Post Buy Requirement
IA

INTECH ANALYTICAL INSTRUMENTS

Verified Add Review

Our Products

We offer a complete product range of Glass Columns (BPGC) Low Pressure, Analytical Protein Purification Chromatography, Inline Conditioning Buffer System (ILCB), Auto Glass Column (AXI Column) Protein Purification and low pressure chromatography skid production scale

Glass Columns (BPGC) Low Pressure

  • Country of Origin India

1. Config ID: MCC 70/ 100/ 140/ 200/ 300/ 400/ 450mm.2. Column Height: 500/ 750/ 950mm3. Max. Working Pressure: 70/ 100 (7 bar), 140 (6 bar); 200 (5 bar) 300/ 400/ 450 (3 bar)4. Operation Mode: Manual5. Mesh Size: 10/ 23(PP) & 10/ 23 (SS 316L)

6. Working Temperature: 4 - 40 C.

View Complete Details

Protein Purification/ Low Pressure Chromatography LPLC

  • Country of Origin India
  • Brand Name Hanbon
  • Warranty 1 Year

1. Config: 50/ 100/ 300ml/ min.2. Detector: UV- Visible (Adjustable path length/ volume).3. Flow Accuracy: 0.5%.4. Fraction: Automatic.5. Software: Bio-Lab (21 CFR Part 11 Compliance).6. Liquid Contact: PTFE/ SS 316L/ Acrylic.7. pH : 0 - 14.8. Conductivity : 1 - 500000 us/ cm.

9. Optical Path Length: 1/ 2/ 3/ 5/ 10mm.

View Complete Details

Inline Conditioning Buffer System (ILCB)

  • Certification CE Certified
  • Warranty 1year
  • Country of Origin India
  • Brand Name Hanbon

1. Config: 180/ 600/ 1200/ 5000/ 9000 L/ Hr.2. Detector: UV- Visible (Adjustable path length/ volume).3. Flow Accuracy: 1 %4. System Pressure: 6 bar.5. Software: Easychrom(21 CFR Part 11 Compliance)6. Conductivity: 1 ms/ cm - 500 ms/ cm

7. pH : 0 - 14

View Complete Details

Auto Glass Column (AXI Column) Protein Purification

  • Country of Origin India

1. Config ID: ACC 400/ 450/ 600/ 800/ 1000/ 1200/ 1600/ 2000 mm.

2. Column Height: 600 mm3. Max. Working Pressure: 4 bar4. Operation Mode: Automatic - Electric Motor Axial Compression5. Frit Port Size: 10/ 20 micron (SS 316L)6. Compressed Air: 5 - 7 bar7. Working Temperature: 4 - 40 C.

View Complete Details

Protein Purification/ Low Pressure Chromatography Skid Production Scale

  • Country of Origin India

1. Config: 60/ 180/ 600/ 1200/ 4400 L/ Hr.

2. Detector: UV- Visible (Adjustable path length/ volume).3. Flow Accuracy: 1 L/ Hr ( 1 %), 180/ 600/ 1200/ 4400 L/ Hr ( 2 %)4. System Pressure: 6 bar.5. Fraction: Auto/ Manual6. Software: Easychrom(21 CFR Part 11 Compliance)7. Conductivity: 1 ms/ cm - 500 ms/ cm8. pH : 0 - 14

View Complete Details

ATEX Preparative HPLC System

1 Cr - 2 Cr /rupees Get Latest Price
  • Size Varies
  • Type Hplc System
  • Weight 1 ton -30 ton
  • Pressure Range 10 MPa
  • Country of Origin India

ATEX Commercial Scale Preparative series Liquid Phase Chromatographic separation and purification system includes larger DAC column and Prep HPLC System. CS- Prep HPLC system mainly includes Infusion pumps, Positive Pressure Explosion -proof Electrical Cabinet, Slurry mixing, Detection, and Injection, Fraction collection, Control and Data processing system

Because of Diaphragm pump has a higher resistance, so it is widely used in many countries. Hanbon can customize different CS Prep Liquid Phase Chromatographic Separation and Purification System from CS Prep 150 2000mm.Also we can provide the Preparative HPLC system that has a Plunger Piston technology with excellent quality and reasonable price with flow rate of 10, 20, 40, 80, and 120L/min High Pressure Plunger Piston Pumps.

With the evolving needs of the industry for enhanced productivity at lower cost of production, Hanbon offers a comprehensive of chromatography based purification solutions. The ATEX Prep HPLC mainly includes a diaphragm type pump for the slurry transfer as well as required valves for easy packing/Unpacking operations. The control panel displays the different flow paths for column, packing unpacking operations

  • Industrial PLC equipped with PC interface and Real- time monitoring of all process parameters
  • Validated software based on GAMP 5 or Clarity and compliant with 21 CFR parts 11 and same software from lab to industrial scale for seamless scale- up.
  • Technical training, discussion and local services

System Range Adaptive DAC
CS – Prep –L ATEX Diaphragm Piston Pump System 0 ~180 DAC200/300
CS – Prep –S ATEX Diaphragm Piston Pump System 40 ~ 300 DAC200/300
CS – Prep –M ATEX Diaphragm Piston Pump System 40 ~ 1000 DAC450/500/600
CS – Prep –L ATEX Diaphragm Piston Pump System 100 ~ 3000 DAC800/1000
View Complete Details

Simulated Moving Bed

50 Lakh - 2 Cr /1 unit Get Latest Price
  • Country of Origin India
  • Brand Name Hanbon
  • Material Stainless Steel
  • Warranty 1 Year
  • Foldable No

Hanbon has developed SMB system and it has been approved by Jiangsu Provincial Science and Technology Department in 2005, our company has been putting more efforts to realize the industrialization of scientific achievement and applied for Nine patents for SMB

In 2006 Hanbon Chromatographic Instrument Development and Industrial project have been listed to the torch- plan project of Jiangsu Provincial government. Pharmaceutical preparation and purification instrument have obtained the National Science and Technology Innovation Fund.

