Post Buy Requirement

Laboratory Apparatus

Our product range contains a wide range of Oxidation Induction Test Apparatus, Computerised VSP HDT Apparatus and E.S.C.R Apparatus

Oxidation Induction Test Apparatus

Specification:
Temperature Controller:Digital PID Controller with range up to 300C, Resolution
of 0.1C & accuracy of +0.5C.
Pan:500 Nos. of aluminium pans with 40 mesh screen in SS 316 will be provided as per DOT specification.
Gas Flow Control:Gas Regulators & Rotometers will be supplied for Nitrogen & Oxygen Gas respectively.
Indium material will be supplied for Calibration of temperature.

PRINTOUTS THROUGH PC:

The display & printout of Delta Temperature Vs Time graph along with Oxidation Induction Time result is Possible through your PC. The printout includes Partys Name, address, file name, date, batch no, Operator name, Sample weight, Set temperature, Start time, Finish time, Gas flow rate etc.
Calibration graph of melting point of indium metal along with printout facility is provided as per DOT Specification.
Cooling System: Cooling of barrel by water is provided.

View Complete Details

Computerised VSP HDT Apparatus

as per ASTM D 1525 and ASTM D - 648 to determine vicat softening temperature and heatdeflection temperature of plastics.
Specification:

Temperature range :From ambient to 300C.
No of stations :Three.
Material of construction :Inner bath: S.SOuter body: M.S
Rate of heating :120C / hour and 50C / hour.
Sensor :Range upto 10mm with resolution of 0.01mm.
Weights :A set of weights ranging from 5grams to 2000grams would be supplied for incrementalloads.
Paint :Powder coated.
Power :230 Volts, 50Hz, single phase.

Graphic display and printout through PC:Penetration/Deflection Vs Temperature graph and numeric reports consisting values of vicat softening temperature and heat deflection temperature could be obtained by attaching a printer to the PC.

View Complete Details

E.S.C.R Apparatus

as per astm d - 1693 to determineenvironmental stress cracking of ethylene plastics.

specification:

temperature range :from ambient to 200c.
no. Of stations :six.
material of construction :inner bath: s.souter body: m.s
accessories :cutting die, nicking jig, bending cum transfer tool and aluminium foil 1no.each, specimen holder, test tube and rubber cork 6 nos. Each.
paint :powder coated.
power :230volts, 50hz, single phase.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Laboratory Apparatus from Mumbai, Maharashtra by International Equipments
Post Buy Requirement

Laboratory Apparatus

Our Complete range of products are Oxidation Induction Test Apparatus, Computerised VSP HDT Apparatus and E.S.C.R Apparatus.

Oxidation Induction Test Apparatus

Specification:
Temperature Controller:Digital PID Controller with range up to 300C, Resolution
of 0.1C & accuracy of +0.5C.
Pan:500 Nos. of aluminium pans with 40 mesh screen in SS 316 will be provided as per DOT specification.
Gas Flow Control:Gas Regulators & Rotometers will be supplied for Nitrogen & Oxygen Gas respectively.
Indium material will be supplied for Calibration of temperature.

PRINTOUTS THROUGH PC:

The display & printout of Delta Temperature Vs Time graph along with Oxidation Induction Time result is Possible through your PC. The printout includes Partys Name, address, file name, date, batch no, Operator name, Sample weight, Set temperature, Start time, Finish time, Gas flow rate etc.
Calibration graph of melting point of indium metal along with printout facility is provided as per DOT Specification.
Cooling System: Cooling of barrel by water is provided.

View Complete Details

Computerised VSP HDT Apparatus

as per ASTM D 1525 and ASTM D - 648 to determine vicat softening temperature and heatdeflection temperature of plastics.
Specification:

Temperature range :From ambient to 300C.
No of stations :Three.
Material of construction :Inner bath: S.SOuter body: M.S
Rate of heating :120C / hour and 50C / hour.
Sensor :Range upto 10mm with resolution of 0.01mm.
Weights :A set of weights ranging from 5grams to 2000grams would be supplied for incrementalloads.
Paint :Powder coated.
Power :230 Volts, 50Hz, single phase.

Graphic display and printout through PC:Penetration/Deflection Vs Temperature graph and numeric reports consisting values of vicat softening temperature and heat deflection temperature could be obtained by attaching a printer to the PC.

View Complete Details

E.S.C.R Apparatus

as per astm d - 1693 to determineenvironmental stress cracking of ethylene plastics.

specification:

temperature range :from ambient to 200c.
no. Of stations :six.
material of construction :inner bath: s.souter body: m.s
accessories :cutting die, nicking jig, bending cum transfer tool and aluminium foil 1no.each, specimen holder, test tube and rubber cork 6 nos. Each.
paint :powder coated.
power :230volts, 50hz, single phase.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us