Our Products
Calibrators And Monitoring Systems
2 Products availableMeasuring Instruments
2 Products availableFlowmeters And Thermometers
2 Products availableMeasuring Instruments & Equipment
2 Products availableTemperature Sensors
1 Products availableWe offer the best product range of Scientific Equipments.
Features
Temperature controllers are designed to perform the function of keeping an object or process at a desired temperature. In every application where controlling a temperature is required, a controller is used to set a temperature by way of a set point.
ApplicationIdeal for all types of Process Industry
Digital Temperature Indicator are available in Panel mounted model in various sizes. With Universal input they are mostly compatible with any input sensor for accurate temperature measurement.
ApplicationIdeal for all types of Process Industry
We offer Liquid Level Controller to automatically start & stop the pump with tank level input from Magnetic Float Switch or Cable Float Switch. Liquid Level Controller provides LED Indication for Power ON, Relay ON (Motor ON), Tank High & Tank Low.
Features
Miniature Level Switch is a compact construction, suitable for mounting vertically. Miniature Level Switch consists of a Reed Switch housed inside the guide tube & a permanent magnet inside the Float assembly. The Float moving with the liquid level makes (NC) & breaks (NO) the Reed Switch contact. Miniature Level Switch is used for sensing low, high or both high & low level in tanks.
Applications
We are dealers for Full Bore Electromagnetic Flow Meter in process control instrumentation Maintenance free low cost, highly stable reliable & ideal flow meter suitable for wide ranges of liquid flow measurements the flow meter with low pressure. The measurement being based on ‘Faraday’s law of electromagnetic induction’ is independent of viscosity, density, pressure and temperature of the flowing media & measurement is a true volumetric flow measurement. Standard current output of 4 – 20 mA DC is provided which is directly proportional to the instantaneous volumetric flow rate.
Full Bore Electromagnetic Flow Meter can be used for precise flow measurement of all electrically conductive liquids such as sledges, slurries, sewage, milk, water and waste water.
Applications
Dimensions
The bi-metallic element consists of two strips of different metals, with different thermal expansion coefficients, inseparably joined together. This strip is spirally or helically wound with one end fixed to the body of the thermometer, and the other attached to the axis of a pointer. The Bimetal element directly drives pointer, eliminating gears and linkage. Temperature variation influences the bi-metallic strip such as to rotate the pointer; this rotation is indicated on a dial.
ApplicationsChemicals, Refinery, Fertilizer, Cold Storages, Food, Beverages, Pulp Paper.
Float Level Transmitters are ideal for continuous Level monitoring in Water, Diesel, Chemical and Oils for accurate level Measurement. The Output is not affected by liquid type, temperature, Pressure and other physical parameters. The Transmitter is factory calibrated and is ready to use.
ConstructionFloat Level Transmitter consists of non magnetic sealed stem containing series of reed switches and resistor, Float carrying magnet, Mounting adaptor (or flange) and enclosure containing electronics.
Consider our Float Level Transmitters for all your continuous liquidlevel monitoring needs like Water, Diesel, Lube oils, Fuels, Chemicals and Petrochemical liquids.
Here are just few areas where transmitter can be used.
Technical Specification
Overall Length | 300 mm to 5000mm |
---|---|
Measuring Error | ±0.25 % or Span |
Output Temperature Co-efficient | ±0.007% / oC |
Resolution | 5mm / 10mm |
Ambient Temperature | -40oC to 60oC |
Liquid Temp. Range | -40oC to 120oC |
Liquid Min. Density | 0.8 gm/cc |
Max. Pressure | 10 kg/cm2 |
Protection category | Weather proof Ip66 to IS : 2147 (or) Flame Proof Gr. IIA & IIB to IS : 2148 |
Terminals | Max. 1.5mm2 Flexible |
Cable Entry | PG11 for weather Proof ¾" Et for Flame proof (Glands not supplied) |
Output | 2 wire, 4-20 mA 3 wire, 0-10 V DC RS 485 |
Process Connection | Threaded Flanged Tri clamp Others |
Excitation Voltage | 10-30 V DC |
Loop Resistance | Max. 1200 Ohms |
“Capacitance Level Transmitter is used in sensing level of liquids. Capacitance Level Transmitter can be used for conductive as well as nonconductive liquids. It is offered with PTFE sleeve for better insulation & to withstand high temperature in conductive tanks the insulated probe acts as one electrode & the tank wall as another electrode, any change in liquid level the dielectric value will change thereby changing the capacitance value proportional to the liquid level. In case of nonconductive tanks, a reference probe is provided as ground electrode.
