The electromagnetic flow meter accurately measures the flow rate of any conducting liquid or slurry that is flowing in closed pipes. It is obstruction less and hence offers no pressure drop in the process. Absence of moving parts ensures that there is no need for maintenance. The performance of the instrument is not affected by the properties of the material such as corrosiveness, viscosity, density, acidity and alkalinity. It can measure the flow of liquids, pastes and slurries in water wastewater. Suitable for chemical, fertilizer, paper, dairy, sugar, food and beverage industries.Wide range of measurement technologies along with all the options to fully customize. Process instrumentation offers the right flowmeter for every application. High-precision metering. Flexible devices. Maximum versatility. World wide service.
AMR/GPRS Meters- A technology which automatically collects metering data and transfers that data to a central database for analysis, History and Record purposes. Detailed water usage data can be collected continuously at regular intervals and can be read remotely via an automated process, with the usage data sent to the utility’s management and uniform water distribution & analysis.
Specifications
Line Size | 15 NB to 600 NB |
---|---|
Connection | Flanged to ASA/BS/DIN/JIS |
Power Supply | 220 VAC/24VDC |
Accuracy | ± 0.5% of FSD |
Minimum Conductivity | 5 µs/cm |
Lining | PTFE, EPDM, Rubber |
Process temperature | Up to 80°C for Rubber, Up to 150°C for PTFE |
Electrodes | SS 316,Hastalloy C, Titanium, Monel, Pt-Rh |
Protection | IP66 / Ex-Proof; Optional: IP 68 |
Specially designed flow coils generate a magnetic field in the flow tube. As the conductive fluid moves in this field, voltage proportional to the velocity of fluid is generated in the electrodes. This voltage is received by the flow converter, and digital signal processing is done before the flow value is displayed. The flow meter uses advanced digital technology with intelligent software systems combined with precision engineering ensuring accurate and reliable flow measurement.
Specifications
Salient Features
Demanded in
Specifications
Pipe Size | Pipe Size | Max Flow | Nom. Flow | Min. Flow | Cut Off |
---|---|---|---|---|---|
10 m/s | 5 m/s | 0.3 m/s | 0.04 m/s | ||
Inch | mm | LPS | LPS | LPS | LPS |
1 | 25 | 5.09 | 2.50 | 0.15 | 0.02 |
1 1/4 | 32 | 8.00 | 4.00 | 0.25 | 0.03 |
1 1/2 | 40 | 12.00 | 6.00 | 0.41 | 0.05 |
2 | 50 | 19.80 | 10.00 | 0.58 | 0.08 |
2 1/2 | 65 | 33.18 | 16.00 | 1.00 | 0.13 |
3 | 80 | 43.61 | 22.00 | 1.50 | 0.20 |
4 | 100 | 75.10 | 38.00 | 2.41 | 0.33 |
5 | 125 | 125.00 | 63.00 | 3.66 | 0.50 |
6 | 150 | 170.43 | 85.00 | 5.50 | 0.69 |
8 | 200 | 295.11 | 147.00 | 9.70 | 1.38 |
10 | 250 | 465.18 | 232.00 | 15.20 | 2.08 |
12 | 300 | 667.18 | 333.00 | 22.00 | 2.77 |
14 | 350 | 798.18 | 399.00 | 23.95 | 3.20 |
16 | 400 | 1166.00 | 583.00 | 38.00 | 5.55 |
18 | 450 | 1500.00 | 750.00 | 50.00 | 7.00 |
Details
Accuracy | ± 0.5% |
---|---|
Operating range | 0.3 - 10 m/s |
Flange | ANSI B 16.5 |
Lining | PTFE/HR/PU |
Minimum Conductivity | 10µS/cm |
Electrodes | SS/Hastelloy C |
Empty Pipe Detection | Yes |
Communication | RS 232 |