Post Buy Requirement
Kalpa Electrikal Pvt Ltd

Kalpa Electrikal Pvt Ltd

gstGST : 29AAACK7799P1ZD Verified Add Review

Other Products / Services

We are leaders in the market for providing best range of

Oil Immersed Distribution Transformer

  • Min. Order (MOQ) 1 Piece
  • Frequency 50/60 Hz
  • Construction Type Indoor/Outdoor
  • Duty Type Outdoor / Indoor, Pole or Ground Mounted
  • Voltage Class 3.3, 6.6, 11, 22, 33kV or any specific
  • No of Phases 1 or 3 Phase, ONAN, KNAN
  • Capacity Up to 10MVA
  • Insulating Fluid PCB FREE Mineral Oil, both inhibited & Biodegradable FR3, uninhibited as per IS335/IEC60296
  • Class of Insulation Class A
  • Tap Changer Off Circuit or On Load
  • Tapping Range OCTC or OLTC as per customer requirement
  • Winding Material Aluminum or Copper with multi paper covering
  • Applicable Standards IS 1180 , IS 2026, IEC 60076, ANSI, IEEE
  • Painting Enamel, Epoxy, Polyurethane or customer specific

Kalpa offers a complete line of oil cooled three-phase distribution transformers that meet applicable IS / IEC standards. With high voltages up to 33kV and ratings up to 10 MVA, transformers are designed for outdoors covering domestic, International , commercial and industrial applications. High-grade materials, combined with sophisticated engineering design systems and state of the art test infrastructure are key elements of a transformer that will deliver years of highly reliable service.

  • Design can meet any stringent specifications
  • Offering low losses as per request. As per IS1180/EEL - 1, 2 & 3 BEE STAR RATING
  • Capacity to Execute large volume orders.


Assured Features

  • Highest dielectric insulation property to withstand Lightening Impulse
  • Mechanical design to withstand short circuit forces arising during faults
  • Optimum oven heating under vacuum as to achieve desired compression height and maximum insulation resistance (IR) to windings
  • Adequate ducts between layers, coils, discs for maximum oil flow and reduced hot spot temperature.
  • Step-lap designed CRGO laminations for lower losses and excitation current
  • Pre-compressed Insulation material for minimal moisture absorption


Standard Fittings

  • H.V. Cable box
  • L.V. Cable box with bus bar or bus duct
  • Off circuit tap links
  • Conservator oil filling hole With cap & drain plug
  • Undercarriage with four Bi-directional rollers
  • Earthing terminals
  • Drain cum bottom filter Valve with sampling plug
  • Top filter valve with Sampling plug
  • Plain Oil Level Gauge
  • Rating diagram plate
  • Air release device
  • Thermometer Pocket
  • Lifting lugs
  • Pressed Steel Radiators (Fins or corrugated type)
  • Double Diaphragm explosion vent
  • Silica gel breather
  • Additional Neutral bushing
  • First filling of oil


Optional Fittings

  • Detachable Radiators with isolating valves
  • Jacking Pads
  • Dial type Oil Temperature Indicator With A/T contacts
  • Dial type Winding Temperature Indicator with A/T contacts
  • Magnetic Oil Gauge with A/T contactsw
  • Buchholz relay with A/T contacts
  • Marshaling box with control wiring
  • Equalizer pipe between Conservator & explosion vent
  • On Load Tap Changer
  • RTCC Panel with automatic Voltage Regulator (AVR)
  • Pressure Release valve
  • DGPT Relay
View Complete Details

Line Chokes And Reactors

  • Min. Order (MOQ) 1 Piece
  • Certification ISI Certified, ISO 9001:2008 Certified
  • Feature Easy To Install, Electrical Porcelain, Four Times Stronger, Proper Working, Sturdy Construction
  • Output Type AC Single Phase, AC Three Phase
  • Tensile Strength 0-25Mpa, 25-50Mpa, 50-75Mpa
  • Country of Origin India
  • Production Power 100-250kw, 250-500kw

Kalpa Offers a Wide variety of Reactors, sometimes also known and Inductors or Chokes, for multiple applications are manufactured at Kalpa. A few among them are Filter Reactor, Detuned reactors, Series Reactor, Input/output Reactors. All the products are made as per Indian or International Standards (IS, IEC) or as per Customer requirements/ Application. All the manufacturing, testing and evaluation facilities are available in house

Our Range of reactors Include

  • Detuned reactors
  • Series Reactor
  • Input/output Reactor
  • Detuned Filter Reactor
  • Air Core /Iron core Reactors
View Complete Details

Cast Resin Type Dry Type Transformer

  • Min. Order (MOQ) 1 Piece
  • Frequency 50/60 Hz
  • Capacity UPTO 2.5 MVA
  • Class Of Insulation Class B/F/H with Temp Rise of 70/90/115 Deg C or as per customer requirement.
  • Tapping Range OCTC or OLTC As Per Customer Requirements
  • Winding Material Copper
  • Duty Type Outdoor / Indoor , Convertor Duty, Special Type
  • Voltage Class UPTO 33 kV
  • No of Phases 1 Phase or 3 Phase
  • Vector Group Dyn1 or Dyn5 or Dyn11 or any other connection as per customer requirement.
  • Tap Changer Off Circuit or On Load.
  • Applicable Standards IS 11171, IEC 60076
  • Painting Painting : Powder Coated with RAL 7032 Shade or As Per Customer Requrement
  • Degree of protection IP 23, 43 or As Per customer requirement.
  • Duty Type Outdoor/Indoor, Convertor Duty, Special Type

At Kalpa Electrikal Pvt Ltd, casting method of these transformers is obtained with the combined action of vacuum and temperature. The casting method makes it possible to assure void-free epoxy penetration of both the inner layer and between turn insulation. These Transformers are specifically needed in the distribution network for feeding basements or stilts of high-rise buildings, hotels, Malls, stadi-um, airports, chemical & refinery plants.

