Our Products
PH Meter
2 Products availablePhoto Meters
2 Products availablePrecision Balance
2 Products availableWeighing Scales & Measuring Tapes
1 Products availableSoil Testing Equipment
1 Products availableLaboratory Apparatus
1 Products availableNitrogen & Oxygen Gas Plant
1 Products availableLab Instrument
1 Products availableWe are leaders in the market for providing best range of Elico Spectrophotometer, L-2700 UV-VIS UV-VIS Spectrophotometer, UV 1900 UV-VIS Spectrophotometer, ECIL Model-4141 Atomic Absorption Spectrophotometer and iCE Fios Atomic Absorption Spectrophotometer
The Thermo Scientific™ iCE FIOS AAS incorporates a unique ten lamp carousel that enables the measurement of a wide range of elements, expanding your AAS analysis. The flame atomizer combined with the dual beam optical system enables the analysis of elements in the concentration range of sub ppm to %.
Easy-access ten lamp carousel with the capability to read coded lamps High light transmission for high precision and accuracy
The iCE FIOS AAS instrument is an ideal solution for laboratories that analyze a number of elements in samples at varying concentration ranges.
SHIMADZU ATOMIC ABSORPTION SPECTROPHOTOMETER (AAS)MANUFACTURE BY SHIMADZU CORPORATION; JAPANHSN Code: 90273020Main Unit Optics Wavelength range: 185 to 900 nm Monochromator: Aberration-corrected Czerny-Turner mounting, Number of grating grooves: 1800 lines / mm, Focal length: 300 mm Band width: 0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm (6-step automatically switching)Detector: Photomultiplier tube Configuration: Optical double beam (with Beam Manager)Background correction method:BGC-SR (high-speed self-reversal method) (185.0 to 900.0 nm)BGC-D2 (D2 lamp method) (185.0 to 430.0 nm)Number of HC lamps: 8-lamp turret, 2 lamps simultaneously lit, 1 formeasurement, 1 warming up for next measurement 2 sockets forHigh-performance boosted lamp, litting one Lamp mode: EMISSION, NON-BGC, BGC-D2, BGC-SRData processing* Software requirements: Microsoft Windows 7 Professional / Vista Business* Parameter setting: Wizard method* Measurement mode: Flame continuous method, flame microsampling method, furnace method, flame emission method Calibration mode:Calibration curve method (select primary, secondary, tertiary)Standard addition method, simple standard addition method(primary expression)Repeat analysis: Up to 20 repetitions. Mean value, standard deviation (SD) and coefficient of variation (RSD) display Automatic exclusion of deviant values by setting SD and %RSD Baseline correction: Automatic correction of baseline drift by offset correction in peak height / peak area modes.Signal processing: segment setting Signal processing segments canbe changed in peak height / peak area modes.Sensitivity correction: Automatic calibration curve correction functionusing sensitivity monitoringAnalog output: 2 channels (atomic absorption/energy signal, background signal) Output range: 5.0, 2.5, 1.25, 0.625 Abs./V (eachsettable in 4 stages)902711510000/-Fixed at 1 V F.S. in EMISSION mode.Calculation factor: Final concentration calculations based onsampled volume, dilution rate, fixed volume, and factor inputsMethod file: Template functions availableProcedure/result display: MRT (Measurement Results Table)worksheetReport generation: Summary reportQA/QC: Select whether to continue or discontinue measurementsbased on results of evaluation on coefficient of correlation, %RSD, ICV.ICB, CCV.CCB, PB, LCS, SPK, PDS, and DUP.Re-analysis: · Select whether or not to conduct re-analysis.(Flame micro sampling method, furnace method)Digital recording:* Management by login ID and password* Control user access authority by user level* Log record* Audit trail* Electronic signaturesPower requirements: Choose from 100, 120, 220, or 230 VAC, 230VA, 50/60 Hz (Power is required separately for the personalComputer.)Dimensions and weight: W702 × D610 × H702 mm, 78 kg(Protruding parts and optional equipment are not included.)Ambient temperature / humidity: 10 to 35 °C, 20 to 80% (less than 70% when temperature is higher than 30 °C
7800 to 400 cm-1, Resolution: Better than 0.5cm-1, Wave number Precision: ±0.01cm-1, Scanning Speed: 0.22.5 cm-1/s, Automatically optimized for detector type or manually adjustable for specific applications, Signal to noise ratio: better than 15, 000:1 (RMS value, at 2100cm-1, resolution: 4cm-1, detector:DTGS, 1minute data collection) Beam splitter: Ge coated KBr, Infrared Source: External, air-cooled, highefficiency Reflex Sphere module, Detector: DTGS, MCT (optional), Data System:Compatible computer, Software:FT-IR software contains all routines needed for basic spectrometer operations. Including library search, quantitation and spectrumThree stages of quality checking before dispatch.