Our Products
eatures: |
The design of wire and plate grid, lends itself to various advantages over conventional cast iron grids and standard wire wound resistor assemblies. In the assembly design breakable parts are excluded, resulting in robust construction. In the wire grid assemblies, the unique terminal arrangement, facilities easy replacement of individuals grid. |
The assembly can tailor designed and is available in stack and panel mounting versions. This is ideal for compact design of special purpose control panels. The panel mounting versions has an added advantages of saving in interconnection and wiring. |
Material :Standard-stainless steel, other alloys request. |
Applications :Load Banks, Rotor Starters, Crane Controllers, Motor starting and braking resistors. |
Type | Resistance Ω±10% | Continuous Current Rating |
PGS 7 H | 0.0075 | 220 |
PGS 12 | 0.012 | 180 |
PGS 15 | 0.015 | 160 |
PGS 22 | 0.022 | 125 |
PGS 32 | 0.031 | 105 |
PGS 45 | 0.043 | 90 |
PGS 65 | 0.065 | 65 |
PGS 80 | 0.080 | 53 |
PGS 100 | 0.100 | 49 |
PGS 200 | 0.200 | 37 |
Type | Resistance Ω±10% | Continuous Current Rating |
WGS 18 | 0.018 | 121 |
WGS 25 | 0.025 | 106 |
WGS 35 | 0.035 | 92 |
WGS 50 | 0.050 | 80 |
WGS 80 | 0.080 | 62 |
WGS 100 | 0.100 | 55 |
WGS 150 | 0.150 | 45 |
WGS 250 | 0.250 | 37 |
WGS 370 | 0.370 | 27 |
WGS 56 | 0.560 | 20 |
WGS 750 | 0.750 | 14 |
WGS 1000 | 1.000 | 14 |
WGS 2000 | 2.000 | 11 |
Discharge Test : Periodical discharge test on station batteries is a mandatory requirement for users. These tests ensure reliability, better service and enhance life performance of the battery system. Battery manufacturers specify Yearly / Half Yearly / Quarterly Charge / Discharge cycle tests. |
Advantages : Discharge cycle tests help the users to : |
|
Discharge Resistor : Our unit is designed to perform periodic discharge tests on station batteries. The resistor unit is a robust assembly consisting of Copper-Nickel Alloy wire grid elements, supported on S.S. tie rods, insulated from each other and the enclosure with Micanite tubes, washes and ceramic formers. The unique design of elements allows rapid, natural cooling of resistor bank. Castors are provided for easy mobility. |
Constant Current and Rate of Discharge : The resistor bank has adequate trimming facility (coarse and fine) to maintain a constant current against falling voltage during discharge operation. D.C. contractors / Circuit breakers or knife edge sitches are used for switching depending on clients preference. The Rate of Discharge can be accurately controlled and monitored in this system which is a distinct advantage over other conventional methods of Discharge. |
Our Clients for Discharge units : |
|
STANDARD CONSTRUCTION |
High grade ceramic former.Copper nickel and Nickel chromium alloy wires and tapes used for winding.Self lubricating alloyed silver contact adjusted for optimum contact pressure.Creepage proof design.High grade silicon cement insulation. |
CUSTOM VARIATIONS Graded and/or tapped windings.Gang assemblies up to four units.Special shaft lengths.Off positions at either end of winding.Knobs, dials and locking arrangement |
Wattage | Former Type | Length mm | OD mm | ID mm |
60 | S5H | 139.7 | 22.0 | 12.7 |
63 | K125 | 125.0 | 23.0 | 15.0 |
74 | S6H | 165.1 | 22.0 | 12.7 |
120 | T6H | 165.1 | 31.0 | 19.0 |
150 | T8 | 203.2 | 31.0 | 19.0 |
200 | T10 | 254.0 | 31.0 | 19.0 |
230 | T12 | 305.0 | 31.0 | 19.0 |
350 | U10 | 254.0 | 53.0 | 38.1 |
500 | U14 | 355.6 | 53.0 | 38.1 |
Opportunities with BV |
Products and Technology from BV backed by the trust and credential IRESCO enjoys in Indian Industries would provide the perfect combination for the business of cold plates, LBB and cliplams. |
Cold plate used by BHEL |
Qty expected - 900 nos. |