Highlights
Technical Specification
Type | 2 Wire (Loop powered), 3 wire (isolated), 4 wire (Isolated) 4-20 mA 0-10 V DC |
---|---|
Input | 24V Dc |
Permissible Load | 500Ω |
Measuring Rage | 200 mm to 3000 mm in Rigid Probe Upto 15000 mm in Flexile Probe |
Pressure Max. | 5kg /cm2 |
Temperature | -25 to 100oC |
Enclosure | Die Cast aluminium, Weatherproof or Flameproof |
Resolution | 5mm |
Accuracy | +0.5 % Fs |
Mounting | Threaded -½" / 1" / 2" bspm or Npt Flange - 1" /2" Asa/Ansi/Jis/din |
Mounting | SS 304 or SS 316 |
Simple & cost-effective for direct indication of liquid levels in bulk storage tanks under low pressure & temperature. As the liquid level rises, a large dia float moves up with the change in liquid level in the tank. The float is attached to a multi strand wire rope, which passes through 2 nos. friction less specially designed pulleys. The Pulleys in turn are connected to a pointer, which moves on a graduated scale by the side of the tank.
Special Features
ApplicationsWater, Veg oil, LSHS, Molasses, Caustics, Brine, H2SO4 etc. Vapour sealed for Solvent, HCL, and NH4OH etc
Model LV36 Hydrostatic liquid level transducers and transmitters with flush diaphragm is designed for a wide variety of level measurement applications. This model pressure sensor and is protected by the stainless steel (SS) housing. Featuring the flush diaphragm makes the LV36 suitable to measure viscous media or media with small particles, so as to have diverse measurement applications.The standard reference pressure is gauge (or relative) pressure realized through a vent tube in the cable. The reference pressure can also be absolute pressure on request.The measuring range of LV36 transmitters spans from 01 to 0200 meter water column (mH2O) withmeasuring accuracy of 0.5%fs (fs = full scale). The output signal of transmitters can be configured toeither current loop (420mA, standard), voltage output (0.54.5V, 15V), or digital output (I2C orSPI). The millivolt signal directly from the Wheatstone ridge circuit is also available on request(transducer version).
Features
Technical Specification
Parameters | Units | Specifications | |
---|---|---|---|
Measuring Media | Viscous Fluid, Or Fluid With Particles Which Is Compatible With 316l Ss | ||
Measuring Ranges* | Mh2o | 1m, 2m, 3m, 5m, 6m, 8m, 10m, 12m, 15m | |
Overload | %fs | 150 | |
Output Signal | For Transmitters For Transducers |
Mv/V | 4~20ma (standard). ≥ 15 |
Power Supply | For Transmitters | Vdc | 24 (typical), 12, ..., 36 |
Excitation | For Transducers | Vdc Ma |
5, ..., 10 0.5, ..., 2 |
Accuracy | %fs | ≤ ±0.5 | |
Response Time | %fs/year | ≤ ±0.2 (standard), ≤ ±0.1 Is Available On Request | |
Long-Term Stability | Ms | < 1 (10%~90% Of Leading Edge) | |
Input Resistance | For Transducers | Ω | 2000~8000 |
Output Resistance | For Transducers | Ω | 3500~6000 |
Insulation Resistance | Mω @500Vdc | > 500 (transducer Only) | |
Storage Temperature Range | °C | -40~+100 | |
Operating Temperature Range | °C | -20~+85s | |
Compensated Temperature Range | °C | 0~70 | |
Temperature Coefficient Of Span | %fso/°C | ≤ ±0.02 | |
Temperature Coefficient Of Zero | %fso/°C | ≤ ±0.02 | |
Process Connection | Submersible In | ||
Electrical Connection | Φ7.3mm, 4-Core Shielded Black Pvc Cable With/Without A Vent Tube | ||
Membrane Material | 316l Ss | ||
Housing Material | 316 Ss | ||
