Post Buy Requirement

Our Products

  1. Measurement Gauges & Fittings 13 Products available
  2. Valves & Valve Fittings 3 Products available
  3. Measuring Instruments & Equipment 3 Products available
  4. Flow Meters

    2 Products available
  5. Testing Equipment

    2 Products available
  6. Industrial & Engineering Products

    1 Products available
  7. Flanges

    1 Products available
  8. Fire Fighting & Protection

    1 Products available
  9. Process Control Systems & Equipment

    1 Products available
  10. Sensors

    1 Products available
  11. Others Products 9 Products available

Our Products

Leading Manufacturer, Supplier & Retailer of RTDS Simulator, Hand Held (Portable) Digital Temperature Indicator and Flameproof Indicator.

3 Piece Flange End Full Bore Ball Valve

Salient Features

(1) Square body, Gland Type Body and Actuator Mounted pad type body available(2) Investment Castings Body, Side Piece(3) Pneumatic Actuator operated ball valve available on request

Features Material Specifications
Design STD As per BS 5351 1 Body CF8M, CF8, CF3M, CF3, WCB Etc.
Face to Face As per ASME B 16.10 2 Side Piece CF8M, CF8, CF3M, CF3, WCB Etc
Flange End As per ANSI B 16.5 3 Ball SS 316., SS 304, SS 316L, 304L Etc.
Testing STD As per BS 5146, API 5208 4 Seat PTFE, Glass Or Carbon PTFE Etc.
           
   

 

 

 

 

 

  Details of Dimension
 
 
       
 
Class
150 #
 
300 #
 
"E" Table
 
"F" Table
 
   
Size
15
20
25
40
50
65
80
100
150
200
250
300
F/F PCD OD
108 60.5 89
117 70 98.5
127 79.5 108
165 98.5 127
178 120.5 152.5
190 140 178
203 152.5 191
229 190.5 229
267 241.5 279.5
292 298.5 343
330 362 406.5
356 432 482.5
 
F/F PCD OD
140 67 95
152 83 117
165 89 124
191 114 156
216 127 165
241 149 190
283 168 210
305 200 254
403.5 270 317
419.5 330 381
457 387 444
502 451 521
 
F/F PCD OD
108 66.6 95
117 73 101.5
127 82.5 114.5
165 98.5 133.5
178 114.3 152.5
190 127 165
203 146 184
229 177.8 216
 
F/F PCD OD
108 66.6 95
117 73 101.5
127 87.8 120.5
165 104.7 140
178 127 165
190 146 184
203 165 203
229 190.5 229

 

View Complete Details

Flush Bottom Ball Valve

Salient Features

(1) Square body, Gland Type Body and Actuator Mounted pad type body available(2) Investment Castings Body, Side Piece(3) Pneumatic Actuator operated ball valve available on request .

View Complete Details

2 Piece Flange End Full Bore Ball Valve

Salient Features

(1) Investment Castings Body, Side Piece(2) Double Body Sealing

Features Material Specifications
Design STD As per BS 5351 1 Body CF8M, CF8, CF3M, CF3, WCB Etc.
Face to Face As per ASME B 16.10 2 Side Piece CF8M, CF8, CF3M, CF3, WCB Etc
Flange End As per ANSI B 16.5 3 Ball SS 316., SS 304, SS 316L, 304L Etc.
Testing STD As per BS 5146, API 598 4 Seat PTFE, Glass Or Carbon PTFE Etc.

 

 

 

 
 
Details of Dimension
 
 
       
 
 
Class
 
150 #
 
300 #
 
   
Size
15
20
25
40
50
65
80
100
150
200
250
300
 
F/F PCD OD
108 60.5 89
117 70 98.5
127 79.5 108
165 98.5 127
178 120.5 152.5
190 140

178

203 152.5 191
229 190.5 229
267 241.5 279.5
292 298.5 343
330 362 406.5
356 432 482.5
 
F/F PCD OD
140 67 95
152 83 117
165 89 124
191 114 156
216 127 165
241 149 190
283 168 210
305 200 254
403.5 270 317
419.5 330 381
457 387 444
502 451 521

 

View Complete Details

Hydraulic Fittings

Hydraulic ttings are designed for use in Oil hydraulic, pneumatic systems, instrumentation systems in chemical plants, steel processing Industries, fertiliser, petrochemical and petroleum industries requiring high degree of precision and reliabililty. These ttings can be dismantled and reassembled for maintenance without loss of effectiveness of sealing.Fittings are available as standard for CD size metric tubing, Inch series ttings can also be manufactured.