In November 2007, our company applied for "biological, pharmaceutical SMB chromatogram separation and purification equipment and development of industrialization project has been included into the transformation of scientific and technological achievements in Jiangsu province" special fund project major and special projects (Class A). Patent superiority

Column chromatography method is intermittent, SMB chromatogram introduced to improve the level of automation, production efficiency and production environment, realizing the great improvement of cleaning production. The patent technology

Compared to traditional batch chromatography this process leads to higher yields of purified substances while consuming less eluent and packing material.

View Complete Details

Preparative HPLC System

15 Lakh - 10 Cr /Piece Get Latest Price
  • Min. Order (MOQ) 1 Pack(s)
  • Country of Origin India
  • Size 50ml - 10000l/j
  • Product Prep hplc

the main aim of the preparative hplc is to isolate the maximum amount of a certain product at a desired purity in a minimum of time. its purification ranges from milligrams up to grams.

it can solve semi preparative and other small scale products purifications. the loading sample volumes can be reached to grams to meet laboratory needs and research. flexible system configuration can be used for the pumps ranges from 50ml 300ml flow rate is 50mm 100mm dynamic axial compression.

the pilot scale pump flow rate ranges from 300ml 1000ml and the dynamic axial compression columns portable for this flow rates is under100 150mm id.

it can realize the high pressure gradient operation and can also equip with one unit of the preparative sampling pump to satisfy with large volume in demand. all glp can accumulate the number of stroke of plunger piston. the commercial scale system is suitable for running under large flow ranges from 1000ml 5000ml and the portable columns were under 150mm 2000mm dac.

floating piston design can guarantee working life of the high pressure obstructing ring, electronically damper control can effectively control flow pulsation to guarantee the lowest baseline noise.

NAME DESCRIPTION DESCRIPTION DESCRIPTION
Pumps Flow range 50 to 300ml 300 to 1000ml 1000 to 5000ml
Detector NU 3000C UV Visible NU 3000C UV Visible NU 3000C UV Visible
Flow Cell Flow Cell Flow Cell Flow Cell
Mixer Dynamic Mixer Dynamic Mixer Dynamic Mixer
Injection Valve INJ P Prep INJ P Prep INJ P Prep
Loop Hanbon 20ml Hanbon 20ml Hanbon 20ml
Software Clarity & EasyChrom 1000 Clarity & EasyChrom 1000 Clarity & EasyChrom 1000

 
Name Description Description Description
Column Diameter 50 to 100mm 100 to 150mm 150to 2000mm
Column Length 650 650 650to 1300mm
Column inner wall roughness ≤ 0.1µm ≤ 0.1µm ≤ 0.1µm to ≤ 02µm
The effective packing height ≤ 450mm ≤ 450mm ≤ 450mm to ≤ 800mm
Column Design Pressure ≤25Mpa ≤25Mpa ≤20Mpa to ≤10Mpa
Hydro – cylinder design pressure ≤30Mpa ≤30Mpa ≤30Mpa to ≤35Mpa
Normal system pressure ≤20Mpa ≤20Mpa ≤15Mpa to ≤7Mpa
Column end cap connection type Quick Chain Clamp Locking Quick Chain Clamp Locking Clarity & EasyChrom 1000
Wetted material SUS316L SUS316L SUS316L
The rack Material SUS304 SUS304 SUS304
The Packing Method Down Packing Down Packing Down Packing

 

View Complete Details

Hanbon Dynamic Axial Compression Column

  • Min. Order (MOQ) 1 Piece
  • Size 50-2000mm

1. Config ID: 50/ 80/ 100/ 150/ 200/ 300/ 450/ 600/ 800/1000/ 1200/ 1600/ 2000 mm.

2. Packing Type: Down Packing.
3. Pressure: Continuous Air Supply.
4. Filters: Sintered Mesh 2/ 5 micron.
5. Liquid Contact: PTFE/ SS 316 L.
6. Frit Locking: Chain Locking.
7. Safety: Auto pressure cutoff.

Name Description
Column Diameter 50mm to 1200mm
Column Length 650mm to 1300
Column inner wall roughness ≤0.1µm to ≤0.2µm
The Effective Packing Height ≤450mm to ≤ 800mm
Column Design Pressure ≤10Mpa to ≤ 20Mpa
Hydro-cylinder design pressure ≤35Mpa
Column End Cap Connection Type Quick Chain; Clamp locking
Wetted Material SUS316L;PTFE;PEEK;TEFLON
Hydro-cylinder Material 45#Qualitative Carbon Steel
The Rack Material SUS304
The Packing Method Down Packing
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us