Post Buy Requirement
JR
Chennai, Tamil Nadu, India
Add Review

Industrial Heaters #812008

Industrial Immersion Heaters

IMMERSION HEATERS are designed to be attached to flat surfaces of tanks or mating flanges in order to heat liquids. The number of hairpin-shaped elements varies according to wattage and size of flangeL, Incoloy for immersion in materials corrosive to copper and stainless steel and high heat environments (to1600o F), Stainless Steel for environments corrosive to copper (1200oF), Copper for water heating and Liquids not corrosive to copper (to 350o F).
View Complete Details

Heating Mantle

250 /Piece Get Latest Price
  • Application Chemical Industry
  • Power Supply 220/240V, 50 Hz AC
View Complete Details

Industrial Heaters

HEATERS, 1 12 wide, were originally designed to fit grooved 1 12 wide channels, earning them the name Channel Heaters.Stainless steel sheath resistant to deterioration from exposure to chemicals and contaminants, Ceramic insulation MgO (magnesium oxide) high purity with excellent heat transfer capability when compacted, Nickel-chromium (8020) resistance wire coiled on custom machines assuring accurate rating.
View Complete Details

Nozzle Heaters

Replacement heater for most injection molding machines, High temperature lead wires, Rugged 22-gauge pressure plate, Rust-resistant paint lock sheath, Nickel-plated lockup nuts and bolts, Pem nuts mechanically pressure-fit in flange for ease of installation.
View Complete Details

Nozzle Flange Lockup

Replacement heater for most injection molding machines. English and metric sizes.
Rugged 22-gauge pressure plateRust-resistant paint lock sheathNickel-plated lockup nuts and boltsMica plate insulation with high dielectric strengthHigh temperature lead wires
Pem nuts mechanically pressure-fit in flange for ease of installation.
View Complete Details

Flange Lockup

Application
  • Replacement heater for most injection molding machines

Features
  • English and metric sizes
Standard Construction
  • Rugged 22-gauge pressure plate
  • Rust-resistant paint lock sheath
  • Nickel-plated lockup nuts and bolts
  • Mica plate insulation with high dielectric strength
  • High temperature lead wires
  • Pem nuts mechanically pressure-fit in flange for ease of installation
View Complete Details

Strap Lockup

Application
  • Replacement heater for most injection molding machines
Features
  • English and metric sizes
  • 22 sizes and ratings in stock
  • Low cost
Standard Construction
  • Rust-resistant, Aluminized steel sheath
  • Stainless steel strap and trunion lockup
  • Mica plate insulation with high dielectric strength
  • High temperature lead wires
View Complete Details

Wedge Lockup

Application
  • Low profile heater for industrial users with clearance problems
Features
  • Low profile (3/16 clearance needed)
  • Easy to install and remove
  • Key fits smoothly over band for firm, tight lockup
  • No nuts, bolts or straps needed
  • Lead location opposite gap
  • Rust-resistant sheath
Standard Construction
  • One-piece
  • 1/8 gap
  • Stainless steel key lockup
  • Watt density 25-40 WSI
View Complete Details

Thermocouple Holes

Thermocouple holes (7/16 minimum) can be specified anywhere on the heater surface to accommodate a bayonet thermocouple. A gap of 5/8 at the lockup can be specified for thermocouple insertion through the gap to a threaded hole in the cylinder using a bayonet adapter.

Spot Welded

Threaded fittings can be spot welded to the heater surface if a threaded hole does not exist on heater surface. Consult our IHCO application engineer about spot welded fittings on a heater (6 ID miniumum).

Standoff Bracket

Threaded fittings on a standoff bracket are common on European style heaters. They are suitable for small diameter and/or width heaters that will not accommodate fittings spot-welded to the heater surface.

View Complete Details

Pyrorod Tubular Heaters

Features
  • BENDING: IHCO uses the latest construction techniques and forming machinery to bend Tubular heaters to most any shape.
  • SERVICE LIFE: Pyrorod Tubular heaters are proven to be more resistant to contamination and abuse and have a long anticipated service life when properly used.
  • PERFORMANCE: Quick to respond to controls, Pyrorod heaters are used in many critical environments. They can be manufactured in a wide variety of ratings to perform under adverse conditions.
  • EFFICIENCY: Pyrorod heaters save energy costs in many applications, and are competitively priced with other brands of tubular heaters.
  • VERSATILITY: Due to a variety of sheath materials, electrical and mechanical variations, sizes, and use as Conduction, Immersion or Radiant Heaters, IHCO PYROROD TUBULAR HEATERS are widely found in household, industrial and commercial settings.