Environment Protection | Ip Rating | Ip68 | |
Weight (without Cable) | Gram | ~250 |
Ultrasonic Level Transmitter works on the principle of calculation of time interval between emission and receipt of High Frequency sound wave. A high frequency sound wave emitted from a transmitter mounted inside a transducer hits the liquid surface, the time taken by the sound wave to return to receiver mounted inside the transducer will be proportional to liquid level”
Highlights
Technical Specification
Electronics Housing | Stainless Steel or die cast aluminium, flame proof |
---|---|
Temperature | 0 to 65 deg C |
Applications | Liquids including hazardous but non-corrosive medium |
Input Supply | 24V DC |
Analog output (Programmable) | 4 – 20mA 20 – 4 mA 0 – 10 V DC 10 – 0 V DC |
Mode | Distance OR height measurement |
“ Display ” | 8 x 2 alphanumeric displya, “ 7 segment LED ” |
Communcation | RS 485 – Modbus |
Measuring range | 5mtr, 10mtr 0.5mtr, 1 mtr, 3.5 mtr |
Resolution | 1mm, 5mm or 10mm depending on models |
Accuracy | 0.5% of FSD |
Updation time | 150 mS max |
Minimum distance | 40mm to 300mm depending on range |
Display Filter | None / Low / Medium / High |
Temperature compensation | Inbuilt |
Voltage Variations | Internal calibration and automatic compensation |
Process connections | ½” BSP, 1 ½” BSP |
Electrical connections | PG 9 one gland, 2 numbers |
Sensor face | Anodised aluminium |
Sensor body | PVC |
Miniature Head Mount Two wire Temperature Transmitter Model LTX-3000-H, which accepts (Pt-100) or thermocouple or variable resistance signal as the input and provides dc current output of (4-20) mA proportional to mV or resistance values. These transmitters are extensively used to minimize the effect of electrical noise and to eliminate the need of long runs of special compensating and three wire cables since ordinary pair of copper wires can easily be used to transmit the measured temperature without the drop or loss of signal.
Features
Applications
The traditional method for measuring the flow of air blown up through a grain heap. Suited to under-floor systems and blowing fans, the meter is used to confirm that there is adequate flow of air emitting from the surface of the grain. Ventilated grain ensures that the moisture content of the stored grain is kept within a safe limit by the steady flow of air through the grain. The INDUS Crop Airflow Meter for grain is an essential instrument for the successful storage of grain in bulk where under-floor blowing systems are in use.
Principle of operationA lightweight float, made from a thin aluminium disc, moves up and down a tapered transparent tube. A wire running through the centre holds the float in place. The float has been designed to spin, removing possible errors by reducing friction. Air passing up the tube supports the float at a height where its weight is balanced by the pressure drop of the air. A scale on front side gives the flow rate in ft/min. On the opposite side of the tube is a white strip to aid reading the flow rate.
Introducing the Model CIE-305 Digital Thermometer, a portable hand held and compact digital thermometer designed to use an external K type thermocouple as a temperature sensor.
ApplicationsAll Type of Food & Beverages Industries, Cooling Plants, Hot Rolling mills, Tea Gardens, Testing & Calibration. Operating Instruction manual provided along with the Instrument.