Carbon steel ttings with Cadmium plating can be used in Corrosive application. For very aggressive applications use our Stainless steel ttings in A.S.l. 304 or A.l.S.l. 316, which are made in Single or double ferrule construction.

.

Features:

- Unique three piece design.

- Ferrule takes seat on pipe surface when tightened, thus provides leak proof joint.

- Case hardened ferrule for hard case and soft core for spring action and repeated use.

- Light, Medium and Heavy pressure class.

- Special Manganese based Phoaphatieingtreatment of surfaces for corrosionresistance.

- Cadmium plated ferrule for self lubrication. while assembly.

- Special execution for Galvanised & Cadmiumand Nickel plated nish.

- Metric and Inch series ttings.

- Strict quality check at each stage of manufacture.

- Hydraulic test for compliance for each batch

Assembly Precautions : -

Cut tubes at right angle without any Burr- Deburr tubes at O.D. and l.D. before Sttfhpting assembly.- Lubricate Nut, Ferrule, Tube O.D. and body of fitting with oil.- Slide ferrule over tube end and check it slides freely over the 2" - 3" of the tube length.- Ensure to assemble ferrule correctly and net which shall not give leek tight joint.- Tighten Nut with hand till there is slide time till it reaches step in body.- Tighten Nut fully with spanner 3/4th turn. Ensure to hold tube from rotating.

View Complete Details

Temperature Bath / Calibrator

These rugged temperature calibrator, essentially comprises of a metal block, electrically heated and precisionely controlled, using microprocessor based PID controller. Optionally An additional digital temperature indicator & sensor duly calibrated & having traceable calibration certificate can also be provided for use as external reference for comparison purpose. Control stability is typically 1C and is directly readable from display eliminating any guess work. However the calibration accuracy is only limited by the accuracy of the standard / reference sensor or thermometer used .

Features : - Temperature range up to 1000C- Fast, stable, accurate & maintenance free- High Immersion length enables calibration of analogue dial type thermometers- Auto tuned PID controller with 5 recipe memory- Heater high / low position selectors switch enables the use on low temperatures also

 

Temperature range 200ËšC to 1100ËšC
Type Electrically heated Dry Block
Resolution 1ËšC or better
Stability ± 0.5ËšC for 10 min
Control Philosophy auto tuned PID controller
Reference Temperature Comparison 6 MM dia hole for controller (Reference sensor & indicator optional
Immersion Depth 175 MM
Heating Time to Max. Aprox. 90 min . max
Stabilizing time Aprox. 45 min
Heating Element Kenthal
Power Supply 220 V AC ± 10% 1.2 KW
Housing M S Powder coated
Mounting Table top
Dimension H 11" X W 10" X L 15"
Weight 8 kg aprox.
Accessory Provided Metal block 60 MM OD  150 MM long having block holes as Follows 2 x 4 MM OD,  2 x 6 MM OD,  2 x 8 MM OD,  2 x 10 MM OD Block hole depth 100MM
Optional Accessories Inconel metal block  Reference Digital Temperature Indicator and sensor
View Complete Details

Dead Weight Testers

Deadweight Testersare used for calibration of Pressure gauges and all other Pressure sensing, transmitting & recording instruments. Variety of economical models to suit the industry needs are available in accuracies of 0.2% to 0.1%.

Applications:Deadweight Testers are used for calibration of pressure gauges and all other Pressure sensing, transmitting and recording instruments having High Accuracy.

Deadweight testers consists of frictionless piston mounted on a rugged base. Its screw type operating system ensures an effortless operation. Rotation of the screw pump produces the pressure which is balanced by precision weighs directly marked in pressure units and stacked on the carrier weight. These testers are designed for precision accuracy of 0.1 % to 0.2%. (Accuracy of 0.01 optional) Unit marking available in Kg/cm2, PSI or Bar etc.

Deadweight Tester is of robust construction with a sturdy steel base having adjustable screws.

Standard Accessories:

  • - Accurately calibrated weight.
  • - Gauge connection Adapters for 1/8", 1/4", 3/8", 1/2" BSP, 1/2" NPT, M20 x 1.5p on 1/2" BSP Fitment.
  • - Pointer Puller and Pointer Punch.
  • - Gauge Opener
  • - Spirit Level.
  • - A set of spanners in a Tool Box.
  • - 500ml. oil (SAE 30/40) bottle.
  • - One set spare seals.
  • - A sturdy carrying case of weights.
  • - Dust cover.
Ranges:The ranges are selectable up to 400 Kg/cm2as tabulated below.