Assured Features

  • Windings are electrically balanced to minimize axial short circuit forces.
  • Coils are held rigidly in place between insulators clamped to the upper and lower core frames under highcompression.
  • Precise casting under vacuum ensuring low partial discharge.
  • Smooth surface finish and robust construction of MV & LVcastCoils.
  • Adequate ducts between coils, discs for maximum airowand reducedhotspotTemperature.
  • Step-lap designed CRGO laminations for lower losses and excitationcurrent.


Standard Fittings

  • H.V. Cable box.
  • L.V. Cable box with bus bar or bus duct
  • Off circuit tap links.
  • Undercarriage with four Bi-directional rollers.
  • Earthing terminals.
  • Rating and diagram plate.
  • Lifting lugs for complete Transformer
  • Tapping link operation door
  • Enclosure with louvre panels
  • Canopy
  • Base channel 2 Nos
  • The separate neutral bushing on LV side
  • Paint: Powder coated With RAL7032 Shade


Optional Fittings

  • RTD with A/T contact.
  • Marshaling box with control wiring.
  • On Load tap changer.
  • Forced Cooling arrangement.
  • Neutral Current Transformer.


Safety Features

  • Environment-Friendly
  • Fire Resistance
  • Non-Hygroscopic
View Complete Details

Vacuum Pressure Impregnated Dry Type Transformer

  • Min. Order (MOQ) 1 Piece
  • Capacity Up to 5MVA
  • Frequency 50/60Hz
  • Class Of Insulation Class B/F/H with Temp Rise of 70/90/115 Deg C or as per customer requirement.
  • Tapping Range OCTC or OLTC As Per Customer Requirements
  • Winding Material Copper
  • Duty Type Outdoor/Indoor, Ground Mounted AN/AF
  • Voltage Class UPTO 11 kV
  • No of Phases 1 Phase or 3 Phase
  • Vector Group Dyn1 or Dyn5 or Dyn11 or any specification.
  • Tap Changer Type Off Circuit or On Load.
  • Applicable Standards IS 11171, IEC 60076
  • Enclosure Painting Powder coated with RAL 7032 shade or as per customer requirement
  • Degree of Protection Ip 23, 43 or as per Customer Requirement.

We Kalpa Electrikal Pvt Ltd manufacture conventional open enclosure type vacuum pressure impregnated dry Transformers. These Transformers are specifically needed in the distribution network for feeding basements or stilts of high-rise buildings, hotels, Malls, stadium airports, chemical & refinery plants.

Assured Features

  • Windings are electrically balanced to minimize axial short circuit forces.
  • Coils are held rigidly in place between insulators clamped to the upper and lower core frames under high compression.
  • Precise casting under vacuum ensuring low partial discharge.
  • Smooth surface finish and robust construction of MV & LV cast Coils.
  • Adequate ducts between coils, discs for maximum air ow and reduced hot spot Temperature.
  • Step-lap designed CRGO laminations for lower losses and excitationcurrent.


Standard Fittings

  • H.V. Cable box.
  • L.V. Cable box with bus bar or bus duct
  • Off circuit tap links.
  • Undercarriage with four Bi-directional rollers.
  • Earthing terminals.
  • Rating and diagram plate.
  • Lifting lugs for complete Transformer
  • Tapping link operation door
  • Enclosure with louvre panels
  • Canopy
  • Base channel 2 Nos
  • The separate neutral bushing on LV side
  • Paint: Powder coated With RAL7032 Shade


Optional Fittings

  • RTD with A/T contact.
  • Marshaling box with control wiring.
  • On Load tap changer with RTCC Panel with AVR
  • Forced Cooling arrangement.
  • Neutral Current Transformer.
  • Space heaters for core & windings


Safety Features

  • Environment-Friendly
  • Fire Resistance
  • Non-Hygroscopic
View Complete Details

Medium Voltage Outdoor Oil Filled Voltage Transformer

  • Min. Order (MOQ) 1 Piece
  • Accuracy Class 0.1, 0.2, 0.5, 1, 3
  • Application Outdoor
  • Highest Voltage for Equipment (kV) Up to 36 kV
  • Rated Insulation Level (kV) Up to 36/70/170kVp
  • Rated Frequency (Hz) 50-400Hz
  • Rated Primary Voltage(V) Up to 33kV
  • Rated Secondary Voltage(V) 110V/RT3, 110V/3, 110V (As Per Requirement)
  • Rated Burden (VA) Up to 500VA
  • Accuracy Class of Protection Core 3P to 6P
  • Number of Windings 1-2-3-4-5
  • Voltage Factor 1.2 Continuous/1.5 for 30 sec, 1.9 for 8 hours
  • Type of Earthing One End Earthed Type (E-N)/ UnEarthed Type (U-N)
  • Class of insulation Class A
  • Applicable Standards IS, IEC, ANSI, BS, etc.
View Complete Details