Standard Construction

Sizes:

.440, .315, .250, .197(5 mm), .157(4mm), and .118(3mm) Outside Diameter

Material:

Stainless Steal(All Sizes) or Inconel Tubing(.440, .315, and .250 Only)80/20 Nichrome Resistance wireHigh Purity MGO

View Complete Details

Cast Strip Plate Heater

CAST STRIP HEATERS AND CAST PLATE HEATERS are tubular heaters cast in aluminum or bronze alloy.

Application
  • Extrusion dies
  • Flat machinery parts
  • Sealing applications
  • Platens
Features
  • Contamination proof
  • Rugged construction
  • 10-32 screw terminals
  • 1 thick
  • .440 tubular heater

View Complete Details

Flanged

IHCO FLANGED IMMERSION HEATERS are designed to be attached to flat surfaces of tanks or mating flanges in order to heat liquids. The number of hairpin-shaped elements varies according to wattage and size of flange.

Construction and Features

FLANGE

  • Material and rating- 150 pound Carbon steel (sizes available: 3, 4, 5, 6)
Elements

SHEATH MATERIAL

  • Sizes available: .440, .315

HOUSING

  • Incoloy for immersion in materials corrosive to copper and stainless steel and high heat environments (to1600o F)
  • Stainless Steel for environments corrosive to copper (1200oF)
  • Copper for water heating and Liquids not corrosive to copper (to 350o F)
  • NEMA 1- without thermostat options

TEMPERATURE CONTROL

  • Thermostat option (see previous page)
  • Thermocouple may be spot welded to element sheath

CIRCUITS

  • Single-phase: one or two elements
  • Three-phase: three, six or nine elements
  • Number of elements possible by Flange size:3- 1, 2 or 34- 2, 3, 4 or 65- 2, 3, 4, 6, 8 or 96- 2, 3, 4, 6, 8 or 9
View Complete Details

Ceramic Band Heater

  • Application Chemical Industry
  • Max. Power 7 watts per sq. cm
  • Max. Temperature 250 degree C
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Industrial Heaters from Chennai, Tamil Nadu by J R INDUSTRIAL HEATERS
Post Buy Requirement
JR

J R INDUSTRIAL HEATERS Chennai, Tamil Nadu

Chennai, Tamil Nadu, India
Add Review

Industrial Heaters #812008

Our product range contains a wide range of industrial immersion heaters, Heating Mantle, Industrial Heaters, Nozzle Heaters and Nozzle Flange Lockup

Industrial Immersion Heaters

IMMERSION HEATERS are designed to be attached to flat surfaces of tanks or mating flanges in order to heat liquids. The number of hairpin-shaped elements varies according to wattage and size of flangeL, Incoloy for immersion in materials corrosive to copper and stainless steel and high heat environments (to1600o F), Stainless Steel for environments corrosive to copper (1200oF), Copper for water heating and Liquids not corrosive to copper (to 350o F).
View Complete Details

Heating Mantle

250 /Piece Get Latest Price
  • Application Chemical Industry
  • Power Supply 220/240V, 50 Hz AC
View Complete Details

Industrial Heaters

HEATERS, 1 12 wide, were originally designed to fit grooved 1 12 wide channels, earning them the name Channel Heaters.Stainless steel sheath resistant to deterioration from exposure to chemicals and contaminants, Ceramic insulation MgO (magnesium oxide) high purity with excellent heat transfer capability when compacted, Nickel-chromium (8020) resistance wire coiled on custom machines assuring accurate rating.
View Complete Details

Nozzle Heaters

Replacement heater for most injection molding machines, High temperature lead wires, Rugged 22-gauge pressure plate, Rust-resistant paint lock sheath, Nickel-plated lockup nuts and bolts, Pem nuts mechanically pressure-fit in flange for ease of installation.
View Complete Details

Nozzle Flange Lockup

Replacement heater for most injection molding machines. English and metric sizes.
Rugged 22-gauge pressure plateRust-resistant paint lock sheathNickel-plated lockup nuts and boltsMica plate insulation with high dielectric strengthHigh temperature lead wires
Pem nuts mechanically pressure-fit in flange for ease of installation.
View Complete Details

Flange Lockup

Application
  • Replacement heater for most injection molding machines

Features
  • English and metric sizes
Standard Construction
  • Rugged 22-gauge pressure plate
  • Rust-resistant paint lock sheath
  • Nickel-plated lockup nuts and bolts
  • Mica plate insulation with high dielectric strength
  • High temperature lead wires
  • Pem nuts mechanically pressure-fit in flange for ease of installation
View Complete Details