Range in Kg / cm2
Form To In Step of
0.2

10

0.1
0.5 30 0.1
0.6 30 0.2
1.0 100 0.5
2.0 200 0.5
10 400 0.2
View Complete Details

Comparison Testers

Comparison Testersare used in Laboratories with requirements as test bench for calibration of field mounting gauges as per quality procedure of Industries such as Chemical, Petrochemicals, Pharmaceuticals Bulk Drug and Engineering. These rugged bench mounted testers are manufactured in steel construction, are easy to operate and maintenance free.

These machines can be offered in two different material of constructions and three models :

- STAINLESS STEEL 304 WETTED PARTS, WATER AS PRESSURE MEDIA.- ALL STAINLESS STEEL CONSTRUCTION, FOR CORROSIVE ATMOSPHERE. Low pressure class machines are equipped with two feed valves for ease of operation, having Operating Range from 0 to 2000 PSI. Medium pressure class machines are equipped with only one valve having operating Range from 100 PSI to 6000 PSI.

High pressure machines are provided with one valve and with high capacity priming pump for quick filling of system and fast response, having operating range upto 10, 000 PSI.

Pneumatics comparison testers can be use for vacuum to up to 350 PSI. This can also be used to check compound gauges.

Full set of adapters are standard accessories to enable to mount gauges with almost any connection size, right from 1/8" to 1/2" B.S.P. / N.P.T. and M20 x 1.5p. Pointer punch, required spanners and alen keys are part of tool kit so no other tools are required to operate or maintain the machine.

Salient Features: Stainless Steel Construction allows use of water as a hydraulic media, which enables the use of hydraulic comparison tester in industries like Bulk Drugs, Calibration Gases, Oxygen etc. were hi standard of hygiene is required.

View Complete Details

Flame Arrester

The Flame arrester protect storage, distribution and chemical process facilities containing Flammable gasses from fire and explosions. It is an effective device that isolate source of ignition and allows vapour to flow freely in venting and collection system. The most effective method of quenching flame is to install these. Flame arrester either at the strategic point along with pipe work system or at end of pipe line where gas/vapour are being vented into atmosphere.

View Complete Details

Double Window Sight Flow Indicator

Double Window type Sight Flow Indicator provides durable, quick reliable & economical way to verify the flow of liquids through industrial process lines. The round glass window area is large enough to provide better visibility. These are available in single window or double window constructions,

Investment Casted or fabricated body & cover plate & the use of the toughened soda lime glass windows combined with selected seals which fit correctly in to properly machined seats which results in unusually high pressure ratings for double window sight flow indicators. This can also be used on vacuum applications. The glasses can be individually removed & replaced in this design. It's smooth internal passage offers very little registrance to flow These are available in plain models, rotator, flapper, drip tube types. Jacketed type also can be provided for heating & cooling applications. Available sizes 15 MM to 200 MM in all types of flanged & threaded process connections. Toughened borosilicate or Plexi glasses can be supplied optionally. Max. op. Temp. 200C .

Features : * Light weighted investment casting body aliminates the need of heavy pipe support and also reduces stress corrosion.* Blow hole free investment casting body.* Electo polish finish for better registance to sarface corrosion.

Glass Toughened Soda Lime
Body & cover plate WCB / M.S., CF 8 / S.S 304, CF 8M / S.S. 316
Lining (optional) PTFE / TFE / PFA coated for corrosive application
Gaskets PTFE (Standard) / Neoprene - Viton - Silicon (Optional)
Nuts & Bolts CS / ASTM A 194 & 193 / SS
Max. Op. Temp 200°C
Max. Op. Pressure 20 Kg/cm2
Process Connection Flanged as per A.S.A & B.S Standards or Screwed
View Complete Details

Full View Sight Flow Indicator

Full view Sight Flow Indicator is recommended where maximum visibility is desired on low pressure applications ( Upto 8 kg/cm2). It can be used in vertical or horizontal lines with a negligible pressure drop. It is ideal for visual check of the presence, colour & condition of liquid, where there is intermittent flow, partially filled lines or entrained air.

This Sight Flow Indicator is rugged in construction, comprises of havi walled buttress borosilicate glass cylinder placed between two flanges. Teflon gaskets offer superior protection & better sealing.

