Power Transformers

We offer the best product range of Medium Voltage Indoor Resin Cast Voltage Transformer, Low Voltage Indoor Resin Cast Current Transformer and Medium Voltage Outdoor Cycloaliphatic Resin Cast Voltage Transformer.

Medium Voltage Indoor Resin Cast Voltage Transformer

  • Min. Order (MOQ) 1 Piece
  • Casting Epoxy Resin
  • Highest Current For Equipment(kV) Up to 36Kv
  • Rated Insulation Level(kV) Up to 36/70/170kVp
  • Rated Frequency(Hz) 50-400Hz
  • No of Phases 1-Phase or 3-Phase
  • Rated Primary Voltage(V) Up to 33kV
  • Rated Secondary Voltage(V) 110V/RT3, 110V/3, 110V(As Per Requirement)
  • Accuracy Class 0.1, 0.2, 0.5, 1, 3
  • Rated Burden(VA) Up to 500VA
  • Accuracy Class of Protection Core 3P and 6P
  • Number of Windings 1-2-3-4-5
  • Class of Insulation Class B, F & H
  • Voltage Factor 1.2 Continuous/1.5 for 30 sec, 1.9 for 8 hours
  • Type of Earthing One End Earthed Type(E-N) / UN Earthed Type(U-N)
  • Applicable Standards IS, IEC, ANSI, BS, etc.
View Complete Details

Low Voltage Indoor Resin Cast Current Transformer

  • Min. Order (MOQ) 1 Piece
  • Type Wound Primary/Ring/Rectangular
  • Finishing Tape Insulated/Epoxy Resin/cycloaliphatic
  • Class Of Insulation Class B, F & H
  • Highest Voltage for Equipment (kV) 1.1kV
  • Rated Insulation Level (kV) 1.1 / 4kV
  • Rated Frequency (Hz) 50-400Hz
  • Rated Primary Current (A) Up to 25000A
  • Rated Secondary Current(A) 5A or 1A
  • Accuracy Class 0.1, 0.2s, 0.2, 0.5s, 0.5, 1, 3, 5
  • Instrument Safety Factor <=5 (Depending on Accuracy Class)
  • Rated Burden (VA) Up to 30VA (As Per Requirement)
  • Accuracy Class of Protection Core 5P to 15P
  • Accuracy Limited Factor(ALF) 5 to 30
  • Special Protection(PS/PX) VK=> .v(As Per Requirement)
  • Number of Cores 1-2-3-4-5
  • Applicable Standards IS, IEC, ANSI, BS, etc.
View Complete Details

Medium Voltage Outdoor Cycloaliphatic Resin Cast Voltage Transformer

  • Min. Order (MOQ) 1 Piece
  • Number Of Cores 1-2-3-4-5
  • Application Outdoor
  • Type Wound Primary / Window Type
  • Casting Cycloaliphatic Epoxy Resin
  • Highest Current For Equipment(Kv) Up to 36kV
  • Rated Insulation Level(Kv) Up to 36/70/170kVp
  • Rated Frequency(Hz) 50-400Hz
  • Rated Primary Current(A) Up to 10000A
  • Rated Secondary Current(C) 5A or 1A
  • Accuracy Class 0.1, 0.2s, 0.2, 0.5s, 0.5, 1, 3, 5
  • Instrument Safety Factor <=5 (Depending on Accuracy Class)
  • Rated Burden (VA) Up to 30VA (As Per Requirement)
  • Accuracy Class of Protection Core 5P to 15P
  • Accuracy Limited Factor(ALF) 5 to 30
  • Special Protection(PS/PX) VK=> .v(As Per Requirement)
  • Short Time Thermal Current(STC) >Up to 40 kA at 0.5sec 1, sec or 3 sec
  • Class of Insulation Class B, F & H
  • Applicable Standards IS, IEC, ANSI, BS, etc.
View Complete Details