Technical Specification
Electrical | |
Temperature Scale | Celsius or Fahrenheit, selected by user. |
Measurement Range | -50°C to 1300°C (-58°F to 2000°F). |
Resolution | 1°C or F, 0.1°C or 0.1°F. |
General | |
Display | 3 1/2 digit liquid crystal display (LCD) with maximum reading of 1999. |
Battery | Standard (9V battery (NEDA 1604, IEC 6F22). |
Dimensions | 147 mm (H) ( 70mm (W) ( 39mm (D) |
Weight | 7.4 0z (210g). |
Simple & cost-effective for visual indication of clean liquid levels at low pressure & temperature conditions. The gauge is mounted parallel to tank so as to form a close loop causing tank liquid to seek its level in the gauge. Guards are provided in the form of tie-rods / C-channels around the gauge to protect it from accidental blows. End blocks have build isolating valve, drain valve & vent plug.
Key Features
ApplicationMedium Storage & Process Tanks, Hydraulic / Filtration/ Chemical Dosing Systems, Water Treatment and Boiler Drum Level / Ships / Bulk Carriers
Thermocouples are temperature sensors made up of two dissimilar metals which are joined at one end forming a hot junction and the open wire end acting as the cold junction, the hot junction is in contact with the process. When the measuring point i.e. hot junction gets heated there is an EMF produced at the cold junction, due to difference in electron density of the two dissimilar metals and the temperature difference between cold end and hot end.
Depending on an application's process temperature range, accuracy specifications, and material compatibility, our sensors are available in Type K thermocouples, Type J thermocouples, Type E thermocouples, Type T thermocouples, Type S thermocouples, Type R thermocouples, and other dissimilar metal combinations. We manufacture thermocouple temperature sensors that can be designed with grounded or ungrounded junctions and housed in insulated sheath materials that are designed for best form fit in the applications.
RTD’sResistance thermometer use metals that alter their electric resistance when heated. Platinum is the most commonly used material for industrial RTD. However, Copper and Nickel are also used for some applications
ThermocoupleThermocouple types are composed of common, inexpensive metals such as nickel, iron and copper. The thermocouple types J, K, R & S are of this group and are the most commonly used type of thermocouple.
Application Areas
Technical Specification
Thermocouple Types | Measuring Range | Materials Used |
---|---|---|
J | 0°C to 750°C | Iron - Constantan |
K | 0°C to 1250°C | Chromel P-Alumel |
R | 0°C to 1450°C | Pt 13% Rhodium-Platinum |
S | 0°C to 1450°C | Pt 10% Rhodium-Platinum |
Take measurements from a safe distance with the Infrared Thermometer. Don't get burned by a motor, or have hot and cold air blowing in your face from your HVAC system or blowers while taking measurements. Infrared thermometers to get accurate temperature readings from a safe distance.
Standard AccessoriesCarrying case and Manual
ApplicationDistant measurement of Temperature in any Industrial plant, Coal Mines, Power Plants, Refectories, Kiln & Human Body temperature.
These thermometers enable measurement of temperature with an accuracy of +1% of the maximum scale value. This kind of thermometer system comprises a sensor bulb, transmitting capillary and a case containing a Bourdon Tube element. The system is filled with pressurised mercury. Temperature variation is measured by the Bourdon Tube system, and indicated on a dial.
ApplicationsChemicals, Refinery, Fertilizer, Petrochemicals, Pharmaceutical, Power, Cement, Sugar, Food, Beverages, Pulp Paper, Allied process industries which are having corrosive media or environment
INDUS make Magnetic Level Indicator provides clear, high clarity indication of liquid level. Typically, Magnetic Level Gauge consists of three major components: Float Chamber, Float and Indicator System. Magnetic Level Indicator is principally designed as an alternative to glass level gauges. We offer Magnetic Level Gauge having top-bottom, top and side mounted construction with two types of indicator system i.e. Capsule and Bi-colour Rollers. Magnetic level indicators are tailor made to various types of construction and sizes
Key FeatureGlandless gauge with magnetic coupling for visual level indication of Hazardous or Toxic Liquids, where glass is unsafe or for dilute caustics, where glass is unsuitable.
ApplicationTextile Dyeing, Sewage Water Processing, Power Generation, Chemical Processing and Heat Transfer Ships / Bulk Carriers