Available in all types of flanged & threaded process connections. Various material of flanges and linings is available as per applications requirement.

Features : * Blow hole free investment casting body.* Electo polish finish for better registance to sarface corrosion.

Glass tubes

Borosilicate buttress
Nuts-Bolts and stud M.S. / S.S. 304 / S.S.306
Materials of Flanges WCB / M.S., CF 8 / S.S 304, CF 8M / S.S. 316
Flange standards A.S.A #. 150 RF, A.S.A.# 300 RF, B.S. 10 Table E or F
Lining (optional) PTFE / PFA / TFE (0.8 TO 1mm thick)
Sealing PTFE (standard)
Operating temperature 210oC Max. with PTFE sealing
Optional Sealing Material PTFE envelop with Neoprene insert / Viton / Silicon
Flange to Flange distance 100 mm / 125mm / 195 mm (+-3mm)
Hydraulic test pressure for size 15 to 50 mm 8 Kg/cm2 / 65 to 100 mm 5 Kg/cm2 / 150 mm 3 Kg/cm2
View Complete Details

Digital Temperature Controller ( One

Salient Features:


- High Stability and Reliability

- Special Controller for Cooling with time delay

- Trip Controller for safety with manual acknowledge

- Sensor failed Protection .

Display 3 1/2 Digital 7 Segment Red colour 0.5" ht
Cold Junction Compensation Auttomatic For T/C
Sensor Input J, K, R, S, T/C, PT-100 RTD, mV, V & 4-20 mA I/P
Accuracy J, K 1%, R, S, 0.5%, PT-100 RTD 0.2%, mV, V, mA 0.1%
Sensor open Indication By '1' at MSD
Set Point Multiturn Trimpot for each set point.
Hyst Pot 1 to 10 0c for each set point for ON- OFF Model
Tune Pot ±5 °C  for each set point for Time Proporational Model
Control Action ON/ OFF or Time Proporational
Control Output 6 Amp or 20 Amp. 1 c/o Relay, 230 V.A.C., 12 V. DC. pulse o/p for S.S.R., for each set point
Operating Temperature 0-50 °C  (RH < 80%)
Supply 230 V.A.C. ±10% 50 Hz

 

Dimensions (H x W x D) 96 x 96 x 120 mm 72 x 72 x 110mm
Panel Cutout (H x W) 92 x 92mm 68 x 68 mm

 

View Complete Details

Thermowells

Thermowells provide complete protection for the sensor (RTD - Thermocouple or Thermometers).

Thermowell is designed considering application requirements. Thermowell allows removing / replacing of sensor without shutting down the process.

This can be made from materials like SS 304, 316, 304L, 316L, 310, 446, Carbon Steel, Hestalloy.C, Monel. This is also be made of ceramic material like recrystalied Alumina for high temperature application .Coating of various grades of Apcolon Fluero plastics like PTFE, TFE, PVDF & PFA can be supplied as per the process requirements.

Types of Thermowells:

Threaded drilled from bar stock. Drilled Bar Stock with welded flange / Threaded or Flanged Fabricated Thermowells. Thermowells threaded as per API standard or BS pipe threads, flanged as per ANSI, B.S., JIS, DIN standards are available.

View Complete Details

Rtd Thermocouple Sensors

RTD'S are high precision device used to measure temperatures in corrosive and non-corrosive media. They work on the principle of variation of resistance of a sensing element, usually made of Platinum, with corresponding change in temperature.

These RTD's are available in following types:PT100, PT200, PT500, & PT1000 (AS PER DIN 43760 OR BS904 CLASS II) Pt50 (as per JIS) Simplex or Duplex.

THERMOCOUPLE :A thermocouple is a sensor for measuring temperature. It consists of two dissimilar metals, joined together at one end which produce a small unique voltage at a given temperature. This voltage is measured and interpreted by a thermocouple thermometer.

These thermocouples are available in three types of hot junctions : The Grounded Junction :Recommended for the measurement of static or flowing corrosive gas or liquid temperature and for high pressure application. The junctions are welded to the protective sheath giving faster response. An Underground Junction :Used for measurement in corrosive application where it is desirable to have the thermocouple electronically isolated form and shielded by a seath. The junction is physically isolated from the sheath from MgO powder. An Exposed Junction :It is used for the measurement of static or flowing non-corrosive gas temperature where fast response time is required. The junction extends beyond the protective seath to give accurate and fast response. The seath insulation is sealed where the junction extends to prevent penetration or moisture or gas which would cause.

