passage and accordingly both hot flue gas and cold air travel in opposite direction in the passage which ultimately transfers 90% heat to cold air and delivers hot air from hot air outlet hole. The system functions fully automatic on temperature sensing device installed at hot air outlet which ON-OFF the burner at pre-set temperature. the system is a package type unit, fixed on common base frame.
ApplicationThis equipment is suitable for supplying dry air which keeps the power equipment's inner parts from moisture in the maintenance of transformer, reactor and other big power facilities. Maintenance staff will not be short of oxygen working inside the equipment. It is more reliable, economic, convenient and safer than nitrogen.
Item | Parameter | Model Unit | |||||
---|---|---|---|---|---|---|---|
Technical Parameter | Flow | M3/h | 50 | 100 | 150 | 200 | |
Working Pressure | Mpa | 0.6~0.8 | |||||
Pressure Drop | Mpa | 0.05 | |||||
Noise | dB(A) | 70 | |||||
Working Power | KW | 380V-50Hz 3 Phase 4 Wire | |||||
Total Power | KW | 12 | 19 | 22 | 26 | ||
Size | Length | cm | 215 | 215 | 230 | 230 | |
Width | cm | 155 | 155 | 165 | 165 | ||
Height | cm | 230 | 230 | 230 | 230 | ||
Diameter | DN | 32 | 40 | 50 | 50 | ||
Weight | Kg | 900 | 980 | 1030 | 1050 | ||
After Treatment Index | Discharge Pressure | Mpa | 0.02~0.03 | ||||
Dew Point | °C | -50°C ~ -70°C | |||||
Particle | um | 0.01 | |||||
Oil content in air outlet | ppm | 0.01 |