Strap Lockup

Application
  • Replacement heater for most injection molding machines
Features
  • English and metric sizes
  • 22 sizes and ratings in stock
  • Low cost
Standard Construction
  • Rust-resistant, Aluminized steel sheath
  • Stainless steel strap and trunion lockup
  • Mica plate insulation with high dielectric strength
  • High temperature lead wires
View Complete Details

Wedge Lockup

Application
  • Low profile heater for industrial users with clearance problems
Features
  • Low profile (3/16 clearance needed)
  • Easy to install and remove
  • Key fits smoothly over band for firm, tight lockup
  • No nuts, bolts or straps needed
  • Lead location opposite gap
  • Rust-resistant sheath
Standard Construction
  • One-piece
  • 1/8 gap
  • Stainless steel key lockup
  • Watt density 25-40 WSI
View Complete Details

Thermocouple Holes

Thermocouple holes (7/16 minimum) can be specified anywhere on the heater surface to accommodate a bayonet thermocouple. A gap of 5/8 at the lockup can be specified for thermocouple insertion through the gap to a threaded hole in the cylinder using a bayonet adapter.

Spot Welded

Threaded fittings can be spot welded to the heater surface if a threaded hole does not exist on heater surface. Consult our IHCO application engineer about spot welded fittings on a heater (6 ID miniumum).

Standoff Bracket

Threaded fittings on a standoff bracket are common on European style heaters. They are suitable for small diameter and/or width heaters that will not accommodate fittings spot-welded to the heater surface.

View Complete Details

Pyrorod Tubular Heaters

Features
  • BENDING: IHCO uses the latest construction techniques and forming machinery to bend Tubular heaters to most any shape.
  • SERVICE LIFE: Pyrorod Tubular heaters are proven to be more resistant to contamination and abuse and have a long anticipated service life when properly used.
  • PERFORMANCE: Quick to respond to controls, Pyrorod heaters are used in many critical environments. They can be manufactured in a wide variety of ratings to perform under adverse conditions.
  • EFFICIENCY: Pyrorod heaters save energy costs in many applications, and are competitively priced with other brands of tubular heaters.
  • VERSATILITY: Due to a variety of sheath materials, electrical and mechanical variations, sizes, and use as Conduction, Immersion or Radiant Heaters, IHCO PYROROD TUBULAR HEATERS are widely found in household, industrial and commercial settings.

Standard Construction

Sizes:

.440, .315, .250, .197(5 mm), .157(4mm), and .118(3mm) Outside Diameter

Material:

Stainless Steal(All Sizes) or Inconel Tubing(.440, .315, and .250 Only)80/20 Nichrome Resistance wireHigh Purity MGO

View Complete Details

Cast Strip Plate Heater

CAST STRIP HEATERS AND CAST PLATE HEATERS are tubular heaters cast in aluminum or bronze alloy.

Application
  • Extrusion dies
  • Flat machinery parts
  • Sealing applications
  • Platens
Features
  • Contamination proof
  • Rugged construction
  • 10-32 screw terminals
  • 1 thick
  • .440 tubular heater

View Complete Details

Flanged

IHCO FLANGED IMMERSION HEATERS are designed to be attached to flat surfaces of tanks or mating flanges in order to heat liquids. The number of hairpin-shaped elements varies according to wattage and size of flange.

Construction and Features

FLANGE

  • Material and rating- 150 pound Carbon steel (sizes available: 3, 4, 5, 6)
Elements

SHEATH MATERIAL

  • Sizes available: .440, .315

HOUSING

  • Incoloy for immersion in materials corrosive to copper and stainless steel and high heat environments (to1600o F)
  • Stainless Steel for environments corrosive to copper (1200oF)
  • Copper for water heating and Liquids not corrosive to copper (to 350o F)
  • NEMA 1- without thermostat options

TEMPERATURE CONTROL

  • Thermostat option (see previous page)
  • Thermocouple may be spot welded to element sheath

CIRCUITS

  • Single-phase: one or two elements
  • Three-phase: three, six or nine elements
  • Number of elements possible by Flange size:3- 1, 2 or 34- 2, 3, 4 or 65- 2, 3, 4, 6, 8 or 96- 2, 3, 4, 6, 8 or 9
View Complete Details

Ceramic Band Heater

  • Application Chemical Industry
  • Max. Power 7 watts per sq. cm
  • Max. Temperature 250 degree C
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us