Types of Assemblies available:

Terminal Block Type/ Whether Proof IP 65 Or Flame Proof head mountHand Held Type.Mineral Insulated Metal Sheath.Transition Joint Type.Quick Disconnect.Thermocouple with special outer sheaths like silicon Carbide, PTF, PVDF coated etc.

Mountings:Fixed male threaded, addittion, Gland type, Nipple - Union, Nipple assembly or adjustable flanged types, Bayonet type and others.

Insulations:Multibore ceramic tubing / Magesium Oxide (MgO filled) / M.I.

Ordering informations for Thermocouples and RTDs:Operating Range, RTD/Thermocouple's type & Class - [ K / J / T / E / B / R / S - Simplex or Duplex, ]Specify Wire Gauge in case of Thermocouple, Type of RTD Element & ClassHead Assembly Weatherproof / Ex. Proof, Seath Material - Length & O.D., Extension cable material - It's covering length, Process connection, Wire connection - 2 Wire / 3 Wire / 4 Wire

 


Type          Conductor Callibration RangeËšC Sheath
K CROMEL/ALUMEL IS:2054, DIN 43710 0-1200 SS 446/ SS310 / SS316 / Inconel 600
T COPPER / CONSTANTANN IS:2056, DIN 43710 0-350 SS 340 / 316
J IRON / CONSTANTANN IS:2056, DIN 43710 0-750 SS 316
R Pt 13% Rh - Pt IS:2055, DIN 43710 0-1450 SILLIMINATE
S Pt 10% Rh - Pt IS:2055, DIN 43710 0-1450 SILLIMINATE
B Pt 30% Rh - Pt IS:6720, DIN IEC B8 800-1700 RECRYSTALLISED ALUMINA

View Complete Details

Denvar Make Bimetallic Thermometers

Bimetallic Instruments are housed in Weatherproof IP 55 die cast Aluminium/S.S. 304 case or Pressed steel Non Weatherproof casing and are available in dial size of 25, 40, 50, 63, 100 and 150 mm. These instruments are available in rigid stem type bottom and back connection direct mountings. The hazardous environments generally warrants use of these type of instruments.

Case & Bezel Material Material Die Cast Aluminum / S.S 304.
Window Sheet Glass
Mounting Direct Mounting Bottom / Back entry
Pointer Micro Zero Adj. / Balanced Aluminium.
Dial Aluminium, Black graduation on white background.
Stem Material Brass Chrome Plated. SS 304, SS 316.
Stem Size 8/10/12 & 16mm
Stem Length From 50 mm to 500 mm
Connection 1/4",3/8",1/2" BSP / NPT fixed or Adjustable Gland type.
Range From -20°C to upto +300°C in standard ranges.
Accuracy ± 2% of the span (±1% optional)
Overrange Protection 20% of the span.
View Complete Details

Condensate Trape

Features

- Use as Liquid or Condensate trape, Seal Pots, Vapour Chember & knockout port- Chembers are made from seamless pipes & weld caps.- Welding as per ASME SCE IX- Radograph / D.P. Test can be offered.- Hydro Tested for 1.5 times the working pressure

 

Matterial of  construction Schdule 40 Test Pressure Schdule 80 Test Pressure Schdule 160 Test Pressure
A 106 Gr.B 80 Kg / cm2 125 Kg / cm2 210 Kg / cm2
SS 304 / SS 316

95 Kg / cm2

150 Kg / cm2 ----------------
           
             
 
 
View Complete Details

Flame Proof Temperature Indicator

We manufacture of flame proof temperature indicator .Our domain expertise and ability to render world-class quality products coupled with reliable and efficient customer services are responsible for our step-by-step growth and provide a cutting-edge in this market arena.Display 3 1/2 digit 7 segment Red LED 0.5" htCold Junction Compensation Automatic For T/CSensor Input J, K, R, S T/C, PT-100 RTD, mV, V& 4-20m AAccuracy J, K 1 % R, S 0.5%, PT-100 RTD 0.2%, mV, V, mA, 0.1%Sensor open Indication By '1' at MSDSupply 200 V.AC. + 10% 50 HzEnclosure Gas group I, IIA, IIB as per IS-2148 / 2147/ IP - 55
View Complete Details
Tell Us What are you looking for? Will call you back